Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "voltage source inverter" wg kryterium: Temat


Wyświetlanie 1-11 z 11
Tytuł:
Initial Excitation Issues of Synchronous Generator with VSI Inverter in Varying Rotational Speed Operation
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/2064987.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
synchronous generator
initial excitation
FOC control
voltage source inverter
synchronization
Opis:
Synchronous self-excited generators still are and probably will be the most popular 3-phase alternators installed in inland power stations so onboard of seagoing ships. Because of fuel savings and environmental restrictions Diesel, dual-fuel and gas propulsion engines for alternators of wide-range varying revolutions drives are increasingly used. There must be efficient way of creating 3-phase voltages of desired constant parameters ensured when generator produces variable amplitudes and frequencies of voltages because of changing rotational speed. As the control method modified field oriented control widely used with squirrel cage induction machines was chosen. This control method involves decoupling of currents and control voltages to flux and torque components and keeping them in optimal (orthogonal) condition. In order to obtain proper excitation and operation of such generator several factors have to be taken into account. Nonlinear dependence of voltage generated from rotational speed of self-excited synchronous generator is one of the factors that affects initial excitation process thus specific control method while generator startup. Theoretical background of synchronous generator excitation and voltage source inverter adopted FOC control method along with experimental results obtained in laboratory test bench of 5,5 kW generator and conclusions were presented.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 377--383
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obserwator prędkości silnika asynchronicznego pracującego w układzie z filtrem sinusoidalnym
Speed control of asynchronous motor in system with output LC filter
Autorzy:
Guziński, J.
Powiązania:
https://bibliotekanauki.pl/articles/153952.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
falownik napięcia
filtr sinusoidalny
sterowanie wektorowe
voltage source inverter
LC filter
vector control
Opis:
W układach napędowych z tranzystorowymi falownikami napięcia występują niekorzystne zjawiska wynikające z dużych stromości napięć zasilających silnik. Aby ich uniknąć między falownik a silnik włącza się filtr bierny wygładzający przebiegi napięć i prądów silnika. Włączenie takiego filtru sinusoidalnego powoduje zmianę struktury układu i powoduje konieczność modyfikacji układu sterowania silnika i estymatorów zmiennych stanu układu. W niniejszym referacie przedstawiono układ napędowy w sterowaniu którego uwzględniono filtr sinusoidalny.
In the electric drives with voltage inverters appears disadvantageous phenomena come from high du/dt in motor supply voltage. To prevent that phenomena the passive filter is introduced between motor and inverter. Filter assure smoothed voltages and current in the electric motor. When the filter is used the structure of the system is changed so the control and estimation structure should be changed also. In the paper the modified electric drive with output LC filter is presented.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 27-31
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Speed control of multiphase cage induction motors incorporating supply sequence
Autorzy:
Drozdowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/141418.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multiphase cage induction motor
supply sequence
speed control
multiphase voltage source inverter
field oriented control
Opis:
The subject of this paper is the control possibility of the multiphase cage induction motors having number of phases greater than 3. These motors have additional properties for speed control that distinguish them from the standard 3 phase motors: operation at various sequences of supplying voltages due to the inverter control and possible operation with few open-circuited phases. For each supply sequence different no load speeds at the same frequency can be obtained. This feature extends the motor application for miscellaneous drive demands including vector or scalar control. This depends mainly on the type of the stator winding for a given number of phases, since the principle of motor operation is based on co-operation of higher harmonics of magnetic field. Examples of operation are presented for a 9-phase motor, though general approach has been discussed. This motor was fed by a voltage source inverter at field oriented control with forced currents. The mathematical model of the motor was reduced to the form incorporating all most important physical features and appropriate for the control law formulation. The operation was illustrated for various supply sequences for “healthy” motor and for the motor operating at one phase broken. The obtained results have shown that parasitic influence of harmonic fields interaction has negligible influence on motor operation with respect to the useful coupling for properly designed stator winding.
Źródło:
Archives of Electrical Engineering; 2014, 63, 4; 511-534
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of asymmetrical currents waveforms to detect and localize open switch faults for two level voltage source inverter three-phase shunt active power filter
Autorzy:
Benslimane, T.
Chetate, B.
Abdelkrim, T.
Powiązania:
https://bibliotekanauki.pl/articles/229453.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
fault detection
two level there phase voltage source inverter
current mean value
Opis:
This paper proposes an open switch faults detection and localization algorithm for shunt three phase active filter topology. It mainly details converter configuration and examines a simple and reliable optimized fault diagnosis method. The converter topology is based on classical three-leg active power filter topology. New fault diagnosis method is proposed, based on classical currents measurements. It includes combinatory logic to analyze and validate error signals. Hysteresis control is applied before and after fault detection, which avoids any controller reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the effectiveness of this method.
Źródło:
Archives of Control Sciences; 2011, 21, 1; 105-117
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A state-space approach for control of NPC type 3-level sine wave inverter used in FOC PMSM drive
Autorzy:
Tarczewski, T.
Grzesiak, L. M.
Wawrzak, A.
Karwowski, K.
Erwiński, K.
Powiązania:
https://bibliotekanauki.pl/articles/200731.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
state feedback control
linear quadratic regulator
3-level neutral point clamped voltage source inverter
LC filter
Opis:
This paper presents the design and analysis process of state feedback controllers for NPC type 3-level sine wave inverter. In order to achieve good dynamic features in a state feedback control an internal model of reference input and a feedforward path are introduced. During synthesis process of the state feedback controllers maximum permissible dynamics of voltage control in the linear range of modulation is taken into account. It is shown that initially gains of the controller and feedforward path are non-stationary and depend on the angular velocity. Stationary approximation of a non-stationary state feedback controller is presented in details. Proposed state feedback control structures for continuous voltage shaping NPC type 3-level voltage source inverter are examined in FOC PMSM drive. The novelty of the presented controller lays in a stationary approximated state feedback control structure designed in terms of maximum permissible dynamics of a voltage control system. Simulation and experimental results (at the level of 3 kW) of the designed control algorithms are included.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 3; 439-448
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Augmented speed control scheme of dual induction motors with mutual flux angle control loop
Autorzy:
Kondratenko, Dmytro
Lewicki, Arkadiusz
Łuksza, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/27309952.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
dual-motor drive
induction motors
IMs
five-leg voltage source inverter
FLVSI
rotor angle control
sensorless control
Opis:
This paper proposes an augmented speed control scheme of dual induction motors fed by a five-leg voltage source inverter (VSI) with a common/shared-leg. An additional control loop is proposed here and based on the mutual flux angle – the difference between flux angular positions of the IMs. The main purpose of this research is to minimize the energy losses in the common inverter leg by controlling the mutual flux angle, at equal angular speeds of both motors. Simulation and experimental studies were carried out and the effectiveness of the proposed control method was proven. The PLECS software package was used for the simulation tests. The laboratory prototypewas prepared for the experimental validation. All results were provided and discussed in this paper.
Źródło:
Archives of Electrical Engineering; 2023, 72, 4; 915--930
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of fault states in drive systems with multi-phase induction motors
Autorzy:
Listwan, Jacek Jan
Powiązania:
https://bibliotekanauki.pl/articles/141008.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Direct Field-Oriented Control method
Fault Tolerant Control
MRASCC estimator
multi-phase squirrel-cage induction moto sensorless drives
Voltage Source Inverter faults
Opis:
The paper presents the analysis of different fault states in drive systems with multiphase induction motors. The mathematical models of a five-phase and six-phase induction motor and the MRASCC estimator have been presented and the description of the Space Vector Modulation has been shown. The Direct Field-Oriented Control (DFOC) system is analyzed. Results of the simulation and experimental studies of the Direct Field-Oriented Control systems in the fault conditions are presented. The author’s original contribution includes analysis and studies of the DFOC control method of a five-phase induction motor resistant to the motor speed sensor fault with the use of the MRASCC estimator.
Źródło:
Archives of Electrical Engineering; 2019, 68, 4; 817-830
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór parametrów regulatora prędkości w bezpośrednim sterowaniu momentem silnika indukcyjnego
Speed controller parameters selection in direct torque control (DTC)
Autorzy:
Sieklucki, G.
Orzechowski, T.
Sykulski, R.
Powiązania:
https://bibliotekanauki.pl/articles/320201.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
silnik indukcyjny
falownik napięcia
bezpośrednie sterowanie momentem (DTC)
regulacja prędkości kątowej
induction motor
voltage source inverter
direct torque control (DTC)
angular speed control
Opis:
Przedstawiono standardową strukturą układu bezpośredniego sterowania momentem (DTC) silnikiem indukcyjnym. Zaprezentowano metody doboru parametrów regulatorów prędkości P oraz PI. Omówione metody poparto badaniami symulacyjnymi.
Standard structure of direct torque control (DTC) system of induction motor is presented. Speed controller (type P and PI) parameters selection methods are proposed and simulation result of this control system are discussed
Źródło:
Elektrotechnika i Elektronika; 2005, 24, 1; 84-92
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prosty sposób optymalizacji parametrycznej w metodzie (FOC) dla silnika indukcyjnego
Simple method of parameters optimization in field orientated control (FOC) of induction motor
Autorzy:
Sieklucki, G.
Orzechowski, T.
Sykulski, R.
Powiązania:
https://bibliotekanauki.pl/articles/320192.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
silnik indukcyjny
falownik napięcia
sterowanie polowo zorientowane
FOC
optymalizacja parametryczna
regulacja prędkości kątowej
induction motor
voltage source inverter
field oriented control
angular speed control
parameter optimization
Opis:
W artykule przedstawiono standardową strukturę układu sterowania polowo zorientowanego (FOC) regulacji prędkości silnika indukcyjnego zasilanego z falownika napięcia. Zaprezentowano prostą metodę doboru regulatorów prądów i prędkości (typu PI). Zamieszczono wyniki badań symulacyjnych.
Standard structure of field orientated control (FOC) system of induction motor is presented. Simple method of parameters selection of currents and speed controller (type PI) are proposed. Simulation result of this control system are discussed.
Źródło:
Elektrotechnika i Elektronika; 2005, 24, 1; 93-99
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Repetitive neurocontroller with disturbance feedforward path active in the pass-to-pass direction for a VSI inverter with an output LC filter
Autorzy:
Ufnalski, B.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/200017.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
repetitive control
feedforward neural network
dynamic optimization problem
repetitive disturbance rejection
voltage source inverter
disturbance dual feedforward path
sterowanie powtarzalne
sieci neuronowe
problem optymalizacji dynamicznej
przetwornica napięcia
odrzucanie zakłóceń
Opis:
An enhancement to the previously developed repetitive neurocontroller (RNC) is discussed and investigated in the paper. Originally, the time-base generator (TBG) has been used to produce the only input signal for the neural approximator. The resulting search space makes the dynamic optimization problem (DOP) of shaping the control signal solvable with the help of a function approximator such as the feed-forward neural network (FFNN). The plant under consideration, i.e. a constant-amplitude constant-frequency voltage-source inverter (CACF VSI) with an output LC filter, is assumed to be equipped with the disturbance load current sensor to enable implementation of the disturbance feed-forward (pDFF) path as a part of the non-repetitive subsystem acting in the along the pass p-direction. An investigation has been undertaken to explore potential benefits of using this signal also as an additional input for the RNC to augment the approximation space and potentially enhance the convergence rate of the real-time search process. It is numerically demonstrated in the paper that the disturbance feed-forward path active in the pass-to-pass k-direction (kDFF) improves the dynamics of the repetitive part as well indeed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 1; 115-125
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uncertainty mathematical models of power converters
Niepewność modeli matematycznych układów energoelektronicznych
Autorzy:
Sieklucki, G.
Bisztyga, B.
Powiązania:
https://bibliotekanauki.pl/articles/282164.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
przekształtnik tyrystorowy
falownik napięcia
napęd elektryczny
niepewność multiplikatywna
regulator I I2
element oscylacyjny
sterowanie odporne
thyristor-controlled converter
voltage source inverter
electric drive
multiplicative uncertainty
I I2 controller
oscillatory element
robust control
Opis:
The controller synthesis problem of the motor torque with parameters changes of the power converter is presented. The parameters uncertainty of the power converters described by gain and time-delay are analysed in the article. The principles of determining the range of the parameters variations are presented. The conversion method from the parametric to the dynamic uncertainty which can be useful to a robust controller optimization, is shown. A multiplicative uncertainty weight as the oscillatory element is proposed. The tuning of the I I2 controller parameters of the electromagnetic motor torque is introduced. The results are obtained by applying the mixed sensitivity method (robust performance) which is the optimization in H∞ space.
W artykule przedstawiony został problem syntezy regulatora momentu elektromagnetycznego silnika przy zmianach parametrów układu zasilającego. W artykule analizowana jest niepewność parametrów układów zasilających silniki elektryczne, opisana przez wzmocnienie i opóźnienie czasowe. Podano zasady wyznaczania zakresu zmian tych parametrów. Przedstawiono metodę przekształcenia niepewności parametrycznej na dynamiczną, która może być wykorzystana w optymalizacji regulatora odpornego. Zaproponowano funkcję wagową niepewności multiplikatywnej w postaci elementu oscylacyjnego. Wyznaczono regulator I I2 momentu elektromagnetycznego dla silnika. Wyniki te uzyskano, stosując metodę mieszanej czułości, czyli optymalizację w przestrzeni H∞.
Źródło:
Automatyka / Automatics; 2012, 16, 1; 73-87
1429-3447
2353-0952
Pojawia się w:
Automatyka / Automatics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies