Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ventilation system" wg kryterium: Temat


Tytuł:
Designing installations in bim technology on the example of a ventilation system
Autorzy:
Gładyszewska-Fiedoruk, Katarzyna
Werner-Juszczuk, Anna Justyna
Pushchinskyi, Andrii
Powiązania:
https://bibliotekanauki.pl/chapters/31022897.pdf
Data publikacji:
2020
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
Building Information Modeling
BIM
ventilation system
Opis:
The advantages and disadvantages of the BIM design system for creating indoor installations are presented using the example of ventilation installation. In this work, one of the most effective systems has been designed for a school complex in Lviv region, Ukraine. The ventilation system was designed with the help of BIM technology in the Autodesk Revit software. After creating the 3D model of the ventilation system, aerodynamic calculations were performed and ventilation equipment selected.
Źródło:
Innovations – Sustainability – Modernity – Openness. Energy; 33-44
9788366391291
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smoke extraction garages
Autorzy:
Gładyszewska-Fiedoruk, Katarzyna
Milius, Povilas
Powiązania:
https://bibliotekanauki.pl/chapters/31020000.pdf
Data publikacji:
2019
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
ventilation system
garages
fire ventilation systems
legal requirements
smoke
smoke extraction system
Opis:
The dynamic development of motorization causes inadequate parking places in the city centers as well as in their outskirts. The emergence of new residential buildings and public utilities results in the need to create new parking spaces. Due to the problem of limited development space as well as the high cost of building plots, investors decide to create one or multi-storey closed garages. The area of these garages often reaches several tens of thousands of square meters. For these new parking spaces, an adequate and effective ventilation system should be provided, which at the same time functions as a residential ventilation system, and has a fire ventilation function as a means of protecting escape routes and rescue teams during a fire.
Źródło:
Buildings 2020+. Constructions, materials and installations; 227-246
9788365596703
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern solutions in heating systems
Autorzy:
Bilinskienė, Rūta
Krawczyk, Dorota Anna
Teleszewski, Tomasz Janusz
Rodero Serrano, Antonio
Powiązania:
https://bibliotekanauki.pl/chapters/31023945.pdf
Data publikacji:
2019
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
heating systems
heating devices
space heating
ventilation system
Opis:
A heating system is a complex system which is used to generate and transfer heat to all heating devices within a building. Heating systems should be designed in accordance with the requirements of the technological process intended for the building. The desired level of comfort and specific requirements of customers must be assessed. All components of the heating system (heating devices, piping materials, control and regulating equipment) must be chosen according to the requirements of fire safety and hygiene standards.
Źródło:
Buildings 2020+. Constructions, materials and installations; 169-197
9788365596703
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the Volumetric Expenditure of Air Supplied to the Longwall Through the “Y” Ventilation System on the Location of an Area at the Risk of an Endogenic Fire
Autorzy:
Tutak, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/2064902.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
endogenous fire
mining operation
longwall ventilation system
goaf
Opis:
In the case of longwall ventilation, in the underground hard coal mines, a phenomenon related to the migration of a certain amount of the air stream supplied to the longwall deep into goaf zones occurs. One of the wall ventilation systems, in which this phenomenon is quite intense, is the so called “Y” ventilation system. This migration is immensely unfavorable because it can lead to the self-heating process of coal left in a goaf and, consequently, to an endogenous fire. Such a fire is a great threat to both the safety and continuity of operation processes. For this reason, various activities are undertaken to prevent such a fire from occurring in goaf zones. One solution is a method presented in this article. It aims at determining an area in goaf zones, where an endogenous fire may occur. The study focused on the longwall ventilated with the Y system. This area was determined based on two criteria, namely air velocity and oxygen content. The study was carried out for various volumes of air supplied to the longwall. Therefore, the purpose of the study was to develop research methodology and determine the location of an area at the risk of an endogenous fire. The location of this area was determined for three different volume expenditures of air supplied to the longwall ventilated with the Y system.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2020, 3, 1; 206--215
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Azbest w instalacjach : wentylacyjnych oraz innych sanitarnych
Autorzy:
Małecki, Z. J.
Powiązania:
https://bibliotekanauki.pl/articles/407621.pdf
Data publikacji:
2009
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
azbest
instalacje wentylacyjne
pył azbestowy
asbestos
ventilation system
asbestos dust
Opis:
W niedalekiej przeszłości do połączeń instalacji wentylacyjnych (w innych instalacjach sanitarnych np. odpylających - przewody, kształtki) stosowane były uszczelki azbestowe lub materiały pochodne zawierające azbest. Dopuszczalne stężenie pyłu azbestu w powietrzu atmosferycznym w Polsce wynosi 1000 włókien na 1m3 powietrza w pomiarach 24-godzinnych. W następstwie drgań (wibracji) kanałów wentylacyjnych dochodzi do ścierania uszczelek znajdujących się w połączeniach zawierających azbest, a poprzez to uaktywnienie się pyłów azbestowych i transportowanych przewodami nawiewnymi do nawiewników powietrza, dostarczając je do miejsc przeznaczenia (pomieszczeń). Chorobotwórcze oddziaływanie azbestu jest wynikiem wdychania włókien zawieszonych w powietrzu. Unieszkodliwienie źródeł emisji pyłu azbestowego sprowadza się do wymiany tychże uszczelek znajdujących się w połączeniach kształtek wentylacyjnych (instalacjach sanitarnych) wraz z dezynfekcją instalacji wentylacyjnej.
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2009, 1; 22-25
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the Permeability of the Longwall Goaf Zones on the Location of an Area With Explosive Methane Concentration Levels
Autorzy:
Tutak, Magdalena
Palka, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/2064793.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
methane hazards
longwall
mining operation
longwall ventilation system
goaf
CFD
Opis:
One of the basic ventilation hazards and, at the same time most dangerous, in hard coal mines is the methane hazard. During the exploitation process using the longwall system with the breaking down of roof rocks, methane is released into mining excavations from both mined coal and the one left in goaves. Significant amounts of methane also flow from the underworked and overworked seams, through cracks and fissures formed in the rock mass. When accumulated at an explosive concentration level in goves and at an appropriate oxygen concentration level and the occurrence of a trigger (e.g. a spark or endogenous fire), methane may either explode or ignite. These are immensely dangerous phenomena. Therefore, the possibility of their occurrence should be limited. The article presents the results of the research aimed at determining the impact of the permeability of goaf zones on the distribution of methane and oxygen concentration levels in these goaves. The study was carried out for the longwall ventilated with the Y system. The model analysis was conducted, the results of which allowed the authors to determine these distributions. On their basis, both the location and size of the areas in which hazardous methane concentrations could occur were designated. The results are of great practical importance as they indicate areas in goaves where preventive measures should be implemented.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2020, 3, 1; 238--247
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie wietrzenia naturalnego w przechowalni ziemniakow
Autorzy:
Czerko, Z
Powiązania:
https://bibliotekanauki.pl/articles/835877.pdf
Data publikacji:
2002
Wydawca:
Instytut Hodowli i Aklimatyzacji Roślin
Tematy:
temperatura
przechowywanie
ziemniaki
wentylacja naturalna
systemy wentylacyjne
temperature
storage
potato
natural ventilation
ventilation system
Źródło:
Ziemniak Polski; 2002, 4; 27-31
1425-4263
Pojawia się w:
Ziemniak Polski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of transport heating systems with cascade transformers of energy
Razvitie transportnykh otopitelnykh sistem s kaskadnymi transformatorami ehnergii
Autorzy:
Starcheous, Y.
Danileychenko, A.
Lupikov, K.
Powiązania:
https://bibliotekanauki.pl/articles/793215.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heating system
ventilation system
transport
cascade transformer
generator gas
efficiency
rotor
operating condition
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2014, 14, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polskie tunele drogowe – projektowanie systemów wentylacji
Polish road tunnels – designing ventilation systems
Autorzy:
Zwolińska, Klaudia
Borowski, Marek
Powiązania:
https://bibliotekanauki.pl/articles/24024804.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
tunele drogowe
projektowanie systemu wentylacji
wentylacja wzdłużna
wentylacja poprzeczna
road tunnels
ventilation system design
longitudinal ventilation
transverse ventilation
Opis:
Tunele drogowe, choć dotychczas rzadko spotykane w polskim krajobrazie, coraz częściej pojawiają się na mapie Polski, stanowiąc interesujące i niezbędne rozwiązanie infrastrukturalne. W celu zapewnienia bezpiecznych warunków użytkowania tunelu drogowego kluczowe znaczenie ma odpowiednio zaprojektowany system wentylacji tunelu. W artykule przedstawiono analizę dostępnych rozwiązań w zakresie systemów wentylacji tuneli drogowych, ze szczególnym uwzględnieniem procesu ich projektowania i realizacji inwestycji tunelowych w polskich warunkach.
Road tunnels, although rarely found in the Polish landscape so far, appear more and more often on the map of Poland, constituting an attractive and necessary infrastructure solution. To ensure safe conditions of road tunnel operation, a properly designed tunnel ventilation system is of crucial importance. The article presents an analysis of available solutions for the ventilation systems of road tunnels, with particular emphasis on the process of their design and implementation of tunnel investments in Polish conditions.
Źródło:
Drogownictwo; 2022, 7-8; 261--270
0012-6357
Pojawia się w:
Drogownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CFD Analysis of an Innovative Wind Tower Design with Wind-Inducing Natural Ventilation Technique for Arid Climatic Conditions
Autorzy:
Obeidat, Bushra
Kamal, Hammam
Almalkawi, Amal
Powiązania:
https://bibliotekanauki.pl/articles/1839069.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wind tower
computational fluid dynamics
natural ventilation
wind pressure fluctuation
indoor air quality
passive ventilation system
Opis:
Wind towers are passive architectural elements traditionally used to ventilate buildings in the Middle East’s hot and arid regions. Some recent design initiatives in Jordan are particularly interested in using passive systems for natural ventilation. This paper focuses on an innovative wind tower design as a passive ventilation system, which will be integrated into a train station design in Aqaba, Jordan to improve the air quality in indoor spaces and reduce the cooling loads. The design uses wind-induced effects as the motivating forces to improve natural ventilation. The study optimized the wind tower and evaluated its performance using Autodesk Computational Fluid Dynamics (CFD) simulations and Grasshopper Rhino plug-ins. Airflow and distribution through the tower were analyzed using the CFD model. Grasshopper definitions were used to examine the tower efficiency in lowering the indoor air temperature. Simulations indicated the potential of the proposed wind tower to reduce the temperature by 6.164°C and supply the interior space with the required fresh air rates. This article outlines how wind towers can be used in contemporary architecture and incorporate the simulation methods to pave the way for architects to effectively validate the performance of their design proposals at the early design stage.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 86-97
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wentylacja hybrydowa - rozwiązanie przyszłości w budownictwie
Hybrid ventilation – a future solution in architectural engineering
Autorzy:
Bogdan, A.
Powiązania:
https://bibliotekanauki.pl/articles/180829.pdf
Data publikacji:
2008
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
systemy klimatyzacyjne
systemy wentylacyjne
wetylacja hybrydowa
budownictwo
air-conditioning systems
ventilation system
hybrid ventilation systems
architecture
Opis:
Obecnie stosowane systemy wentylacji i klimatyzacji są nastawione albo na zapewnienie komfortowego środowiska użytkownikom, albo na minimalizację zużycia energii przez wykorzystanie grawitacyjnego przepływu powietrza poprzez budynek. Wentylacja hybrydowa, opracowana jako połączenie najistotniejszych zalet wentylacji naturalnej i mechanicznej, jest rozwiązaniem, które jednocześnie stwarza przyjazne człowiekowi środowisko pracy i umożliwia dostosowanie działania systemu do zmiennych warunków klimatycznych, a w konsekwencji - do racjonalizacji zużycia energii na cele eksploatacji budynku. W artykule opisano możliwości zastosowania wentylacji hybrydowej, a także przedstawiono kilka wybranych przykładów budynków wyposażonych w system wentylacji hybrydowej.
Currently used ventilation and air-conditioning systems are designed either to create a comfort environment or to minimize energy consumption. Hybrid ventilation, developed to combine the advantages of natural and mechanical ventilation, is a solution which provides both a work-friendly environment and makes it possible to customize the system to variable climate conditions and, consequently, to rationalize energy consumption. This paper presents the opportunities offered by hybrid ventilation and several examples of buildings equipped with a hybrid ventilation system.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2008, 1; 10-14
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Solution to Ensure Ventilation when Expanding the Area of Cam Thanh Underground Coal Mine, Ha Long Coal Company, Vietnam
Autorzy:
Nguyen, Cao Khai
Nguyen, Van Tinh
Nguyen, Phi Hung
Nguyen, Van Quang
Powiązania:
https://bibliotekanauki.pl/articles/2020950.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
mine ventilation
mine ventilation and safety
Cam Thanh mines area
ventilation system adjustment
fan operating points
kopalnie
wentylacja
Wietnam
Opis:
In the process of underground mining, the mining system changes for various reasons. One of the main reasons is changes in the mining production plans, especially the scales and outputs. Nowadays, coal mines in Vietnam have been expanding in width and depth, and so have the mines’ ventilation systems. Consequently, there will be changes in the alteration of the structure of the design ventilation system, which reduces the effectiveness of the ventilation and does not meet the main objective of mine ventilation, directly affect the safety of the working environment in the mine. Therefore, it is necessary to research the improvement of the ventilation system with the development and specific conditions of underground coal mines in Vietnam, improving the efficiency of the ventilation work and assuring the safety of the mine environment. Cam Thanh coal mine, Ha Long coal company, Vietnam, is the case study for this research. The article considers the plan of increases the mining output by more than 1.5 times, propose solutions to improve the ventilation system accordingly, helping the company proactively implement the production plan, ensure the working environment's safety, and reduce the costs of mine ventilation.
Źródło:
Inżynieria Mineralna; 2021, 2; 533--542
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Different Types of Ventilation Systems of Munitions
Różne typy systemów wentylacyjnych amunicji
Autorzy:
Wiśniewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/403524.pdf
Data publikacji:
2017
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
ventilation system
insensitive munitions
shape memory alloy
system wentylacyjny
amunicja małowrażliwa
stopy z pamięcią kształtu
Opis:
In the article it is presented the guideline and requirements for construction and technology designing of munition, that allows mitigation and decreasing after effects of stimuli impacting the Insensitive Munition (IM), used in military equipment, i.e. in case of pressure and temperature increase during fire, fast and slow heating, sympathetic detonation, perforation of the munition by a projectile, a fragment or a shaped charge jet. The construction of the IM munition is specified with the use of barriers, ventilation/deaeration of the munition case and double-purpose technology. The features of the active and passive/inert ventilation systems of the IM munition are presented, examples of absorbing energy materials and structure of covers/barriers of a „sandwich” type. Depending on the IM classes of threats and different representative standards and one metric of munition response and technology maturity, there are different consequences of detonation, explosion, deflagration/propulsion, burn, not sustained reaction, etc. observed. Some examples are presented with the use of the shaped-memory alloys or polymers in the Insensitive Munition.
W artykule zaprezentowano wytyczne i wymagania dotyczące projektowania konstrukcji i technologii amunicji, które pozwalają złagodzić i zmniejszyć efekt bodźca uderzenia w amunicję małowrażliwą (IM) stosowaną w sprzęcie wojskowym, tj. w przypadku wzrostu ciśnienia i temperatury w czasie palenia, szybkiego i powolnego ogrzewania, przenoszenia detonacji, przebicia amunicji przez pocisk, odłamek lub strumień pocisku kumulacyjnego. W konstrukcji amunicji małowrażliwej (IM) pokazano użycie barier, wentylacji/odpowietrzenia obudowy amunicji i technologii o podwójnym zastosowaniu. Zaprezentowano cechy aktywnych i pasywnych systemów wentylacji bezwładnościowej amunicji małowrażliwej, przykłady materiałów absorbujących energię i strukturę pokryć/barier typu „kanapka”. W zależności od klasy zagrożeń amunicji małowrażliwej (IM) i różnych odpowiednich standardów dla amunicji o długości jednego metra, zaawansowania technologii, obserwuje się różne rezultaty detonacji, wybuchu, deflagracji/napędzania, palenia, niepodtrzymywania reakcji itp. Zaprezentowano przykłady użycia stopów lub polimerów z pamięcią kształtu w amunicji małowrażliwej.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2017, 8, 4 (30); 23-36
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagadnienia procesu wentylacji kabiny kombajnu rolniczego
Considerations on ventilation of combine-harvester cabin
Autorzy:
Cieślikowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/291003.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
skład granulometryczny
konimetr Zeissa
układ wentylacji kabiny
granularity
Zeiss-Conimeter
cabin ventilation system
Opis:
Niekorzystnym efektem wentylacji wymuszonej jest przenikanie cząstek zapylenia do wnętrza kabiny operatora kombajnu rolniczego. Przeprowadzone obserwacje kształtu cząstek zapylenia konimetrem Zeissa wraz z pomiarami ich wielkości wykazały udział objętościowy frakcji o wymiarach od 5 - 35µm. Stan ten wskazuje na konieczność filtrowania powietrza na wlocie do czerpni o znacznie większej skuteczności niż na obecnie stosowanym filtrze wykonanym z tkaniny syntetycznej. Analiza składu granulometrycznego pyłu odseparowanego z kanałów układu wentylacji nawiewowej kabiny wykazała zróżnicowany rozkład wielkościowy cząstek w stosunku do danych literaturowych dotyczących filtracji zapylenia drogowego.
One of the drawbacks of forced ventilation is the penetration of dust particles to the cabin of a combine-harvester. Studies of the shape of dust particles using the Zeiss-Conimeter, together with size measurements, have revealed the volume share of fraction 5 - 35µm. This indicates the need to provide far more efficient filtration of air supplied to the intake, than it is achieved in the synthetic fibre filter used nowadays. The granularity analysis of the dust separated from the intake ventilation system channels of the cabin, has revealed diversified particle distribution as opposed to reference data available on roadborne dust.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 6, 6; 85-90
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania parametrów jakości powietrza w salach dydaktycznych
Research on air quality parameters in the educational facilities
Autorzy:
Słodczyk, E.
Suszanowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/127508.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
stężenie CO2
sala dydaktyczna
regulacja
system wentylacji
carbon dioxide concentration
didactic rooms
regulation
ventilation system
Opis:
Zamieszczono wyniki badań parametrów jakości powietrza w pomieszczeniach dydaktycznych różnej wielkości. W pomieszczeniach, w których realizowany jest proces dydaktyczny z udziałem dużych grup studentów, powinien być zapewniony odpowiedni komfort klimatyczny, na który mają wpływ przede wszystkim: temperatura oraz wilgotność powietrza, jakość fizyczna i biologiczna powietrza, koncentracja CO2. W wyniku przeprowadzonych analiz wykazano, iż w pomieszczeniach dydaktycznych nie powinno się stosować wentylacji grawitacyjnej. Na podstawie przeprowadzonych badań wyznaczono współczynniki emisji CO2 przez studentów umożliwiające określenie parametrów pracy systemu wentylacji gwarantujące zapewnienie jakości powietrza w salach dydaktycznych.
Poor ventilation of didactic rooms can interfere with students’ ability to concentrate and even cause them to suffer headaches. This is a significant issue as the ventilation systems of most lecture buildings in Poland do not provide proper air exchange. This paper presents findings of research on air parameters research in the didactic rooms of various sizes. Rooms for classes should ensure climatic comfort i.e. proper humidity and air temperature, physical and biological air quality, and low concentration of carbon dioxide. The research suggested that natural ventilation should not be used, and further research was done after the upgrading of ventilation systems and installation of exhaust fans. The coefficients of carbon dioxide emissions by one student depend on the number of people and size of the room were calculated. Designated coefficients will be used in the algorithm for determining the parameters of the fans in the ventilation system of the classrooms and lecture halls.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 767-774
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies