Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "uterine activity" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
The prognostic value of electrohysterography in prediction of premature labour
Autorzy:
Sikora, J.
Matonia, A.
Horoba, K.
Ziętek, J.
Jeżewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/332889.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
elektrohisterografia
aktywność skurczowa macicy
electrohysterography
uterine activity
premature labour
Opis:
Premature birth is the leading cause of a neonatal death, so, it is extremely important to distinguish the pregnancy at risk of preterm threatening labour. The electrohysterography seems very promising as a method which enables noninvasive recording of readable bioelectrical signal of uterine muscle. The developed instrumentation enabled simultaneous recording of bioelectrical signals by means of electrodes attached to abdominal wall and mechanical activity of uterine muscle using fetal monitor. Material comprised 27 patients in physiological pregnancy (27 ÷ 40 week), and 21 patients (23 ÷ 36 week) with the symptoms of threatening premature labour. The obtained results showed that quantitative parameters of detected uterine contractions: amplitude and contraction area, obtained both for mechanical and electrical activity, were statistically significant (p < 0.05) to distinguish the patients at risk of premature labour. However, their reliability is low because they strongly depend on individual patient features. We consider the parameters characteristic for electrohysterogram exclusively e.g. contraction power and its median frequency as more useful (p < 0.05). Noninvasive electrohysterography ensures higher sensitivity and specificity for recognition of uterine contraction activity in comparison to classical mechanical method.
Źródło:
Journal of Medical Informatics & Technologies; 2008, 12; 71-76
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of automated detection of uterine contraction using tocography
Autorzy:
Horoba, K.
Wrobel, J.
Jezewski, J.
Kupka, T.
Czabanski, R.
Roj, D.
Jezewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/334025.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
uterine contractile activity
tocography
automated contraction detection
aktywność skurczowa macicy
tokografia
automatyczne wykrywanie skurczu
Opis:
Monitoring of uterine contractile activity enables to control the progress of labour. Automated detection of contractions is to be an integral part of the signal analysis implemented in computer aided fetal surveillance system. Evaluation of efficiency of three algorithms for automated detection of uterine contractions in the signal of uterine mechanical activity is presented. These algorithms are based generally on analysis of the frequency distribution of signal values. The reference data in form of beginning and end of contraction episodes were obtained from human expert. Obtained results showed high efficiency of the algorithms tested where the best one ensured the sensitivity and positive predictive value equal to 92.2 and 97.2, respectively.
Źródło:
Journal of Medical Informatics & Technologies; 2015, 24; 207-214
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of electrical uterine contractile activity for prediction of preterm delivery
Autorzy:
Horoba, K.
Jezewski, J.
Matonia, A.
Wrobel, J.
Czabanski, R.
Jezewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/333763.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
electrical uterine activity
electrohysterography
preterm delivery prediction
aktywność elektryczna macicy
elektrohisterografia
przewidywanie porodu przedwczesnego
Opis:
This study is aimed at evaluation of the capability to indicate the preterm delivery risk analysing the features extracted from signals of electrical uterine activity. Free access database was used with signals acquired in two groups of pregnant women who delivered at term and preterm. Signal features comprised classical time domain and spectral parameters of contractile activity, as well as the sample entropy. Their mean values were calculated over all contraction episodes detected in each record and their statistical significance for separating the two groups of recordings was provided. Influence of electrodes location, band-pass filter settings and gestation week was investigated. The obtained results showed that a spectral parameter – the median frequency was the most promising indicator of the preterm delivery risk.
Źródło:
Journal of Medical Informatics & Technologies; 2015, 24; 199-205
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies