Tytuł:
Simulation study on the structural optimization of composite insulators based on contaminant deposition
Autorzy:
Lv, Yukun
Chen, Zeze
Wang, Qian
Lu, Yao
Li, Xiaojing
Powiązania:
https://bibliotekanauki.pl/articles/27309958.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
composite insulator
contaminant deposition characteristics
numerical simulation
voltage type
structural optimization
Opis:
Optimizing the aerodynamic structure of composite insulators can guarantee the safe operation of power systems. In this study, we construct a simulation model for composite insulator contaminant deposition using the COMSOL simulation software, and the rationality of the simulation model and method is verified through wind tunnel experiments. Taking the FXBW4-110/100 composite insulator as an example, we adopt a progressive optimization plan to explore the impacts of shed spacing s, and shed inclination angles α and β on its contaminant deposition characteristics under DC and AC voltages. Based on the numerical simulation results, we analyze the antifouling performance of insulators before and after structural optimization. The results indicate the following: 1) The contaminant deposition of the insulator under AC and DC voltages is negatively correlated with the shed spacing s, but positively correlated with the lower inclination angle β. 2) Under AC voltages, the contaminant deposition of the insulator increases with the upper inclination angle α, while under DC voltages, the contaminant deposition shows an uptrend first, then a downtrend and then an uptrend again with the increase of the upper inclination angle α. 3) Compared with the original model, the AC-optimized model ( α = 6°, β = 2° and s = 98 mm) with a larger shed spacing s, and smaller shed inclination angles α and β showed superior antifouling performance at wind speeds of no less than 2 m/s, and under the typical conditions ( v = 2.5 m/s, d = 20 μm, and ρ = 2 200 kg/m 3), its contaminant deposition is 15% less than that of the original model ( α = 10°, β = 2° and s = 80 mm).
Źródło:
Archives of Electrical Engineering; 2023, 72, 4; 1089--1105
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on the output characteristics of photovoltaic arrays under partial shading conditions based on peak point approximate calculation method
Autorzy:
Wei, Liming
Li, Kaikai
Powiązania:
https://bibliotekanauki.pl/articles/2086691.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
– characteristic equation
peak point approximate calculation method
peak voltage point
shadow occlusion’s rate
type of illumination distribution
Opis:
The mismatch effect of photovoltaic (PV) arrays due to different illumination intensity has a significant impact on the output characteristics and output power of PV arrays, which is crucial to understand the output characteristics of PV arrays and optimize the array configuration in order to improve the value of the maximum power point. This paper illustrates the short-circuit current mismatch of series circuits, and the open-circuit voltage mismatch of parallel circuits and proposes corresponding solutions for each mismatch phenomenon. The output characteristics of multi-stage series PV arrays and multi-stage parallel PV arrays under complex illumination are analyzed by using the peak point approximation calculation method, and the distribution law of peak voltage points as well as the I-V (Current-Voltage) characteristic equation of each operating section are proposed. On this basis, the output characteristics of 3 x 3 centralized PV arrays are analyzed and verified by simulation. By comparing series and parallel PV arrays with the same condition, as well as several groups of centralized PV arrays with the same topology and different types of illumination distribution, this paper proposes a configuration optimization method for PV arrays. Matlab/Simulink simulation results confirm that the output power of parallel arrays is greater than that of series arrays under the same configuration and illuminationt distribution type, and the peak point is less than that of series arrays under the same configuration and lighting conditions; while in centralized PV arrays, the fewer series modules are shaded, the greater the output power and the less the peak point.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 409--424
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault diagnosis of T-type three-level inverter based on bridge voltages
Autorzy:
Chen, Danjiang
Liu, Yutian
Zhang, Shaozhong
Powiązania:
https://bibliotekanauki.pl/articles/1841372.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bridge voltage
fault diagnosis
fault signal
open-circuit fault
T-type three-level inverter
napięcie mostka
błędna diagnoza
sygnał błędu
błąd obwodu otwartego
falownik trójpoziomowy typu T
Opis:
Multilevel inverters have been widely used in various occasions due to their advantages such as low harmonic content of the output waveform. However, because multilevel inverters use a large number of devices, the possibility of circuit failure is also higher than that of traditional inverters. A T-type three-level inverter is taken as the research object, anda diagnostic study is performed on the open-circuit fault of insulated gate bipolar transistor (IGBT) devices in the inverter. Firstly, the change of the current path in the inverter when anopen-circuit fault of the device occurred, and the effect on the circuit switching states andthe bridge voltages were analyzed. Then comprehensively considered the bridge voltages,and proposed a fault diagnosis method for a T-type three-level inverter based on specificfault diagnosis signals. Finally, the simulation verification was performed. The simulation results prove that the proposed method can accurately locate the open-circuit fault of theinverter device, and has the advantage of being easy to implement.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 73-87
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies