Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water microbiology" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
The quality and importance of groundwater in the escarpment zone of the Bug river valley
Jakość i znaczenie wód gruntowych w strefie krawędziowej doliny Bugu
Autorzy:
Wołyńczuk, K.
Rogóż-Matyszczak, A.
Zarębska, M.
Zbucki, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/2053979.pdf
Data publikacji:
2020
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
hydrology
groundwater
water microbiology
wells
water geochemistry
hydrologia
wody podziemne
mikrobiologia wód
studnie
geochemia wód
Opis:
Background. The use of groundwater from private wells in households is increasing significantly. However, this water is usually untreated, making it a carrier of diseases. Chemical composition plays a key role in assessing groundwater quality. Due to rapid urbanization and industrialization of the environment, pollutants (especially toxic elements) are constantly being released into the aquatic environment and pose a threat to human and animal health. There is a large variety of microorganisms in aquifers. The use of groundwater from aquifers as sources of drinking water without water treatment or disinfection is a public health problem. Material and methods. The material for the study consisted of water samples taken from used and unused domestic wells in villages located in Lubelskie Province, Biała Podlaska County, Janów Podlaski municipality, Poland. ICP-OES was used to determine the composition of elements. The total number of mesophilic and psychrophilic bacteria was determined for 5 wells using the pour-plate method according to the Polish Standard PN-EN ISO 6222:2004. Results. The water from the wells is unfit for consumption due to high microbiological contamination. A study would have to be carried out on the content of specific pathogenic microorganisms. In most of the samples analyzed, the heavy metal content of the water is below admissible limits. Conclusions. Water resources of the highest quality should be increasingly protected and retained as drinking water reserves. This is extremely important in view of the progressing climate change and the slow process of groundwater renewal.
Wprowadzenie. Zużycie wody gruntowej ze studni prywatnych w gospodarstwach domowych znacznie wzrasta. Jednakże woda ta jest zwykle nieoczyszczona, co czyni ją nośnikiem chorób. W ocenie jakości wód podziemnych kluczową rolę odgrywa skład chemiczny. Z powodu szybkiej urbanizacji i uprzemysłowienia środowiska, zanieczyszczenia (zwłaszcza toksyczne pierwiastki) są stale uwalniane do środowiska wodnego i stanowią zagrożenie dla zdrowia ludzi i zwierząt. W warstwach wodonośnych występuje duża różnorodność mikroorganizmów. Problemem zdrowia publicznego jest wykorzystywanie warstw wodonośnych wód podziemnych jako źródeł wody pitnej bez procesu oczyszczania wody lub dezynfekcji. Materiał i metody. Materiał do badań stanowiły próby wody pobrane z użytkowanych i nieużytkowanych studni przydomowych we wsiach położonych w województwie lubelskim, powiecie bialskim, w gminie Janów Podlaski. W celu oznaczenia zawartości pierwiastków wykorzystano metodę ICP-OES. Dla 5 studni określono ogólną liczbę bakterii mezofilnych i psychrofilnych przy wykorzystaniu metody płytek lanych zgodnie z Polską Normą PN-EN ISO6222:2004. Wyniki. Woda pochodząca ze studni nie nadaje się do spożycia z uwagi na wysokie zanieczyszczanie mikrobiologiczne. Konieczne byłoby przeprowadzenie badania na zawartość konkretnych mikroorganizmów chorobotwórczych. W większości analizowanych prób zawartość metali ciężkich w wodzie znajduje się poniżej dopuszczalnej granicy. Wnioski. Zasoby wodne o najwyższej jakości powinny być poddane coraz większej ochronie i pozostawione jako rezerwa wód pitnych. Jest to niezwykle istotne z uwagi na postępującą zmianę klimatu oraz powolny proces odnawiania wód podziemnych.
Źródło:
Health Problems of Civilization; 2020, 14, 4; 320-326
2353-6942
2354-0265
Pojawia się w:
Health Problems of Civilization
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of activities aimed at preventing microbiological risks in dental practice
Ocena działań ukierunkowanych na zapobieganie zagrożeniom mikrobiologicznym w pracy stomatologa
Autorzy:
Szymańska, Jolanta
Sitkowska, Jolanta
Powiązania:
https://bibliotekanauki.pl/articles/2168396.pdf
Data publikacji:
2014-10-29
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
sprzęt stomatologiczny
mikrobiologia wody
kontrola infekcji
dental equipment
water microbiology
infection control
Opis:
Background: Microbiological contamination of water in dental unit waterlines (DUWL) creates a risk of cross-infections, and is a source of biological risk factors in the work environment of a dentist. The aim of the study was to evaluate dentists' knowledge on DUWL microbiological contamination and the scope of activities/procedures they undertake to monitor it. Material and Methods: The questionnaire survey was conducted in 2010 among 107 Polish dentists using dental units in everyday clinical practice. Results: It has been found that in their daily practice, dentists do not follow procedures leading to reduction or elimination of microbiological contamination of dental unit reservoir water. They are not aware of microbiological contamination of DUWL that supply working handpieces with water. They are unaware of the principles of dealing with dental water and water supply systems or the health risk posed by microbiological contamination of unit water for a dental team and patients. Conclusions: It is necessary to provide dentists with information on microbiological contamination of water in dental units, on the correct procedures of handling water and waterlines that supply working handpieces with water. Med Pr 2013;64(1):11–17
Wstęp: Mikrobiologiczne skażenie wody w instalacji wodnej unitów dentystycznych stwarza zagrożenie zakażeniami krzyżowymi, stanowiąc źródło szkodliwych czynników biologicznych w środowisku pracy stomatologa. Celem badań była ocena wiedzy dentystów na temat skażenia mikrobiologicznego wody z unitów dentystycznych oraz zakresu czynności/procedur, które powinny być podejmowane w celu monitorowania tego skażenia. Materiał i metody: Badanie ankietowe przeprowadzono w 2010 r. wśród 107 polskich stomatologów używających unitów dentystycznych w praktyce klinicznej. Wyniki: W codziennej pracy dentyści nie stosują procedur minimalizujących/eliminujących mikrobiologiczne skażenie wody w zbiornikach unitów dentystycznych. Nie mają oni wiedzy na temat skażenia instalacji wodnej dostarczającej wodę do końcówek roboczych, nie znają zasad postępowania z wodą z unitów ani z instalacją wodną, nie są też świadomi zagrożeń zdrowotnych stwarzanych przez mikrobiologiczne skażenie wody w unitach dla zespołu stomatologicznego i pacjentów. Wnioski: Konieczne jest dostarczenie dentystom informacji na temat problemu mikrobiologicznego skażenia wody w unitach dentystycznych oraz procedur prawidłowego postępowania z wodą w instalacjach wodnych unitów. Med. Pr. 2013;64(1):11–17
Źródło:
Medycyna Pracy; 2013, 64, 1; 11-17
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological Stability of Water after the Biofiltration Process
Autorzy:
Zamorska, J.
Powiązania:
https://bibliotekanauki.pl/articles/124588.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
biofiltration
microbiology of water
biological stability of water
flow cytometry
Opis:
One of the most frequently implemented processes in the water treatment technology is filtration through a biosorption bed. The techniques based on biochemical processes involving bacteria result in obtaining high quality of water. There are a number of different materials used as the filler material for biological filters. Carbon deposits are the most popular, due to their high effectiveness. The problem with the use of this process is the leaching of microorganisms from the biofilm and the biological stability of water thus obtained. There is a need to develop quick methods to assess the microbiological quality of this water. Modern techniques for determining the amount of microorganisms, such as flow cytometry and luminometry may be the right tools. The water collected for testing came from the Water Treatment Station located in the Podkarpackie voivodeship. The microbiological tests carried out in the analyzed water samples collected after the filtration process on granular activated carbon. Both traditional culture method and modern techniques used to determine the number of microorganisms (flow cytometry, luminometric ATP assay) demonstrated an increase in the number of microorganisms in the examined waters (in the water after the filtration process and in the water introduced into the water supply network) after the incubation process for 3 and 7 days at 15 and 22°C.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 234-239
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan mikrobiologiczny wód z krakowskich fontann
Microbiological quality of water from fountains of Krakow
Autorzy:
Grzyb, J.
Fraś, R.
Frączek, K.
Powiązania:
https://bibliotekanauki.pl/articles/127322.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
fontanny
woda
Kraków
mikrobiologia
bakterie
fountains
water
microbiology
bacteria
Opis:
Celem pracy była ocena stanu mikrobiologicznego wody z 6 krakowskich fontann oraz stworzenie na tej podstawie rankingu czystości fontann. Ocena ta obejmowała analizę liczby bakterii psychrofilnych i mezofilnych, bakterii z grupy coli, bakterii grupy coli typu kałowego, Escherichia coli i paciorkowców kałowych. Wyniki zostały odniesione do stosownych aktów prawnych. Wykazano znaczne zanieczyszczenie wody z badanych fontann. W pięciu z sześciu fontann woda była niezdatna do kąpieli, we wszystkich do picia. Najmniej zanieczyszczona była woda z fontanny na pl. Szczepańskim, najbardziej zanieczyszczona z fontann przed Uniwersytetem Rolniczym i w parku Krakowskim.
Public fountains of various architectural forms had already been known in ancient Persia. Their abundance greatly increased in the times of ancient Rome and Greece, where they decorated public gardens, parks and thermal baths. They currently still play an important role as a part of street furniture, but also provide the possibility of cooling down in their vicinity or even in the water from the fountain on hot summer days. The aim of this study was the assessment of microbiological quality of water from 6 fountains of Krakow and the creation of the purity ranking of the Krakow fountains. This assessment included the total number of psychrophilic and mesophilic bacteria, coliforms, fecal coliforms, Escherichia coli and fecal enterococci. The results were referred to the relevant standards. The results of the study demonstrated a significant pollution of water from the analyzed fountains. Water from five of the six fountains was unsuitable for bathing purposes and from all for drinking. Water from the fountain on the Szczepanski Square was the least contaminated, while the most polluted were the ones from the fountains in front of the University of Agriculture and from Krakowski Park.
Źródło:
Proceedings of ECOpole; 2014, 8, 2; 505-511
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Understanding the Synergic Corrosion Issues with Regard to the Water Treatment Station
Autorzy:
Włodarczyk, Renata
Majek, Klaudiusz
Powiązania:
https://bibliotekanauki.pl/articles/125250.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
chlorination
corrosion microbiology
pitting corrosion
synergy effect
water treatment station
Opis:
The paper presents the examples of damage of elements caused by incorrect assessment of pipeline work conditions. The presented damage cases resulted in the need to replace pipelines. This work is an analysis pertaining to the impact of chemical and microbiological synergy of corrosion on stainless steel pipelines. The paper investigates the corrosion mechanisms that may occur under normal operating conditions at each water treatment station, and the methods of counteracting the corrosion were indicated. The analysis of the corrosion mechanisms was formulated taking into account the design stage, – the correctness of the steel grade choice by the designer, the stage of implementation – the most common implementation errors, and the operational stage – optimization of the technological system work and the effects of the introduced changes. The analysis was carried out at a water treatment plant in Poland with a maximum flow of 20,000 m3 a day-1, which draws raw water from deep water intakes and from a surface intake. The treatment technology includes an aeration system (aeration) and a two-stage treatment process using sand and carbon filters. The disinfection process and prophylaxis in the water treatment plant is based on the use of chlorine gas.
Źródło:
Journal of Ecological Engineering; 2019, 20, 6; 90-96
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
River water quality assessment in East Java, Indonesia
Autorzy:
Novita, Elida
Pradana, Hendra A.
Purnomo, Bambang H.
Puspitasari, Amelia I.
Powiązania:
https://bibliotekanauki.pl/articles/1844410.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
Jember Regency
microbiology parameters
physicochemical parameters
pollution index
Bedadung River
water quality monitoring
Opis:
This study aims to assess the water quality and determine the pollution index of the Bedadung River in the urban-area segment of Jember Regency, East Java. The sampling in the urban segment of Jember was conducted in May 2019 at five different locations, namely Slamet Riyadi Street, Mastrip Street, Bengawan Solo Street, Sumatra Street, and Imam Bonjol Street. The pollution index assessment refers to the Decree of the State Minister for the Environment of Indonesia Republic number 115 of 2003. The analysis showed that the parameters of TDS, TSS, pH, COD, BOD, NH3-N, Co, Cd, Cu, Zn, H2S, Cl–, SO4, oil and fats, MBAS, NO2-N, Fe, Pb, F, Cl2, NO3-N, phenol, and As did not exceed the quality standards. The parameters PO4, CN, total coliform, and faecal coliform were found to breach the quality standards at the 5 water sampling points. Total coliform and faecal coliform were the dominant pollutants in this segment. Therefore, the parameters of PO4, total coliform, and faecal coliform were considered as indicators of pollution arising from domestic and agricultural activities. The pollution index values for the five sampling locations ranged from 7.21 to 8.23. These scores indicate that the Bedadung River section that passes through the urban segment in Jember is classified as being in the moderately polluted category. This preliminary rapid assessment is therefore one of the considerations for the management of water quality in the Bedadung River section that passes through the urban area of Jember.
Źródło:
Journal of Water and Land Development; 2020, 47; 135-141
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies