Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "voice assessment" wg kryterium: Temat


Wyświetlanie 1-11 z 11
Tytuł:
Does neuromonitoring affect voice quality in patients subjected to a complete thyroidectomy ?
Autorzy:
Bryk, Piotr
Głuszek, Stanislaw
Powiązania:
https://bibliotekanauki.pl/articles/23203211.pdf
Data publikacji:
2021-05-12
Wydawca:
Index Copernicus International
Tematy:
intraoperative neuromonitoring
recurrent laryngeal nerve
vocal cord
thyroidectomy
voice assessment
voice quality
Opis:
Introduction: Voice dysfunction is the most common complication of thyroid surgery. The use of intraoperative neuromonitoring (IONM) is to protect the recurrent laryngeal nerves, the damage of which causes voice dysfunction. Aim: The aim of the study was to evaluate voice quality in patients who underwent complete thyroidectomy operated on with the application of IONM as well as a group of patients operated on with only macroscopic nerve visualization. In the analysis, clinical voice assessment was performed with particular focus on voice efficiency using the Voice Handicap Index (VHI), Vocal Tract Discomfort (VTD) and GRBAS scale. Material and methods: The study group consisted of 205 patients operated on with IONM. The control group consisted of 162 patients subjected to surgery only with macroscopic visualization of recurrent laryngeal nerves, without IONM. During the follow-up period from 2 to 10 years after surgery, checkups were performed. Each patient who came for a checkup was subjected to perceptual voice evaluation with the use of the GRBAS scale, indirect laryngoscopy procedure and voice selfevaluation with two questionnaires (VHI and VTD). Results: The frequency of vocal fold palsy did not differ significantly statistically in the study group and the control group. Both in the study group and in the control group, patients with vocal fold paralysis had statistically significantly higher results in the VHI and VTD questionnaires as well as in the GRBAS study. Conclusion: Patients with recurrent laryngeal nerve injury show significant differences in the scope of voice handicap, both in the voice quality assessment with the use of the GRBAS scale, and self-evaluation questionnaires: VHI and VTD. All voice disorders evaluated with self-assessment are medium voice disability
Źródło:
Polish Journal of Otolaryngology; 2021, 75, 5; 16-23
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of High Speed Digital Imaging (HSDI) technique and voice acoustic analysis in the diagnosis of the clinical form of Presbyphonia in women
Autorzy:
Kosztyła-Hojna, Bożena
Duchnowska, Emilia
Zdrojkowski, Maciej
Łobaczuk-Sitnik, Anna
Biszewska, Jolanta
Powiązania:
https://bibliotekanauki.pl/articles/1397305.pdf
Data publikacji:
2020
Wydawca:
Index Copernicus International
Tematy:
acoustic analysis
clinical voice assessment
High-Speed Digital Imaging
Presbyphonia
vocal folds vibration
voice changes
Opis:
Introduction: The aging process of voice begins after the age of 60 and has an individually variable course. Voice quality disorders at this age are called senile voice (Presbyphonia or Vox Senium). Voice pathology is particularly severe in women. The aim of the study was to diagnose the clinical form of Presbyphonia in elderly women using High Speed Digital Imaging (HSDI) and acoustic voice analysis. Material and methods: Study included 50 elderly women (average age 69) with dysphonia (Group I). Control group (Group II) included 30 women (average age 71) without voice quality disorders. Visualization assessment has been conducted with High Speed Digital Imaging (HSDI) with High Speed camera (HS). Acoustic evaluation of voice included analysis isolated vowel “a” and continuous linguistic text with Diagnoscope Specialista software. Maximum Phonation Time (MPT) has been determined. Results: In Group I, 78% of women revealed vocal folds vibrations asymmetry, vibration amplitude increase, Mucousal Wave (MW) limitation and Type D glottal insufficiency (GTs). Acoustic voice analysis proved decrease in F0, increase in Jitter, Shimmer, NHR. In 22% of women, next to vibrations asymmetry, vibration amplitude reduction and MW limitation, Type E glottal insufficiency (GTs) have been found. Acoustic voice analysis revealed slight decrease in F0 and the presence of numerous non-harmonic components in the glottis region. Conclusions: Vocal folds visualization with HSDI showed edema, less often atrophy in elderly women. Both forms of dysphonia were caused abnormal values of F0, Jitter, Shimmer, NHR in the acoustic voice evaluation and significant reduction of MPT.
Źródło:
Polish Journal of Otolaryngology; 2020, 74, 5; 24-30
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Samoocena głosu w świetle analizy akustycznej – studia przypadków
Voice Self‑Assessment in the Light of Acoustic Analysis – Case Studies
Autorzy:
Majdak, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/28408990.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
Skala Niepełnosprawności Głosu (VHI)
VHI‑POL
samoocena głosu
obiektywna ocena głosu
kształcenie głosu i mowy
pedagogika głosu
Voice Handicap Index (VHI)
VHI-POL
voice self-assessment
objective voice assessment
voice and speech training
voice pedagogy
Opis:
Celem artykułu jest porównanie wyników subiektywnej i obiektywnej oceny głosu studentów podyplomowych studiów Kształcenie głosu i mowy Uniwersytetu SWPS w Warszawie. Materiał badawczy składa się z nagrań głosów studentów oraz kwestionariuszy Voice Handicap Index (VHI) uzyskanych na początku i na końcu nauki. Wybrano pięć studiów przypadku: trzech studentek, które zostały poddane obserwacji długoterminowej (dwa lub trzy semestry nauki), tak by pokazać różne układy zależności zachodzące między oceną subiektywną a obiektywną, oraz dwóch studentek, dla których porównano wyniki kwestionariusza VHI, gdzie odstęp między pomiarami wynosił trzy tygodnie. Zestawienie wyników oceny subiektywnej i obiektywnej wskazało różny stopień ich zgodności. W szczególności w przypadku nr 2 suma punktów w VHI wzrosła po trzech semestrach nauki o niemal 100% (co oznaczałoby dużą niesprawność głosu i kwalifikowało osobę do pilnej konsultacji foniatrycznej), podczas gdy analiza akustyczna nie odzwierciedliła takiej zmiany. Rozbieżności między wynikami uzyskanymi za pomocą obu metod prowadzą do wniosku, że narzędzia obiektywnej i subiektywnej oceny powinny być stosowane łącznie, najlepiej z innymi metodami badania głosu, tak by jego ocena była możliwie kompleksowa. Przy interpretacji wyników kwestionariusza VHI należy brać pod uwagę wpływ czynników psychicznych. Wzrost świadomości następujący w procesie nauczania emisji głosu w powiązaniu z perfekcjonizmem i krytycyzmem może prowadzić do pogorszenia postrzegania jakości głosu przez badanego.
The article aims to compare the results of the subjective and objective assessment of the voice of students of Postgraduate Studies of Voice and Speech Training at the University of Social Sciences and Humanities in Warsaw. The research material consists of recordings of students’ voices and the Voice Handicap Index (VHI) questionnaires obtained at the beginning and at the end of the study. Five case studies were selected: three female students who were subjected to long‑term follow‑up (two or three semesters of study) to show the different relations between subjective and objective evaluation, and two female students for whom the results of the VHI questionnaire were compared, where the interval between measurements was three weeks. A comparison of the results of subjective and objective evaluation indicated a different degree of compatibility between them. In case 2 particular, the results of voice self‑assessment increased by almost 100% after three semesters of study while the acoustic analysis did not reflect such a change. The discrepancies between the results obtained by the two methods lead to the conclusion that the objective and subjective assessment tools should be used together, preferably with other voice testing methods so that its evaluation is as comprehensive as possible. When interpreting the results of the VHI questionnaire, the influence of psychological factors should be taken into account. Increased consciousness that follows in the process of teaching voice production coupled with perfectionism and criticism can lead to a deterioration in the examinee’s perception of voice quality.
Źródło:
Logopaedica Lodziensia; 2023, 8; 65-78
2544-7238
2657-4381
Pojawia się w:
Logopaedica Lodziensia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wyników analizy cepstralnej z innymi parametrami oceny głosu u pacjentów z dysfoniami zawodowymi
Comparison of cepstral coefficients to other voice evaluation parameters in patients with occupational dysphonia
Autorzy:
Niebudek-Bogusz, Ewa
Strumiłło, Paweł
Wiktorowicz, Justyna
Śliwińska-Kowalska, Mariola
Powiązania:
https://bibliotekanauki.pl/articles/2166319.pdf
Data publikacji:
2014-11-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
kompleksowa ocena głosu
współczynniki cepstralne MFCC
zawodowe zaburzenia głosu
complex voice assessment
mel-cepstral coefficients
MFCCs
occupational voice disorders
Opis:
Wprowadzenie: W ostatnim czasie wśród obiektywnych metod oceny głosu uznaniem cieszy się analiza akustyczna oparta na wyznaczaniu współczynników cepstralnych MFCC (mel-frequency cepstral coefficients). Celem badania była ocena ich zastosowania w diagnozowaniu dysfonii zawodowych w porównaniu z innymi subiektywnymi i obiektywnymi parametrami diagnostycznymi zaburzeń głosu. Materiał i metody: W badaniu wzięły udział 2 grupy kobiet: grupa badana - 55 nauczycielek (średni wiek: 45 lat) z dysfoniami o podłożu zawodowym, potwierdzonymi badaniem laryngowideostroboskopowym, oraz grupa porównawcza - 40 kobiet z głosem prawidłowym (średni wiek: 43 lata). Próbki dźwiękowe (samogłoska ‘a' oraz 4 znormalizowane fonetycznie zdania) poddano analizie MFCC. Wyniki porównano z parametrami akustycznymi (z grupy jittera, z grupy shimmera, parametrem oceny szumów NHR i współczynnikiem chrypki Yanagihary), parametrem aerodynamicznym (maksymalnym czasem fonacji) i parametrami subiektywnymi (skalą percepcyjną GRBAS i wskaźnikiem niepełnosprawności głosowej VHI). Wyniki: Analiza cepstralna wykazała znaczące różnice między grupą badaną a porównawczą, istotne dla współczynników MFCC2, MFCC3, MFCC5, MFCC6, MFCC8, MFCC10, szczególnie dla MFCC6 (p < 0,001) oraz dla MFCC8 (p < 0,009), co może sugerować ich przydatność kliniczną. Z kolei w grupie badanej MFCC4, MFCC8 i MFCC10 istotnie korelowały z większością zastosowanych parametrów obiektywnych oceny głosu. Ponadto współczynnik MFCC8, który u badanych nauczycielek korelował istotnie z wszystkimi ww. 8 parametrami obiektywnymi, wykazał też istotną zależność z cechą dystynktywną A (asthenity) subiektywnej skali GRBAS, cechującej głos słaby, zmęczony. Wnioski: Analiza cepstralna, oparta na wyznaczaniu współczynników MFCC, jest dobrze rokującym narzędziem do obiektywnej diagnostyki dysfonii zawodowych, które bardziej niż inne metody analizy akustycznej odzwierciedla cechy percepcyjne głosu. Med. Pr. 2013;64(6):805–816
Background: Special consideration has recently been given to cepstral analysis with mel-frequency cepstral coefficients (MFCCs). The aim of this study was to assess the applicability of MFCCs in acoustic analysis for diagnosing occupational dysphonia in comparison to subjective and objective parameters of voice evaluation. Materials and Methods: The study comprised 2 groups, one of 55 female teachers (mean age: 45 years) with occupational dysphonia confirmed by videostroboscopy and 40 female controls with normal voice (mean age: 43 years). The acoustic samples involving sustained vowels "a" and four standardized sentences were analyzed by computed analysis of MFCCs. The results were compared to acoustic parameters of jitter and shimmer groups, noise to harmonic ratio, Yanagihara index evaluating the grade of hoarseness, the aerodynamic parameter: maximum phonation time and also subjective parameters: GRBAS perceptual scale and Voice Handicap Index (VHI). Results: The compared results revealed differences between the study and control groups, significant for MFCC2, MFCC3, MFCC5, MFCC6, MFCC8, MFCC10, particularly for MFCC6 (p < 0.001) and MFCC8 (p < 0.009), which may suggest their clinical applicability. In the study group, MFCC4, MFCC8 and MFCC10 correlated significantly with the major objective parameters of voice assessment. Moreover, MFCC8 coefficient, which in the female teachers correlated with all eight objective parameters, also showed the significant relation with perceptual voice feature A (asthenity) of subjective scale GRBAS, characteristic of weak tired voice. Conclusions: The cepstral analysis with mel frequency cepstral coefficients is a promising tool for evaluating occupational voice disorders, capable of reflecting the perceptual voice features better than other methods of acoustic analysis. Med Pr 2013;64(6):805–816
Źródło:
Medycyna Pracy; 2013, 64, 6; 805-816
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Severity of dysphonia in patients during first days after iatrogenic injury
Autorzy:
Jędra, Katarzyna
Sielska-Badurek, Ewelina
Niemczyk, Kazimierz
Powiązania:
https://bibliotekanauki.pl/articles/1398497.pdf
Data publikacji:
2017
Wydawca:
Index Copernicus International
Tematy:
vocal fold paralysis
dysphonia
functional assessment of voice
Opis:
Introduction: The most common cause of vocal fold paralysis (VFP) is iatrogenic injury. Patients with symptoms of VFP present to the specialist after a couple of weeks or even months since the onset of symptoms. In the literature, the data regarding speech impairment during the first days after a iatrogenic injury is lacking. Aim: to evaluate the quality of voice during first days of vocal fold paralysis following a iatrogenic injury. Materials and methods: Twenty-five patients with iatrogenic vocal fold paralysis who presented for phoniatric consultation at the Department of Otolaryngology of the Medical University of Warsaw between May 2015 and December 2016 were enrolled in the study. The patients were examined 1-2 days since the onset of speech deterioration. In all patients, laryngeal videolaryngostroboscopy was performed, based on which the following were assessed: vocal fold mobility, mucosal wave, phonation closure, simultaneity and amplitude of vocal fold vibration. Acoustic analysis was performed, and the following acoustic parameters were evaluated: DSI, F0, Shimmer, Jitter, NHR. Also, the maximal phonation time of [a] sound (MPT a) was assessed and the voice perception analysis with the GRBAS scale was performed. The patients self-evaluated their voice using a 10-point VAS scale. Results: Based on the videolaryngostroboscopy, phonatory insufficiency and asymmetrical vocal fold vibration were observed. On perception assessment with GRBAS scale, we noticed slight to mild degree hoarseness, breathiness of sound and weakened voice. In majority of patients, the maximal phonation time of [a] sound was significantly reduced. All patients showed abnormal acoustic parameters. None of them rated their voice as perfectly normal on VAS scale.
Źródło:
Polish Journal of Otolaryngology; 2017, 71, 6; 22-26
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of stage fright on activities and sensations within the vocal tract
Autorzy:
Kosmowska, Aneta
Sielska-Badurek, Ewelina
Niemczyk, Kazimierz
Powiązania:
https://bibliotekanauki.pl/articles/1400403.pdf
Data publikacji:
2017
Wydawca:
Index Copernicus International
Tematy:
social anxiety
palpation assessment
voice quality
voice discomfort
Opis:
Introduction: Stage fright is a symptom of excessive emotional arousal, and it is commonly referred to as social anxiety. This type of anxiety results mainly from a sense of being judged by others in a given social situation. Materials and Methods: We enrolled 27 female students, aged 22-30 years. We used two methods to examine the influence of stage fright on the activities and sensations within the vocal tract; namely, palpation assessment and the Vocal Tract Discomfort and Voice Quality questionnaire, which were performed twice, i.e., shortly after a presentation in front of an audience and after a normal conversation. The purpose of the study was to assess the impact of stage fright on actions and sensations within the vocal tract. Results: Participants had significantly higher scores with regard to palpation assessment, discomfort, and voice quality after presentations in front of an audience than after normal conversations, indicating a negative impact of stage fright on the studied parameters. Discussion: Stage fright significantly affects activities within the vocal tract structures such as the submandibular region, lateral pharyngeal walls, sternocleidomastoid muscles, and cricothyroid and thyrohyoid spaces; also, it affects jaw mobility and breathing patters. In addition, stage fright induces negative sensations within the vocal tract such as burning, tension, dryness, jaw clenching, throat tightness, grunting, shallow breathing, voice tremor, hoarseness, and faltering voice. The feeling of discomfort during situations that elicit stage fright correlates with self-assessed voice quality.
Źródło:
Polski Przegląd Otorynolaryngologiczny; 2017, 6, 3; 1-9
2084-5308
2300-7338
Pojawia się w:
Polski Przegląd Otorynolaryngologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Screening value of V-RQOL in the evaluation of occupational voice disorders
Autorzy:
Morawska, Joanna
Niebudek-Bogusz, Ewa
Wiktorowicz, Justyna
Śliwińska-Kowalska, Mariola
Powiązania:
https://bibliotekanauki.pl/articles/2162668.pdf
Data publikacji:
2018-03-09
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
screening
self-assessment
dysphonia
occupational voice
voice disorders
biopsychosocial impact
Opis:
Background Given the growing number of occupational voice users, easy and quick broad-scale screening is necessary to provide prophylaxis of voice disorders. The aim of the study was to assess applicability of the Voice Related Quality of Life questionnaire (V-RQOL) to screening occupational voice disorders. Material and Methods The research comprised 284 subjects divided into 3 groups: 0 – the control group of normophonic subjects, non-professional voice users (N = 60), 1 – occupational voice users with objectively confirmed voice disorders (N = 124), 2 – the non-randomized group of occupational voice users with and without voice problems (N = 100). Self-assessment of voice was performed by means of the V-RQOL in comparison to the Voice Handicap Index (VHI). The relation between the V-RQOL and VHI was determined by means of linear regression. Receiver Operating Characteristic (ROC) curves were constructed and the cut-off point of the V-RQOL was determined to discriminate between normophonic and dysphonic subjects. Results The relationship between the VHI and V-RQOL scores indicated a satisfactory coefficient of determination: R² = 0.7266. High values of Cronbach’s α confirmed high reliability of the V-RQOL test (0.867). Voice-Related Quality of Life questionnaire (V-RQOL) results were significantly worse in the study group than for normophonic controls (p < 0.001). The cut-off point for the test was set at 79 points. The determined area under the curve (AUC) = 0.910 (p < 0.001) showed high diagnostic accuracy of the V-RQOL. Results of the V-RQOL differed for diagnose-based subgroups of dysphonic patients. Conclusions The study gives grounds for application of the V-RQOL as a reliable tool for screening occupational voice disorders. Med Pr 2018;69(2):119–128
Źródło:
Medycyna Pracy; 2018, 69, 2; 119-128
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wyników skali dyskomfortu traktu głosowego z obiektywnymi i instrumentalnymi parametrami badania foniatrycznego u nauczycieli rehabilitowanych z powodu zaburzeń głosu
Comparison of vocal tract discomfort scale results with objective and instrumental phoniatric parameters among teacher rehabilitees from voice disorders
Autorzy:
Woźnicka, Ewelina
Niebudek-Bogusz, Ewa
Wiktorowicz, Justyna
Śliwińska-Kowalska, Mariola
Powiązania:
https://bibliotekanauki.pl/articles/2168417.pdf
Data publikacji:
2014-10-30
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
dysfonia
samoocena głosu
skala VTD
rehabilitacja głosu
dysphonia
self-assessment
VTD scale
voice rehabilitation
Opis:
Wprowadzenie: W postępowaniu diagnostyczno-terapeutycznym w dysfoniach zawodowych ważną rolę odgrywa samoocena głosu, która jest jednym z elementów kompleksowej ewaluacji zaburzeń głosu. Celem pracy była ocena możliwości zastosowania skali Dyskomfortu Traktu Głosowego (Vocal Tract Discomfort - VTD) w monitorowaniu skuteczności rehabilitacji głosowej, a także porównanie wyników skali VTD z obiektywnymi i instrumentalnymi metodami diagnostyki foniatrycznej. Materiał i metody: Badaniami objęto 55 nauczycieli (średnia wieku: 47,2 lat) z dysfoniami o podłożu zawodowym. Przeprowadzono kompleksową diagnostykę uwzględniającą: samoocenę głosu według skali VTD, badanie foniatryczne z wideostroboskopią, a także pomiar obiektywnego parametru aerodynamicznego - maksymalnego czasu fonacji (MCF). Po 4-miesięcznej intensywnej rehabilitacji głosu wykonano badanie kontrolne z zastosowaniem ww. metod. Wyniki: Po leczeniu uzyskano istotną poprawę w odniesieniu do subiektywnych dolegliwości mierzonych za pomocą skali VTD - zarówno w podskali częstotliwości (p = 0,000), jak i nasilenia (p = 0,000). Pozytywne efekty terapii stwierdzono także dla parametrów ocenianych w badaniu foniatrycznym (p < 0,01) i wideostroboskopowym (p < 0,01). Po rehabilitacji głosu poprawił się też obiektywny parametr MCF, który wydłużył się średnio o 5 s. Badania wykazały, że Skala Dyskomfortu Traktu Głosowego cechuje się wysoką rzetelnością - współczynnik α-Cronbacha w badaniu wstępnym wynosił: dla podskali częstotliwości symptomów - 0,826, dla podskali nasilenia - 0,845. Analogicznie wysoki był w badaniu kontrolnym i wynosił odpowiednio: 0,908 i 0,923. Wnioski: Skala Dyskomfortu Traktu Głosowego może być wartościowym narzędziem oceny głosu, wykorzystywanym także do monitorowania skuteczności terapii dysfonii zawodowych. Med. Pr. 2013;64(2):199–206
Background: Diagnostic and therapeutic procedures of occupational dysphonia play a major role in voice self-assessment, which is one of the elements of a comprehensive evaluation of voice disorders. The aim of the study was to assess the applicability of the Vocal Tract Discomfort (VTD) scale to monitor the effectiveness of voice rehabilitation and compare the VTD results with objective and instrumental methods of phoniatric diagnosis. Materials and Methods: The study included 55 teachers (mean age, 47.2) with occupational dysphonia. A comprehensive diagnosis took into account self-assessment by VTD scale, phoniatric examination, including laryngovideostroboscopy (LVSS) and objective measurements of the aerodynamic parameter - the maximum phonation time (MPT). After 4 months of intense rehabilitation, post-therapy examination was performed using the methods specified above. Results: After the treatment, a significant improvement was obtained in the subjective symptoms measured on a VTD scale - assessed both for the frequency (p = 0.000) and the severity (p = 0.000) subscales. Positive effects of the therapy were also observed for the parameters evaluated in the phoniatric study (p < 0.01) and laryngovideostroboscopy (p < 0.01). After voice therapy, there was also an improvement in the objective parameter MCF, which was about 5 seconds longer. Studies have shown that the VTD scale is characterized by high reliability - Cronbach's alpha coefficient in the preliminary test was as follows: for the frequency subscale symptoms - 0.826, and severity - 0.845; similarly high reliability was achieved in the control test, 0.908 and 0.923, respectively. Conclusions: Vocal Tract Discomfort scale can be a valuable tool for assessing voice, and can also be used to monitor the effectiveness of therapy of the occupational dysphonia. Med Pr 2013;64(2):199–206
Źródło:
Medycyna Pracy; 2013, 64, 2; 199-206
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laryngeal manual therapy palpatory evaluation scale: A preliminary study to examine its usefulness in diagnosis of occupational dysphonia
Autorzy:
Woźnicka, Ewelina
Niebudek-Bogusz, Ewa
Morawska, Joanna
Wiktorowicz, Justyna
Śliwińska-Kowalska, Mariola
Powiązania:
https://bibliotekanauki.pl/articles/2164115.pdf
Data publikacji:
2017-03-24
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
assessment
occupational voice disorders
palpation
larynx
laryngeal manual therapy palpatory evaluation scale
laryngeal muscle tension
Opis:
Background The aim of this study has been to assess the larynx and soft tissue around the vocal tract in a group of people with healthy voice, and in a group of patients with occupational dysphonia using the new laryngeal manual therapy palpatory evaluation scale (LMTPE). Material and Methods The examinations were performed in a study (dysphonic) group of professional voice users who had developed voice disorders (N = 51) and in the control group of normophonic subjects (N = 50). All the participants underwent perceptual voice assessment and examination by means of the LMTPE scale. Additionally, phoniatric examination including VHI (Voice Handicap Index) questionnaire, GRBAS (the Grade of hoarseness, Roughness, Breathiness, Asthenic, Strained) perceptual evaluation, maximum phonation time (MPT) measurement and videostroboscopy was performed in the study group. Results The comparison of the LMTPE total score showed that the results of the study group were significantly poorer than those of controls (p < 0.001). In the study group, correlations were found between the LMTPE results and the VHI scores (p < 0.05), perceptual evaluation by the GRBAS (p < 0.05) and the objective parameter MPT (p < 0.05). Conclusions The study has proven that the LMTPE scale is characterized by the high score of Cronbach’s α ratio estimating the reliability of the test. The results have confirmed that the LMTPE scale seems to be a valuable tool, useful in diagnostics of occupational dysphonia, particularly of hyperfunction origin. Med Pr 2017;68(2):179–188
Źródło:
Medycyna Pracy; 2017, 68, 2; 179-188
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Functional and Performance Characteristics Including Principles of Placing the Elements of Voice Alarm Systems on the Market
Właściwości funkcjonalne i eksploatacyjne oraz zasady wprowadzania do obrotu elementów dźwiękowych systemów ostrzegawczych
Autorzy:
Pergał, Szymon
Powiązania:
https://bibliotekanauki.pl/articles/2060749.pdf
Data publikacji:
2021
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
voice alarm systems
loudspeaker
maintenance
conformity assessment
phased evacuation
dźwiękowe systemy ostrzegawcze
głośnik
konserwacja
ocena zgodności
ewakuacja stopniowa
Opis:
Aim: The aim of the article was to present voice alarm systems and discuss the legitimacy of their use in fire alarm systems. The article presents the principles of introducing the elements of voice alarm systems to the market and their functional and operational properties. The article was written on the basis of a master’s thesis entitled “The analysis of the functional and operational properties of voice alarm systems” submitted at the Faculty of Safety and Civil Protection Engineering of the Main School of Fire Service. Introduction: Voice alarm system is one of the methods of warning the users of facilities about a threat, but there are many methods of alerting, e.g. sounders or optic signalling devices. Each of the above-mentioned systems has its advantages and disadvantages, so the application of the appropriate system, regardless of whether the regulations impose this obligation on the investor or it will be done on investor's own require deep consideration. Methods: There are several legal acts in force in Poland that define various aspects of voice alarm systems. Facilities in which the use of voice alarm systems (VAS) is mandatory are listed in the Regulation of the Minister of Interior and Administration of 7 June 2010 on fire protection of buildings, other construction facilities and areas. In turn, the specification of the documents required for individual VAS elements is specified in the Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 establishing harmonized conditions for the marketing of construction products and repealing Council Directive 89/106/EEC and additionally in Poland in the annex to the regulation of the Minister of Interior and Administration of 20 June 2007 on the list of products used to ensure public safety or protection of health and life and property, as well as the rules for issuing admittance for use of these products. Results: It has been found that many elements of voice alarm systems require careful analysis. Starting with the conformity assessment of the system components through its parameters, such as speech intelligibility, coverage angles or the appropriate sound pressure level. It is also important to select the system for the intended functional use of the rooms and to verify the correct operation of the system after changing the arrangement. Conclusions: Voice alarm systems are a very good, but relatively expensive system. They allow for a very diverse operation and facilitate appropriate evacuation. However, despite the high costs, it is worth considering their installation due to the invaluable action in terms of ensuring the safety of the users of the facility and the protection of their lives.
Cel: Celem artykułu było zaprezentowanie dźwiękowych systemów ostrzegawczych oraz omówienie zasadności ich stosowania w systemach sygnalizacji pożarowej. W artykule przedstawiono zasady wprowadzania do obrotu elementów dźwiękowych systemów ostrzegawczych oraz ich właściwości funkcjonalne i eksploatacyjne. Artykuł został napisany na podstawie pracy magisterskiej pt. „Analiza właściwości funkcjonalnych i eksploatacyjnych dźwiękowych systemów ostrzegawczych” złożonej w Szkole Głównej Służby Pożarniczej na Wydziale Inżynierii Bezpieczeństwa i Ochrony Ludności. Wprowadzenie: Dźwiękowy system ostrzegawczy jest jedną z metod ostrzegania użytkowników obiektów o zagrożeniu, jednak metod alarmowania jest wiele, np. sygnalizatory akustyczne czy sygnalizatory optyczne. Każdy z przytoczonych systemów ma swoje wady i zalety, dlatego należy dobrze przemyśleć zastosowanie odpowiedniego systemu niezależnie od tego, czy przepisy nakładają na inwestora ten obowiązek, czy zrobi to we własnym zakresie. Metody: W Polsce obowiązuje kilka aktów prawnych określających różne aspekty dotyczące dźwiękowych systemów ostrzegawczych. Obiekty, w których obligatoryjne jest stosowanie dźwiękowych systemów ostrzegawczych (DSO), zostały wymienione w rozporządzeniu Ministra Spraw Wewnętrznych i Administracji z dnia 7 czerwca 2010 r. w sprawie ochrony przeciwpożarowej budynków, innych obiektów budowlanych i terenów. Z kolei określenie dokumentów wymaganych dla poszczególnych elementów DSO precyzuje rozporządzenie Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG oraz dodatkowo na terenie Rzeczpospolitej Polskiej w załączniku do rozporządzenia Ministra Spraw Wewnętrznych i Administracji z dnia 20 czerwca 2007 r. w sprawie wykazu wyrobów służących zapewnieniu bezpieczeństwa publicznego lub ochronie zdrowia i życia oraz mienia, a także zasad wydawania dopuszczenia tych wyrobów do użytkowania. Wyniki: Stwierdzono, że wiele elementów dźwiękowych systemów ostrzegawczych wymaga dokładnej analizy. Poczynając od oceny zgodności części składowych systemu przez jego parametry, takie jak zrozumiałość mowy, kąty pokrycia czy odpowiedni poziom ciśnienia akustycznego. Ważny jest również dobór systemu do zamierzonego wykorzystania funkcjonalnego pomieszczeń oraz weryfikacja poprawności działania systemu po zmianie aranżacji. Wnioski: Dźwiękowe systemy ostrzegawcze są bardzo dobrym, jednak stosunkowo drogim systemem. Pozwalają one na bardzo zróżnicowane działanie oraz ułatwiają odpowiednie prowadzenie ewakuacji. Mimo wysokich kosztów warto jednak rozważyć ich instalację z uwagi na nieocenione działanie w zakresie zapewnienia bezpieczeństwa użytkowników obiektu oraz ochrony ich życia.
Źródło:
Safety and Fire Technology; 2021, 57, 1; 26--40
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena predyspozycji operatora w zadaniach decyzyjnych w inteligentnym systemie interakcji z urządzeniami technicznymi
Assessment of operators ability for decision making tasks in intelligent interaction system with technical devices
Autorzy:
Kacalak, W.
Majewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/154120.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ocena predyspozycji operatora
interakcja operatora z urządzeniem technicznym
komunikacja głosowa
interfejs mowy
sztuczna inteligencja
assessment of operator's ability
interaction between the operator and technical devices
voice communication
speech interface
artificial intelligence
Opis:
W artykule przedstawiono nową koncepcję oceny predyspozycji operatora w zadaniach decyzyjnych w inteligentnych systemach interakcji z urządzeniami technicznymi. Opracowany inteligentny system dokonuje analizy, sprawdzania i oceny predyspozycji operatora oraz nadzorowania i optymalizacji procesu oceny. System oceny predyspozycji przedstawiono w przykładowym zastosowaniu w systemie interakcji za pomocą mowy i języka naturalnego pomiędzy urządzeniami technicznymi i ich operatorami, który zawiera inteligentne mechanizmy służące do identyfikacji biometrycznej operatora, rozpoznawania słów składowych i całych komunikatów operatora, analizy składni i skutków poleceń, oceny bezpieczeństwa poleceń, nadzorowania procesu, oraz oceny reakcji operatora.
In this paper, a new concept of assessment of operator's ability for decision making tasks in intelligent interaction systems with technical devices is presented. The developed intelligent system performs analyses, evaluation and assessment of operator's ability, as well as supervision and optimization of the assessment process. The assessment system of operator's ability is presented in exemplary application in an interaction system by speech and natural language between technical devices and their operators, which consists of the intelligent mechanisms of operator biometric identification, speech recognition, word and command recognition, command meaning and effect analysis, command safety assessment, process supervision, and operator reaction assessment. In the paper, a review of selected issues is carried out with regards to intelligent interaction layers (Fig. 1), process supervision systems (Fig. 2), intelligent interaction systems (Figs. 3, 4), assessment of operator's ability for decision making tasks (Figs. 5, 6, 7), as well as recognition and evaluation of speech commands in natural language. Application of hybrid neural networks allows recognition of commands in natural language with similar meanings but different lexico-grammatical patterns, which will undoubtedly be the most important way of interaction between humans and devices. The condition of the effectiveness of the presented system is to equip it with mechanisms of command meaning and effect analysis, as well as safety assessment. The condition for safe communication between operators and technical devices is analyzing the state of the technical device and process before the command is given and using artificial intelligence for effect analysis and safety assessment of the command. The development of a basis of building and applying systems of control, supervision and optimization of processes which communicate an operator with a technical device, is an important goal. These systems allow remote control of the process quality by an operator being in any distance. It is very significant for development of new effective and flexible methods of control. The system for remote control, supervision and optimization provides an innovative solution using more complete advantages of applied technological processes nowadays. The presented solution can belong to attempts of creation of the standard of mobile applications for control, supervision and optimization of processes using two-way speech communication between technical devices and their operators.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 5, 5; 515-518
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies