Determinants of the operation of Poland’s water utilities
Autorzy:
Chudziński, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/419661.pdf
Data publikacji:
2018
Wydawca:
Wydawnictwo Uniwersytetu Ekonomicznego we Wrocławiu
Tematy:
benchmarking
water utility
efficiency
water tariffs
Opis:
The aim of this paper is to present the situation of Polish water utilities from the perspective of cost benchmarking against the background of international experience, and to discuss the merits of using benchmarking with a view to improving water utilities efficiency. The text examines the income side of the issue by focusing on the water tariff levels used by Polish water utilities. The author’s experience is that the first effects of using benchmarking in cost management are achieved after about three years of participating in benchmarking project. Another important threat is the difficulty in finding benchmarking partners or a proper benchmarking project. The third one, in the author’s view the most significant, is an inadequate preparation of benchmarking indicators. The implementation of benchmarking of cost management at Aquanet SA produced measurable results, presented in this paper. It could be concluded, therefore, that using this method of cost management contributes to cost efficiency and, as a result, increases the efficiency of water utilities.
Źródło:
Nauki o Zarządzaniu; 2018, vol. 23 no. 1; 13-19
2080-6000
Pojawia się w:
Nauki o Zarządzaniu
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-stage magnetic-fluid seals for operating in water - life test procedure, test stand and research results. Part II Results of life tests of multi-stage magnetic - fluid seal operating in water
Autorzy:
Matuszewski, L.
Powiązania:
https://bibliotekanauki.pl/articles/259203.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
shaft sealing
magnetic fluid
utility water
seal durability
critical pressure
critical motion velocity
Opis:
The edge criteria for magnetic-fluid seals durability research were described in previous article [24] and now the tests results are presented. The tests were made with three magnetic fluids using various magnets quantity in magnetic assemblies. If values obtained in the repeated test deviated by more than 10 % from results of the first test an additional control test was made for final characteristics. The characteristics are: critical pressure, critical motion velocity and working life of the seal. The test stands were prepared for particular seals dimensions and results of tests are presented in the form of tables, cross section draws and diagrams. In conclusion one can see that multi-stage magnetic-fluid seals could be efficiently used in water for rotating shaft seals in a limited range of motion velocity and cycles quantity. Nevertheless a particular applications can be provided by magnetic-fluid seals only.
Źródło:
Polish Maritime Research; 2013, 1; 39-47
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Life tests of a rotary single-stage magnetic-fluid seal for shipbuilding applications
Autorzy:
Matuszewski, L.
Szydło, Z.
Powiązania:
https://bibliotekanauki.pl/articles/258558.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
shaft sealing
magnetic fluid
utility water
seal durability
critical pressure
critical motion velocity
Opis:
Use of the magnetic fluid seal technology in water is much more difficult technological problem in comparison to gas or vacuum environment. Some seals constructed up to time been are designed as hybrid, two stage sealing structures with shields or mechanical seals used as protection measures to the magnetic fluid seal. Anyway, there is always problem with immediate contact between magnetic fluid and the environmental liquid. In the paper are presented results of experiments carried out with one stage rotating magnetic fluid seal operating in immediate contact with utility water. The special test procedures have been elaborated and practically used, with the aim to define main characteristics of magnetic fluid seals and to simplify experiments. These characteristics were: critical pressure, critical motion velocity and working life of the seal. Four grades of commercial, silicon based magnetic fluids of hydrophobic properties were tested in a single stage sealing system. The results of tests are presented in the form of tables and diagrams. It is concluded that hydrophobic commercial magnetic fluids could be efficiently used in rotating shaft seals however in a limited range of motion velocity.
Źródło:
Polish Maritime Research; 2011, 2; 51-59
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-stage magnetic-fluid seals for operating in water – life test procedure, test stand and research results. Part. I. Life test procedure, test stand and instrumentation
Autorzy:
Matuszewski, L.
Powiązania:
https://bibliotekanauki.pl/articles/260287.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
shaft sealing
utility water
seal durability
critical pressure
critical motion velocity
magnetic fluid
Opis:
The edge criteria for magnetic-fluid seals durability research are critical for the seal’s technological usefulness. The magnetic fluid seal technology in water is much more difficult technological problem in comparison to gas or vacuum environment. There is always problem with immediate contact between magnetic fluid and the environmental uninspected liquids. In the paper are presented ways of experiments definitions carried out with multi-stage rotating magnetic fluid seal operating in permanent contact with utility water. The special test procedures have been elaborated and practically used, with the aim to define main characteristics of magnetic fluid seals. These characteristics were: critical pressure, critical motion velocity and working life of the seal. Some grades of commercial, silicon based magnetic fluids of hydrophobic properties were tested in sealing system. The test stand and its features as well as results of tests are presented in the form of tables, cross section draws and diagrams. In conclusion one can see that multi-stage magnetic-fluid seals could be efficiently used in water for rotating shaft seals in a limited range of motion velocity and work lasting.
Źródło:
Polish Maritime Research; 2012, 4; 62-70
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innowacyjna metoda dostarczania wody do spożycia w sytuacjach kryzysowych
An Innovative Method for Supplying Water for Consumption in Crisis Situations
Autorzy:
Denczew, S.
Powiązania:
https://bibliotekanauki.pl/articles/373014.pdf
Data publikacji:
2018
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
dostawa wody
wzór użytkowy
sytuacja kryzysowa
bezpieczeństwo dostaw wody
powódź
skażenie wody
water supply
utility model
crisis situation
security of water supply
flood
water contamination
Opis:
Cel: Doniesienie wstępne dotyczące udzielenia prawa ochronnego na wzór użytkowy pt. „Tymczasowe mobilne stanowisko do uzdatniania wody do spożycia” szczególnie przydatne w sytuacjach kryzysowych, głównie powodzi, kiedy następuje skażenie wody w ujęciach powierzchniowych i głębinowych. Jest ono końcowym efektem badań statutowych autora w Szkole Głównej Służby Pożarniczej. Właścicielem wzoru użytkowego jest Szkoła Główna Służby Pożarniczej, natomiast twórcą wzoru użytkowego jest prof. dr hab. inż. Sławczo Denczew. Obecnie w ramach badań podjęto próbę wykonania prototypu, następnie realizowane będą prace badawcze dotyczące zastosowania wzoru użytkowego w warunkach rzeczywistych. Metody: W artykule zaprezentowano aktualny wykaz sposobów dostarczania wody dla ludności w sytuacjach kryzysowych. Uwzględniając obecny stan wiedzy na ten temat w Europie i na świecie, zaproponowano innowacyjne mobilne stanowisko uzdatniania wody, mające na celu remedium na problem dostaw wody dla ludności w sytuacjach kryzysowych. Stanowić ma ono alternatywne rozwiązanie przydatne szczególnie w przypadkach powodzi, kiedy poprzez zalewanie terenów objętych stanem powodziowym następuje zanieczyszczenie oraz skażenie źródeł wody w systemach zaopatrzenia w wodę. Wyniki: Na podstawie przeglądu literatury, patentów i wzorów użytkowych w bazach urzędów patentowych w Europie i na świecie opracowano wzór użytkowy pt. „Tymczasowe mobilne stanowisko do uzdatniania wody do spożycia”, który posiada prawo ochronne wydane przez Urząd Patentowy do 2023 roku. Brak takich rozwiązań na świecie potwierdza jego innowacyjny i oryginalny charakter. Wnioski: Opracowanie dokumentacji wzoru użytkowego pt. „Tymczasowe mobilne stanowisko do uzdatniania wody do spożycia” oraz udzielenie prawa ochronnego stwarzają możliwości wykonania prototypu i zrealizowania badań dotyczących dostawy wody dla ludności w sytuacjach kryzysowych. Może ono być zastosowane zarówno na terenach miejskich, jaki na niezurbanizowanych, gdzie istnieje rozproszona zabudowa oraz przeważają duże odległości pomiędzy zagrodami i –co za tym idzie – mobilność jest jednym z warunków szybkiego dotarcia do zabudowań i dostarczenie wody niezbędnej do życia.
Aim: Preliminary application for a utility model entitled „Temporary mobile station for the treatment of water for consumption”, particularly useful in emergency situations, such as floods, when both surface and deep water is contaminated. It is the final result of statutory research of the author at the Main School of Fire Service. The owner of the utility model is the Main School of Fire Service, while the author of the utility model is Prof. Slawczo Denczew. Currently, research is underway to develop a prototype and then carry out research on the use of the utility model in real life situations. Methods: The article presents current ways of supplying water to the general public in crisis situations. Taking into account the state of the art in Europe and worldwide, an innovative mobile water treatment post has been proposed to tackle the problem of emergency water supply to the public in emergency situations. It is intended to constitute an alternative solution, useful especially during flooding, when water sources within water supply systems are contaminated and polluted. Results: Based on a review of literature, patents and utility models in the patent offices in Europe and worldwide, we have developed a temporary mobile station for the treatment of water for consumption, which is protected by a utility model granted by the Patent Office until 2023. The lack of such solutions in the world confirms its innovative and original character. Conclusions: Following the development of utility model documentation for the temporary mobile station for the treatment of water for consumption and the granting of utility model protection, we are able to build a prototype and carry out studies on the supply of water to the public in crisis situations. Our invention can be used in both urban and rural areas with dispersed housing and generally large distances between the farms, where mobility is one of the conditions for quick access to buildings and the supply of water necessary for life.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2018, 49, 1; 60-65
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Legionella spp. in selected public utility buildings in Poland in 2009-2013
Występowanie bakterii Legionella sp. w wybranych obiektach użyteczności publicznej w Polsce w latach 2009-2013
Autorzy:
Shpakou, A.
Gladysz, I.
Sikora, A.
Wójtowicz-Bobin, M.
Kozioł-Montewka, M.
Powiązania:
https://bibliotekanauki.pl/articles/2052685.pdf
Data publikacji:
2017
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
Legionella spp.
Legionnaires’ Disease
hot water distribution systems
public utility buildings
Legionella sp.
choroba legionistów
systemy dystrybucji wody ciepłej
budynki użyteczności publicznej
Opis:
Background. Civilizational changes, including urbanisation and industrialisation, created the conditions for the development of new pathogens colonising water networks which endanger human health and life. The aim of the study was to assess the contamination of water supply systems in public buildings by Legionella spp. a pathogenic group of Gram-negative bacteria. Material and methods. The material samples were taken from the hot water supply systems of 41 buildings: school dormitories, boarding schools, educational centres, student dormitories. Results. In all analysed years, there were samples in which the applicable standards were exceeded, as specified by the regulation on the quality of water intended for human consumption. The highest percentage of negative samples was found in 2012, with as many as 81.1%, and the lowest one in 2011 − 35.3%. Positive samples obtained in the first and subsequent tests were detected in 20.0% of the tested facilities. The change from positive to negative values was found in 30.0% of the tested water networks. There were also cases of negative samples both in the first and subsequent tests, which was detected in 50.0% of the facilities. Conclusions. 1. An excessive amount of the officially permissible value of Legionella was found in 53.9% of the examined hot water samples. 2. The obtained results confirm the necessity of modernising and doing elementary repairs in water supply networks.
Wprowadzenie. Zmiany cywilizacyjne w tym urbanizacja i industrializacja stworzyły warunki do rozwoju nowych patogenów kolonizujących sieć wodną, które zagrażają zdrowiu i życiu ludzi. Celem pracy była ocena zanieczyszczenia systemów wodnych w budynkach użyteczności publicznej przez bakterie Legionella sp. Materiał i metody. Materiałem były próbki wody ciepłej pobrane z wewnętrznej instalacji wodociągowej 41 obiektów: bursy szkolne, internaty, ośrodki szkolno-wychowawcze, domy studenta. Wyniki. Próbki przekraczające obowiązujący normatyw, określony rozporządzeniem w sprawie jakości wody przeznaczonej do spożycia przez ludzi, stwierdzono we wszystkich analizowanych latach. Najwyższy odsetek próbek negatywnych stwierdzono w roku 2012 aż 81,1%, najniższy w roku 2011 - 35,3%. Próbki pozytywne uzyskane w pierwszym i kolejnych badaniach, stwierdzono w 20,0% badanych obiektów. Konwersję próbek pozytywnych w negatywne stwierdzono w 30,0% badanych obiektów. Próbki negatywne nieobecne w pierwszym i kolejnych badaniach wykryto w 50,0% obiektów. Wnioski. 1. Przekroczenie obowiązującej dopuszczalnej wartości bakterii Legionella sp. stwierdzono w 53,9% badanych próbek wody ciepłej. 2. Uzyskane wyniki badań potwierdzają konieczność modernizacji i zasadniczych remontów sieci wodnej.
Źródło:
Health Problems of Civilization; 2017, 11, 2; 117-123
2353-6942
2354-0265
Pojawia się w:
Health Problems of Civilization
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zużycia mediów po przeprowadzonej termomodernizacji
The assessment of media consumption after thermal modernization
Autorzy:
Ujma, A.
Lis, A.
Powiązania:
https://bibliotekanauki.pl/articles/2065360.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska
Tematy:
termomodernizacja
zużycie wody
zużycie ciepła
zużycie prądu
zużycie gazu
koszt mediów
thermal modernization
water consumption
electric power consumption
gas consumption
utility costs
Opis:
Ochrona cieplna budynków i racjonalizacja zużycia mediów są bezpośrednio związane z oszczędnością energii, ale również z innymi aspektami. W artykule przedstawiono rzeczywiste rezultaty termomodernizacji na podstawie monitorowania jej efektów w czterech budynkach oświatowych. Analiza obejmuje zużycie wody, prądu, gazu i ciepła w tych budynkach. Zaobserwowano spadek zużycia mediów po termomodernizacji. Zanotowano znaczący spadek wskaźników zużycia mediów na jednego ucznia w ciągu roku w badanych szkołach.
The thermal protection of buildings and rationalization of water consumption are directly related with energy savings but also with other aspects. The article presents the real results of the thermal modernization activity based on the monitoring of their effects in four educational buildings. The analysis includes water, electricity and energy consumption of these buildings. It was found that after thermal modernization the reduction of the consumption of water, electricity and gas has been noticed. The significant decrease in rates of consumption of media attributed to one student, the learner in a year, in the analyzed schools has been registered.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2014, 2 (14); 103--110
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sieci przesyłowe w krajobrazie miejskim
Hard infrastructure in urban landscape
Autorzy:
Kostecki, J.
Owoc, E.
Powiązania:
https://bibliotekanauki.pl/articles/371998.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
infrastruktura przesyłowa
krajobraz miejski
gazociąg
wodociąg
kanalizacja
energia elektryczna
hard infrastructure
urban landscape
gas pipelines
water supply system
sewerage system
utility wire
Opis:
Funkcjonowanie obszarów miejskich w świetle warunków życia mieszkańców nie może odbywać się bez zdobyczy cywilizacyjnych takich jak bieżąca woda czy energia elektryczna. W artykule przedstawiono warunki funkcjonowania sieci przesyłowych w krajobrazie miejskim z uwzględnieniem ładu przestrzennego.
It's hard to imagine urban areas nowadays without such achievements of civilization as running water or electricity. In the article authors presents the conditions of the transmission network in the urban landscape in the light of spatial order.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2011, 142 (22); 86-97
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opracowanie metodologii badań oraz wykonanie wstępnych oznaczeń obecności bakterii Legionella spp i Legionenella pneumophila w próbkach środowiskowych wody metodą immunomagnetoseparacji połączonej z cytometrią przepływową
Methodology for testing and preliminary determination of the presence of Legionella spp. and Legionella pneumophila in environmental water samples by immunomagnetic separation combined with flow cytometry
Autorzy:
Dąbrowiecki, Zbigniew
Dąbrowiecka, Małgorzata
Olszański, Romuald
Siermontowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1359341.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
Legionella spp
Legioneloza
immunoseparacja
cytometria przepływowa
systemy dystrybucji ciepłej wody
obiekty użyteczności publicznej
okręty
Legionnaires’ Disease
immunomagnetic separation
flow cytometry
hot water distribution systems
public utility buildings
ships
Opis:
W przypadku wystąpienia epidemii Legionelozy, szybkie i jednoznaczne określenie źródła infekcji, oraz natychmiastowe podjęcie czynności naprawczych jest warunkiem niezbędnym do ograniczenia i zminimalizowania skutków rozwijającej się epidemii. W klasycznej metodzie oznaczania poziomu bakterii z rodzaju Legionella w próbkach wody, skuteczność działania reparacyjnego (podwyższenia temperatury wody w instalacji wodociągowej do 600C, dodatkowe chlorowanie) może być potwierdzone dopiero po 14 dniach!!! Tylko metoda IMMS&FCM skraca czas oznaczenia bakterii Legionella do 2-4 godzin, co jest najważniejszym czynnikiem ograniczenia rozwoju epidemii.
In the event of an epidemic of Legionnaires' disease, prompt and unambiguous identification of the source of infection and immediate undertaking of repair actions is a necessary condition to limit and minimise the effects of the developing epidemic. In the classical method for determining the level of Legionellabacteria in water samples, the effectiveness of the reparative action (increase of the water temperature in the water supply system to 600C, additional chlorination) can only be confirmed after 14 days!!! Only by using the IMMS&FCM method can Legionella's determination time be reduced to 2-4 hours, which is the most important factor in limiting the development of an epidemic.
Źródło:
Polish Hyperbaric Research; 2019, 3(68); 71-92
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies