Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water loss" wg kryterium: Temat


Tytuł:
Comparison of Wireless Data Transmission Protocols for Residential Water Meter Applications
Autorzy:
Krzak, Łukasz
Macheta, Jan
Kubaszek, Mateusz
Worek, Cezary
Powiązania:
https://bibliotekanauki.pl/articles/27311961.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
water meter
protocols
Wireless M-Bus
LoRaWAN
Sigfox
NB-IoT
energy consumption
maximum coupling loss
Opis:
This article provides a comparison of various wireless data transmission protocols, such as Wireless M-Bus, Lo- RaWAN, Sigfox, NB-IoT and a newly developed proprietary protocol, studying their performance in the application of batterypowered residential water meters. Key aspects of the comparison include energy consumption, which is analyzed through comparing unitary amount of charge required to conduct a single, bidirectional data transaction between the meter and base station, and maximum coupling loss which effectively defines the range and coverage in the system. For completeness, the study includes also a brief cost analysis and ends with a conclusion, stating when each of the particular standards should be favored.
Źródło:
International Journal of Electronics and Telecommunications; 2023, 69, 4; 833--842
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GAEC 5 Direct Payment System Implementation Challenges in Slovakia
Autorzy:
Pipíšková, Petra
Muchová, Zlatica
Dežerický, Dávid
Michal, Peter
Powiązania:
https://bibliotekanauki.pl/articles/24201744.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water erosion
conditionality
GAEC5
GSAA
CAP EU
DMR 3.5
DMR 5.0
soil loss
Opis:
The Agricultural Payments Agency (supervisory and registry authority) of the Slovak Republic has announced an erosion hazard layer to meet the requirements of GAEC5 (Minimising soil erosion. Limit soil erosion by putting in place suitable practical measures). If a farmer fails to observe the layer data, they will be fined and might lose access to direct subsidies (also known as direct payments). The layer that has been announced raises a number of questions and concerns amongst beneficiaries of direct subsidies and users of land parcels. For instance, with the Pastuchov land parcel, the uncertainties associated with the application of GAEC5 were raised. A comparison of the water erosion layer commitment for 2023 with the erosion calculated by the Universal Soil Loss Equation (USLE) method based on the Digital Relief Model (DRM) generated from airborne laser scanning has confirmed the uniformity in all classified categories of water erosion over a 65% land parcel area. The situation of the land user has been diminished (i.e. they have to comply with GAEC5 even when there is no reason to) over 11% of the area. The situation of the land user has improved over 24% of the area (i.e. they do not have to comply with the conditions even when there is reason to). This paper describes the problems and outlines the possibilities for the necessary adjustment of compliance with the GAEC5 conditions in Slovakia.
Źródło:
Journal of Ecological Engineering; 2023, 24, 6; 109--118
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sprężanie cieczy z odwiertów eksploatacyjnych na powierzchnię z zastosowaniem metody sekwencyjnej aproksymacji
Compression of liquids from the operating wells to the surface applying the sequential approximation
Autorzy:
Akhundova, Nargiz R.
Rzazade, Samad A.
Aliyeva, Ofeliya
Bahshaliyeva, Shirin
Powiązania:
https://bibliotekanauki.pl/articles/31343953.pdf
Data publikacji:
2023
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
underground gas storage
dome-shaped
water pressure
flow contour
operating well
injection wells
pressure loss
gas-water contour
water trap
podziemny magazyn gazu
kształt kopuły
ciśnienie wody
kontur przepływu
odwiert produkcyjny
odwierty zatłaczające
strata ciśnienia
kontur gazowo-wodny
pułapka wodna
Opis:
W artykule omówiono problem wydobywania wody na powierzchnię poprzez zatłaczanie gazu do systemu ciśnieniowego wody zlokalizowanego w obrębie struktury o kształcie kopuły. Warstwa jest całkowicie wypełniona cieczą. Wymaga to utworzenia podziemnych zbiorników gazu w centralnej strefie wyższej części systemu ciśnieniowego wody. W tym celu woda odbierana z otworów odwierconych w strefach zmniejszonego ciśnienia musi być sprężana. W celu rozwiązania problemu stosuje się metodę sekwencyjnej aproksymacji, w wyniku której tworzenie się złoża następuje na skutek sprężania płynu poprzez odwierty robocze. Znane są ciecze i gazy, które wzbogacają system ciśnieniowy wody, system złożowy i jego parametry. System złożowy ograniczony jest wyznaczonymi konturami ciśnienia i przepływu. Z czasem ciśnienie wody w złożu zostało ustalone w wyniku zmiany sumy objętości kawerny w brzeżnej części złoża, pojemności wytworzonego gazu i ilości wtłaczanego gazu. W rozważanych warunkach ruch wody w obszarach ograniczonych konturem odbioru i przepływu ma charakter radialny. Mając na uwadze, że obszar ten nie jest zbyt duży, można zignorować własności elastyczne wody i porowatość zbiornika. Zagadnienie to można rozpatrywać jako filtrację nieściśliwego płynu w niezdeformowanym złożu. Przy stosunkowo niewielkiej zmianie natężenia przepływu, spowodowanej stałym ciśnieniem w obwodzie odbiorczym, woda sprężona przez gaz przepływa swobodnie przez głowicę odwiertu roboczego.
The article discusses the issue of pushing water to the surface by injecting gas into the dome of a water pressure system. The layer is completely filled with liquid. This requires the creation of underground gas storages in the central upper part of the water pressure system. For this purpose, the water must be pressurized from the drilled and unloaded wells. A sequential approximation method is used to solve the problem, and formation of the reservoir occurs due to the compression of the fluid through the operating wells. Fluids and gases that enrich the water pressure system, field system and parameters are known. The boundaries of the latter are the contours of the pressure and the flow. Over time, the water pressure in the reservoir has been determined by changing the sum of the volume of the cavity at the edge of the reservoir, the capacity of the created gas and the amount of injected gas. Under the conditions considered, the movement of water in the areas bounded by the contour of the discharge and flow can be considered as radial. Since this area is not very large, the elasticity of the water and the porosity of the reservoir can be ignored. This issue can be considered as the filtration of incompressible fluid in a nondeformable bed. With a relatively small change in flow rate due to the constant pressure in the discharge circuit, the water compressed by the gas flows freely through the wellhead of the discharge well.
Źródło:
Nafta-Gaz; 2023, 79, 3; 184-189
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
2D Modeling of Wave Propagation in Shallow Water by the Method of Characteristics
Autorzy:
Khalilabadi, Mohammad Reza
Powiązania:
https://bibliotekanauki.pl/articles/31340098.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
wave propagation
shallow water
MOC method
waveguide
transmission loss
Opis:
In this paper, a 2D numerical modeling of sound wave propagation in a shallow water medium that acts as a waveguide, are presented. This modeling is based on the method of characteristic which is not constrained by the Courant–Friedrichs–Lewy (CFL) condition. Using this method, the Euler time-dependent equations have been solved under adiabatic conditions inside of a shallow water waveguide which is consists of one homogeneous environment of water over a rigid bed. In this work, the stability and precision of the method of characteristics (MOC) technique for sound wave propagation in a waveguide were illustrated when it was applied with the semi-Lagrange method. The results show a significant advantage of the method of characteristics over the finite difference time domain (FDTD) method.
Źródło:
Archives of Acoustics; 2022, 47, 3; 407-412
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the intra-annual variability of agricultural soil losses: a RUSLE application in Nord-Pas-de-Calais, France
Autorzy:
Nouaim, Wafae
Rambourg, Dimitri
Merzouki, Mohamed
El Harti, Abderrazak
Karaoui, Ismail
Powiązania:
https://bibliotekanauki.pl/articles/2073744.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
agriculture
Nord-Pas-de-Calais
Revised Universal Soil Loss Equation
RUSLE
water erosion
Opis:
The control of water erosion is an important economic and societal challenge. Reduction of the agronomic potential of the parcels, muddy flows, siltation of dams are harmful consequences that mobilize farmers, water managers, local authorities and scientific researchers. This study focuses on mapping and quantifying seasonal soil losses in the territory of the former Nord-Pas-de-Calais administrative region, using the Revised Universal Soil Loss Equation (RUSLE) which incorporates five factors: rainfall erosivity, soil erodibility, topography, land use and erosion control practices. The seasonal (3-months) time scale is chosen to better account for the parameters governing the soil water erosion, especially rainfall and vegetation cover, that show great asynchronous intra-annual variability. Also, high resolution data concerning agricultural plots allows to evaluate which type of culture are the more subject to soil losses. In Nord-Pas-de-Calais, water erosion occurs almost ubiquitously, but the areas characterized by steep slopes are the most at risk (Artois Hills and Flanders), with loss rates up to 54 t∙ha-1∙y-1. The majority of erosion occurs during fall (46% of the computed annual losses of 1.69∙Mt), on plots left bare after harvest (especially corn and beets crops). The study also demonstrates that extending the intercrop technique over the region, and therefore maintaining a fall and winter cover, could reduce the soil losses by 37%.
Źródło:
Journal of Water and Land Development; 2022, 52; 210--220
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of hydraulic model in real water loss reduction and water distribution network operational cost lowering
Wykorzystanie modelu hydraulicznego w redukcji rzeczywistych strat wody oraz redukcja kosztów eksploatacji sieci wodociągowej
Autorzy:
Zajkowski, Artur
Wysocki, Łukasz
Tuz, Piotr
Bartkowska, Izabela
Kruszyński, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2097397.pdf
Data publikacji:
2022
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
hydraulic modelling
water loss
leakage
cost of exploitation
loss reduction
modelowanie hydrauliczne
strata wody
wyciek
koszt eksploatacji
redukcja strat
Opis:
Most of the small water companies supplying a small number of consumers with water are struggling with the extremely tight budget, often making any large-scale modernisation impossible. In effect network managed by these companies is often very leaky and unreliable. One possible and cheap way of leakage reduction is the reduction of average pressure in the network. Thanks to new computing technologies, the device selection process for pressure reduction is accurate and easy to do. This study uses the hydraulic model to select required pressure reducing valves and correct locations accurately and adequately approximate the resulting absolute water loss reduction thanks to this approach.
Większość małych przedsiębiorstw wodociągowych boryka się z problemami budżetowymi. Mogą mieć one wiele źródeł – obłsuga niewielkiej ilości odbiorców, wysoki poziom strat, konieczność zakupu wody z zewnętrznych źródeł. Czynniki te sprawiają, że wymagane nakłady na modernizacje sieci niejednokrotnie przewyższają możliwości finansowe przedsiębiorstwa. Jednym ze sposobów redukcji rzeczywistych strat wody jest obniżenie średniego ciśnienia w sieci. Dzięki nowym metodom obliczeniowym i symulacjom komputerowym dobór urządzeń redukujących ciśnienie i wybór lokalizacji ich montażu są znacznie ułatwione. W pracy skupiono się na ocenie możliwości wykorzystania modelowania komputerowego podczas wdrażania systemu zarządzania ciśnieniem w sieci wodociągowej.
Źródło:
Ekonomia i Środowisko; 2022, 2; 186--202
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental Effects of Reducing Land Fragmentation in Land Consolidation at West Roztocze at the Slope Scale
Autorzy:
Rybicki, Roman
Powiązania:
https://bibliotekanauki.pl/articles/1839549.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
land consolidation
water erosion
soil loss
loess upland area
Opis:
The paper presents the ecological effects of land consolidation carried out in upland loess areas. The design of a large plot of land on a slope with a gradient of up to 18% and its impact on the intensity of water erosion were investigated. The analyzed plot was created by consolidation 12 smaller plots. Before the consolidation, all plots had a cross-slope layout and direction of agrotechnical operations. Exactly the same arrangement remained after the consolidation. The WEPP simulation model was used for the comparison of the pre-consolidation and postconsolidation state. The amount of soil loss and sediment yield was estimated under different scenarios of slope management. It was found that after consolidation (creation of a plot with the width of more than 130 m), as a result of removing of terraces and sodded cross-slope scarps, the intensity of erosion increased many times. In order to restore the anti-erosion effect of cross-slope cultivation on such a slope without increasing the difficulties of agrotechnics, it is necessary to restore the sodded scarps that existed before consolidation. The simulation results show that the scarps should be located transversely to the slope (along the plot) in the middle and lower parts of the slope, in the place of the highest inclination. As advantage of the consolidation project was considered the elimination of longitudinal balks which were focuses of linear erosion on the slope.
Źródło:
Journal of Ecological Engineering; 2021, 22, 1; 240-248
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Real Water Losses and the Failure of Urban-Rural Water Supply System
Autorzy:
Gwoździej-Mazur, Joanna
Świętochowski, Kamil
Powiązania:
https://bibliotekanauki.pl/articles/1839569.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water loss
water supply system failure
urban-rural water supply system
International Water Association
IWA
water balance
infrastructure leakage index
Opis:
The topic of failures and water losses in the urban-rural water supply network was discussed. The purpose of the work was to assess the level of real water losses and the failure rate of the urban-rural water supply network in 2010-2016. The article’s introduction contains the information on the types and causes of breakdowns in the water supply network. The life cycle of the leakage from its inception to its removal was also described. Next, the methodology and indicators for assessing actual losses in the water supply network were presented according to the guidelines of the International Water Association (IWA), i.e. ILI, CARL, UARL, RLB and water balance. The material and methods chapter describes how to calculate the failure rate. On the basis of the literature review, a method of assessing the failure of the water supply network and the level of actual water losses was presented. The research part presents the results of the water losses indicators values and assesses them against the literature data for the entire urban-rural system. The results of the failure of the water supply of the urban area and the rural area were also presented and compared with the literature data. A method of calculating limit values of the failure intensity index for the entire water supply system was also proposed. The changes in the intensity of failure occurrence during the year were presented. The object described in the studies achieved the A rating according to the classification of ILI and RLB values throughout the entire analysis period (2010–2016). Failure intensity in the analyzed period exceeded the average values calculated for water supply networks in Poland many times. The values in individual cases exceeded the limit values specified in the literature.
Źródło:
Journal of Ecological Engineering; 2021, 22, 1; 132-138
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of excessive solar heat gains on heat loss in the hot water tank – case study
Wpływ nadmiernych uzysków solarnych na straty ciepła z zasobnika cwu – studium przypadku
Autorzy:
Olczak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/282991.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
renewable energy
solar energy
flat plate collector
hot water tank
tank loss coefficient
energia słoneczna
energia odnawialna
płaski kolektor słoneczny
zasobnik ciepłej wody
współczynnik strat ciepła z zasobnika
Opis:
The analysis of a solar installation operation was conducted on the example of a detached house in the Lesser Poland province in Poland. A gas boiler and three flat-plate collectors are located inside the house, which are used for heating water in the hot water tank with a volume of 220 dm3. The installation was established in 2012. The heat measured system (for solar gains) was added in 2014. In 2015–2019 solar heat gains measured per area of absorber were higher than 340 kWh/m2. During a two-week period in June 2015, the insolation on the horizontal plane and the temperature were measured in 4 different points of the hot water tank. On this basis, heat losses from the storage tank were determined, i.e. a decrease in temperature during periods with and without the consumption of hot water by the residents. During this period, a temperature higher than 80°C was observed several times in the hot water tank. In two parts of the hot water tank, rhe determined temperature decreases were used to obtain the heat loss amount. In the analyzed period (2 weeks), 9 days were observed with solar heat gains higher than 9 kWh/day. For these days, the value of heat loss from the solar hot water tank was estimated at over 6 kWh/day. This data corresponds to the actual heat demand for hot water preparation in the building at 7.3 kWh/day. The correlation between daily solar heat gains and solar hot water tank heat losses were also determined. In addition, based on the amount of heat losses, the value of the tank loss coefficient was estimated. The obtained value was compared with the manufacturer’s data and reference data.
Analiza aspektów pracy instalacji solarnej została przeprowadzona na przykładzie domu jednorodzinnego w województwie małopolskim w Polsce. W analizowanym budynku jednorodzinnym znajduje się kocioł gazowy i instalacja solarna złożona z trzech płaskich kolektorów słonecznych. Urządzenia te odpowiadają za przygotowanie ciepłej wody użytkowej magazynowanej w zasobniku o pojemności 210 dm3. Instalacja powstała w 2012 roku, w 2014 roku została opomiarowana pod kątem uzysków solarnych. W latach 2015–2019 mierzono uzyski solarne, były one wyższe niż 340 kWh/m2 powierzchni absorbera. Podczas dwutygodniowego okresu w czerwcu 2015 roku mierzono także natężenie promieniowania słonecznego na płaszczyźnie poziomej i temperaturę w 4 różnych punktach zasobnika ciepłej wody. Na tej podstawie określono straty ciepła z zasobnika, tj. spadek temperatury w zasobniku w okresach z i bez poboru ciepłej wody użytkowej przez mieszkańców. W tym okresie zanotowano temperaturę wyższą niż 80°C w zasobniku tylko przez kilka stosunkowo krótkich okresów. Wyznaczone spadki temperatury w dwóch częściach zasobnika ciepłej wody użytkowej użyto do określenia ilościowych strat ciepła. W analizowanym okresie (2 tygodnie) zaobserwowano 9 dni z uzyskami solarnymi wyższymi niż 9 kWh/dzień. Dla tych dni oszacowano wartości strat ciepła z zasobnika na poziomie powyżej 6 kWh/dzień. Dane te korespondują z rzeczywistym zapotrzebowaniem na ciepło do przygotowania ciepłej wody użytkowej w budynku na poziomie 7,3 kWh/dzień. Określono także zależności między dziennymi uzyskami solarnymi a stratami ciepła z zasobnika (korelacja). Ponadto bazując na wielkościowych stratach ciepła, oszacowano wielkość współczynnika strat ciepła z zasobnika. Uzyskaną wartość porównano z danymi producenta i danymi referencyjnymi.
Źródło:
Polityka Energetyczna; 2020, 23, 2; 91-103
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and Evaluation of Water Losses in the Collective Water Supply System
Analiza i ocena strat wody w wybranym wodociągu grupowym
Autorzy:
Ociepa, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/1812009.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water losses
percentage water loss index
infrastructure leakage index
unit water start index
failure intensity index
straty wody
procentowy wskaźnik wody
infrastrukturalny indeks wycieków
jednostkowe wskaźniki start wody
wskaźnik intensywności uszkodzeń sieci wodociągowej
Opis:
The paper presents the analysis and evaluation of water losses in the distribution system used by the Water and Sewage Company in Końskie, Poland. The analysis of water losses was conducted based on the use of numerous indices that provide objective information on the condition of the water supply system. The method of the percentage water loss index was extended by the methods of determination of water losses according to the International Water Association (IWA). The data needed for the calculation of water losses, such as the amount of water supplied to the network, the water sold, water used for the company's own needs, the length of the network, the number and length of water supply connections, number of customers, mean pressure in the network, and number of failures was derived from Water and Sewage Company in Końskie, Poland. These data were used to calculate the amount of water losses in individual years, percentage water loss index (PWS), and the indices recommended by the International Water Association (IWA): Real Leakage Balance (RLB), Non-Revenue Water Basic (NRWB), Unavoidable Annual Real Losses (UARL), Infrastructure Leakage Index (ILI) and unit indices of loss per capita and per kilometre of network. Due to the likely relationships of the load and failure rate of the network with water losses, the failure intensity index and index of hydraulic load to the network. The results of the analysis showed that with its comprehensive activities, the company has significantly reduced its water losses in recent years. Currently, most of the water loss indices have reached a level considered good compared to the national data and average according to the standards used in Western European countries. In 2012, most of the analysed loss indices were at a high or even very high level and showed higher than the national average loss of network water. The decrease of the NRWB index from 29% in 2012 to ca. 18% in 2018, and the decrease of the ILI value in the respective years from 3.1 to 1.5-1.6 indicate the effective countermeasures used to limit water losses. Currently, the value of IMI according to strict IWA criteria suggests a very good condition of the network. RLB2 is another indicator that fell sharply over the period analysed. In 2012, its value was more than twice as high as at present. On the other hand, the average condition of the network is indicated by the unit water loss index per capita, which amounted to 52.80 in 2012 and currently is about 23.07 dm3/(inhabitant day). Very low values of the failure intensity index of the water supply system indicate that the impact of failures on water losses is insignificant, assuming that the company responds quickly to remove identified leaks and there are no undetected failures. The several years of analysis and evaluation of numerous indices of water loss presented in the paper reveals the effectiveness of the adopted strategies of reducing leakages in the distribution system. It should be noted that the company has been involved in comprehensive activities aimed at limitation of water losses for several years.
W artykule przedstawiono analizę i ocenę strat wody w systemie dystrybucji eksploatowanym przez Przedsiębiorstwo Wodociągów i Kanalizacji w Końskich. Analizę strat wody przeprowadzono w oparciu o liczne wskaźniki pozwalające na obiektywną informację o stanie sieci wodociągowej. Metoda procentowego wskaźnika strat wody rozszerzona została o metody określania strat według International Water Association(IWA). Niezbędne dane do obliczeń strat wody jak: ilość wody dostarczanej do sieci, wody sprzedanej, zużytej na potrzeby własne zakładu, długość sieci, ilość i długość połączeń wodociągowych, liczbę odbiorców, średnie ciśnienie w sieci, liczba awarii otrzymano z Przedsiębiorstwa Wodociągów i Kanalizacji w Końskich. Na ich podstawie wyznaczono: ilość strat wody w poszczególnych latach, procentowy wskaźnik strat wody (PWS), a także zalecane przez International Water Association (IWA) wskaźniki: Real Leakage Balance (RLB), Non-Revenue Water Basic (NRWB), Unavoidable Annual Real Losses (UARL), Infrastructure Leakage Index (ILI) oraz wskaźniki jednostkowe strat na mieszkańca i kilometr sieci. Z uwagi na możliwy związek obciążenia i awaryjności sieci ze stratami wody wyznaczono wskaźnik intensywności uszkodzeń i wskaźnik hydraulicznego obciążenia sieci. Wyniki przeprowadzonej analizy pozwalają stwierdzić, że dzięki wszechstronnym działaniom przedsiębiorstwo w ostatnich latach zdecydowanie obniżyło straty wody. Obecnie większość wskaźników strat wody osiągnęło poziom uznany za dobry na tle danych krajowych a średni w odniesieniu do standardów krajów Europy zachodniej. W 2012 roku większość analizowanych wskaźników strat była na wysokim a nawet bardzo wysokim poziomie i świadczyła o wyższych niż średnie krajowe ubytkach wody z sieci. Spadek wskaźnika strat NRWB z 29% w 2012 roku do ok. 18% w 2018, spadek wartości wskaźnika ILI w tym okresie z 3,1 do 1,5-1,6 świadczy o skutecznym przeciwdziałaniu stratom wody. Obecnie wartość ILI według rygorystycznych kryteriów IWA świadczy o bardzo dobrym stanie sieci. Kolejnym wskaźnikiem, który uległ w analizowanym okresie poważnemu obniżeniu jest RLB2. W 2012 wartość jego była ponad dwukrotnie wyższa niż obecnie. Natomiast na średni stan sieci wskazuje jednostkowy wskaźnik strat wody na mieszkańca, który wynosił 52,80 w 2012 roku a obecnie ok. 23,07 dm3/(mieszkańca/dobę). Bardzo niskie wartości wskaźnika intensywności uszkodzeń sieci wodociągowej wskazują na mało znaczący wpływ awarii na straty wody przy założeniu, że Zakład szybko reaguje i usuwa stwierdzone wycieki i nie występują awarie nieujawnione. Analiza i ocena na przestrzeni lat licznych wskaźników strat wody przedstawiona w artykule świadczy o skuteczności przyjętych strategii ograniczania wycieków w systemie dystrybucji. Należy podkreślić, że przedsiębiorstwo od kilku lat prowadzi wszechstronne, kompleksowe działania zmierzające do ograniczania strat wody.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 1021-1039
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Minimum Pressure Drop Caused by the Condensation of Water Vapor in the Cooled Air Flowing in the Inclined Conduit
Minimalna strata ciśnienia spowodowana kondensacją pary wodnej w chłodzonym powietrzu płynącym przewodem nachylonym
Autorzy:
Ptaszyński, Bogusław
Kuczera, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/318286.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
dwufazowy przepływ bezpoślizgowy
strata ciśnienia
charakterystyka przewodu
masowe źródła wody z kondensacji pary wodnej
two-phase no-slip flow
pressure loss
flow characteristics of a duct
water mass sources from water vapor condensation
Opis:
The paper presents methodology for determining water mass and pressure drop in ducts with fixed co-current and no-slip two-phase flow. The dispersed liquid phase (water) is present in the air as a result of wet air from underground excavations being distributed in some sections of a discharge pathway, or local water mass sources (or its local outlets) formed by the natural phenomenon of water vapor condensation. For such cases, static pressure losses were determined, which resulted from the force of gravity of the mass of water droplets occurring in the air stream in the duct.
W pracy przedstawiono metodologię wyznaczania masy wody i spadku ciśnienia w przewodach z ustalonym współprądowym bezpoślizgowym przepływem dwufazowym. Zdyspergowana faza ciekła (woda) występuje w powietrzu w wyniku ochłodzenia strumienia wilgotnego powietrza na niektórych odcinkach drogi jego odprowadzenia z wyrobisk podziemnych lub w miejscach występowania lokalnych źródeł masy wody (lub jej lokalnych upustów) utworzonych przez naturalne zjawisko kondensacji pary wodnej przy mieszaniu się strumieni powietrza wilgotnego. Dla takich przypadków określono straty ciśnienia statycznego, które wynikały z siły grawitacji masy kropelek wody występujących w strumieniu powietrza w szybie wydechowym.
Źródło:
Inżynieria Mineralna; 2019, 21, 1/2; 189-197
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transepidermal water loss and skin hydration in healthy cats and cats with non-flea non-food hypersensitivity dermatitis (NFNFHD)
Autorzy:
Szczepanik, M.P.
Wilkołek, P.M.
Adamek, Ł.R.
Kalisz, G.
Gołyński, M.
Sitkowski, W.
Taszkun, I.
Powiązania:
https://bibliotekanauki.pl/articles/2087561.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cats
atopic dermatitis
transepidermal water loss
skin hydration
Źródło:
Polish Journal of Veterinary Sciences; 2019, 2; 237-242
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy of water meters during their operation
Autorzy:
Cichoń, T.
Królikowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/95902.pdf
Data publikacji:
2018
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
water loss
water meter
faulty water meter
strata wody
wodomierz
wadliwy wodomierz
Opis:
The article describes the study on water meters after their five-year period of operation. Water meters were tested at a certification stand to check for possible reading errors. The following devices have been included in the study: water meters with a diameter of 20 mm (single-jet, multi-jet and volumetric) as well as single-jet and screw water meters with a diameter of 50 mm. The faulty water meters were disassembled to identify causes of damage specific for various types of water meters. The percentage of faulty water meters differed among individual types of water meters, as well as among single-jet water meters of different manufacturers. The tests carried out should verify the actual errors of water meter readings during and after operation, and check whether the errors vary for different types of water meters. After many years of operational experience, it may be concluded that water meters, if lose their correct metrological properties, they usually show a smaller values than the actual flow. In such cases, faulty water meters cause the apparent water loss. Based on the study the authors found that volumetric water meters had the highest reliability among household water meters while screw water meters among industrial water meters. The studies have confirmed that damaged water meters can contribute to higher apparent water losses.
Źródło:
Ekonomia i Środowisko; 2018, 2; 63-75
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and Modelling on Radiated Noise of a Typical Fishing Boat Measured in Shallow Water Inspired by AQUO Project’s Model
Autorzy:
Peng, Z.
Fan, J.
Wang, B.
Powiązania:
https://bibliotekanauki.pl/articles/177092.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
radiated noise
South China Sea
predicted model
shallow water
transmission loss
Opis:
The shipping noise near channels and ports is an important contribution to the ambient noise level, and the depth of these sites is often less than 100 m. However less attention has been paid to the measurement in shallow water environments (Brooker, Humphrey, 2016). This paper presents extensive measurements made on the URN (underwater radiated noise) of a small fishing boat in the South China Sea with 87 m depth. The URN data showed that the noise below 30 Hz was dominated by the background noise. The transmission loss (TL) was modelled with FEM (finite element method) and ray tracing according to the realistic environmental parameters in situ. The discrepancy between the modelled results and the results using simple law demonstrates both sea surface and bottom have significant effect on TL for the shallow water, especially at low frequencies. Inspired by the modelling methodology in AQUO (Achieve QUieter Oceans) project (Audoly et al., 2015), a predicted model applied to a typical fishing boat was built, which showed that the URN at frequencies below and above 100 Hz was dominated by non-cavitation propeller noise and mechanical noise, respectively. The agreement between predicted results and measured results also demonstrates that this modelling methodology is effective to some extent.
Źródło:
Archives of Acoustics; 2018, 43, 2; 263-273
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of water losses and failure frequency in an urban-rural water supply system
Autorzy:
Gwoździej-Mazur, J.
Świętochowski, K.
Kaźmierczak, B.
Powiązania:
https://bibliotekanauki.pl/articles/96709.pdf
Data publikacji:
2018
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
system zaopatrzenia w wodę
strata wody
water supply system
water loss
Opis:
This article presents the results of analysis of an urban-rural water supply system. The level of water losses and failure frequency of the water supply system were evaluated. Tests and analyses of the level of water losses were conducted for the years 2010-2016. Tests and analyses of failure frequency were conducted for the years 2013-2016. The guidelines of the International Water Association were applied in calculations. Analyses showed an influence of season on the failure frequency of the urban-rural water supply system. An influence of the number of failures on the volume of water lost in a single failure was also observed. Obtained results were compared with data from domestic literature and the guidelines of standard PN-EN 60300-3-4:2008.
Źródło:
Ekonomia i Środowisko; 2018, 2; 76-86
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies