Tytuł:
Bacteriological quality assessment of two sources of water supplies in Mubi, North-eastern Nigeria
Autorzy:
Tula, M. Y.
Onyeje, G. A.
John, A.
Powiązania:
https://bibliotekanauki.pl/articles/1162572.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Bacteriological
Coliform
Heterotrophic plate count
Mubi
water supplies
Opis:
Water is essential for all life forms and the provision of safe drinking water to the populace cannot be overemphasized. This study examined the bacteriological quality of two sources of water supplies in Mubi, North-eastern Nigeria. A total of 72 water samples were analysed. These include 30 from 10 brands of sachet water and 42 from 21 boreholes in seven different wards of Mubi. Heterotrophic plate count (HPC) was determined by pour plate technique and the total coliform count was determined by 3-3-3 regimen using most probable number (MPN) technique. Escherichia coli and other isolates were identified by standard protocols. The mean HPC for both borehole and sachet water samples were variable and ranged from 3.3 × 102 – 4.7 × 104 cfu/ml for sachet water and 1.1 – 6.0 × 104 cfu/ml for borehole water samples. The HPC of borehole water samples were significantly higher than those of sachet water (P = 0.006). The results showed that the mean MPN index for sachet water samples from brand HCM, KGN, OYM and YNS were zero (0). Brand UDS had the highest mean MPN index (1966.7), while other brands had low mean MPN index that ranged from 3.0 -9.1. In the same vein, the mean MPN index of borehole water samples were high, variable and ranged from 3.7 – 1750. Statistically, the mean MPN index/100ml of borehole water samples were significantly higher than those of sachet water samples (P = 0.006). A total of 49 non-repetitive bacterial species were isolated from the two sources of water. These include E. coli (30), Enterobacter spp (3), P. aeruginosa (5) and Citrobacter spp (11). The distributions of bacterial isolates from the two sources of water showed that E. coli was detected in two brands of sachet water SDK and DYJ and 20 representative boreholes in all the locations, while other organisms were variably distributed. The presence of these organisms constitutes public health significance.
Źródło:
World Scientific News; 2018, 111; 100-110
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Private for-profit rural water supply in Nigeria: Policy constraints and options for improved performance
Prywatne, komercyjne zaopatrzenie w wodę w Nigerii: ograniczenia polityczne i możliwości lepszego funkcjonowania
Autorzy:
Obeta, Michael Chukwuma
Powiązania:
https://bibliotekanauki.pl/articles/292520.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
improved performance
Nigeria
policy constraints
private water supplies
public water schemes
rural communities
możliwości poprawy funkcjonowania
ograniczenia polityczne
prywatne dostawy wody
publiczne systemy wodne
społeczności wiejskie
Opis:
Water scarcity is a major and growing problem in Nigerian rural areas, leading to the emergence of private for-profit water services providers (PPWSPs). This paper characterizes the landscape of PPWSPs in Nigerian rural communities using information collected from field observations, in-depth interviews, questionnaire surveys, and from published water resources literature. The data collected were analysed through the use of descriptive statistical tools. The results revealed the characteristics, categories, contributions and concerns of water users regarding water supplies by PPWSPs. Responses show that PPWSPs are helping to engender development, guarantee end-users with access to sufficient and reliable supplies and reduce water shortages in the study communities. Sixty four percent of sampled households depend on PPWSPs for their water requirements. Many PPWSPs operate outside the purview of government regulations and have differentiated service modes and prizes to gain wider acceptability. Despite the progress made by PPWSPs, however, the strategy can neither guarantee universal access nor the supply of safe drinking water. Significant barriers to the operations of PPWSPs, how to close the policy-gaps that constrain services delivery by PPWSPs and improve performances through setting of standards and regulatory reforms are discussed.
Niedostatek wody jest głównym i narastającym problemem na wiejskich obszarach Nigerii, przyczyniając się do powstawania prywatnych, komercyjnych dostawców wody (PPWSPs). W niniejszej pracy scharakteryzowano usytuowanie prywatnych dostawców w wiejskich społecznościach Nigerii na podstawie informacji zdobytych w obserwacjach terenowych, wywiadach, ankietach i pochodzących z literatury tematu. Zgromadzone dane analizowano za pomocą opisowych narzędzi statystycznych. Wyniki ujawniły charakterystyki, kategorie, udział i obawy odbiorców wody co do dostaw realizowanych przez dostawców. Odpowiedzi świadczą, że firmy te wspierają rozwój, gwarantują odbiorcom wystarczający i niezawodny dostęp do zasobów wody i zmniejszają ograniczenia w tym dostępie wśród badanych społeczności. Zapotrzebowanie na wodę jest zaspokajane przez PPWSPs w 64% analizowanych gospodarstw domowych. Wiele takich firm działa poza zakresem rządowych regulacji i realizuje zróżnicowane sposoby dostarczania usług i ustalania cen, aby osiągnąć szerszą akceptację. Mimo postępu dokonanego przez PPWSPs, taka strategia nie gwarantuje powszechnego dostępu do wody ani dostaw bezpiecznej wody pitnej. W pracy przedyskutowano znaczące ograniczenia w działaniach dostawców wody, sposoby wypełnienia luk prawnych, które ograniczają usługi świadczone przez te firmy, oraz sposoby ulepszenia ich funkcjonowania poprzez ustanowienie standardów i regulacji prawnych.
Źródło:
Journal of Water and Land Development; 2019, 41; 101-110
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of discharged industrial effluents on the parameters of surface water in Onitsha urban area, southeastern Nigeria
Wpływ zrzucanych ścieków przemysłowych na parametry wód powierzchniowych na obszarze miejskim Onitsha w południowowschodniej Nigerii
Autorzy:
Obeta, Michael C.
Okafor, Uchenna P.
Nwankwo, Cletus F.
Powiązania:
https://bibliotekanauki.pl/articles/293086.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
drinking water supplies
industrial effluents
streams contamination
water quality
jakość wody
ścieki przemysłowe
zanieczyszczenie strumieni
źródła wody pitnej
Opis:
Chemical industries in Onitsha urban area of southeastern Nigeria have been discharging large quantities of effluents into surface streams. These streams are the primary sources of water used by poor households for domestic purposes. This study examines the effects of effluents on the physicochemical and microbiological characteristics of the recipient streams. This objective was achieved by collecting eight effluents and twenty-two water samples from control points, discharge locations and exit chutes of the effluents for analysis. The results of the study characterised the effluents and their effects on the recipient streams. The effluents cause gross pollution of the streams as most of the parameters including pH, total dissolved solids (TDS), turbidity, biological oxygen demand (BOD), chemical oxygen demand (COD), Mg, NO3, Fe, Cu, Pb, Cr, total heterotrophic count (THC) and total coliform group (TCG) returned high values that exceeded the World Health Organisation’s (WHO) benchmark from 2011 for drinking water quality. Only dissolved oxygen (DO), Na, Zn, Ca, and Na returned values lower than the WHO guideline. E. coli was found in all the samples; TCG was also high. This paper, therefore, recommends that the effluent generating industries should treat their effluents before disposal.
Przemysł chemiczny na obszarze miejskim Onitsha w południowowschodniej Nigerii odprowadza duże ilości ścieków do strumieni. Strumienie te są podstawowym źródłem wody dla ubogich gospodarstw domowych. W pracy analizowano wpływ ścieków przemysłowych na fizyczne, chemiczne i mikrobiologiczne właściwości wody w strumieniach. Cel ten osiągnięto, pobierając próby wody do analiz z 8 odpływów, z 22 punktów kontrolnych i miejsc zrzutu. Wyniki charakteryzują odpływy i ich wpływ na wody odbiornika ścieków. Zrzuty ścieków powodowały znaczne zanieczyszczenie strumieni, ponieważ większość parametrów (pH, zawiesiny, mętność, BZT, ChZT, Mg, NO3, Fe, Cu, Pb, Cr, suma bakterii heterotroficznych, bakterie grupy coli) przekraczała normy jakości wody pitnej ustalone przez WHO w 2011 r. Jedynie stężenie rozpuszczonego tlenu, Na, Zn, Ca i Na spełniały te normy. Obecność E. coli stwierdzano we wszystkich próbkach, duże były także wartości stężenia bakterii grupy coli. Zaleca się, aby zakłady przemysłowe poddawały ścieki oczyszczaniu przed ich zrzutem do strumieni.
Źródło:
Journal of Water and Land Development; 2019, 42; 136-142
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przyczyny zmian w dopływie wody do Centralnej Pompowni Bolko w Bytomiu
The background of changes in water supply to the Bolko Central Pumping Station in Bytom
Autorzy:
Kropka, J.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/164791.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
niecka bytomska
zlikwidowane kopalnie rud Zn-Pb
Centralna Pompownia Bolko
dopływy wody
Bytom Basin
liquidated Zn-Pb ore mines
Bolko Central Pumping Station
water supplies
Opis:
W 2016 r. minął dwudziesty ósmy rok pracy centralnego systemu odwadniania wyrobisk górniczych pięciu zlikwidowanych kopalń rud cynku i ołowiu w niecce bytomskiej. Sumaryczne dopływy wody do centralnej pompowni wahały się od 15,5 m3/min (2016) do 39,0 m3/min (1997). W wieloleciu 1989-2016 średni dopływ wody do pompowni wynosił 26,2 m3/min i był niższy o około 10,0 m3/min od wielkości prognozowanej, równej 36,0 m3/min. We wspomnianym wieloleciu wydzielono osiem okresów, różniących się wielkościami dopływów do systemu. Wysokie dopływy: 38,6-39,0 m3/min, 30,3-30,4 m3/min i 36,3-29,6 m3/min przypadły na lata: 1996-1997, 2001-2002 i 2010-2011. Niższe dopływy: 19,4-23,8 m3/min oraz 15,5-22,7 m3/min przypadły na lata 2003-2009 i 2012-2016. Przyczynami niższych dopływów wody do pompowni w ostatnim okresie były: niskie opady atmosferyczne, zmiany w gospodarce wodno-ściekowej w zlewni Rowu z Dąbrówki Wielkiej w południowo-wschodniej części Piekar Śląskich oraz likwidacja niektórych źródeł przesączania wody z powierzchni terenu w górotwór triasowy. Wyjaśnienie przyczyn zmian w dopływie wody do pompowni jest bardzo ważne w kontekście prognozowania maksymalnej możliwej wielkości dopływu wody do zlikwidowanych kopalń rud oraz ewentualnej zmiany sposobu pompowania wody w centralnej pompowni.
In 2016 it has already been 28 years since the central system of water drainage in mine workings of five liquidated zinc and lead ore mines in Bytom Basin started. Summaric water inflow to the central pumping station ranged from 15.5 m3/min (2016) to 39.0 m3/min (1997). In the years 1989-2016 the average water inflow was 26.2 m3/min and was lower by ca. 10.0 m3/min from the forecasted value, which was estimated at 36.0 m3/min. In the mentioned period there were eight intervals distinguished, in which the amount of water inflow to the system was different. High inflow: 38.6- 39.0 m3/min, 30.3-30.4 m3/min and 36.3-29.6 m3/min were reported in the years: 1996-1997, 2001-2002 i 2010-2011. Lower inflows: 19.4-23.8 m3/min and 15.5-22.7 m3/min were reported in the years 2003-2009 and 2012-2016. Among the reasons for lower inflows to the pumping station in the last period were: low precipitation, changes in water supply and sewage disposal in the basin of Ditch from Dąbrówka Wielka in south-east part of Piekary Śląskie and liquidation of some sources of water infiltration from the surface to the Triassic mountain formation. Explanation of reasons for changes in water supply to the pumping station is very important in the context of forecasting maximum possible amount of water supply to the liquidated ore mines and possible change in the method of water pumping to the station.
Źródło:
Przegląd Górniczy; 2018, 74, 12; 1-8
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zaopatrzenie w wodę w sytuacjach kryzysowych - zapewnienie mieszkańcom gmin bezpieczeństwa dostaw
Water Supplies in Crisis Situations – Ensuring Security of Supplies to Inhabitants of Local Communities
Autorzy:
KRAMARCZYK-ROSIAK, KSYMENA
URBAN, ARTUR
Powiązania:
https://bibliotekanauki.pl/articles/34602484.pdf
Data publikacji:
2024-06
Wydawca:
Najwyższa Izba Kontroli
Tematy:
bezpieczeństwo dostaw wody w gminach
sytuacje kryzysowe
zaopatrzenie mieszkańców w wodę
water supplies safety in municipalities
crisis situations
providing water to inhabitants
Opis:
Woda jako podstawowe dobro publiczne wymaga specjalnego zarządzania i ochrony oraz bezpiecznego dystrybuowania. Występowanie powodzi, odnotowywane w różnych częściach Polski wypadki skażenia wody bakterią legionelli oraz zagrożenie dla bezpieczeństwa obywateli wynikające z konfliktu zbrojnego w Ukrainie wskazują, że w razie zniszczenia, skażenia lub unieruchomienia infrastruktury wodociągowej konieczne jest zapewnienie mieszkańcom wody pitnej w inny sposób. Wyniki przeprowadzonej w 2023 r. przez NIK kontroli wykazały, że w gminach nie zapewniono bezpieczeństwa zaopatrzenia w wodę na wypadek wystąpienia sytuacji kryzysowych. Nie posiadano wiedzy na temat aktualnych potrzeb i zasobów oraz nie planowano kompleksowych działań w razie wystąpienia zdarzeń mogących istotnie ograniczyć zaopatrzenie w wodę z sieci wodociągowej. Obowiązujące w Polsce przepisy nie określały warunków dostaw wody w takich sytuacjach.
For every inhabitant of a city or village, for every production company or farm (a client of a water supply company) it is necessary to have the feeling of stability and security of water supplies. These are related to the ability to provide water in every conditions, also in crisis situations. In Poland, local authorities (municipalities) are tasked with providing water supplies through water supply companies, on the basis of a licence granted by the local executive body. During the latest audit, the Supreme Audit Office made a comprehensive assessment of water supplies safety in case of a crisis in ten middle-size municipalities in five regions. An assumption was made that planning and preparing of measures to ensure water supplies should be based on a comprehensive assessment of risks of water network failures, on the estimation of the actual needs for water in extraordinary situations, and on the identification and ensuring water resources sufficient to provide the inhabitants with the required amounts of water. The audit comprised the years 2021–2023. The specific topic of the audit called for employing experts in the area of water supplies in crisis situations.
Źródło:
Kontrola Państwowa; 2024, 69, 3 (416); 33-43
0452-5027
Pojawia się w:
Kontrola Państwowa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wymagań dla instalacji wodociągowych przeciwpożarowych w wysokich budynkach mieszkalnych
An Analysis of Water Supply System Requirements to Enhance Fire Safety in High Rise Residential Accommodation
Autorzy:
Drzymała, T.
Kieliszek, S.
Szutkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/372894.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
wymagania dla instalacji wodociągowych
budynki mieszkalne
gaszenie pożarów
systemy gaśnicze
ochrona przeciwpożarowa
requirements for water supplies
residential buildings
firefighting
firefighting systems
fire protection
Opis:
Cel: Celem artykułu jest przedstawienie wymagań dla instalacji wodociągowych przeciwpożarowych, ze szczególnym uwzględnieniem wysokich budynków mieszkalnych oraz wyposażenia tego typu budynków w instalacje przeciwpożarowe, zgodnie z regulacjami zawartymi w aktach prawnych i normach. Wymagania porównano z rzeczywistym zużyciem wody do gaszenia pożarów w tych budynkach na przykładzie m. st. Warszawy. Wskazano problemy związane ze spełnieniem wymagań zawartych w aktach prawnych i normach. Metody: Artykuł opracowano w oparciu o porównanie wymagań dla instalacji wodociągowych przeciwpożarowych w wysokich budynkach mieszkalnych zawartych w przepisach i polskich normach. Porównania dokonano na tle zmian przepisów w ujęciu historycznym. Analizę rzeczywistego zużycia wody do gaszenia pożarów w budynkach mieszkalnych dla m. st. Warszawy przeprowadzono w oparciu o dane statystyczne zawarte w programie „Ewid”, który stanowi wyposażenie każdej jednostki ratowniczo-gaśniczej w Polsce. Wyniki: Na podstawie danych statystycznych można stwierdzić, że wysokość budynku w sposób znaczący wpływa na ilość wody potrzebnej do ugaszenia pożaru. Z danych statystycznych wynika, że na przestrzeni analizowanych lat w budynkach wysokościowych nie odnotowano pożarów dużych i średnich, a w budynkach wysokich wystąpił tylko jeden taki pożar, do którego ugaszenia wystarczyło 0,5 m3 wody. Średnie i duże pożary w zdecydowanej większości występują w budynkach niskich, tzn. o wysokości do 12 m, rzadziej w średniowysokich tzn. o wysokości do 25 m. Ponadto można zauważyć ciekawą zależność, że wraz ze wzrostem wysokości budynku, średnia ilość wody potrzebna do ugaszenia pożaru maleje. Z powyższego wynika, że wskazana jest szczegółowa analiza wysokich wymagań odnośnie wydajności instalacji w wysokich budynkach mieszkalnych. Wnioski: Z analizy danych statystycznych wynika, że wraz ze wzrostem wysokości budynku maleje ilość wody potrzebna do ugaszenia pożaru. Główną przyczyną takiej zależności jest wzrost klasy odporności pożarowej budynku wraz ze wzrostem jego wysokości. Skutkuje to wyeliminowaniem materiałów palnych i zwiększeniem wymagań w zakresie klasy odporności pożarowej. Reasumując, obecnie obowiązujące wymagania zawarte w przepisach dotyczących przeciwpożarowego zaopatrzenia w wodę zapewniają możliwość prowadzenia w budynkach mieszkalnych skutecznych działań ratowniczych. Są one jednak nie do końca dopracowane i należałoby je dostosować do panujących realiów. Wskazana jest nowelizacja rozporządzenia w sprawie ochrony przeciwpożarowej budynków, innych obiektów budowlanych i terenów, w części dotyczącej instalacji wodociągowych w wysokich budynkach mieszkalnych.
Aim: The objective of this paper is to present the requirements of firefighting water supply systems with special focus on high residential buildings and firefighting equipment in such buildings, according to regulations in legal acts and standards. The requirements were compared with real water consumption for firefighting purposes in the buildings based on a Warsaw City case study. The problems associated with fulfilling the requirements contained in legal acts and standards have been indicated. Methods: The paper was developed based on the comparison of requirements for firefighting water supply systems in high residential buildings contained in legal acts and Polish standards. The comparison was made with regards to changes in regulations from the historical perspective. An analysis of actual water consumption for firefighting purposes in residential buildings for Warsaw City was made based on statistical data available from “Ewid” software, a standard resource for every rescue/firefighting brigade in Poland. Results: Based on the statistical data it can be concluded that the height of buildings significantly influences the amount of water consumed for firefighting purposes. It results from the statistical data that no large or medium-sized fires in high buildings were recorded in the analysed years, while in high buildings only one such fire occurred that required only approx. 0.5 m3 of water. Medium-sized and large fires in most cases occurred in small buildings, i.e. at a height below 12 m, more rarely in medium-high buildings i.e. at a height of up to 25 m. Furthermore, an interesting relationship was noted - the higher the building the less amount of water was required to distinguish the fire. It follows from this that a detailed analysis of the strict requirements for the water capacity of installations in high residential buildings is recommended. Conclusions: The analysis of the statistical data showed that with increasing building height of the amount of water required for fire extinguishing decreased. A major reason for such a correlation was the increase in fire resistance class of buildings with increasing height. It reflects the exclusion of flammable materials and an increase in requirements in terms of fire resistance class. Summarising, the current requirements contained in the regulations for firefighting water supply provide the possibility of carrying out effective activities in residential buildings. However, they are not refined, and they should be adjusted to the reality. It is recommended that the regulation on the fire protection of buildings, and other buildings objects and sites be amended in the part related to water supplies in high residential buildings.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 43, 3; 275-284
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies