Tytuł:
Bi-axial neutral axis tracking for crack detection in wind turbine towers
Autorzy:
Soman, R.
Malinowski, P.
Ostachowicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/1938617.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska
Tematy:
structural health monitoring (SHM)
crack detection
wind turbine tower
neutral axis (NA)
Kalman Filter (KF)
data fusion
strain
Opis:
This work concentrates on Structural Health Monitoring (SHM) of a wind turbine tower. The paper investigates the use of a decision level data fusion based on bi-axial tracking of change in the neutral axis (NA) position for damage detection in wind turbine towers. A discrete Kalman Filter (KF) is employed for the estimation of the NA in the presence of measurement noise from the strain sensors. The KF allows data fusion from the strain sensors and the yaw mechanism for the accurate estimation of the NA. Any change in the NA position may be used for detecting and locating the damage. The tan inverse of the ratio of the change in the NA along two perpendicular axes is taken and used for the localization. The study was carried out on a simulated finite element (FE) model of a wind turbine tower with a surface crack. The sensitivity studies carried out on the structure in terms of different crack sizes, crack locations and crack orientations indicate that the methodology is robust enough to detect the crack under different operational loading conditions.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2015, 19, 3; 223-235
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementation of the LQG controller for a wind turbine tower-nacelle model with an mr tuned vibration absorber
Autorzy:
Rosół, M.
Martynowicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/280249.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
wind turbine tower vibration
tuned vibration absorber
MR damper
LQG control
Opis:
Vibration of a wind turbine tower is related to fatigue wear, influencing reliability of the whole structure. The current paper deals with the problem of Linear-Quadratic-Gaussian (LQG) tower vibration control using specially designed and built simulation and laboratory tower-nacelle models with a horizontally aligned, magnetorheological (MR) damper based tuned vibration absorber located at the nacelle. Force excitation applied horizontally to the tower itself, or to the nacelle, is considered. The MR damper LQG control algorithm, including the Kalman state observer and LQR (Linear-Quadratic-Regulator) controller is analysed numerically and implemented on the laboratory ground, in comparison with the system with a deactivated absorber. Simulation and experimental results are presented.
Źródło:
Journal of Theoretical and Applied Mechanics; 2016, 54, 4; 1109-1123
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of vibration control using laboratory test rig of wind turbine tower-nacelle system with MR damper based tuned vibration absorber
Autorzy:
Martynowicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/201323.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wind turbine vibration
tower-nacelle laboratory model
tuned vibration absorber
MR damper
tower vibration control
turbina wiatrowa
wibracje
system tower-nacelle
model laboratoryjny
tłumik drgań
MR
przepustnica
kontrola drgań
Opis:
Wind turbine tower dynamic stress is related to the fatigue wear and reliability of the whole wind turbine structure. This paper deals with the problem of tower vibration control using a specially designed and built laboratory model. The considered wind turbine tower-nacelle model consists of a vertically arranged stiff rod (representing the tower), and a system of steel plates (representing nacelle and turbine assemblies) fixed at its top. The horizontally aligned tuned vibration absorber (TVA) with magnetorheological (MR) damper is located also at the top of the rod (in nacelle system). Force excitation sources applied horizontally to the tower itself and to the nacelle were both considered. The MR damper real-time control algorithms, including ground hook control and its modification, sliding mode control, linear and nonlinear (cubic and square root) damping, and adaptive solutions are compared to the open-loop case with various constant MR damper input current values and system without MR TVA (i.e., MR TVA in “locked” state). Comprehensive experimental analyses and their results are presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 2; 347-359
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nieniszczące złączy spawanych na przykładzie wybranych elementów konstrukcyjnych siłowni wiatrowych
Non-destructive testing of welded joints on the exemplary selected structural elements of the wind turbines
Autorzy:
Kloskowski, L.
Pałubicki, S.
Kukiełka, K.
Powiązania:
https://bibliotekanauki.pl/articles/310154.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
złącze spawane
spoina
badania nieniszczące
wieża siłowni wiatrowej
weld joint
weld
non-destructive testing
tower of a wind turbine
Opis:
W artykule przedstawiono metody, procedury i normy związane z kontrolą złączy spawanych metodą badań nieniszczących oraz wyniki badań połączeń spawanych sekcji dolnej wieży siłowni wiatrowej. Scharakteryzowano proces spawania stosowany w przemyśle stalowym, rodzaje złączy spawanych, metody spawania oraz mogące wstępować w spoinie niezgodności tj. pęknięcia, przyklejenia, braki przetopu itp., które wpływają negatywnie na wytrzymałość przyszłego złącza spawanego. Przedstawiono poziomy jakości i kryteria akceptacji w świetle norm związanych z badaniami nieniszczącymi złączy spawanych: wizualnymi i magnetyczno-proszkowymi dla nieciągłości zewnętrznych i ultradźwiękowymi dla nieciągłości wewnętrznych. Najbardziej negatywny wpływ na funkcjonowanie wieży siłowni wiatrowej mają pęknięcia i głębokie przyklejenia, ponieważ przy niekorzystnych warunkach użytkowania konstrukcji wieży może występować szybki wzrost naprężeń w czasie pracy urządzenia. Dlatego też na etapie produkcji należy znaleźć przyczynę powstawania tego typu niezgodności.
The article presents the methods, procedures, and standards related to the control of welded joints by non-destructive testing and the results of welded joints of the lower section of a wind turbine tower. Characterize the welding process used in the steel industry, the types of welds, welding method and which may join in the joint inconsistency is cracking, gluing, lack of fusion etc., that have a negative impact on the future strength of the welded joint. Levels of quality and acceptance criteria in the light of the standards relating to non-destructive testing of welded joints: visual and magnetic discontinuities powder for external and internal ultrasound to discontinuities. The most negative impact on the operation of the wind turbine tower with cracks and deep stick, because under unfavorable conditions of the structure of the tower can be a rapid increase in stress during operation. Therefore, at the stage of production should be found the cause of this type of non-compliance.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2015, 16, 6; 113-122
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies