Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water physico-chemical analysis" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Internal Corrosion Damage Mechanisms of the Underground Ferrous Water Pipelines
Autorzy:
Yeshanew, Desalegn A.
Jiru, Moera G.
Lemu, Hirpa G.
Tolcha, Mesay A.
Powiązania:
https://bibliotekanauki.pl/articles/2201765.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
internal corrosion
water pipes
water physico-chemical analysis
corrosion mechanisms
corrosion mechanism
Opis:
Internal water pipe corrosion is a complicated problem due to the interaction of water quality parameters with pipe wall. This study presents investigations of internal pipe surface corrosion mechanisms related to water physicochemical. Samples of water and corrosion-damaged ductile cast iron (30+ years) and galvanized steel pipe (15-20 years) were collected at in-situ condition from Addis Ababa city water distribution system. Scanning electron microscopy and optical microscopy were used to examine the pipes' corrosion morphology and microstructures, respectively. Additionally, Mountains 9 surface analysis software was used for further pitting corrosion characterization.To identify the causes of internal pipe corrosion, water physicochemical analyses were conducted by using inoLab pH 7310P, DR 900, Palintest Photometer 7100, and Miero 800. Water physicochemical test indicates: CaCO3 is 77 - 215 ppm, pH is 7.05 – 7.86, total dissolved solids (TDS) is 84.10 -262.8 ppm, ClO2 is 0 – 0.5 ppm, and dissolved oxygen (80-81 ppb). From water test results, major causes of internal pipe corrosion damage mechanisms were identified as dissolved oxygen, CaCO3, TDS, ClO2,and resistivity of water which initiates a differential cell that accelerates pipe corrosion. Using Mountain 9 surface analysis software, corrosion morphology and pitting features were characterized. The outputs of this paper will be helpful for water distribution and buried infrastructure owners to investigate corrosion damage mechanisms at early stage. To manage corrosion mechanisms, water supply owners need to conduct frequent inspections, recording of pipe data, testing of water quality, periodic pipelines washing, and apply preventative maintenance.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 3; 111--123
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physico-Chemical Properties of Sri Sanishwaran Temple Pond Water, Tirunallar
Autorzy:
Ganesh, K. Sankar
Xavier, R. Lawrence
Nagarajan, M.
Sundaramoorthy, P.
Powiązania:
https://bibliotekanauki.pl/articles/1193934.pdf
Data publikacji:
2015
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Devotees
Physico-chemical properties
Saneshwaran temple
Water analysis
Opis:
Tirunallar Saniswaran Temple dedicated to Lord Darbaranyeswaran, a form of Lord Shiva. Temple management imposes restrictions over misuse of these holy ponds. The devotees use the holy water for washing their limbs before entering the temple. Sometimes they make a holy dip into the water; people believe that it can wash all their sins away. Thousands of devotees visit the temple. So, the present investigation deals with the physiochemical properties of Sri Saneeshwaran temple pond water. Analysis of water samples revealed that the physico chemical properties such as pH , Electrical conductivity, Total hardness (mg/l), Ca hardness (mg/l), Mg hardness (mg/l), BOD (mg/l), Total Dissolved solids (mg/l), Suspended solids (mg/l), Chlorides (mg/l), Sulphate (mg/l), Sodium (mg/l), Potassium (mg/l), Dissolved Oxygen (mg/l) and Oil & grease (mg/l)., is varied significantly. Similarly the bacterial load is higher in after mass bathing than in before mass bathing.
Źródło:
World Scientific News; 2015, 21; 1-11
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spatial Variability Analysis of Some Groundwater Physico-Chemical Parameters in Parts of Akwa-Ibom State, Nigeria
Autorzy:
Emujakporue, Godwin O.
Ngwueke, Marcel I.
Powiązania:
https://bibliotekanauki.pl/articles/1191777.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Water analysis
Akwa Ibom
Physico-chemical parameters
Semi-variogram
Kriging
Opis:
The groundwater physico-chemical parameters of Parts of Akwa Ibom state and their spatial distribution have been examined in this study. The physico-chemical parameters analysed are Ph, total dissolved solids, electrical conductivity and water hardness. The average pH, electrical conductivity, water hardness and total dissolved solids obtained are 6.4, 163.4242 μS/cm, 83.81 mg/l and 90.5 mg/l respectively. The computed values are within the permissible limit set by World Health Organisation (WHO). Semi-variogram and ordinary kriging were used for the spatial distribution analysis. The semi variogram of the pH, total dissolved solids, electrical conductivity and water hardness were model with Gaussian, spherical, linear functions respectively. The pH map is dominated with values ranging from 6.2 to 6.6 while the total dissolved solids map is associated mainly with values ranging from 90 to 95 mg/l. The water hardness and electrical conductivity values increases from central part toward the west and eastern regions. The geostatical modelling has been used to estimate the values of the parameters at unsampled points.
Źródło:
World Scientific News; 2016, 50; 20-32
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elucidation of tidal spatial-temporal variation of physico-chemical and nutrient parameters of estuarine water at South Gujarat
Autorzy:
Desai, Nisheeth C.
Kukadiya, Nipul B.
Mehta1, Jignasu P.
Godhani, Dinesh R.
Lakhmapurkar, Jayendra
Dave, Bharti P.
Powiązania:
https://bibliotekanauki.pl/articles/1030123.pdf
Data publikacji:
2020
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Estuary water
Nutrients
Physico-chemical parameters
Principal component analysis
Tidal variation
Opis:
In the present study, the four estuaries were selected from the South Gujarat region to appraise the impact of industrial pollution in the estuarine water samples. The study focused on the tidal variation of nutrients, which disclosed that concentrations of NO2–N, NO3–N, NH4–N, TN, and reactive silicates were higher in low-tide whereas pH, salinity, and dissolved oxygen were higher in high-tide water samples. The results of high BOD and low DO expose the anthropogenic inputs in these estuaries during the low-tide. The results of physico-chemical and nutrients parameters of water showed that the pollution level is strongly influenced by tidal and seasonal changes. Pearson’s correlation matrix and principal component analysis (PCA) are applied to a hydrological and hydrographical dataset for finding the spatial-temporal variation during the tidal difference. This study suggested that there is an impact of industrial pollution and anthropogenic inputs on the estuarine water of the study area.
Źródło:
World Scientific News; 2020, 143; 79-102
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The hydrocarbon impurity of mineral waters and soils in Iwonicz-Zdrój
Zanieczyszczenie substancjami węglowodorowymi wód mineralnych i gleb w Iwoniczu�-Zdroju
Autorzy:
Lipińska, E.
Powiązania:
https://bibliotekanauki.pl/articles/410211.pdf
Data publikacji:
2012
Wydawca:
STE GROUP
Tematy:
gleba
woda
źródła wód mineralnych
analiza fizykochemiczna
soil
water
mineral water springs
analysis of physico-chemical
Opis:
The commune of Iwonicz�-Zdrój is a spa commune. The co�]occurrence of springs of mineral water with sources of hydrocarbon substances is characteristic of the commune. The natural emissions of hydrocarbons poses a risk of their continuous or pulsed entering into soil and water. The zone A of the health resort protection is to meet the specific requirements of environmental protection. In this zone, samples of soil and underground water were taken for laboratory tests. Substances exceeding the standards of environmental quality were fixed.
Gmina Iwonicz-Zdrój jest gminą uzdrowiskową. Cechą charakterystyczną dla gminy jest współwystępowanie źródeł wód mineralnych ze źródłami substancji węglowodorowych. Naturalna emisja substancji węglowodorowych stwarza ryzyko ciągłego lub pulsacyjnego przedostawania się ich do środowiska gruntowo-wodnego. Strefa A ochrony uzdrowiskowej ma spełniać szczególne wymagania ochrony środowiska. W strefie tej pobrano próbki gleby i wody podziemnej do badań laboratoryjnych. Oznaczono substancje przekraczające standardy jakości środowiska.
Źródło:
Management Systems in Production Engineering; 2012, 2 (6); 32-38
2299-0461
Pojawia się w:
Management Systems in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies