Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "vibration measurement" wg kryterium: Temat


Tytuł:
Concept of a system for remote vibration measurement in electric vehicles driven by rotaring body motors
Autorzy:
Syroka, Zenon
Powiązania:
https://bibliotekanauki.pl/articles/2133932.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
vibration
electric vehicle
vibration measurement
Opis:
The article proposes a vibration measurement system for electric vehicles powered by motors with rotating housing. The motors were designed and patented by the author. The presented solution is characterized by low cost, high reliability and minimal power consumption. Block diagrams of the designed system were presented and described in detail.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2022, 25(1); 77--85
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Digital Vibration Sensor Constructed with MEMS Technology
Autorzy:
Mazurek, G.
Powiązania:
https://bibliotekanauki.pl/articles/227320.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
accelerometer
vibration measurement
MEMS
Opis:
In this paper, a new digital sensor of acceleration is described. The sensor is based on MEMS device and is capable of measuring both static (gravity) and dynamic (vibration) accelerations. Its primary application is the measurement of vibrations in buildings and other constructions. The aim of this project was to design a low-cost, small-weight small-size acceleration sensor that can operate within simple sensor networks.
Źródło:
International Journal of Electronics and Telecommunications; 2012, 58, 2; 117-122
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Roughness Parameters Calculation By Means Of On-Line Vibration Monitoring Emerging From AWJ Interaction With Material
Autorzy:
Hreha, P.
Radvanska, A.
Knapcikova, L.
Królczyk, G. M.
Legutko, S.
Królczyk, J. B.
Hloch, S.
Monka, P.
Powiązania:
https://bibliotekanauki.pl/articles/221321.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
abrasive water jet
surface topography
material vibration
vibration measurement
Opis:
The paper deals with a study of relations between the measured Ra, Rq, Rz surface roughness parameters, the traverse speed of cutting head v and the vibration parameters, PtP, RMS, vRa, generated during abrasive water jet cutting of the AISI 309 stainless steel. Equations for prediction of the surface roughness parameters were derived according to the vibration parameter and the traverse speed of cutting head. Accuracy of the equations is described according to the Euclidean distances. The results are suitable for an on-line control model simulating abrasive water jet cutting and machining using an accompanying physical phenomenon for the process control which eliminates intervention of the operator.
Źródło:
Metrology and Measurement Systems; 2015, 22, 2; 315-326
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie technologii MEMS w nowoczesnym sterowniku pralki do kontroli drgań bębna
MEMS Technology Application In Modern Washing Machine Driver for Drum Vibration Control
Autorzy:
Pittner, G.
Rybarczyk, D.
Owczarek, P.
Powiązania:
https://bibliotekanauki.pl/articles/276637.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pomiary drgań
pralki
MEMS
vibration measurement
washing machine
Opis:
Artykuł przedstawia możliwość zastosowania technologii MEMS przy pomiarach wibracji bębna maszyny wirującej przez jej sterownik na przykładzie klasycznej pralki. W artykule przedstawiono pokrótce samą technologię MEMS pod kątem pomiarów akcelerometrycznych oraz omówiono zjawisko powstawania siły niewyrównoważenia wirującego bębna pralki, którą to akcelerometr ma zmierzyć. W drugiej części artykułu przedstawiono wyniki porównania pomiarów drgań wirującego bębna za pomocą sensora MEMS oraz klasycznego piezoelektrycznego akcelerometru pomiarowego. Wyniki badań udowadniają tezę o potencjalnej możliwości zastosowania technologii MEMS w gałęzi przemysłu jaką są konstrukcje urządzeń AGD - w szczególności pralek.
Paper introduce possibilities of MEMS technology application for measurement of the rotating drum vibration in washing machine construction. The MEMS technology has been shortly presented and focused on its acceleration measurement aspects. Also generation of the unbalance force in washing machine drum has been considered. In the second part of the paper the results of the experimental comparison of the classic piezoelectric and MEMS sensors has been presented and discussed.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 2; 351-356
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wireless sensors network for vibration measurements
Czujniki bezprzewodowe do pomiarów drgań
Autorzy:
Bojko, T.
Powiązania:
https://bibliotekanauki.pl/articles/158153.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
czujniki bezprzewodowe
pomiary drgań
wireless sensors network
vibration measurement
Opis:
Structural health monitoring (SHM) systems are applied for condition monitoring of machines and structures, structural integrity assessment, damage detection and structural failure prediction. Measurement data acquired by many sensors are essential for SHM, but at a same time application of many sensors located on mechanical structures causes serious technical problems due to wiring of sensors. The wiring is highly time consuming during sensors installation, may change the system output due to high structure loading and damping and often adds signal noise to measured data. To address these disadvantages a research effort has been initiated for development of wireless modular monitoring systems which use independent wireless sensors for data acquisition and signal processing. Successful application of such sensors network is related to proper hardware and software solutions on single sensor node. The main problem in such networks is synchronization of data acquisition within the network of many sensors. In the paper the requirements for smart wireless sensors are specified and discussed. Design of wireless smart sensor for mechanical structures diagnostics is presented.
Zastosowanie aktywnych układów monitorujących stan konstrukcji wymaga zainstalowania wielu czujników pomiarowych. Koszt wykonania okablowania pomiarowego w takich przypadkach jest duży, nie bez znaczenia jest również znaczny czas potrzebny na wykonanie okablowania. W celu zmniejszenia kosztów instalacji i skrócenia czasu uruchomienia systemu monitorujacego stosowane są obecnie bezprzewodowe metody przesyłu danych. Rozwój tej technologii - układów scalonych, protokołów transmisji, oprogramowania, umożliwia budowę miniaturowych bezprzewodowych modułów pomiarowych, które zestawione w system pomiarowy umożliwiają diagnostykę rozległych obiektów. W artykule opisano problemy związane z zastosowaniem bezprzewodowych sieci pomiarowych, opisano budowany w KRiDM AGH system bezprzewodowy oraz wyznaczono kierunki dalszych prac dla prezentowanego systemu.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 5, 5; 12-15
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych czynników konstrukcyjnych na wibroaktywność przekładni zębatych
Influence of selected design factors on the vibroactivity of toothed gears
Autorzy:
Folęga, P.
Powiązania:
https://bibliotekanauki.pl/articles/155127.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar drgań
wibroaktywność
korpus przekładni
vibration measurement
vibroactivity
gearbox housing
Opis:
W ramach badań wyznaczono wibroaktywność przekładni na podstawie pomiarów normalnych prędkości drgań wybranych punktów korpusu przekładni zębatej wykonanych wibrometrem laserowym. Przedstawione w opracowaniu wyniki potwierdzają istotny wpływ dodatkowego użebrowania korpusów przekładni oraz liczby przyporu zazębienia na generowane przez nią drgania. Wykonanie użebrowania górnej części korpusu spowodowało zmniejszenie wibroaktywności przekładni. W badaniach stwierdzono również, że wibroaktywność przekładni obniża się wraz ze wzrostem liczby przyporu zazębienia.
The paper presents the results of stand and numerical tests of gearbox housings, which are part of research aimed at finding a model that would enable minimising the noise and vibration generated by the toothed gear. As part of the stand tests, there was determined the vibroactivity of the toothed gear on a basis of measurements of normal vibration velocities of selected gearbox housing points taken with a laser vibrometer. The results presented in Section 3 confirm the significant influence of additional ribbing of the gearbox housing on the vibration it generates. Ribbing in the gearbox housing upper part resulted in a reduced vibroactivity of the toothed gear (Fig. 4). A significant decrease in the amplitude values of vibration speeds within the range of up to 3.5 kHz was obtained through simultaneous application of additional stiffening ribs, two parallel and one perpendicular to the axis of the shafts (gearbox housing C). It was also found that the toothed gear vibroactivity decreases with increase in the tooth contact ratio (Section 4). The measurement results presented in Fig. 7 show that increase in the pitch contact ratio results in decrease in the gearbox housing vibroactivity. This is caused, first of all, by lower values of the dynamic forces generated in the gear meshing as ?ß increases. While analysing the effect of load on the vibroactivity of the gearbox housing (Fig. 7a and 7b) it can be noted that it grows along with an increasing load.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 6, 6; 602-605
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vibroacoustic testing of prototype hermetic harmonic drive
Autorzy:
Pacana, Jacek
Homik, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1819070.pdf
Data publikacji:
2020
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
vibration measurement
vibroactivity
hermetic harmonic drive
fexspline
circular spline
wave generator
Opis:
This study was designed to determine the vibroactivity parameters of a hermetic harmonic drive. A specially-prepared test bench was used to measure the normal velocity of vibrations and acoustic pressure generated by the unit. Piezoelectric sensors were applied to measure the characteristic values on the body of the prototype. In selected sections of drive, we determined the effective values of acceleration ae and frequency f. For the same points, the effective values of vibration velocity Vc were determined for the corresponding frequencies. The findings presented in this paper enable the assessment of a toothed gear in terms of the quality of its workmanship and wear-related deterioration, which are very important due to the characteristic work of this special drive.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2020, 64 (136); 52-57
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości pomiaru drgań w miejscu kontaktu rąk z ich źródłem
Assessment of vibration measurement possibility at the contact point of hands with the vibration source
Autorzy:
Mrukwa, W.
Świder, J.
Staniek, A.
Powiązania:
https://bibliotekanauki.pl/articles/340718.pdf
Data publikacji:
2002
Wydawca:
Główny Instytut Górnictwa
Tematy:
bezpieczeństwo pracy
drgania narzędzia
ręka
pomiar drgań
work safety
tool vibration
hand
vibration measurement
Opis:
W artykule przedstawiono wyniki wstępnych badań, których celem była ocena możliwości wykonywania pomiarów drgań w miejscu kontaktu rąk człowieka z powierzchnią eksploatowanego narzędzia, obrabianego elementu itp., zalecanych w wielu dokumentach normalizacyjnych, a jednak dotychczas niestosowanych. Istota wspomnianego sposobu pomiaru polega przede wszystkim na zastosowaniu przetwornika drgań o odpowiednich właściwościach. Na podstawie przeglądu literatury przedmiotu oraz bogatego zestawu norm międzynarodowych i krajowych sformułowano założenia do nowej metody pomiaru i określono wynikające z niej wymagania metrologiczne i konstrukcyjne dla przetwornika, który miał umożliwić jej realizację. Wymagania te spełniał udostępniony zespołowi badawczemu prototyp trójosiowego, piezoelektrycznego przetwornika przyspieszenia drgań, oznaczonego roboczym symbolem A3R umieszczonego w obudowie w kształcie płaskiego walca. Przetwornik mocuje się do wewnętrznej powierzchni ręki za pomocą specjalnej opaski. Uzyskanie przetwornika umożliwiło przeprowadzenie badań porównawczych dwóch sposobów lokalizacji miejsc pomiaru, dla rzeczywistych źródeł drgań przenoszonych do rąk, a mianowicie: - trzy przetworniki jednoosiowe zostały zamocowane za pomocą złącza mechanicznego do rękojeści obok ręki operatora - zestaw "standard", - przetwornik A3R został zamocowany do wewnętrznej powierzchni ręki. Jako źródła drgań wykorzystano: wiertarkę udarową o napędzie elektrycznym z wiertłem o średnicy 32 mm oraz samojezdny, wibracyjny zagęszczacz gruntu. Badania wykonywano na specjalnych stanowiskach badawczych, a poszczególne urządzenia były obsługiwane kolejno przez 3-5 osób. Badania polegały na pomiarze metodą pośrednią (rejestracja magnetyczna sygnału + analiza widmowa w czasie rzeczywistym) widm 1/3-oktawowych wartości skutecznej (rms) przyspieszenia drgań w zakresie częstotliwości od 6,3 do 1250 Hz. Wynikiem był zestaw kilkudziesięciu par widm, oddzielnie dla każdego źródła, osi przyjętego układu odniesienia oraz operatora. Uzyskane wyniki pozwoliły na dokonanie jedynie możliwego w tej fazie badań jakościowego porównania widm w poszczególnych parach, tzn. porównania kształtu ich przebiegu, przyjmując jako kryterium oceny widmo, uzyskane za pomocą zestawu "standard". Stwierdzono, że kształt przebiegu widm, uzyskanych w pomiarach wykonanych z wykorzystaniem dwóch różnych sposobów lokalizacji przetworników drgań, we wszystkich analizowanych przypadkach był bardzo zbliżony, z tymi samymi charakterystycznymi maksimami w kilku pasmach częstotliwości. Ocena ilościowa badań była jeszcze niemożliwa. Można jednak przypuszczać, że generalnie wartości przyspieszenia drgań mierzone przetwornikiem typu A3R, pomiędzy ręką operatora a powierzchnią źródła drgań, będą z reguły wyższe od wartości, mierzonych zestawem "standard". Należało tego zresztą oczekiwać ponieważ zestaw "standard" mierzy nie drgania, przenikające ze źródła do rąk operatora, ale drgania, które charakteryzują źródło. Wykonane badania potwierdziły możliwość opracowania metody pomiaru drgań w miejscu kontaktu rąk człowieka z ich źródłem. Uzyskane wyniki powinny stanowić punkt wyjścia do dalszych badań nad sformułowaniem roboczej wersji metody pomiaru, z wykorzystaniem omawianego sposobu lokalizacji przetwornika drgań.
The article presents the results of preliminary investigations, aiming at the assessment of possibility of vibration measurement conducting at the contact point of human hands with the surface of the exploited tool, treated element etc., recommended in many standardization documents, however, not applied hitherto. The essence of the above-mentioned measuring method consists first of all in the use of a vibration converter of adequate properties. On the basis of a publication review relating to this subject, and a set of international and national standards, one has formulated the assumptions concerning a new measuring method, and has determined the resulting from this method metrological and constructional requirements regarding the converter, which should facilitate its realization. These requirements met a prototype of a triaxial, piezoelectric vibration acceleration converter, rendered accessible to the research team, marked with the working symbol A3R, placed in a casing of a flat cylinder form. The converter is fastened to the internal hand surface by means of a special band. The converter enabled to perform comparative tests of two methods of measuring place localization, for actual sources of vibrations transmitted to hands, namely: - three uniaxial converters were fastened, by help of a mechanical joint, to the handle close to the Operator's hand - "standard" set, the converter A3R was fastened to the internal hand surface. As the source of vibrations one has used: a hammer drilling machine with electric drive with a drill of 32 cm diameter, and a self-propelled, vibratory ground thickener. The tests were carried out at special testing stands, and the individual devices were operated in turn by 3-5 persons. The tests consisted in measuring by means of an intermediate method (signal magnetic recording + spectroanalysis in actual time) the spectra of 1/3-octave root-mean-square value (rms) of vibration acceleration within the frequency range from 6.3 Hz to 1250 Hz. The result constituted a set of several dozen of spectrum couples, separately for each source, axis of adopted reference system, and the operator. The obtained results enabled to perform the only one possible, at this phase of investigations, quantitative comparison of the spectra in individual couples, i.e. to compare the shape of their course, assuming as assessment criterion the spectrum, gained by help of the "standard" set One has ascertained that the shape of course of spectra, obtained during measurements carried out with the use of two different methods of vibration converter localization, was similar in all analysed cases, with the same characteristic maxima in several frequency bands. The quantitative assessment of investigations was not yet possible. However, one can suppose, that the vibration acceleration values measured by means of the A3R converter between the operator's hand and the vibration source surface will be, as a general rule, higher than the value, measured by means of the "standard" set. Anyway, this should be expected, because the "standard" set does not measure the vibrations, penetrating from the source to the operator's hands, but the vibrations, which characterize the source. The performed investigations confirmed the possibility to work out the method of vibration measurement at the contact point of human hands with the vibration source. The obtained results should constitute the starting point for future investigations concerning the formulation of the working version of the measuring method, with the use of the described method of vibration converter localization.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2002, 1; 91-102
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System aparaturowy do pomiaru i rejestracji cyfrowej sygnałów mechanograficznych serca oraz EKG
The system for measurement and digital recording of mechanoscopic signals of heart and ECG
Autorzy:
Jamroży, M.
Lewenstein, K.
Powiązania:
https://bibliotekanauki.pl/articles/153019.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
EKG
osłuchiwanie serca
pomiar wibracji
infradźwięki
ECG
heart ausculation
vibration measurement
infrasounds
Opis:
Na podstawie badania osłuchowego klatki piersiowej możliwe jest zdiagnozowanie wielu dolegliwości kardiologicznych w tym także niewydolności mięśnia sercowego. W artykule omówiono problemy napotkane podczas przygotowywania toru pomiarowego mającego za zadanie dokonywanie jednoczesnego pomiaru i akwizycji cyfrowej sygnałów akustycznych, wibracyjnych rejestrowanych na powierzchni skóry pacjenta oraz sygnałów EKG. Przedstawiono rozwiązania układowe zastosowane przy budowaniu stanowiska pomiarowego oraz autorskie oprogramowanie komputerowe - interfejs użytkownika, pozwalający na łatwą i sprawną obsługę wszystkich urządzeń składowych. W szczególności omówiono zagadnienie jednoczesności rejestracji sygnałów próbkowanych w urządzeniach z różnymi generatorami zegarowymi.
Medical signal measurement and analysis is still a big challenge for engineers. Despite a technological development and increase in processing speed, we still have problems with designing the dedicated measurement devices and proceeding with patient's examination. It is very important to guarantee patient's safety and to obey the law with describe conditions of using medical devices. Heart auscultation is conducted during almost each appointment with the doctor. It is possible to diagnose on its basis many cardiological diseases, including cardiac muscle insufficiency. This article discusses problems, which arise while preparing measuring track for simultaneous measurement and acquisition of the digital acoustic data, vibrations registered on the patient's skin surface and ECG signals. We present system solutions applied during constructing measurement station, as well as author's computer software - interface allowing easy and effective service of all the constituent devices. We attach particular importance to the issue of simultaneous registration of sampling signals in the case of devices with different clockwork generators. The aim of the following work is a description of a station which can be used for the data acquisi-tion. After further processing the data will be used for automatic support of the cardiac muscle insufficiency diagnosis and also for enabling early detection of this disease. This problem, although it seems to be simple to solve in the case of detecting strong lesions, becomes complicated when we speak of patients with slight disorders.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 6, 6; 591-594
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recognition of bonding contamination in CFRP composite laminates by measurements of local vibration nonlinearity
Identyfikacja zanieczyszczeń w połączeniach klejonych kompozytów CFRP poprzez pomiary lokalnej nieliniowości drgań
Autorzy:
Solodov, I.
Ségur, D.
Kreutzbruck, M.
Powiązania:
https://bibliotekanauki.pl/articles/107892.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
glue bond
CFRP composite
vibration measurement
połączenie klejowe
kompozyt CFRP
pomiar drgań
Opis:
A new approach based on measurements of a local nonlinear response of the laminate is suggested and applied to characterizing contaminations of adhesive bonding in carbon fibre reinforced polymer (CFRP). It is shown that a contaminated boundary layer of the adhesive contributes to an overall nonlinear response of the laminate that enables to recognise the difference in bonding quality caused by various types and levels of contaminations.
W artykule, w celu scharakteryzowania zanieczyszczeń połączeń klejonych polimerów wzmocnionych włóknem węglowym (CFRP), zaproponowano i następnie zastosowano nowe podejście oparte na pomiarach lokalnej nieliniowej odpowiedzi laminatu. Pokazano, że zanieczyszczona warstwa graniczna kleju przyczynia się do ogólnej nieliniowej odpowiedzi laminatu, która umożliwia rozpoznanie różnicy w jakości wiązania spowodowanej różnymi typami i poziomami zanieczyszczeń.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 1; 3-9
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic calibration system for digital-display vibrometers based on machine vision
Autorzy:
He, W.
Xu, G.
Rong, Z.
Li, G.
Liu, M.
Powiązania:
https://bibliotekanauki.pl/articles/221163.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
image recognition
calibration
vibration measurement
machine vision
automatic testing
digital-display vibrometer
Opis:
Considering the low efficiency during the process of traditional calibration for digital-display vibrometers, an automatic calibration system for vibrometers based on machine vision is developed. First, an automatic vibration control system is established on the basis of a personal computer, and the output of a vibration exciter on which a digital-display vibrometer to be calibrated is installed, is automatically adjusted to vibrate at a preset vibration level and a preset frequency. Then the display of the vibrometer is captured by a digital camera and identified by means of image recognition. According to the vibration level of the exciter measured by a laser interferometer and the recognized display of the vibrometer, the properties of the vibrometer are calculated and output by the computer. Image recognition algorithms for the display of the vibrometer with a high recognition rate are presented, and the recognition for vibrating digits and alternating digits is especially analyzed in detail. Experimental results on the built-up system show that the prposed image recognition methods are very effective and the system could liberate operators from boring and intense calibration work for digital-display vibrometers.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 317-328
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ sposobu mocowania akcelerometrów na poziom rejestrowanych drgań powierzchniowych ośrodka gruntowego
The impact of accelerometer mounting methods on the level of vibrations recorded at ground surface
Autorzy:
Czech, K. R.
Gosk, W.
Powiązania:
https://bibliotekanauki.pl/articles/210862.pdf
Data publikacji:
2014
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
geotechnika
drgania powierzchniowe
ośrodek gruntowy
pomiar drgań
geotechnics
surface vibrations
ground
vibration measurement
Opis:
W pracy prezentowane są wyniki badań terenowych polegających na pomiarze przyspieszeń drgań rejestrowanych na powierzchni ośrodka gruntowego. Źródłem drgań o wysokiej powtarzalności parametrów impulsu była lekka płyta dynamiczna ZFG-01. Pomiary przyspieszeń drgań realizowano przy wykorzystaniu najwyższej klasy i dokładności układu pomiarowego firmy Brüel & Kjær. Akcelerometry montowano na powierzchni gruntu piaszczystego wpunktach pomiarowych rozmieszczonych promieniście wodległości 5 m i 10 m od źródła drgań. W pracy analizowano wpływ sposobu mocowania akcelerometrów na gruncie na poziom rejestrowanych wartości przyspieszeń drgań. Wykazano, że sposób mocowania czujników do powierzchni terenu ma kluczowe znaczenie z punktu widzenia wiarygodności realizowanych pomiarów.
The paper presents the results of field research based on the measurements of accelerations recorded at ground surface. The source of the vibration characterized by high repetition rate of pulse parameters was light falling weight deflectometer ZFG-01. Measurements of vibrations have been carried out using top quality high-precision measuring system produced by Brüel & Kiær. Accelerometers were mounted on a sandy soil surface at the measuring points located radially at 5-m and 10-m distances from the source of vibration. The paper analyses the impact that the method of mounting accelerometers on the ground has on the level of the recorded values of accelerations of vibrations. It has been shown that the method of attaching the sensor to the surface of the ground is crucial for the credibility of the performed measurements.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2014, 63, 3; 65-78
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of a device for measuring and analyzing vibrations
Opracowanie urządzenia do pomiaru i analizy drgań
Autorzy:
Stakhova, Anzhelika
Kvasnikov, Volodymyr
Powiązania:
https://bibliotekanauki.pl/articles/2174705.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
up vibrations
defect
vibroacoustic parameter
vibration measurement
drgania
wady
parametr wibroakustyczny
pomiar drgań
Opis:
It is known that vibration is generated to one degree or another by all moving parts of machines. Vibration processes arising in the process of functioning of machines and equipment are highly informative, reflecting the technical condition of many parts and assemblies quite fully. Therefore, the use of vibration diagnostics systems makes it possible to determine a defect even at the stage of inception, thereby excluding emergency stops of machinery. An urgent task is to create a vibration analysis device, which consists of a sensor for measuring vibration, the principle of operation of which is based on the use of a direct piezoelectric effect. The output signal of the sensor will go to a personal computer or any other device with the Windows operating system, where a spectral analysis of the measured vibration signal is carried out using a Matlab-based diagnostic program.
Wiadomo, że wibracje w mniejszym lub większym stopniu są generowane przez wszystkie ruchome części maszyn. Procesy wibracyjne powstające w trakcie pracy maszyn i urządzeń mają bardzo bogaty charakter informacyjny, w pełni odzwierciedlając stan techniczny wielu części i zespołów. Dlatego zastosowanie systemów diagnostyki drganiowej pozwala na określenie usterki już na etapie jej powstania, wykluczając tym samym awaryjne zatrzymania maszyn. Pilnym zadaniem jest stworzenie urządzenia do analizy drgań, które składa się z czujnika do pomiaru drgań, którego zasada działania opiera się na wykorzystaniu bezpośredniego efektu piezoelektrycznego. Sygnał wyjściowy czujnika trafia do komputera osobistego lub innego urządzenia z systemem operacyjnym Windows, gdzie analiza widmowa mierzonego sygnału drgań jest przeprowadzana za pomocą programu diagnostycznego opartego na Matlabie.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2021, 11, 2; 48--51
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of maximum vibration after the addition of the gorger construction to evaluate the side deck girder construction planning in the ship engine room
Autorzy:
Sugeng, S.
Utomo, B.
Said, S. D.
Yusim, A. K.
Windyandari, A.
Khristyson, S. F.
Afrizal, L.
Jatmiko, A. B.
Sanjiwo, Z. Z.
Powiązania:
https://bibliotekanauki.pl/articles/2172504.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
ship engine room
side deck girder construction
maximum vibration
gorger construction, vibration
ship vibration measurement
side deck girder
girder
Opis:
The greatest vibration occurs in the engine room, but all other parts of the ship also experience vibrations because it is propagating. Even though there are methods to reduce these vibrations such as engine beds, they can only reduce the damaging effects and cannot completely eliminate the vibrations themselves. The method used in this research is to compare the measurement of good vibrations in the conditions before the addition of construction and after the addition of construction for later comparison with numerical calculation data. The purpose of this study is to obtain the maximum vibration value in the conditions after the addition of the gorger construction before the addition of the side deck girder construction as a means of evaluating the side deck girder construction planning in the ship engine room ship 2000 DWT. The result consideration of adding construction becomes one or the alternative in providing reinforcement so that it can reduce the vibration that occurs. From analyze results after addition of a sized T profile FB 180 x 8 mm FP 75 x 10 mm, which ranges from 28 - 29 m/s2 for the x-axis vibration value, while for vibrations on the y-axis the maximum is 10-11 m/s2, and on the maximum z-axis. at 20-21 m/s2, this analyze vibration is based on the time between 0 - 15 seconds or per 15 second interval, able to reduce percentage of vibration in the ship engine room area is 34.91%.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2022, 16, 2; 337--340
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving the accuracy of vibration measurement results
Poprawa dokładności wyników pomiarów drgań
Autorzy:
Stakhova, Anzhelika
Kvasnikov, Volodymyr
Powiązania:
https://bibliotekanauki.pl/articles/2033291.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
vibrations
measuring transducer
vibroacoustic parameter
vibration measurement
drgania
przetwornik pomiarowy
parametr wibroakustyczny
pomiar drgań
Opis:
The current state of control of vibration measuring equipment is studied in the work, the analysis of technologies of control of vibrating measuring machine equipment is carried out. It is determined that during the control a sufficient requirement for the analysis of changes in the state over time is to conduct periodic vibration measurements in the same modes of operation of the object. Therefore, the urgent task is to increase the reliability and accuracy of measurement results. It can be enhanced by obtaining additional information. For this purpose, recommendations for optimizing the vibration control points of the mechanism are formed. To increase the accuracy of measurement results when controlling the equipment for vibration signals, the methods of mounting the measuring transducer in the equipment monitoring system are considered. It is shown that the method of mounting the measuring transducer can affect the results of vibration measurements.
W pracy badany jest aktualny stan sterowania wibracyjnymi urządzeniami pomiarowymi, prowadzona jest analiza technologii sterowania wibracyjnymi urządzeniami pomiarowymi. Stwierdzono, że podczas kontroli wystarczającym wymogiem do analizy zmian stanu w czasie jest prowadzenie okresowych pomiarów drgań w tych samych trybach pracy obiektu. Dlatego pilnym zadaniem jest zwiększenie wiarygodności i dokładności wyników pomiarów. Można go ulepszyć poprzez uzyskanie dodatkowych informacji. W tym celu formułowane są zalecenia dotyczące optymalizacji punktów kontroli drgań mechanizmu. Aby zwiększyć dokładność wyników pomiarów przy sterowaniu aparaturą na sygnały wibracyjne, rozważono sposoby montażu przetwornika pomiarowego w systemie monitorowania aparatury. Wykazano, że sposób mocowania przetwornika pomiarowego może wpływać na wyniki pomiarów drgań.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2021, 11, 3; 14-17
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies