Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "voltage-current" wg kryterium: Temat


Tytuł:
Investigation of the Efficiency of the Ozonator in the Process of Water Purification Based on the Corona Discharge
Autorzy:
Abdykadyrov, Askar
Marxuly, Sunggat
Mamadiyarov, Maxat
Smailov, Nunzhigit
Zhunusov, Kanat
Kuttybaeva, Ainur
Amanzholov, Arnay
Orazbekov, Asset
Powiązania:
https://bibliotekanauki.pl/articles/2202354.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
corona discharge
ozonator
sewage
electric current
high voltage
ozonometer
ozone concentration
Opis:
In this research paper, the problem of studying the effectiveness of ozone in the process of water treatment was considered. In the course of the scientific work, a review of domestic and foreign literature was conducted; its advantages and disadvantages were considered. The research paper presented the theoretical and practical methods of water purification with ozone. The main factors influencing the efficiency of the technology in the process of water purification were also considered. It was established that as a technological method of water purification, the efficiency of the ozonation process includes not only the cost of electricity, but also the efficiency of its mixing, ozone dissolution in treated water. In addition, special attention is paid to the final stage of mixing the ozone-air mixture with treated water. From the results obtained, it can be seen that after primary ozonation, the concentrations of chromium, oxidation of permanganate, iron, petroleum products, metal ions and other pollutants significantly decreased. During further water purification, organic and inorganic pollutants are removed in the future (completely or up to the requirements of the standard). However, calcium, magnesium, sulfates, chlorides, pH value, alkalinity and hardness practically do not change. The water quality after primary ozonation according to bacteriological indicators met the requirements of the standard.
Źródło:
Journal of Ecological Engineering; 2023, 24, 2; 140--151
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aplikacyjne programy komputerowe do projektowania przekładników
Computer software application for designing instrument transformers
Autorzy:
Adamczewska, D.
Borowska-Banaś, I.
Jałmużny, W.
Powiązania:
https://bibliotekanauki.pl/articles/155285.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przekładniki prądowe
przekładniki napięciowe
charakterystyka magnesowania
charakterystyka stratności
rdzenie składane osiowo
rdzenie składane promieniowo
current transformers
voltage transformers
magnetization curve
specific losses curve
axial composed cores
radial composed cores
Opis:
W artykule przedstawiono autorskie programy komputerowe do obliczeń projektowych przekładników prądowych i napięciowych.
The author’s computer programs for designing current and voltage transformers there are presented in the paper.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 733-735
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance evaluation of ZVS/ZCS high efficiency AC/DC converter for high power applications
Autorzy:
Ali, A.
Chuanwen, J.
Khan, M. M.
Habib, S.
Ali, Y.
Powiązania:
https://bibliotekanauki.pl/articles/200472.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
switching losses
zero current switching
zero voltage switching
power quality
reverse recovery loss
Opis:
The increased power density, reduced switching losses with minimum electromagnetic interference (EMI), and high efficiency are essential requirements of power converters. To achieve these characteristics, soft power converters employing soft switching techniques are indispensable. In this paper, a ZCS/ZVS PWM AC/DC converter topology has been emphasized, which finds applications in high power systems such as automobile battery charging and renewable energy systems. This converter scheme maintains zero current and zero voltage switching conditions at turn on and turn off moments of semiconductor switches, respectively and soft operation of rectifier diodes that lead to negligible switching and diode reverse recovery losses. Moreover, it improves power quality and presents high input power factor, low total harmonic distortion of the input current (THDI ) and improved efficiency. The validity of theoretical analysis of the proposed converter has been carried out experimentally on a 10 kW laboratory prototype. Experimental results prove that the soft switching operation of the semiconductor switches and diodes is maintained at 98.6% rated load efficiency. In addition, the performance evaluation has been performed by comparative analysis of the proposed converter with some prior art high power AC/DC converters. Efficiencies of the proposed and prior art high power topologies have been determined for different load conditions. The highest efficiency, power factor and lower THDI of the proposed converter topology complies with international standards.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 793-807
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of multi-criteria decision making methods for the assessment of optimal SVC location
Autorzy:
Aydin, Faruk
Gümüş, Bilal
Powiązania:
https://bibliotekanauki.pl/articles/2173650.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Borda count method
FACTS
MCDM
optimal location
PSAT
voltage stability
flexible alternating current transmission system
power system analysis toolbox
multi criteria decision making
metoda liczenia Bordy
podejmowanie decyzji wielokryterialnej
lokalizacja optymalna
stabilność napięcia
elastyczne systemy przesyłowe prądu przemiennego
narzędzia do analizy systemu zasilania
Opis:
The goal of multi-criteria decision making (MCDM) is to select the most appropriate of the alternatives by evaluating many conflicting criteria together. MCDM methods are widely available in the literature and have been used in various energy problems. The key problems studied in electrical power systems in recent years have included voltage instability and voltage collapse. Different flexible alternating current transmission systems (FACTS) equipment has been used for this purpose for decades, increasing voltage stability while enhancing system efficiency, reliability and quality of supply, and offering environmental benefits. Finding the best locations for these devices in terms of voltage stability in actual electrical networks poses a serious problem. Many criteria should be considered when determining the most suitable location for the controller. The aim of this paper is to provide a comparative analysis of MCDM techniques to be used for optimal location of a static VAR compensator (SVC) device in terms of voltage stability. The ideal location can be determined by means of sorting according to priority criteria. The proposed approach was carried out using the Power System Analysis Toolbox (PSAT) in MATLAB in the IEEE 14-bus test system. Using ten different MCDM methods, the most appropriate locations were compared among themselves and a single ranking list was obtained, integrated with the Borda count method, which is a data fusion technique. The application results showed that the methods used are consistent among themselves. It was revealed that the integrated model was an appropriate method that could be used for optimal location selection, providing reliable and satisfactory results to power system planners.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 2; art. no. e140555
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ modyfikacji warystorów do ograniczników przepięć typu SPD na rozkład konduktywności i na charakterystyki przewodzenia
Influence of modification of varistors for the SPD type arresters on the conductivity distribution and conductance characteristics
Autorzy:
Bandel, J.
Mielcarek, W.
Sibilski, H.
Powiązania:
https://bibliotekanauki.pl/articles/159339.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
ograniczniki przepięć
warystory
konduktywność
charakterystyka prądowo napięciowa
arresters
varistors
conductivity
current-voltage characteristics
Opis:
Zapotrzebowanie na warystory do ograniczników przepięć jest bardzo duże, zarówno do ograniczników typu SPD jak i stosowanych na wyższe napięcia znamionowe. Głównym celem jest opracowanie nowej generacji nanostruktur, która zapewni jednorodny rozkład konduktywności na całej płaszczyźnie warystora. To umożliwi zmniejszenie wymiarów warystorów, przy równoczesnej poprawie jakości użytego materiału. Równocześnie możliwe będzie modelowanie charakterystyk prądowo-napięciowych przy większej gęstości prądu przewodzenia.
The required demand of varistors for the arresters, not only for the SPD type, but also for these used at high voltage systems, is very high. The idea of this paper was to develop a new generation of nanostructures of the material which assure a uniform distribution of the conductivity. These enable to reduce the size of the voltage limiting elements and therefore quantity of material used. Also it will be possible to modulate current voltage characteristic with simultaneous great density of current.
Źródło:
Prace Instytutu Elektrotechniki; 2015, 270; 153-167
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Predictive regulation of the output voltage of a three-phase two-level voltage inverter with an LC filter
Autorzy:
Behrendt, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/135032.pdf
Data publikacji:
2019
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
uninterruptible power supply (UPS)
model predictive control (MPC)
predictive voltage regulator
load current prediction in the time domain
load current prediction in the frequency domain
total harmonic distortion (THD)
Opis:
The article has presented a predictive output voltage regulator of a three-phase two-level voltage inverter with an LC filter with a prediction of the receiver current in the time domain and the frequency domain. Simulations of the operation of the regulator were conducted for a three-phase receiver. The circuit model and simulations of the operation of the predictive voltage regulator were performed in the PSIM program. The algorithm of the predictive regulator was written in the C programming language in the Microsoft Visual Studio compiler and attached to the model performed in the PSIM program by a block that supports the Dynamic-Link Library.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2019, 57 (129); 79-87
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities for determining the interference between a power supply network and a converter fed drive
Autorzy:
Beniak, R.
Gardecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1193393.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
power quality
converter drives
voltage and current measurements
Opis:
Measuring instruments, measurement methods, and an exemplary analysis of the impact of chosen operating stages of the converter drive on the power supply network have been presented. The measurements of electrical and mechanical parameters in drive systems used in industry are complex. The task is difficult due to the necessity of connecting a measuring instrument into electric circuits of an active facility with the use of only short non-operational periods of the device. However, a wellchosen model of a drive system allows the multivariate research of the impact of drive parameters and a control algorithm used on voltage and current harmonic content and performance of the system, and therefore on a simulation analysis of the impact of the drive on the power supply network.
Źródło:
Power Electronics and Drives; 2017, 2, 37/1; 17-26
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of asymmetrical currents waveforms to detect and localize open switch faults for two level voltage source inverter three-phase shunt active power filter
Autorzy:
Benslimane, T.
Chetate, B.
Abdelkrim, T.
Powiązania:
https://bibliotekanauki.pl/articles/229453.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
fault detection
two level there phase voltage source inverter
current mean value
Opis:
This paper proposes an open switch faults detection and localization algorithm for shunt three phase active filter topology. It mainly details converter configuration and examines a simple and reliable optimized fault diagnosis method. The converter topology is based on classical three-leg active power filter topology. New fault diagnosis method is proposed, based on classical currents measurements. It includes combinatory logic to analyze and validate error signals. Hysteresis control is applied before and after fault detection, which avoids any controller reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the effectiveness of this method.
Źródło:
Archives of Control Sciences; 2011, 21, 1; 105-117
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernization of the VSVEM-1140 electro-mechatronic system for testing theasynchronous motors
Autorzy:
Beshta, Oleksandr, senior
Khudolii, Serhii
Djur, Roman
Peltek, Illia
Powiązania:
https://bibliotekanauki.pl/articles/27324352.pdf
Data publikacji:
2023
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
testing and charging stations
high-voltage alternating current electric machines
energy recovery in braking modes
electro-mechatronic system
thermal diagnostics of electric machines
system elektromechaniczny
maszyny elektryczne
diagnostyka
Opis:
The article is devoted to the description of practical experience in testing the alternating current electric machines. The results of combining thecapabilities of digital systems for collecting and processing information with a powerful electromechanical system are presented. Itis the combination of two systems of different purposes that enables creating the state-of-the art diagnostic installations combined into one electro-mechatronic system. Practical results of electric machine tests contain clear explanations of fundamental principles and provide acomprehensive assessment of the conditionof electric machines. They use methods of direct charging the electric machines with the possibility of recuperation of electric energy during tests. Thermal state of electrical machine nodes is monitoredusing the thermal forecasting technologies. Both the methods for various types of tests and means for their implementation are described in detail. This article is intended for engineers involved in designing, manufacturing and testing the electric machines.
Źródło:
Mining Machines; 2023, 41, 4; 240--247
2719-3306
Pojawia się w:
Mining Machines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grid-Tied Neutral Point Clamped based Centralised Photovoltaic Inverter with Improved DC Link Voltage Balancing and Harmonic Minimisation Control
Autorzy:
Bhowmick, Supratik
Mukherjee, Debranjan
Maiti, Suman
Chakraborty, Chandan
Powiązania:
https://bibliotekanauki.pl/articles/1955983.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
photovoltaic multilevel inverter
neutral point voltage balancing
space vector pulse width modulation
current harmonic minimisation
Opis:
This paper proposes an improved space vector pulse width modulation (SVPWM) based DC link voltage balancing control of a three-phase three-level neutral point clamped (NPC) centralised inverter supplying the generated power from photo voltaic (PV) array to a three-phase utility grid. Two possible schemes have been developed based on the power conversion stage between PV array and the utility grid namely, two-stage (three-level boost converter three-phase three-level NPC inverter) and single-stage (three-phase three-level NPC inverter alone). The comparison between these two schemes has been thoroughly discussed in terms of the control strategies employed, power loss analysis and efficiency. The performance of the centralised inverter under different modes of operation has been investigated by developing the required control strategies for smooth operation. Using the proposed control strategy, the centralised inverter can be operated as a static synchronous compensator (STATCOM) during night time, if needed. The power loss incurred in the power-electronic converters has been analysed for constant and also for variable ambient temperature. The effectiveness of the centralised inverter as an active filter (AF) has also been verified when a three-phase non-linear load is considered in the system.
Źródło:
Power Electronics and Drives; 2021, 6, 41; 185-203
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ograniczający łącznik napięcia przemiennego
Current limiting switch of alternative voltage
Autorzy:
Bogusławski, P.
Powiązania:
https://bibliotekanauki.pl/articles/408284.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
ogranicznik prądu zwarciowego
łącznik tyrystorowy
napięcie przewodzenia
przekształtnik DC/DC
short circuit current limiter
thyristor switch
forward on-state voltage
DC/DC inverter
Opis:
Na podstawie znanej koncepcji tyrystorowego ogranicznika prądu zwarciowego przedstawiono modyfikację tego układu do zastosowania także jako łącznik niewielkich prądów roboczych. Zaproponowano przekształtniki DC/DC sterujące działaniem łącznika i pośrednio zmniejszające wpływ temperatury oraz przedstawiono orientacyjnie symulowane przebiegi w obwodzie z łącznikiem jednofazowym. W podsumowaniu wskazano pokrótce na konsekwencje jego zastosowania.
Based on literature study of known thyristor limiters and the modification providing of a low current switch function was presented. The proposed DC/DC inverters for control and temperature indirect independency was described. Preliminary results of one phase switch circuit simulation are included. In summary succession problems of application was shortly pointed out.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2014, 2; 37-40
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of influence of the type line supplying nonlinear load on deformation of voltage and current in the power system
Autorzy:
Bolkowski, S.
Brociek, W.
Wilanowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/97618.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
deformations of voltage and current
frequency characteristics
passive filters
overhead and cable lines
Opis:
The results of simulation tests concerning the cooperation of the nonlinear load with the power system are presented. In numerical experiments we have taken data from the real systems, including the cable and overhead lines. In practice the nonlinear load of high power may be supplied by the overhead or cable lines. The paper presents the comparative analysis, how the applied type of the line influences the level of distortion of the voltages and currents in the power system. The values of the higher harmonics of the voltages and currents as well as THD have been determined in the paper. These values have been estimated for the beginning and ending terminals of the overhead and cable lines supplying the nonlinear load of the inductive character concerning the cooperation of the filtering compensating device and the nonlinear load of high power. All experiments have been performed using MicroCap-8 program. In the paper we have included he exemplary results of the numerical calculations.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 11-23
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy kačestva èlektrosnabženiâ promyšlennyh potrebitelej ot obmotki srednego naprâženiâ tâgovyh podstancij peremennogo toka
Problemy jakości zasilania konsumentów przemysłowych z uzwojenia średniego napięcia podstacji trakcyjnych prądu przemiennego
The Problems of Power Quality for Industrial Consumers Fed on the Medium-voltage Winding from AC Traction
Autorzy:
Bosyj, D. A.
Powiązania:
https://bibliotekanauki.pl/articles/215440.pdf
Data publikacji:
2014
Wydawca:
Instytut Kolejnictwa
Tematy:
podstacja trakcyjna
prąd zmienny
napięcie
asymetria
moc bierna
kompensacja
traction substation
alternating current
voltage
unbalance
reactive power
compensation
Opis:
W pracy podstacji trakcyjnych prądu zmiennego może występować znaczące pogorszenie jakości energii elektrycznej. Z powodu obniżenia jakości energii elektrycznej, straty ponoszą przede wszystkim odbiorcy przemysłowi zasilani z uzwojenia średniego napięcia transformatora trakcyjnego. Wyniki przeprowadzonych badań potwierdzają teoretycznie znane problemy z jakością napięcia, a mianowicie zawyżenie napięcia w jednej z faz, róż-nicę napięć na sąsiednich podstacjach, odchylenie trójfazowego układu wektorów napięcia. Analiza znanych metod symetryzacji opartych na zjawisku Scotta wykazała, że założenie o równości kątów obciążenia w odcinkach zasilania, powoduje znaczący błąd w określeniu zjawiska symetryzującego, które nie jest wystarczające do spełnienia wymagań normy w zakresie asymetrii napięć. Zaproponowano rozwiązanie techniczne, które polega na udoskonaleniu urządzeń do ciągłej kompensacji mocy biernej i zapewnia normowaną wartość wskaźnika asymetrii napięcia przy jednoczesnym zmniejszeniu przepływów mocy biernej.
Working of AC traction substations involves significant distortion of the quality of electric energy. First of all, suffer from poor quality of electric power, industrial consumers, which feed on the medium-voltage winding of the traction transformer. Conducted measurements confirm the theory known problems with the quality of voltage that is overstating the voltage in one phase, the difference between the substations, wry three-phase system voltage vectors. Analysis of the known methods of balancing based on the Scott effect showed that the assumption of the equality of the angles at the shoulders load power is making a significant error in the determination of the symmetry effect, which is not enough to ensure the standard requirements regarding voltage unbalance. The proposed solution, which is to improve the devices continuously reactive power compensation and allows normal coefficient of voltage unbalance simultaneously with a reduction in reactive power flows.
Źródło:
Problemy Kolejnictwa; 2014, 162; 21-32
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single-pulse method for measuring the current-voltage characteristics of solar panels
Autorzy:
Bozhko, K. M.
Zashchepkina, N. M.
Markin, M. O.
Markina, O. M.
Powiązania:
https://bibliotekanauki.pl/articles/378907.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
solar batteries
voltage-current characteristic
bateria słoneczna
charakterystyka napięciowo-prądowa
Opis:
Purpose: The purpose of the paper is to substantiate the new method of measuring the voltage-current characteristics of solar batteries based on the use of a digital oscilloscope and a special linear sweep device. Design/methodology/approach: To solve this problem, a test bench was developed on the basis of a solar radiation simulator. Findings: Practically it is proved that within the duration of a single pulse of 40 μs, it is possible to measure the voltage-current characteristics of an SB with a short-circuit current of up to 5.8 A. Research limitations/implications: The method is relevant for all types of solar batteries, but the measurements were carried out on serial samples of mono and polycrystalline silicon with a nominal output power of 30 to 140 W and a voltage of 12 V. Practical implications: The method can find its practical application in the development of an intelligent solar module. The technology of the intelligent module is based on the periodic removal of information on the operational parameters of the solar battery based on the measured voltage-current characteristic. Originality/value: Experimental confirmation of the effectiveness of the single-pulse measurement method of the voltage-current characteristic of a solar battery based on a linear current sweep.
Źródło:
Archives of Materials Science and Engineering; 2019, 99, 1/2; 24-29
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental Pollution Monitoring on High-Voltage Insulators
Monitorowanie zanieczyszczenia środowiska na izolatorach wysokiego napięcia
Autorzy:
Briancin, J.
Dolnik, B.
Fabian, M.
Kolcunova, I.
Kurimsky, J.
Dzmura, J.
Cimbala, R.
Powiązania:
https://bibliotekanauki.pl/articles/319135.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
izolatory wysokonapięciowe
zanieczyszczenie środowiska
prąd upływowy
przewodnictwo elektryczne
monitorowanie in-situ
high-voltage insulators
environmental pollution
leakage current
electrical conductivity
in-situ monitoring
Opis:
This work is focused on environmental pollution monitoring on selected high-voltage insulators. It is well known that environmental pollution on electrical insulation is one of the problems faced by distribution utilities and electricity transmission system. Due to this reason there is a need to deal with monitoring of environmental pollution as it strongly influences their capability to withstand the high-voltage stress without the breakdown. It is the aim of present work to explain influence of morphology and chemical composition of pollutants on the surface resistance and conductivity of selected insulators.
W artykule przedstawiono wyniki prac dotyczących monitorowania zanieczyszczenia środowiska na wybranych izolatorach wysokonapięciowych. Powszechnie wiadomo, że zanieczyszczenie środowiska oddziałujące na izolację elektryczną jest jednym z problemów, z którymi borykają się przedsiębiorstwa dystrybucyjne i system przesyłu energii elektrycznej. Z tego powodu istnieje potrzeba monitorowania zanieczyszczenia środowiska które silnie wpływa na ich zdolność instalacji do pracy bez awarii. Celem niniejszego artykułu jest wyjaśnienie wpływu morfologii i składu chemicznego zanieczyszczeń na oporność powierzchni i przewodnictwo wybranych izolatorów.
Źródło:
Inżynieria Mineralna; 2018, R. 19, nr 1, 1; 111-114
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies