Tytuł:
Non-destructive testing and analysis of a XIX-century brick masonry building
Autorzy:
Hoła, A.
Sadowski, Ł.
Szymanowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1849725.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mur ceglany
budynek murowany
XIX w.
pęknięcie ściany
ugięcie sufitu
wilgoć nadmierna
badanie nieniszczące
brick masonry
masonry building
19th century
wall crack
ceiling deflection
excessive dampness
nondestructive testing
Opis:
The article presents the results of non-destructive testing and analyses carried out for a brick masonry building from the 19th century, which has many irregularities that involve a lack of inspections and tests of its technical condition for many years, as well as a failure to carry out necessary repairs. The conducted organoleptic tests enabled the most significant building damage to be indicated, and its causes were determined on the basis of the results of non-destructive tests and analyses. These causes include mainly wall cracks, ceiling deflections and excessive dampness. It also contains the relationships, which were developed using non-destructive dielectric and resistive methods when testing the moisture content of the brick walls. These results may be useful for other researchers dealing with brick masonry buildings from a similar period of time. The authors' intention was to present the existing poor technical condition of the brick masonry building and indicate its causes, as well as to present that a lack of appropriate maintenance can lead to a situation in which the life or health of residents is threatened.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 201-219
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of CNTs and SiO2 for thermostability and mechanical properties of PF microcapsules : used for self-healing of closed wall cracks in goaf
Autorzy:
Fu, Mingming
Ma, Boyu
Zhang, Yuanping
Jia, Xinlei
Chen, Lu
Zhang, Yuping
Sun, Kaidi
Zhao, Guanning
Wang, Mengyao
Powiązania:
https://bibliotekanauki.pl/articles/24085883.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
PF microcapsule
crack repair
closed wall
nanomaterials
heat resistance
brittleness
Opis:
Air leakage of closed wall in coal mine goaf would cause spontaneous combustion of remained coal. Most of measures to repair cracks are carried out after cracks are penetrated, which is not conducive to early prevention of spontaneous combustion. Repairing damage at the initial stage of cracking makes prevention effect to the best. Phenol-formaldehyde resin (PF) microcapsules embedded in closed wall to achieve self-healing of initial cracks, but the actual repair effect is often less than expected. PF microcapsules (PFM) of carbon nanotubes (CNTs) and silicon dioxide (SiO2) decorated shell for self-healing of closed wall cracks were prepared by in-situ polymerization. The effects of nanomaterials on morphology, chemical constitution, thermal performance and mechanical properties of PF microcapsules were characterized by scanning electron microscopy (SEM), fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA) and nanoindentation test. The test results indicated that nanomaterials were successfully introduced into the shell of PF microcapsules. The CNTs-SiO2@PF microcapsules were uniformly dispersed, the thermal decomposition was delayed, and the residual carbon was significantly increased, and the brittleness of PF microcapsules was significantly enhanced. The 0.2CNTs-SiO2@PF microcapsules (0.2CNTs-SiO2@PFM) had a uniform and full particle size, the initial decomposition temperature was 267.6℃, the residual mass was 41.3%, the maximum load on the capsule wall reached 94.79 mN, and the load dropped sharply after the capsule wall rupture. Finally, the self-healing mechanism of closed wall doped with microcapsules was discussed. The exploration of modified phenolic microcapsules provides a new idea for the repair of closed wall in goaf.
Źródło:
Physicochemical Problems of Mineral Processing; 2023, 59, 3; art. no. 170020
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pęknięcie ściany w modernistycznym kościele pod wezwaniem Najświętszego Zbawiciela w Zielonej Górze – przyczyna
Crack of the wall in the modernist church of the Holly Savior (Najświętszego Zbawiciela) in Zielona Góra – possible cause
Autorzy:
Michalak, B.
Powiązania:
https://bibliotekanauki.pl/articles/105300.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
zabytek architektury
modernizm
pęknięcie
ściana
osiadanie
słup betonowy
monument of architecture
modernism
wall
crack
subsidence
Opis:
Zielona Góra nie jest miastem bogatym w zabytki architektury z okresu modernizmu. Budowle z tej epoki są jednak coraz powszechniej uznawane za cenne z najbardziej interesujących jest pochodzący z roku 1917 kościół pw. Najświętszego Zbawiciela przy ul. Niepodległości. Świątynia ufundowana przez fundację imienia znanego zielonogórskiego przemysłowca Georga Beuchelta do dziś jest jednym z najbardziej rozpoznawalnych kościołów w mieście. Projekt Wilhelma Wagnera i Oscara Hossfelda został zrealizowany przy współudziale przedsiębiorstwa Fabrik für Brückenbau und Eisenkonstruktionen Beuchelt & Co. Grünberg in Schlesien. Konstrukcje stalowe zrealizowane przez tę firmę istnieją do dziś nie tylko w Europie, ale także na terenie Afryki i Azji. W 2015 roku, niemalże w setną rocznicę budowy obiektu, zauważono pęknięcie na jednej ze ścian wewnątrz korpusu świątyni. W niniejszym artykule podjęto próbę znalezienia przyczyny wspomnianego uszkodzenia. Obecnie nie obserwuje się zwiększania wielkości pęknięcia, ani nowych śladów uszkodzeń. Nie można jednak pozwolić sobie na bagatelizowanie zjawiska. Nie zbadanie przyczyn i brak metod zapobiegania dalszym uszkodzeniom może doprowadzić do pogorszenia stanu technicznego budowli. Budynek ten jest cennym obiektem sztuki inżynierskiej zarówno w skali miasta jak i regionu. Utrzymanie go w dobrym stanie technicznym powinno być ważnym tematem zarówno dla administracji kościelnej jak i służb konserwatorskich.
There are not too many architectural monuments from the period of modernism in the city of Zielona Góra. Buildings from this era, however, are increasingly recognized as valuable from the point of view of the monuments of engineering and protection. One of the most interesting is the church of the Holy Savior (Najświęsztego Zbawiciela) built in 1917 at the Niepodległości Street. Temple was founded by the foundation named by the known industrialist from Zielona Góra - George Beuchelt and today it is one of the most recognizable churches in the city. Project of Wilhelm Wagner and Oscar Hossfeld was realized in cooperation with the company Fabrik für Brückenbau und Eisenkonstruktionen Beuchelt & Co. Grünberg in Schlesien. Steel constructions which have been built by this company exist up till now not only in Europe, but also in Africa and Asia. In 2015, almost hundred years finishing the construction a crack on one of the walls inside the body of the temple has been observed. In the paper the cause of that damage is analyzed. Currently no increase of the cracks and no outgoing signs of damage is observed. But we cannot afford to underestimate of the phenomenon. The lack of examining the reasons and the preventing further damage can lead to a deterioration of the technical condition of the building. The church is the valuable piece of art engineering both in the city and the region. Keeping it in good condition should be an important topic for both the church administration and conservation services.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 1; 219-228
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uszkodzenie i wzmocnienie prefabrykowanych przestawnych ścian oporowych w magazynie materiałów sypkich
Damage and reinforcement of prefabricated adjustable retaining walls in a bulk material warehouse
Autorzy:
Kamiński, Mieczysław
Drzazga, Michał
Kaźmierowski, Maciej
Drzazga, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2202735.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
ściana oporowa
ściana prefabrykowana
ściana żelbetowa
uszkodzenie
pęknięcie
wzmocnienie
analiza obliczeniowa
MES
metoda elementów skończonych
retaining wall
precast wall
reinforced concrete wall
damage
crack
reinforcement
calculation analysis
FEM
finite element method
Opis:
W artykule opisano studium przypadku uszkodzenia prefabrykowanej, przestawnej ściany oporowej o konstrukcji żelbetowej (dolny fragment) i stalowej (górny fragment). Omówiono przyczyny oraz zakres uszkodzeń. Przeprowadzono analizy numeryczne metodą elementów skończonych (MES) w zakresie wybranych elementów konstrukcyjnych ściany w stanie istniejącym oraz po wykonaniu wzmocnienia. Przedstawiono najważniejsze elementy projektu wzmocnienia wykonanego w programie opartym o technologię BIM.
This paper describes a case study of damage to a precast, repositionable retaining wall made of reinforced concrete (lower section) and steel (upper section). The causes and extent of damage are discussed. Numerical analyses using the finite element method (FEM) of selected structural elements in the existing state and after strengthening were carried out. The most important elements of the wall strengthening project made in a BIM-based software are presented.
Źródło:
Przegląd Budowlany; 2022, 93, 9-10; 20--23
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakter i przyczyny powstawania wczesnych rys termiczno-skurczowych w konstrukcjach betonowych
The nature and causes of early thermal and shrinkage cracks in concrete structures
Autorzy:
Klemczak, B.
Knoppik-Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/162434.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja betonowa
rysa termiczno-skurczowa
konstrukcja masywna
płyta fundamentowa
ściana betonowa
analiza numeryczna
concrete structure
thermal and shrinkage crack
massive construction
foundation slab
concrete wall
numerical analysis
Opis:
Zagadnienia przedstawione w artykule dotyczą często obserwowanych w praktyce zarysowań i spękań konstrukcji betonowych, powstających już w fazie ich wznoszenia. Przyczyną tych zarysowań są przede wszystkim nierównomierne zmiany objętościowe twardniejącego betonu. Spowodowane są one wzrostem temperatury betonu wywołanym egzotermicznym procesem hydratacji cementu oraz wymianą wilgoci twardniejącego betonu z otoczeniem. W artykule opisano charakter oraz przyczyny występowania wczesnych rys i spękań w masywnych płytach fundamentowych oraz w ścianach żelbetowych. Przedstawiono również główne czynniki technologiczno-materiałowe wpływające na zwiększenie ryzyka zarysowania we wczesnym okresie dojrzewania betonu.
The issues discussed in this article relate to a phenomenon frequently observed in practice – fractures and cracks in concrete structures occurring even at the construction stage. The principal reason for these cracks is uneven changes in volume in the hardening concrete. They are caused by an increase in the temperature of the concrete, resulting from an exothermic process of cement hydration and the exchange of moisture in the hardening concrete with the surroundings. The article describes the nature of and reasons for early fractures and cracks in large foundation slabs and in reinforced-concrete walls. It also presents the main technological and material-related factors affecting the risk of cracks appearing at an early stage in concrete curing.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 2, 2; 28-36
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies