Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "usuwanie osadu" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Experimental study on sedimentation removal of pervious concrete
Eksperymentalne badanie dotyczące usuwania betonu jamistego na drodze sedymentacji
Autorzy:
Rama, M.
Shanthi, V. M.
Powiązania:
https://bibliotekanauki.pl/articles/230935.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton jamisty
kolmatacja
usuwanie osadu
przepuszczalność
sedymentacja
woda burzowa
pervious concrete
clogging
sediments removal
permeability
sedimentation
storm water
Opis:
Pervious concrete is a unique and effective material used to tackle important environmental problems, to maintain green, sustainable growth, and to reduce storm water runoff and pollutants. Clogging of pervious concrete is an important potential issue in serviceability, considered one of the primary limitations of pervious concrete systems. The sediment deposition pattern of pervious concrete was determined using three clogging materials: clay, sand, and clayey silty sand. The clogged specimens were cleaned by pressure washing, vacuuming, and a combined method. In total, ten clogging and cleaning cycles were carried out on each sample to evaluate the draining capacity of the pervious concrete. The clogging test was assessed by measuring the infiltration rate during clogging and after cleaning, for each cycle. The experiment results showed that a reduction in permeability due to different types of sedimentation material as well as recovery in permeability was achieved after applying various cleaning methods.
Urbanizacja stwarza liczne problemy, takie jak erozja, gwałtowne powodzie, zanieczyszczenie rzek oraz efekt wyspy ciepła. Beton jamisty jest przyjaznym dla środowiska materiałem nawierzchniowym, który częściowo ogranicza wyżej wspomniane problemy, a także służy zachowaniu środowiska naturalnego, zmniejszając spływ wody burzowej, zanieczyszczenia oraz miejskie ciepło. Beton jamisty jest podobny do zwykłego betonu, z wyjątkiem dodatku drobnego kruszywa, które tworzy połączone ze sobą puste przestrzenie umożliwiające przepływ wody przez betonową matrycę. Pustki od 15% do 35% całkowitej objętości betonu jamistego są utrzymywane za pomocą gruboziarnistego kruszywa o ciągłej krzywej przesiewu i gęstego cementu, który zapobiega oddzielaniu się pasty od kruszywa. Wydajność hydrauliczna betonu jamistego dla odprowadzenia wody burzowej zależy od szybkości odkładania się osadu w odniesieniu do okresu czasu. Kolmatacja betonu jamistego stanowi istotny potencjalny problem w zakresie użytkowalności, który jest uważany za jedno z podstawowych ograniczeń w systemach betonu jamistego. Kolmatacja odnosi się do zmniejszenia przepuszczalności porowatego ośrodka ze względu na proces fizyczny, chemiczny i biologiczny. Głównymi źródłami kolmatacji są zawieszone cząstki z powierzchniowych wód spływających, a także organiczne i nieorganiczne cząstki pochodzące z ruchu drogowego i miejscowej roślinności lub pyłu wydmuchiwanego na jezdni. Niniejsze badanie koncentruje się na wydajności hydraulicznej systemu betonu jamistego poprzez wywoływanie kolmatacji przy użyciu różnych materiałów sedymentacyjnych i ocenie zdolności infiltracji betonu jamistego. Prace eksperymentalne przeprowadzono, aby zrozumieć przydatność metod renowacyjnych w przywracaniu wydajności hydraulicznej betonu jamistego. Celem tego badania jest ocena efektu kolmatacji betonu jamistego w oparciu o trzy różne materiały sedymentacyjne, trzy różne stopnie uziarnienia kruszywa i trzy metody renowacji. Służy to określeniu zmniejszenia przepuszczalności po kolmatacji i resztkowej przepuszczalności po oczyszczeniu próbek betonu jamistego.
Źródło:
Archives of Civil Engineering; 2018, 64, 1; 181-195
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja pracy oczyszczalni ścieków w Tczewie w zakresie usuwania biogenów i związków węgla
Optimizing the performance of the Tczew wastewater treatment plant in terms of biogen and carbon compound removal
Autorzy:
Bojanowska, I.
Pepliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/237606.pdf
Data publikacji:
2002
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczalnia ścieków
optymalizacja parametrów technologicznych
technologia osadu czynnego
usuwanie biogenów
usuwanie związków węgla
Opis:
In the optimizing procedure, use was made of the data sets obtained during 2-year operation of the municipal wastewater treatment plant, as well as of those acquired in the period of technological start-up. What needed optimization was the reduction in BOD5 and the removal of nitrogen and phosphorus (biogens). The study showed that if the Clean Water Act requirements are to be met, it is necessary to keep the SS content in the effluent below 20 g/m[3]. It is also advisable to control the concentration of the activated sludge and the performance of the system for sludge aeration.
Źródło:
Ochrona Środowiska; 2002, 3; 31-36
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generowanie lotnych kwasów tłuszczowych ze strumienia ścieków surowych oraz niektóre problemy ścieków dowożonych taborem asenizacyjnym
Generation of volatile fatty acids from the stream of raw sewage and some problems of sewage brought by sewage removal rolling stock
Autorzy:
Malej, J.
Powiązania:
https://bibliotekanauki.pl/articles/1826292.pdf
Data publikacji:
2001
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
lotne kwasy tłuszczowe
ścieki surowe
proces denitryfikacji
usuwanie fosforu
fermentacja osadu
Opis:
Podstawy technologiczne generowania lotnych kwasów tłuszczowych. Kluczową rolę w określaniu sprawności procesów denitryfikacji oraz skuteczności usuwania fosforu metodami mikrobiologicznymi ogrywają łatwo przyswajalne związki a zwłaszcza lotne kwasy tłuszczowe i ich sole [1]. W wysokosprawnych oczyszczalniach ścieków projektowane są różne schematy rozwiązań technicznych fermentacji kwaśnej z wykorzystaniem osadów wstępnych przedstawione na rys. 1 [2]: osadnik wstępny z recyrkulacją osadów, osadnik wstępny z płukaniem osadów, fermenter z pełnym wymieszaniem, jednostopniowy fermenter - zagęszczacz, dwustopniowy fermenter - zagęszczacz o pełnym wymieszaniu. Prowadzone są badania mające na celu generowanie lotnych kwasów tłuszczowych z zastosowaniem termofilowej fermentacji osadu - przy minimalnym stężeniu tlenu rozpuszczonego. Proces okazał się bardzo wydajny (3500÷4000 mg LKT/dm3), przy potencjale redox -200 mV i czasie zatrzymania hydraulicznego do 24 godzin. Według literatury źródłowej [3] lotne kwasy tłuszczowe (organiczne) stanowią 3,5÷6,4% suchej masy osadów wstępnych. Na uwagę zasługuje fakt, że LKT nie stwierdza się w świeżym osadzie czynnym, gdyż kwasy organiczne jako substrat łatwo przyswajalny ulegają szybko wykorzystaniu w przemianach biochemicznych. O uaktywnieniu się określonej grupy enzymów - regulujących przemiany biochemiczne - decyduje potencjał oksydo redukcyjny na powierzchni błony komórkowej. Potencjał ten może się znacznie różnić od potencjału mierzonego w środowisku oczyszczanych ścieków. Podczas biologicznego oczyszczania ścieków potencjał redox zwykle nie osiąga stanu równowagi ponieważ w reaktorach - np. w komorach osadu czynnego - zachodzą reakcje oksydacyjne i redukcyjne. Przykładowo w kłaczce osadu czynnego może zachodzić proces nitryfikacji i denitryfikacji. Podczas oddychania beztlenowego elektrony [ ] i protony [H+] są przenoszone na związki mineralne lub organiczne. W przypadku gdy akceptorami elektronów i protonów są związki organiczne, to proces ten określa się jako fermentacja, którą charakteryzuje określony zakres potencjału redox od 0 do -350 mV. Niższe wartości potencjału charakteryzują proces metanogenezy. Rozwój mikroorganizmów wytwarzających metan następuje przy bardzo niskim potencjale w granicach od -350 do - 500 mV [1]. W literaturze podkreśla się, że sztuka eksploatacji fermenterów (służących do generowania LKT) polega na zatrzymaniu procesu fermentacji przed rozpoczęciem się metanogenezy, to znaczy utrzymanie zakresu utrzymanie zakresu potencjału redox powyżej -350 mV [2]. Praktycznie dokonuje się tego przez okresowe napowietrzanie. Intensywność napowietrzania powinna być zsynchronizowana z miernikiem potencjału redox - w układzie S/R, aby nie dopuścić do rozpoczęcia procesu utleniania związków organicznych w tym również LKT, charakteryzującego wysoką wartość dodatnią potencjału redox od +100 do +300 mV.
This paper presents technological basics of volatile fatty acids generation as well as results of the research which aim was: determination of VFA generation effectiveness in the raw sewage: without suspension - after two hour sedimentation in the Imhoff funnel with suspension, under different temperature conditions, by different incubation time. Research was carried out in three stages: 1st stage 15 November ÷ 3 December, 1999 - autumn, 2nd stage 10 January ÷ 27 January, 2000 - winter, 3rd stage 4 April ÷ 13 April, 2000 - spring, Incubation of the sewage sampled before screen was carried out in different temperature ranges and during different time: 1st stage, incubation time - 5 days, average temperatures 8÷20÷30°C, 2nd stage, incubation time - 14 days, average temperatures 8÷20÷30°C, 3rd stage, incubation time - 8 days, average temperature 20°C. For the comparative aims VFA content was determined on the fresh sewage sampled before screen as well as in the sewage brought to the sewage treatment plant by rolling stock. Results of the carried out research allow drawing following conclusions: Carried out research proved possibility of volatile fatty acids (VFA) generation from the stream of raw sewage. High average values of VFA were determined during all three stages, at lower temperatures of sewage incubation (t1 = 8°C average) as well as at higher temperatures (t2 = 20°C average). High negative values of redox potential were determined. Such values of redox potential characterize acid fermentation process, during which volatile fatty acids are generated. Comparatively high and variable concentration of VFA was obtained, using different incubation times (5, 8 and 14 days) as well as different average temperatures (8, 20 and 30°C). This finds confirmation, that in incubated sewage ensued process of acid fermentation. In comparison with results of raw sewage analysis, in which low concentrations of VFA and also low values of redox potential were determined, were 3.5-times lower in comparison with incubated sewage. During all three stages of measurements average and maximal values of VFA concentration were determined, at lower as well as higher incubation temperatures (t1 = 8°C and t2 = 20°C). Significantly lower concentration of VFA was determined in the incubated sewage at the highest temperature (t3 = 30°C). It may be presumed that high temperatures were conductive to development of heterotrophic bacteria, which are using easily available carbon compounds, especially volatile fatty acids and their salts. No significant influence of suspension removal - before incubation - on determined concentrations of VFA was noted.
Źródło:
Rocznik Ochrona Środowiska; 2001, Tom 3; 103-128
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological nutrient removal using a novel five-step continuous flow activated sludge process technology
Autorzy:
Abualhai, S.
Naseer, R.
Xiwu, L.
Powiązania:
https://bibliotekanauki.pl/articles/208183.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
nitrogen removal
activated sludge process
chemical oxygen demand
sewage
nutrient removal
biological processes
nutrient concentrations
usuwanie azotu
chemiczne zapotrzebowanie tlenu
ścieki
biologiczne usuwanie składników odżywczych
proces biologiczny
stężenie substancji odżywczych
metoda osadu czynnego
proces osadu czynnego
Opis:
An anaerobic-anoxic/oxic (AA/O) five-tank biological process called five-step continuous flow activated sludge process (FSCFASP) was developed to force the oscillation of organic matter and nutrient concentrations in process reactors. The run scheme and schematic diagram of FSCFASP was described. The run cycle was divided into two symmetrical half cycles with eight periods during each cycle. The duration of each period was established according to biological process requirements. The optimal running times of the periods were 90, 60, 60, 30, 90, 60,6 0 and 30 min at the HRT of 16 h, air/water ratio of 35% and SRT of 21 day at the temperature range of 19-23 °C. The optimized system achieved 88.09±1.43%, 90.33±2.9%, 68.83±5.34% and 87.67±2.9% of the chemical oxygen demand, NH4+-N, TN, and TP removal efficiencies, respectively, during a 11-month operation with the effluent meeting the Chinese sewage discharge standard GB18918-2002 (level A). Simultaneous nitrification and denitrification phenomena were observed in the tank one which is important to reduce the quantity of aeration and the duration of a next anoxic state. Compared with other existing technologies, this system achieved high nitrogen and phosphorus removal without equipment of sludge and mixed liquor return. Thus, it is effective for reducing energy consumption.
Źródło:
Environment Protection Engineering; 2013, 39, 3; 165-184
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Start-up, modelling and simulation of the anammox process in a membrane bioreactor
Autorzy:
Cema, G.
Sochacki, A.
Kubiatowicz, J.
Gutwiński, P.
Surmacz-Górska, J.
Powiązania:
https://bibliotekanauki.pl/articles/185149.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
activate sludge model
anammox
computer simulation
modeling
nitrogen removal
aktywowane modelu osadu
symulacja komputerowa
modelowanie
usuwanie azotu
Opis:
There are certain well-known methods of diminishing concentrations of nitrogen compounds, but they are ineffective in case of nitrogen-rich wastewater with a low content of biodegradable carbon. Partial nitritation followed by anaerobic ammonium oxidation (Anammox) process appear to be an excellent alternative for traditional nitrification and denitrification. This paper presents the feasibility of successful start-up of Anammox process in a laboratory-scale membrane bioreactor (MBR). It was shown that the combination of membrane technology and Anammox process allowed to create a new highly efficient and compact system for nitrogen removal. It was possible to achieve average nitrogen removal efficiency equal to 76.7 +/-8.3%. It was shown that the start-up period of 6 months was needed to obtain high nitrogen removal efficiency. The applied biochemical model of the Anammox process was based on the state-of-the-art Activated Sludge Model No.1 (ASM 1) which was modified for accounting activity of autotrophs (nitrite-oxidising bacteria and nitrateoxidising bacteria) and anammox bacteria. In order to increase the predictive power of the simulation selected parameters of the model were adjusted during model calibration. Readjustment of the model parameters based on the critically evaluated data of the reactor resulted in a satisfactory match between the model predictions and the actual observations.
Źródło:
Chemical and Process Engineering; 2012, 33, 4; 639-650
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania przydatności alkalicznych materiałów filtracyjnych do usuwania fosforanów z biologicznie oczyszczonych ścieków bytowych
Suitability studies of alkaline filtration materials for phosphates removal from biologically treated domestic sewage
Autorzy:
Jucherski, A.
Nastawny, M.
Walczowski, A.
Jóźwiakowski, K.
Gajewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/237598.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
domestic sewage
sewage treatment
filtration
alkaline bed
phosphorus removal
precipitation
ścieki bytowe
oczyszczanie ścieków
filtracja
złoże alkaliczne
usuwanie fosforu
wytrącanie osadu
Opis:
Three different alkaline filtration materials were selected for orthophosphates(V) removal from biologically treated domestic sewage. As early as 35 weeks after starting filter operation one of the materials with typical granular limestone characteristics (calcium content of about 50%) was excluded from the test due to high bed clogging that inhibited its further exploitation. Tests of the two other materials with substantially lower calcium content continued uninterrupted throughout the 96-week research period. An average efficacy of phosphates removal for both materials was 80–90% at filtration rate of 0.6 m/d and 50–55% – at the rate of 1.2 m/d. Phosphates removal from sewage with the alkaline filter beds resulted from chemical precipitation of apatite deposits on the surface of filter material grains. However, such filtration materials could be applied to removal of phosphates (e.g. in household sewage treatment systems) provided that the sewage pH in the filter effluent did not exceed 8.5.
Do usuwania ortofosforanów(V) z biologicznie oczyszczonych ścieków bytowych zastosowano trzy materiały filtracyjne o charakterze alkalicznym. Jeden z tych materiałów, o cechach typowego granulatu wapiennego (zawartość wapnia około 50%), został wyłączony z badań już po 35 tygodniach eksploatacji filtru, ponieważ powodował silną kolmatację złoża, uniemożliwiającą jego dalszą eksploatację. Badania dwóch pozostałych materiałów, zawierających mniejszą ilość wapnia (15–20%), prowadzono bez zakłóceń przez 96 tygodni. Średnia skuteczność usuwania fosforanów z użyciem obu tych materiałów przy prędkości filtracji 0,6 m/d wynosiła 80÷90%, natomiast przy prędkości filtracji 1,2 m/d odpowiednio 50÷55%. Usuwanie fosforanów ze ścieków na alkalicznych złożach filtracyjnych było efektem ich chemicznego strącania w postaci apatytów na powierzchni ziaren złóż. Jednakże takie materiały filtracyjne mogą być stosowane do usuwania fosforanów (np. w przydomowych oczyszczalniach ścieków) pod warunkiem, że wartość pH ścieków w odpływie z filtru nie wzrośnie powyżej 8,5.
Źródło:
Ochrona Środowiska; 2017, 39, 1; 33-38
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of carbon and nitrogen compounds removal from domestic wastewater in a modernized biological reactor
Autorzy:
Makowska, M.
Jadanowski, S.
Tränckner, J.
Powiązania:
https://bibliotekanauki.pl/articles/207574.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biological reactor
domestic wastewater
activated sludge process
hybrid technology
removal nitrogen
reaktor biologiczny
ścieki domowe
proces osadu czynnego
proces hybrydowy
usuwanie azotu
Opis:
Upgrading concepts for the Bioblok MU200a wastewater treatment plant have been presented. The main goals were to achieve an effective nitrogen removal and reduce energy demand. The reference version has been presented, followed by two retrofitting options: introduction of intermittent aeration for alternating aerobic and anoxic conditions, additionally including a retrofitting option to a hybrid technology that combines advantages of activated sludge and biofilm. To design and assess both variants, the ASM3 model was used, running on the Simba# simulator. A rather complex biofilm model, necessary for the hybrid concept, was bypassed by installing a separate activated sludge process differing in terms of sludge age and disposal of its excess sludge to the reactor. In this way, favorable technological parameters for efficient wastewater treatment could be assessed. Both upgrading concepts can be recommended for their satisfactory treatment effectiveness, feasibility in existing plants and considerable energy savings. The significance of the modelled effects was statistically confirmed two-tailed Student’s t-test.
Źródło:
Environment Protection Engineering; 2018, 44, 4; 69-83
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies