Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "usuwanie węgla" wg kryterium: Temat


Wyświetlanie 1-12 z 12
Tytuł:
Optymalizacja pracy oczyszczalni ścieków w Tczewie w zakresie usuwania biogenów i związków węgla
Optimizing the performance of the Tczew wastewater treatment plant in terms of biogen and carbon compound removal
Autorzy:
Bojanowska, I.
Pepliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/237606.pdf
Data publikacji:
2002
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczalnia ścieków
optymalizacja parametrów technologicznych
technologia osadu czynnego
usuwanie biogenów
usuwanie związków węgla
Opis:
In the optimizing procedure, use was made of the data sets obtained during 2-year operation of the municipal wastewater treatment plant, as well as of those acquired in the period of technological start-up. What needed optimization was the reduction in BOD5 and the removal of nitrogen and phosphorus (biogens). The study showed that if the Clean Water Act requirements are to be met, it is necessary to keep the SS content in the effluent below 20 g/m[3]. It is also advisable to control the concentration of the activated sludge and the performance of the system for sludge aeration.
Źródło:
Ochrona Środowiska; 2002, 3; 31-36
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena usuwania związków węgla, azotu i fosforu w komunalnej oczyszczalni ścieków w Sokółce
Assessment of the removal of carbon, nitrogen and phosphorus in municipal wastewater treatment plants in Sokółka
Autorzy:
Ignatowicz, K.
Struk-Sokołowska, J.
Kazimierowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/908423.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
oczyszczanie ścieków
usuwanie węgla
usuwanie azotu
usuwanie fosforu
komunalna oczyszczalnia ścieków
wastewater treatment
carbon removal
nitrogen removal
phosphorus removal
municipal sewage treatment plant
Opis:
W sytuacji postępującej eutrofizacji wód w wielu krajach zauważalna staje się tendencja do zmiany filozofii podejścia do ich ochrony. Konieczność spełnienia obowiązujących wymagań odnośnie do jakości ścieków oczyszczonych skłania do poszukiwania sposobów intensyfikacji usuwania związków biogennych. W celu zapewnienia żądanego obniżenia stężenia związków biogennych obecnie stosowane są biologiczne metody usuwania azotu oraz biologiczne i chemiczne metody usuwania fosforu.
The aim of this study was to show changes in concentrations of organic compounds, nitrogen and phosphorus in wastewater by using activated sludge technology in sequential SBR reactors. Made of raw sewage samples, after mechanical treatment, the dephosphatation, while ¼, ½, ¾, and after complete nitrification, denitrification, and the effluent. Profiles plotted compounds of C, N and P. It has been shown that the sewage treatment plant in Sokółka and increased effects integrated removing the above-mentioned compounds.
Źródło:
Ekonomia i Środowisko; 2013, 4; 159-168
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie właściwości separacyjnych adsorbentów do procesów wydzielania ditlenku węgla ze strumieni spalin
Determination of separation properties of adsorbents for the removal of CO2 from flue gas streams
Autorzy:
Tańczyk, M.
Jaschik, M.
Warmuziński, K.
Janusz-Cygan, A.
Jaschik, J.
Powiązania:
https://bibliotekanauki.pl/articles/2071083.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
usuwanie ditlenku węgla
równowaga adsorpcji
adsorpcja zmiennociśnieniowa
carbon dioxide removal
adsorption equilibrium
pressure swing adsorption
Opis:
W pracy przedstawiono wyniki badań właściwości separacyjnych adsorbentów do procesu wydzielania CO2 ze strumieni spalin. Stwierdzono, że ZSM 13X są w tym przypadku bardziej odpowiednimi adsorbentami niż węgle aktywne. Najwyższe współczynniki selektywności oraz największe pojemności adsorpcyjne zaobserwowano w przypadku ZSM 13X Grace. Stwierdzono także, że publikowane w literaturze trójparametryczne równania izoterm adsorpcji z podobną, dobrą dokładnością opisują dane doświadczalne.
Results are presented on the separation properties of adsorbents for the removal of CO2 from flue gas streams. It is found that ZMS 13X is, for this particular task, more suitable than activated carbons. The highest selectivity and adsorption capacity were found for ZMS 13X Grace. It is also concluded that the three-parameter isotherms proposed in the relevant literature describe the experimental data with satisfactory and comparable accuracy.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 4; 82-83
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wstępne nad ograniczeniem zawartości rtęci w energetycznym węglu kamiennym poprzez zastosowanie wibracyjnego powietrznego stołu koncentracyjnego
Preliminary Studies on the Reduction of Mercury Content in Steam Coal through the Use of Air-vibrating Concentration Table
Autorzy:
Baic, I.
Blaschke, W.
Powiązania:
https://bibliotekanauki.pl/articles/1813820.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
węgiel energetyczny
sucha separacja
usuwanie rtęci z węgla
powietrzny wibracyjny stół koncentracyjny
steam coal
dry separation
removing mercury from raw coal
air-vibrating concentration table
Opis:
Zawartość rtęci w węglach kamiennych jest stosunkowo niewielka. Jednak przy dużej ilości spalanego węgla w Polsce do atmosfery przedostają się jej znaczne ilości. Rtęć występuje głównie w pirycie i markazycie wchodzących w skład substancji mineralnej węgla. Występuje także w substancji organicznej węgla. Pewne, czasami znaczne, ilości rtęci znajdują się w warstwach stropowych i spągowych pokładów węglowych, które podczas eksploatacji trafiają do urobku węglowego. Podczas wzbogacania (przeróbki mechanicznej) istnieje możliwość usuwania zanieczyszczeń skałą płonną pochodzącą z tych warstw a także z wkładek kamiennych przerastających pokłady węglowe. Możliwe jest też usuwanie uwolnionych ziarn siarczków żelaza. Jak jednak pokazuje praktyka wzbogacania metodami mokrymi (osadzarki, flotacja) procesy te są często niedokładne. W koncentratach pozostają pewne ilości skały płonnej i związków siarki. Skutkuje to przechodzeniem do produktów handlowych związków rtęci. W Instytucie Mechanizacji Budownictwa i Górnictwa Skalnego w Oddziale Katowickim prowadzone są od kilku lat badania nad odkamienianiem urobku węglowego metodą suchą. Wykorzystuje się posiadaną instalację wyposażoną w wibracyjny powietrzny stół koncentracyjny. Urządzenie to, przy dobrym uregulowaniu, pozwala na skuteczne usuwanie wspomnianych zanieczyszczeń. Istnieje więc możliwość aby oprócz odkamieniania urobku usuwać związki rtęci, które znajdują się we frakcjach o dużej gęstości. W niniejszym artykule omówiono źródła i wielkości emisji rtęci, jej zawartość w węglach kamiennych oraz uwarunkowania prawne dotyczące emisji rtęci. Przedstawiono też wstępne wyniki badań nad możliwościami usuwania rtęci przy wykorzystaniu wibracyjnego powietrznego stołu koncentracyjnego.
Mercury content in hard coal is relatively small. However, when a large amount of coal is burned in Poland, the considerable quantities of mercury reach the atmosphere. The mercury is mainly pyrite and marcasite included in mineral coal substance. It is also present in the organic carbon substance. Certain, sometimes substantial quantities of mercury are found in the roof and bottom layers of coal field which during the exploitation reach the run-of-mine. During the enrichment (mechanical processing) it is possible to remove impurities with a gangue coming from these layers and from inserts of stone outstripping coal seams. It is also possible to remove the released iron sulphide particles. But, as practice shows wet enrichment methods (jigging, flotation) are often inaccurate. The concentrates contain certain amounts of gangue and sulphur compounds. This results in a transition to commercial products of mercury compounds. The Institute of Mechanized Construction and Rock Mining, a Branch in Katowice conducts for several years the research on the deshaling method of dry run-of-mine. It uses possessed installation equipped with air-vibrating concentration table. This device, with good regulation, allows effective removal of these contaminants. There is therefore the possibility of deshaling the excavated material and in addition removing mercury compounds that are found in the fractions with a high density. This article discusses the sources and emissions of mercury, its content in hard coal and legal considerations regarding mercury emissions. Also presented are the preliminary results of research activities on mercury removal using a air-vibrating concentration table.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 480-496
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie chromu (VI) na węglu aktywnym regenerowanym węglanem sodu
Chromium (VI) desorption on activated carbon regenerated with sodium carbonate
Autorzy:
Lach, J.
Dębowski, Z.
Ociepa, E.
Powiązania:
https://bibliotekanauki.pl/articles/236971.pdf
Data publikacji:
2000
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
chrom
usuwanie chromu
sorbenty węglowe
regeneracja węgla aktywnego
węglan sodu
Opis:
Investigated was the potentiality of using sodium carbonate for the regeneration of activated carbons spent in the course of chromate onion desorption. The experiments were carried out on WD-extra carbon treated with muriatic acid for partial removal of ash particles. The regeneration procedure involved sodium carbonate and was conducted in a through-flow system. The desorption and sorption effects were related to three values of Na2CO3 concentration (2,5 and 10%) and two values of flow velocity (2 and 4 m/h). The best sorption effects were achieved on carbon regenerated with the 2% Na2CO3 solution. When use was made of increased (5% or 10%) sodium carbonate concentrations, consecutive sorptions were less effective. This finding, however, cannot be explained by the amount of the desorbed chromium. The sorption effects following the regeneration procedure were found to be adversely influenced by the local increase of pH in the micropores of the activated carbon. Of importance was also the overall number of the regeneration procedures performed. Each successive procedure reduced noticeably the adsorbing capacity of the carbon with respect to chromate onion. The contribution of flow velocity to the sorption effect was less distinct. However, the flow velocity of the Na2CO3 solution contributed markedly to the duration of the regenerating procedure and to the quantity of the reagent to be used. Thus, at the flow velocity of 2 m/h, the length of regeneration increased, whereas the quantity of the sodium carbonate used decreased.
Źródło:
Ochrona Środowiska; 2000, 3; 3-6
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Investigation of Mercury Contents in Polish Coal Samples
Rtęć w polskich węglach
Autorzy:
Wichliński, M.
Kobyłecki, R.
Bis, Z.
Powiązania:
https://bibliotekanauki.pl/articles/205133.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mercury
mercury removal
coal
enrichment of coals
rtęć
usuwanie rtęci
węgle
wzbogacanie węgla
Opis:
This paper presents the results of the investigation associated with the determination of mercury content in Polish hard coal and lignite samples. Those coals are major fuels used for electricity generation in Poland. The results indicated that the average content of mercury in the coal samples was roughly about 100 ng/g. Apart from the determination of the mercury contents a detailed ultimate and proximate analysis of the coal samples was also carried out. The relationships between the mercury content and ash, as well as fixed carbon, volatile matter, sulfur, and high heating value of the coal samples were also established. Furthermore, the effect of coal enrichment was also investigated, and it was found that the enrichment process enabled the removal of up to 75% of the coal mercury from the samples.
W niniejszej pracy przedstawiono wyniki badań zawartości rtęci w polskich węglach kamiennych i brunatnych. Wyżej wymienione paliwa są głównymi paliwami używanymi do produkcji energii elektrycznej w Polsce. Wyniki wykazały, że średnia zawartość rtęci w badanych próbkach węgli wynosi około 100 ng/g. Oprócz badań zawartości rtęci przeprowadzono także analizę techniczną i elementarną próbek węgli. Zestawiono zależności pomiędzy zawartością rtęci a zawartością popiołu, fixed carbonu, części lotnych, siarki oraz ciepłem spalania. Przedstawiono także wyniki badań wpływu wzbogacania węgla na zawartość rtęci. Stwierdzono, że w wyniku procesu wzbogacania możliwe było usunięcie prawie 75% rtęci zawartej w wyjściowym paliwie.
Źródło:
Archives of Environmental Protection; 2013, 39, 2; 141-150
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania kinetyczne procesu denitryfikacji z dawkowaniem zewnętrznego źródła węgla z postaci produktów odpadowych z produkcji alkoholu
Kinetic investigations of denitrification with the addition of external carbon sources in the form of by products from alcohol production
Autorzy:
Kaszubowska, M.
Majtacz, J.
Mąkinia, J.
Czerwionka, K.
Kulbat, E.
Powiązania:
https://bibliotekanauki.pl/articles/372496.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
denitryfikacja
osad czynny
usuwanie azotu
źródła węgla
denitrification
activated sludge
nitrogen removal
carbon sources
Opis:
Celem badań była ocena możliwości zastosowania produktów odpadowych z produkcji alkoholu (olejów fuzlowych) jako alternatywnego źródła węgla w procesie denitryfikacji. Dla porównania, w badaniach wykorzystano również ścieki oczyszczone mechanicznie (bez podczyszczania oraz podczyszczone w procesie koagulacji-flokulacji), jak również dwa konwencjonalne zewnętrzne źródła węgla (kwas octowy i etanol). Badania laboratoryjne obejmowały "konwencjonalny" pomiar szybkości denitryfikacji (z ang. NUR). Pomiary wykonano wykorzystując specjalny zestaw laboratoryjny składający się z dwóch równoległych reaktorów nieprzepływowych o pojemności 4 dm3 każdy. Badane oleje fuzlowe wpływały na poprawę szybkości procesu w stopniu porównywalnym do etanolu.
The aim of this study was evaluation of the feasibility of using byproducts from alcohol production (fusel oils) as an alternative carbon source for denitrification. For comparison, the settled wastewater (without further pretreatment and after coagulation-floculation) as well as two conventional external carbon sources (ethanol and acetic acid) were also investigated. Lab experiments comprised the conventional nitrate utilization rate (NUR) measurements. The experiments were carried out in a special lab apparatus consisting of two parallel batch reactors (V = 4 dm3 each). The effect of examined fusel oils was similar to ethanol.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2011, 141 (21); 78-86
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous removal of NOx, SO2, CO and Hg from flue gas by ozonation. Pilot plant studies
Autorzy:
Głomba, M.
Kordylewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/950039.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
carbon dioxide
flue gases
ozone
ozonization
pilot plants
sulfur dioxide
gas absorption
NOx removal
So2 removal
CO removal
dwutlenek węgla
tlenki azotu
spaliny
ozon
ozonowanie
instalacje pilotażowe
dwutlenek siarki
absorpcja gazu
usuwanie NOx
usuwanie SO2
usuwanie CO
Opis:
The results of pilot plant investigations of simultaneous removal of NOx, SO2 and Hg from flue gas with ozone as the oxidizing agent and the spray tower absorber with NaOH solution as the absorbent have been presented. Flue gas was delivered into the pilot plant at the flow rate of 200 m3/h from the coal fired OP-430 boiler. The effectiveness of NOx removal was over 95% when the molar ratio O3/NO reached 2.0. Sulfur dioxide was practically completely washed out from flue gas in the absorber at the liquid-to-gas ratio 7.5 dm3/m3. The effectiveness of Hg removal in the studied system was approximately 80%. It was pointed out that CO concentration in flue gas could considerably increase the ozone consumption. The effect of carbon dioxide in flue gas on the chemistry of absorption due to hydroxides conversion into carbonates and bicarbonates was noticed.
Źródło:
Environment Protection Engineering; 2014, 40, 3; 113-125
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
In-situ treatment of groundwater contaminated with underground coal gasification products
Oczyszczanie in-situ wód podziemnych zanieczyszczonych przez produkty podziemnego zgazowania węgla
Autorzy:
Suponik, T.
Lutyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/218714.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
podziemne zgazowanie węgla (PZW)
wody podziemne
usuwanie zanieczyszczeń
bariera reaktywna
underground coal gasification (UCG)
underground water
contaminants treatment
reactive barrier
Opis:
In the paper the contaminants that may be generated in Underground Coal Gasification (UCG) process were listed and include mainly mono- and polycyclic aromatic hydrocarbons, phenols, heavy metals, cyanides, ammonium, chloride and sulphate. As a method of UCG contaminated groundwater treatment a Permeable Reactive Barrier technology was proposed. To assess the effectiveness of this technology two tests were carried out. Granulated activated carbon (GAC) and zeolite, and granulated activated carbon and scrap iron were applied in the first and second test respectively. For these materials the hydro geological parameters called reactive material parameters were determined and discussed. The results of the experiments showed that GAC seems to be the most effective material for phenols, BTX, PAH, cyanides and slightly lowers ammonia removal, while zeolites and scrap iron removed free cyanide, ammonia and heavy metals respectively.
Podziemne Zgazowanie Węgla (PZW) jest alternatywną metodą pozyskiwania energii z węgla. Jest to zespół przemian termicznych i chemicznych przebiegających bezpośrednio w złożu węgla, zachodzących pomiędzy substancją organiczną a czynnikiem zgazowującym, jakim może być powietrze, tlen, para wodna, dwutlenek węgla. Poza wieloma zaletami metoda ta niesie za sobą także wiele zagrożeń, które były rozważane w ramach projektu HUGE 2 (nr RFCR-CT-2011-00002). Jednym z nich jest zagrożenie środowiska wód podziemnych produktami PZW, do których należą wielopierścieniowe węglowodory aromatyczne, BTX, fenole, metale ciężkie, cyjanki, jony amonowe, chlorki i siarczany. W celu zminimalizowania tego zagrożenia w pracy rozważono zastosowanie w obszarze reaktora PZW technologii Przepuszczalnej Bariery Reaktywnej (PRB). W technologii tej zanieczyszczenia usuwane są in-situ poprzez przepływ wód przez odpowiednio dobrany materiał reaktywny. W tablicy 1 przedstawiono podstawowe parametry bariery, które należy określić, aby skutecznie i długotrwale chronić środowisko wodne przed zanieczyszczeniami. Jako materiał reaktywny w pracy wybrano, na podstawie zdolności oczyszczania, granulowany węgiel aktywny (do usuwania związków organicznych) oraz żelazo metaliczne i alternatywnie zeolity (do usuwaniazwiązków nieorganicznych i pozostałych związków organicznych po złożu węgla aktywnego). Badania prowadzone były w dwóch instalacjach badawczych składających się z pompy perystaltycznej oraz dwóch szeregowo połączonych szklanych kolumn filtracyjnych (rys. 1). W obu instalacjach pierwsza kolumna wypełniona była granulowanym węglem aktywnym, zaś druga odpowiednio w pierwszej i drugiej instalacji, żelazem metalicznym i zeolitami. Materiał reaktywny poza zdolnościami do usuwania zanieczyszczeń, musi również charakteryzować się długotrwałą i stabilną przepuszczalnością dla wód. Dlatego też jego skład ziarnowy dobrano w taki sposób, aby współczynnik filtracji materiału reaktywnego zawierał się między 2x10-4 i 6x10-3 m/s (co oznacza że powinien charakteryzować się maksymalnymi wartościami współczynnika filtracji dla piasku drobnoziarnistego i gruboziarnistego). Tabele 3 i 4 przedstawiają odpowiednio skład ziarnowy materiału reaktywnego zastosowanego w badaniach laboratoryjnych oraz jego główne parametry hydrogeologiczne. Zastosowany w badaniach roztwór przygotowany został poprzez zmieszanie wody destylowanej z odpowiednimi masami odczynników chemicznych, uzyskując w ten sposób stężenia zanieczyszczeń podobne do wartości przedstawionych w pracach (Kapusta & Stańczyk, 2011; Liu & in., 2006). W tabelach 5 i 6 oraz na rysunkach 2-8 przedstawiono wartości parametrów fizykochemicznych oraz stężeń substancji chemicznych zmierzonych w wodach pobranych z instalacji badawczych 1 i 2. We wnioskach pracy stwierdzono, iż granulowany węgiel aktywny jest odpowiednim materiałem do usuwania z wód fenoli, BTX, wielopierścieniowych węglowodorów aromatycznych, wolnych cyjanków oraz w mniejszym stopniu również jonów amonowych. Węgle nie wpływały na temperaturę wód oraz na potencjał redox i przewodność elektrolityczną. Zeolity z kolei skutecznie usuwały wolne cyjanki, jony amonowe oraz w pewnym stopniu fenole. W zależności od składu chemicznego wód oraz powinowactwa metali do zeolitów mogły one również usuwać metale ciężkie. Zeolity nie wpływały natomiast na temperaturę i powodowały znaczące obniżenie się wartości pH oraz przewodności elektrolitycznej wody. Przepływająca przez złoże zeolitu woda wzbogacała się z kolei (z całą pewnością w początkowym etapie pracy złoża) w rozpuszczony tlen, co miało odzwierciedlenie w wyższych wartościach potencjału redox w kolejnych punktach poboru wody. Ostatnim analizowanym w pracy materiałem było żelazo metaliczne. Chociaż nie wpływało ono w żaden sposób na stężenie związków organicznych w wodach, przyczyniło się do usunięcia z nich wszystkich metali ciężkich. Żelazo spowodowało ponadto wzrost temperatury i wartości pH oraz zdecydowane obniżenie się potencjału redox i stężenia tlenu rozpuszczonego. Rozważając zastosowanie wymienionych materiałów reaktywnych w technologii PRB do usuwania produktów PZW trzeba pamiętać o ograniczonej pojemności sorpcyjnej węgla aktywnego oraz zeolitów oraz o konieczności poddawania ich reaktywacji. Fakt ten oraz duże trudności technologiczne związane z zainstalowaniem materiału oraz jego wymianą stanowią wyzwanie do dalszych analiz i prac w tym obszarze.
Źródło:
Archives of Mining Sciences; 2013, 58, 4; 1263-1278
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja hybrydowego procesu usuwania rtęci z węgla kamiennego
A concept of the hybrid mercury removal process from hard coal
Autorzy:
Dziok, T.
Strugała, A.
Chmielniak, T.
Baic, I.
Blaschke, W.
Powiązania:
https://bibliotekanauki.pl/articles/394780.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
węgiel kamienny
rtęć
usuwanie rtęci
wzbogacanie węgla
suche odkamienianie
termiczna preparacja
hard coal
mercury
mercury removal
coal cleaning
dry deshaling
thermal pretreatment
Opis:
W powadzonych aktualnie pracach mających na celu obniżenie antropogenicznej emisji rtęci duży nacisk kładzie się na obniżenie emisji rtęci z procesów energochemicznego przetwórstwa węgla, głównie z procesów spalania. Jednym ze sposobów pozwalających na obniżenie antropogenicznej emisji rtęci jest jej usuwanie z węgla przed jego konwersją. Należy zaznaczyć, że rtęć w węglu kamiennym może być obecna zarówno w substancji organicznej jak i mineralnej, stąd też uniwersalna metoda powinna pozwalać na usuwanie rtęci z obu tych składowych substancji węglowej. W pracy przedstawiono koncepcję hybrydowego procesu usuwania rtęci z węgla kamiennego. Idea procesu polega na połączeniu procesów wzbogacania metodami mokrymi bądź suchymi (etap pierwszy) oraz wstępnej termicznej preparacji w temperaturze 200–400°C (etap drugi). W etapie pierwszym w procesie wzbogacania/ /odkamieniania z węgla usuwana jest część rtęci występującej w substancji mineralnej. Natomiast w etapie drugim z węgla usuwana jest rtęć występująca w substancji organicznej oraz rtęć w obecnych jeszcze w węglu składnikach mineralnych o relatywnie niskiej temperaturze uwalniania rtęci. Na podstawie wyników wstępnych badań, skuteczność obniżenia zawartości rtęci w węglu w takim procesie hybrydowym została oszacowana w przedziale od 36 do 75% (ze średnią wartością 58%). Efekt obniżenia zawartości rtęci w węglu jest jeszcze bardziej zauważalny w przypadku odniesienia jej zawartości do wartości opałowej węgla. Tak określona skuteczność obniżenia zawartości rtęci w węglu mieściła się w przedziale od 53 do 92% (przy średniej wartości wynoszącej 71%).
Nowadays, actions allowing for a reduction of anthropogenic mercury emission are taken worldwide. Great emphasis is placed on reducing mercury emission from the processes of energochemical coal conversion, mainly from the coal combustion processes. One of the methods which enable a reduction of anthropogenic mercury emission is the removal of mercury from coal before its conversion. It should be pointed out that mercury in hard coal may occur both in the organic and mineral matter. Therefore, a universal method should allow for the removal of mercury, combined in both ways, from coal. In the paper, a concept of the hybrid mercury removal process from hard coal was presented. The idea of the process is based on the combination of the coal cleaning process using wet or dry methods (first stage) and the thermal pretreatment process at a temperature in the range from 200 to 400°C (second stage). In the first stage, a part of mercury occurring in the mineral matter is removed. In the second stage, a part of mercury occurring in the organic matter as well as in some inorganic constituents characterized by a relatively low temperature of mercury release is removed. Based on the results of the preliminary research, the effectiveness of the decrease in mercury content in coal in the hybrid process was estimated in the range from 36 to 75% with the average at the level of 58%. The effect of the decrease in mercury content in coal is much more significant when mercury content is referred to a low heating value of coal. So determined, the effectiveness was estimated in the range from 36 to 75% with the average at the level of 58%.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2017, 98; 125-135
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estymacja kosztów wytwarzania produktów konwersji węgla
Estimation of operation and maintenance costs for coal conversion products
Autorzy:
Zapart, L.
Ściążko, M.
Dreszer, K.
Powiązania:
https://bibliotekanauki.pl/articles/282761.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
koszty wytwarzania
konwersja węgla
zgazowanie
poligeneracja
paliwa ciekłe
wodór
metanol
usuwanie CO2
transport i magazynowanie CO2
production costs
coal conversion
gasification
polygeneration
liquid fuels
hydrogen
methanol
carbon capture and storage (CCS)
Opis:
Wybór opcji technologii konwersji węgla ukierunkowanej na wytwarzanie energii elektrycznej, wodoru, metanolu oraz paliw płynnych zasadniczo musi być związany z jego zgazowaniem. W pracy przedstawiono metody oraz wyniki szacowania kosztów eksploatacji instalacji dla wybranych układów technologicznych, z uwzględnieniem kosztów usuwania, transportu i magazynowania dwutlenku węgla a także kosztów zakupu uprawnień do emisji CO2. Koszty eksploatacyjne instalacji obejmują: koszty operacyjne niepaliwowe (stałe i zmienne), koszty kapitałowe, koszty węgla, koszty transportu, składowania i monitoringu CO2. Estymacja kosztów została przeprowadzona z dokładnością jak dla studium przedrealizacyjnego (pre-feasibility), tj. š 30 %. Rachunek kosztów sporządzono dla dwóch scenariuszy: a) scenariusz 1 - przewidujący, w świetle prognozowanych zmian dotyczących praw do emisji CO2, zakup 100 % uprawnień do emisji dwutlenku węgla; b) scenariusz 2 - przewidujący budowę instalacji usuwania, transportu i składowania CO2.
Selection of coal processing technological option for power generation, hydrogen, methanol or liquid fuels production can be generally connected with coal gasification. Algorithms and capital investment cost estimations for chosen plant configurations are presented in the paper taking into account CCS costs. Production costs include: fixed and variable operating costs, capital costs, fuel costs, CO2 transport, storage and monitoring costs. The cost estimates are carried with an accuracy of š30 percent, consistent with the pre-feasibility study level. The cost estimates was prepared as with and without CO2 capture.
Źródło:
Polityka Energetyczna; 2009, T. 12, z. 2/2; 645-657
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological stability of water in water distribution systems. The effect of water treatment trials
Autorzy:
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/206902.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water treatment
carbon
groundwater
microorganisms
nitrogen removal
organic carbon
surface waters
water aeration
water distribution systems
water supply systems
biological stability
inorganic nitrogen
uzdatnianie wody
węgiel
wody gruntowe
mikroorganizmy
usuwanie azotu
węgiel organiczny
wody powierzchniowe
napowietrzanie wody
systemy dystrybucji wody
wodociągi
stabilność biologiczna
stężenie dwutlenku węgla
azot nieorganiczny
Opis:
Research into the removal efficiency of biogenic substances, necessary for the growth of heterotrophic microorganisms, was carried out for the following water treatment trials: surface water, infiltrative water and mixed surface water after microsieving with aerated underground water. The results have shown that the efficiency of removal of organic substances, independently of the type of treated water, increased along with the organic carbon concentrations in raw water. The average effectiveness of phosphate removal was: 92.1%, 88.8% and 83.7% for surface, infiltrative and mixed water, respectively. In all analyzed systems, presence of phosphates was an limiting factor for the regrowth of microorganisms in the distribution system. In none of the water treatment trials, effective removal of inorganic nitrogen has been recorded.
Źródło:
Environment Protection Engineering; 2015, 41, 2; 147-157
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies