Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water treatment process" wg kryterium: Temat


Tytuł:
Analysis and assessment of technological processes of the Miedwie Lake surface water treatment plant for the city of Szczecin
Analiza i ocena procesów technologicznych stacji uzdatniania wody powierzchniowej z jeziora Miedwie dla miasta Szczecina
Autorzy:
Wira, J.
Wira, D.
Powiązania:
https://bibliotekanauki.pl/articles/84845.pdf
Data publikacji:
2005
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
technological process
Lake Miedwie
surface water
water treatment plant
Szczecin city
protection zone
lake water
tributary
raw water
clean water
water parameter
water analysis
water temperature
chloride
chemical oxygen demand
oxidizability
pH reaction
alkalinity
carbon dioxide
Opis:
Miedwie Lake is the biggest post-glacial lake of the West-Pomeranian Voievodship. At the same time it is the fifth of the largest lakes in Poland. As regards the geographical situation, Miedwie Lake is situated centrally between three big agglomerations i.e. Szczecin, Stargard Szczecinski and Pyrzyce (Fig. 1). The lake lies on the territory of three municipalities: Pyrzyce and Warnice in the District of Pyrzyce as well as Stargard Szczecinski in the District of Stargard (Rozmiarek 1983, Szyper 1990). At the moment, the reservoir is characterised with the regular, prolonged shape resembling an ellipse. Banks are shallow, regular and sometime very wet. The lake has the belt of the nearshore reaching locally tens metres far from the lake bank, what is the reason, together with the fact that the wind blows always here, that it is convenient for practising the various kinds of water sports. The lake area amounts to 3 527 ha; maximal depth – 43.8 m; average depth – 19.3 m; water capacity – 681.7 mln m3; shore-line length – 38.8 km; water level datum 14.1 m above sea level; maximal width 3.16 km; maximal length 16.2 km. The lake’s bottom is the lowest situated area on the territory of Poland.
Ujecie wody „Miedwie” powstało w roku 1976. Do tego czasu wody jeziora odpowiadały pierwszej klasie czystości. Jednakże jakość wody zaczęła się pogarszać już po rozpoczęciu eksploatacji ujęcia, dochodząc aż do poziomu trzeciej klasy czystości. Przyczyną był brak oczyszczalni oraz PGR-y. Zanieczyszczenie zbiornika powodowało masowe śniecią ryb (siei miedwiańskiej), przy dnie pojawił się siarkowodór, masowo zakwitały glony. Dalsze pogarszanie się stanu jeziora groziło zamknięciem ujęcia wody oraz wyniszczeniem życia biologicznego w zbiorniku, jak również wokół niego. Spadek jakości wód jeziora spowodowany był kilkoma czynnikami: rolnictwo, baza rosyjska w Kluczewie, turystyka, dopływy jeziora, biomanipulacja wodami Miedwia.
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2005, 09
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the most effective operating conditions of membrane bioreactor used to industrial wastewater treatment
Autorzy:
Świerczyńska, A.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/208164.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wastewater treatment
activated sludge process
bioconversion
bioreactors
industrial water treatment
landfill
leachate treatment
water treatment
activated sludge
dairy wastewater
industrial wastewater treatment
membrane bioreactor
municipal landfills
oczyszczalnia ścieków
proces osadu czynnego
biokonwersja
bioreaktory
uzdatnianie wody przemysłowej
uzdatnianie wody
osad czynny
ścieki mleczarskie
oczyszczanie ścieków przemysłowych
bioreaktor membranowy
składowiska odpadów komunalnych
Opis:
The effectiveness of co-treatment of leachates from an old site of municipal landfill with a dairy industry wastewater in a membrane bioreactor has been investigated. The subjects of the study were leachates collected at the municipal landfill in Tychy and dairy wastewaters from Dairy Plant in Bieruń. The determination of the most effective technological parameters of the process, i.e. activated sludge load and its concentration and types of COD fractions in the reactor influent was made. It was shown that the activated sludge load at the level of 0.06 g COD/(gDM·d) was the highest permissible one among all the investigated loads and the process run effectively within the whole investigated range of concentrations of activated sludge in a bioreactor. It was found that in the treated wastewater, the fraction of easily degradable organic compounds was the dominant one.
Źródło:
Environment Protection Engineering; 2015, 41, 1; 41-51
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of pesticides and inorganic pollutants by reverse osmosis
Autorzy:
Šír, M.
Podhola, M.
Patočka, T.
Honzajková, Z.
Kocurek, P.
Bystrianský, M.
Vurm, R.
Kubal, M.
Powiązania:
https://bibliotekanauki.pl/articles/207770.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
groundwater
groundwater pollution
pesticides
reverse osmosis
water treatment
batch process
chlorinated pesticides
inorganic pollutants
polyamide membranes
wody gruntowe
zanieczyszczenie wód gruntowych
pestycydy
odwrócona osmoza
uzdatnianie wody
proces wsadowy
chlorowane pestycydy
zanieczyszczenia nieorganiczne
membrany poliamidowe
Opis:
Contamination of soil and groundwater with pesticides is mainly caused by old ecological burdens. This study focuses on the treatment of groundwater contaminated with chlorinated pesticides. The contaminants mainly include α-HCH, β-HCH, γ-HCH, HCB, DDE, DDD and DDT. Reverse osmosis technology using RO98pHt polyamide membranes was used to remove the pollutants under batch process conditions. The observed rate of removal ranged from 98.4% to 99.7%. Total dissolved content solids decreased from 1.35 g/dm3 to below 0.05 g/dm3.
Źródło:
Environment Protection Engineering; 2015, 41, 2; 159-166
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przydomowe oczyszczalnie ścieków jako działalność inwestycyjna w świetle regulacji prawnych
Home sewage-treatment plants as an investment activity in view of legal regulations
Autorzy:
Sikorski, M.
Bauman-Kaszubska, H.
Powiązania:
https://bibliotekanauki.pl/articles/339449.pdf
Data publikacji:
2006
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
pozwolenie na budowę
pozwolenie wodnoprawne
proces inwestycyjny
projekt budowlany
przydomowa oczyszczalnia ścieków
zgłoszenie budowy i eksploatacji
building and exploitation application
building permit
construction design
home sewage-treatment plant
investment process
water supply and sewage discharge consent
Opis:
W referacie przedstawiono analizę i ocenę regulacji formalno-prawnych z zakresu prawodawstwa wodnego i budowlanego, w szczególności dotyczących pozwoleń wodno-prawnych, pozwoleń na budowę, eksploatację obiektów, wymagań formalnych dotyczących formy, treści i zakresu dokumentacji projektowej.
The paper presents an analysis and evaluation of legal regulations in water and building legislation, pertaining particularly to water supply and sewage treatment consent, building permits, exploitation of objects, formal requirements concerning a form, contents and range of project documentation.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2006, 6, 1; 381-389
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of an automated system for electrochemical production of coagulant based on photocolorimetric analysis
Autorzy:
Safonyk, Andrii
Hrytsiuk, Ivanna
Klepach, Marko
Mishchanchuk, Maksym
Khrystyuk, Andriy
Powiązania:
https://bibliotekanauki.pl/articles/2073739.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
coagulant
colour of water
electrocoagulation process
photocolorimetric method
RGB
total iron
wastewater treatment
Opis:
The article describes the development of a model problem for electrocoagulation treatment of industrial wastewater taking into account changes in voltage and current. The study included computer simulation of the change in the concentration of iron at the output of the electrocoagulator at variable current levels. The laboratory-scale plant was developed for the photocolorimetric analysis of the iron-containing coagulant. It consisted of a flowing opaque cel through which water is pumped with a constant flow and also the block for processing and storage of information. Such structure allows to reduce human participation in the measurement process and to ensure the continuity of measurement without any need for sampling of the tested material, as well as to reduce the measurement cost. During the processing of results, graphical dependences were determined between RGB-components of water colour and the corresponding concentration of total iron and Fe3+ in water.
Źródło:
Journal of Water and Land Development; 2022, 52; 75--80
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie zanieczyszczeń z wód w hybrydowym reaktorze membranowym przy współudziale procesu MIEX®DOC
Removal of contaminants from water in hybrid membrane reactor in cooperation MIEX®DOC process
Autorzy:
Rajca, M.
Powiązania:
https://bibliotekanauki.pl/articles/127542.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
proces MIEX DOC
ultrafiltracja
reaktor membranowy
oczyszczanie wód
MIEX DOC process
ultrafiltration
membrane reactor
water treatment
Opis:
Celem pracy było określenie efektywności usuwania zanieczyszczeń organicznych i nieorganicznych z wody w hybrydowym reaktorze membranowym, w którym realizowano proces wymiany jonowej i ultrafiltracji. W badaniach wykorzystano żywicę MIEX® firmy Orica Watercare oraz ultrafiltracyjny moduł kapilarny zanurzeniowy ZeeWeed 1 (ZW 1), pracujący w podciśnieniu, wykonany z polifluorku winylidenu, firmy GE Power&Water. Zastosowanie wielofunkcyjnego reaktora korzystnie wpływało na efektywność usuwania zanieczyszczeń, uzyskując wodę oczyszczoną wysokiej jakości, a w odniesieniu do procesu ultrafiltracji zminimalizowano problem foulingu membrany.
The aim of this study was to determine the effectiveness of removal of organic and inorganic contaminants from water using hybrid membrane reactor in which ion exchange and ultrafiltration processes were performed. MIEX® resin by Orica Watercare and immersed ultrafiltration polyvinylidene fluoride capillary module ZeeWeed 1 (ZW 1) by GE Power&Water operated at negative pressure were used. The application of multifunctional reactor had a positive effect on the removal of contaminants and enabled the production of high quality water. Additionally, in refer to single stage ultrafiltration it minimalized the occurrence of membrane fouling.
Źródło:
Proceedings of ECOpole; 2013, 7, 1; 393-398
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie wód popłucznych w oczyszczaniu odcieków z prasy filtracyjnej
The use of backwash water in the purification of leachate from the filter press
Autorzy:
Płonka, I.
Pieczykolan, B.
Fukas-Płonka, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/126031.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wykorzystanie wód popłucznych
komunalne osady ściekowe
oczyszczanie odcieków z procesu odwadniania osadów
use of backwash water
municipal sewage sludge
treatment of leachate from the dewatering process of sludge
Opis:
W komunalnej oczyszczalni ścieków w technologii przeróbki osadów zazwyczaj stosowany jest proces odwadniania mechanicznego. W procesie tym oprócz odwodnionego osadu powstają tzw. odcieki. Odcieki charakteryzują się dużym ładunkiem zanieczyszczeń, w tym dużym stężeniem fosforu. W przypadku zawracania do ciągu oczyszczania ścieków stanowią one dodatkowe obciążenie ładunkiem zanieczyszczeń. Z tego względu powinny być wcześniej podczyszczane w bocznym ciągu oczyszczania. Z kolei wody popłuczne pochodzące ze stacji uzdatniania wód podziemnych zawierają duże stężenie jonów żelaza. Wymieszanie wód popłucznych z odciekami może okazać się korzystnym rozwiązaniem. W związku z tym podjęto badania wykorzystania wód popłucznych do oczyszczania odcieków. Wprowadzone sole żelaza(III) do odcieków ulegają hydrolizie, tworząc hydroksykompleksy. W takiej postaci hydrokompleksy związków żelaza w odciekach mogą prowadzić do sorpcji zanieczyszczeń, powstawania kompleksów soli żelaza oraz współstrącania i strącania osadów. Celem badań było określenie wpływu wód popłucznych na jakość odcieków pochodzących z odwadniania osadów ściekowych z komunalnej oczyszczalni ścieków. Proces koagulacji odcieków z wodami popłucznymi prowadzono w temperaturze 6 i 20°C. Odcieki z wodami popłucznymi mieszano w taki sposób, aby uzyskać stosunek Fe/P, wynoszący 0,5; 1,0; 1,5; 2,0; 2,5; 3,0. Przeprowadzone badania wykazały, że po procesie w odciekach uzyskano obniżenie zarówno stężenia fosforu, jak i zawartości ChZT, odpowiednio do poziomu 4,5-20,7 mg/dm3 w temperaturze 6°C i 4,5-8,4 mg/dm3 w temperaturze 20°C oraz 79-180 mg/dm3 w temperaturze 6°C i 72-140 mg/dm3 w temperaturze 20°C.
Mechanical dewatering process is most typically method of sludge treatment used on municipal sewage treatment plant. In this process leachate are generated besides the dewatered sludge. Leachate has a high pollutant load, including a high concentration of phosphorus. In the case of discharging them to the main line of wastewater treatment, they are additional load of organic and phosphorus compounds. Therefore, they should be previously pre-treating in the side-treatment system. The backwash water from groundwater treatment plants contain a high concentration of iron ions. Mixing backwash water and leachate may be preferred solution. Therefore, study was carried using backwash water to leachate treatment. Salts of iron(III) submitted to the effluents are hydrolyzed and are formed hydroxy complexes. In this form iron can cause sorption of pollutants, formation of complexes of iron salts and co-precipitation or precipitation of sludge. The aim of this study was to determine the effect of backwash water on quality of leachate from the dewatering process of sludge from municipal sewage treatment plant. The coagulation process of backwash water with leachate was carried out in 6 and 20°C. The leachate and backwash water were mixed in such proportion to obtain the ratios of Fe/P equaled to 0.5; 1.0; 1.5; 20; 2.5; 30. The study showed that the following process allowed to reduce both phosphorus and COD concentration in the leachate. Concentrations of phosphorus compounds after process were in range of 4.5-20.7 and 4.5-8.4 mg/dm3 respectively at 6 and at 20°C. In the case of COD, its value in leachate after coagulation was in range of 79-180 and 72-140 mg/dm3 respectively at 6 and at 20°C.
Źródło:
Proceedings of ECOpole; 2016, 10, 1; 267-272
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post-coagulation sludge as an adsorbent of dyes from aqueous solutions
Osad pokoagulacyjny jako adsorbent barwników z roztworów wodnych
Autorzy:
Pieczykolan, B.
Płonka, I.
Powiązania:
https://bibliotekanauki.pl/articles/127092.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
water treatment
coagulation
post-coagulation sludge
dyes
waste sorbent
sorption process
sorption isotherm
uzdatnianie wody
koagulacja
osad pokoagulacyjny
barwnik
proces sorpcji
sorbenty odpadowe
izoterma sorpcji
Opis:
Water taken from the environment, before it is directed to recipients as drinking water, must be purified via different processes. From the water, inter alia, suspensions, organic compounds, colloidal particles as well as bacteria and viruses must be removed. The main source of usable water supply is surface water. The most frequently used methods of surface water treatment are coagulation and filtration processes. During these processes post-coagulation sludge is generated, which is the main waste produced in water treatment plants. This sludge is characterized by an amorphous structure with a strongly developed specific surface, similar to sewage sludge. In addition, it has a high content of organic compounds. In recent years, attempts have been made to transform sewage sludge from municipal wastewater treatment plants into waste sorbents. Taking into account some similarity between sewage sludge and post-coagulation sludge, an attempt was made to apply post-coagulation sludge as sorbent of dyes from aqueous solutions. Dried and crushed post-coagulation sludge was used in the studies. The most favourable pH of process and contact time as well as sorption isotherm were established. Moreover, based on the different isotherm two-parameter models, the sorption capacity, type of sorption and energy of sorption were calculated.
Woda pitna, zanim zostanie skierowana do odbiorców, musi zostać poddana procesom oczyszczania. Z wody muszą zostać usunięte między innymi zawiesiny, substancja organiczna, cząstki koloidalne oraz bakterie i wirusy. Głównym źródłem zaopatrywania w wodę użytkową są wody powierzchniowe. Najczęściej stosowanymi metodami uzdatniania wody powierzchniowej są metody koagulacji i filtracji. W trakcie tych procesów powstają osady pokoagulacyjne, które są głównymi odpadami powstającymi w zakładach uzdatniania wody. Osady te charakteryzują się strukturą amorficzną o mocno rozbudowanej powierzchni właściwej, podobnie jak osady ściekowe. Ponadto posiadają dużą zawartość związków organicznych. W ostatnich latach podjęto próby przeróbki osadów ściekowych pochodzących z komunalnych oczyszczalni ścieków w celu uzyskania odpadowych sorbentów. Uwzględniając pewne podobieństwo pomiędzy osadami ściekowymi, jak również pokoagulacyjnymi podjęto próbę wykorzystania osadów pokoagulacyjnych jako sorbentów barwników z roztworów wodnych. W trakcie badań wykorzystano wysuszone i rozdrobnione osady pokoagulacyjne. Wyznaczono najkorzystniejsze parametry procesu sorpcji statycznej (pH i czas kontaktu), jak również izotermę adsorpcji. Ponadto wykorzystując różne modele dwuparametryczne, wyznaczono maksymalną pojemność sorpcyjną, typ adsorpcji oraz energię adsorpcji.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 315-323
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of Biofiltration Process to Remove Organic Matter From Groundwater
Autorzy:
Papciak, D.
Kaleta, J.
Puszkarewicz, A.
Tchórzewska-Cieślak, B.
Powiązania:
https://bibliotekanauki.pl/articles/952351.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
groundwater
biofiltration process
total organic carbon (TOC)
water treatment
Opis:
The article describes the research on the removal of organic matter from natural underground water using biofiltration process. The study was carried out in semi-technical scale on a model filter composed of activated carbon WD-extra. The development of biological activity in a biosorption bed, as well as observations on the relationship between the processes of sorption and biodegradation was evaluated based on the Eberhardt, Madsen, Sontheimer (EMS) test. Leading operation control parameters of biologically active carbon filter BAF included: change of TOC content, dissolved oxygen and permanganate index. To evaluate the colonization of granular carbon determination of ATP value was used. The presence of the biofilm was found by observation using light and scanning microscopes. The organic compounds in the water taken were adsorbed 100% and 70% biodegradable. The combination of sorption process with biodegradation until depletion of activated carbon adsorption capacity allowed in the initial phase of coalbed work for the removal of organic matter in approx. 100%. Formation of biofilm at the right time allowed to extend the filtration cycle and helped lower the TOC by 70%, i.e. from 10 mg C/l to 3–4 mg C/l.
Źródło:
Journal of Ecological Engineering; 2016, 17, 3; 119-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of water treatment plant based on feedforward neural network
Autorzy:
Mohamed, A. F.
Radwa, H. Z.
Powiązania:
https://bibliotekanauki.pl/articles/971051.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
water treatment plant
coagulation process
PID
neural network control
Opis:
Coagulation process is the main process in conventional water treatment process sequence. It influences the following treatment process aspects: maintaining plant efficiency and increasing the quality of the produced water. This is accomplished by adding chemicals to raw water, such as alum sulphate. To secure the appropriate plant performance, a mathematical model is proposed in this paper for the coagulation unit, followed by the development of the control strategy. Classic PID and neural network based controller regulating the process are used. Tests were performed, based on the real data for water treatment, using MATLAB/SIMULINK. Simulation results showed better values for both settling time and overshoot in the case of using neural network based controller than PID.
Źródło:
Control and Cybernetics; 2017, 46, 3; 247-258
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resource-saving technologies of treatment of polluted washing water for transport companies
Ресурсосберегающие технологии очистки загрязненных моечных вод на предприятиях транспорта
Autorzy:
Melekhin, A.
Powiązania:
https://bibliotekanauki.pl/articles/375493.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
contaminated washing water
saving technologies
selective water treatment methods
simulation of the scavenging process
optimization of process parameters
transport company
zanieczyszczona woda do mycia
technologie oszczędzania
wybrane metody uzdatniania wody
symulacja procesu oczyszczania
optymalizacja parametrów procesowych
przedsiębiorstwo transportowe
Opis:
Dedicated to the development of resource-saving polluted washing water treating technologies for transport companies. The article suggests methods of water purification with regard to scientifically grounded requirements to the quality of the water used and the required degree of purification and The article also considers the method of selecting efficient methods of sewage water treating, when a selective removal of individual polluting ingredients should be done. For this purpose we have conducted a simulation process of treating polluted washing water in the circulating water systems, and provided solutions for refining the process parameters.
Посвящено разработке ресурсосберегающих технологий очистки загрязненных моечных вод на предприятиях транспорта. В статье рассмотрены методы очистки воды с учетом научно-обоснованных требований к качеству используемой воды и необходимой степени очистки и методики подбора селективных рациональных методов очистки сточных вод, когда удаление отдельных ингредиентов общего загрязнения происходит избирательно. Проведено моделирование процесса очистки загрязненных моечных вод в оборотных системах водопользования и даны решения задач оптимизации параметров процесса.
Źródło:
Transport Problems; 2016, 11, 1; 131-145
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Założenia technologiczne systemu sterowania procesami koagulacji i flotacji ciśnieniowej w układzie oczyszczania wody
Technological assumptions of coagulation and dissolved air flotation control system in water treatment process
Autorzy:
Kłos, M.
Powiązania:
https://bibliotekanauki.pl/articles/237854.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
water treatment
turbidity
water quality
process control
oczyszczanie wody
mętność
absorbancja w nadfiolecie
sterowanie
Opis:
Based on technical and laboratory scale study results, design recommendations for coagulation and dissolved air flotation control system in water treatment train with high quality variability were presented. Hydrolyzing coagulants, when applied, were demonstrated to require fluent rotational stirrer speed regulation in flocculators. This allows maintenance of adequate floc size which determines bubble-floc agglomerate formation efficacy and their resistance to mechanical tension in the contact zone of flotation tank. In practice, real time rotation regulation in flocculators might be applied, depending on water turbidity or particle number in water fraction leaving flotation tank. Required recirculation factor might be estimated in real time, based on the clarified water quality. However, this solution is very difficult to implement due to many factors that affect efficiency of coagulation and dissolved air flotation processes. It was demonstrated that special attention should be paid to differentiation between the effect of inadequate coagulant dose and the improper recirculation factor. Use of information on the amount and type of suspensions in the intake water, obtained based on UV-absorbance and turbidity measurements, appears to be a better approach.
Na podstawie wyników badań wykonanych w skali laboratoryjnej i technicznej przedstawiono zalecania do projektowania systemu sterowania koagulacją i flotacją ciśnieniową w układzie oczyszczania wody o dużej zmienności jakościowej. Wykazano, że w przypadku stosowania koagulantów hydrolizujących konieczne jest zastosowanie płynnej regulacji prędkości obrotowej mieszadeł w komorach flokulacji. Pozwala to na utrzymanie odpowiedniej wielkości kłaczków, od czego zależy skuteczność powstawania aglomeratów flotacyjnych oraz ich wytrzymałość na naprężenia mechaniczne występujące w strefie kontaktu komory flotacji. W praktyce możliwe jest zastosowanie regulacji obrotów w komorach flokulacji w czasie rzeczywistym w zależności od mętności wody lub liczby cząstek w wodzie opuszczającej komorę flotacji. Wartość wymaganego stopnia recyrkulacji może być określana w czasie rzeczywistym w oparciu o jakość wody sklarowanej. Jednak jest to rozwiązanie bardzo trudne w realizacji z uwagi na to, że na sprawność działania procesów koagulacji i flotacji ciśnieniowej wpływa zbyt wiele czynników. Wykazano, że szczególną uwagę należy zwrócić na rozgraniczenie wpływu nieodpowiedniej dawki koagulantu oraz niewłaściwego stopnia recyrkulacji. Wydaje się, że lepszym rozwiązaniem jest wykorzystanie informacji o ilości i rodzaju zawiesin obecnych w ujmowanej wodzie, uzyskanych na drodze pomiaru absorbancji w nadfiolecie i mętności.
Źródło:
Ochrona Środowiska; 2013, 35, 3; 39-43
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Failure of the side-stream deammonification process. Risk of violation of the WWTP effluent quality
Autorzy:
Janiak, J.
Miodoński, S.
Muszyński-Huhajło, M.
Powiązania:
https://bibliotekanauki.pl/articles/207349.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
activated sludge process
effluents
wastewater treatment
water quality
proces osadu czynnego
ścieki
oczyszczanie ścieków
jakość wody
Opis:
Stable and efficient nitrogen removal is one of main goals of wastewater treatment. Applying deammonification, beyond many advantages, results in the risk of the WWTP effluent quality violation in case of the failure of the process. Then nitrogen load to activated sludge is increasing rapidly which could therefore lead to quality violation in activated sludge effluent. Simulation studies have been presented on the effect of deammonification failure on nitrogen removal performance in the case of a typical, medium sized WWTP (ca. 115 000 PE). The studies were based on the calibrated ASMI model of real WWTP and a fictional scenario of implementing deammonification and subsequent failure. Implementing deammonification enables SR T optimization of the sludge retention time (SRT) in its main line thanks to lower nitrogen load. Two scenarios have been shown, considering or not optimization of the SRT in WWTP. The results show that SRT optimization leads to decrease in nitrifier mass and raises difficult issues in appropriate nitrogen concentration in the effluent.
Źródło:
Environment Protection Engineering; 2018, 44, 2; 169-179
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quality assurance in the technology process of water treatment
Autorzy:
Ingaldi, M.
Jagusiak-Kocik, M.
Powiązania:
https://bibliotekanauki.pl/articles/114869.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
drinking water
water treatment processes
water supply
production process depicted technologically
Ishikawa diagram
woda pitna
uzdatnianie wody
zaopatrzenie w wodę
przedsiębiorstwo wodociągowe
zarządzanie jakością
Opis:
The chapter presents basic information about drinking water. Briefly water treatment processes have been characterized. We analyzed the water company. One of the water intakes of water treatment by the method of biological denitrification and its disinfection by ozonation, the pump station and treatment plant located in the province of Silesia. Process of water treatment for human consumption depicted technologically was presented. The identification of the problem of failure of water supply based on Ishikawa diagram was made. Key words: drinking water, water treatment processes, water supply, production process depicted technologically, Ishikawa diagram was made.
Źródło:
Zeszyty Naukowe. Quality. Production. Improvement; 2014, 1 (1); 35-44
2544-2813
Pojawia się w:
Zeszyty Naukowe. Quality. Production. Improvement
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of a treatment process on the reaction to water of durable and water resistant wood/plastic composites
Autorzy:
Hosseinihashemi, S.K.
Badritala, A.
Powiązania:
https://bibliotekanauki.pl/articles/52280.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Drewna
Tematy:
wooden-plastic composite
treatment process
long-term water absorption
water absorption
water resistance
durability
zinc borate
Źródło:
Drewno. Prace Naukowe. Doniesienia. Komunikaty; 2017, 60, 200
1644-3985
Pojawia się w:
Drewno. Prace Naukowe. Doniesienia. Komunikaty
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies