Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ultrasound method" wg kryterium: Temat


Wyświetlanie 1-11 z 11
Tytuł:
Light extinction and ultrasound method in the identification of liquid mass fraction content in wet steam
Autorzy:
Majkut, Mirosław
Dykas, Sławomir
Smołka, Krystian
Powiązania:
https://bibliotekanauki.pl/articles/1845458.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wet steam
light extinction
ultrasound method
mass fraction content
Opis:
Recently, significant progress has been made in experimental studies on the flow of wet steam, measuring techniques based on recording the phenomenon of extinction of light and ultrasound have been elaborated or improved. The basic value experimentally determined in the final stage was the content of the liquid phase defined as the wetness fraction. The methodology of tests and experimental investigations was presented, as well as the applied and developed measurement systems. Next, some developed designs of new ultrasonic and light extinction measuring probe and their modifications are described. The article presents also some examples of applications of the developed measurement techniques in application to experimental research conducted on wet steam. Examples of comparison between experimental and numerical tests for the extinction method are also provided.
Źródło:
Archives of Thermodynamics; 2020, 41, 4; 63-92
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Light extinction and ultrasound method in the identification of liquid mass fraction content in wet steam
Autorzy:
Majkut, Mirosław
Dykas, Sławomir
Smołka, Krystian
Powiązania:
https://bibliotekanauki.pl/articles/1845452.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wet steam
light extinction
ultrasound method
mass fraction content
Opis:
Recently, significant progress has been made in experimental studies on the flow of wet steam, measuring techniques based on recording the phenomenon of extinction of light and ultrasound have been elaborated or improved. The basic value experimentally determined in the final stage was the content of the liquid phase defined as the wetness fraction. The methodology of tests and experimental investigations was presented, as well as the applied and developed measurement systems. Next, some developed designs of new ultrasonic and light extinction measuring probe and their modifications are described. The article presents also some examples of applications of the developed measurement techniques in application to experimental research conducted on wet steam. Examples of comparison between experimental and numerical tests for the extinction method are also provided.
Źródło:
Archives of Thermodynamics; 2020, 41, 4; 63-92
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nieniszczące wykorzystywane w praktyce budowlanej
Non-destructive tests used in civil engineering
Autorzy:
Drobiec, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/107798.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
badania niszczące
metoda sklerometryczna
metoda elektromagnetyczna
metoda ultradźwiękowa
metoda młoteczkowa
destructive testing
sclerometric method
electromagnetic method
ultrasound method
acoustics method
Opis:
Badania nieniszczące coraz częściej wykorzystuje się podczas wznoszenia oraz adaptacji obiektów istniejących. Oprócz metod znanych od dawna (np. metoda sklerometryczna) stosuje się obecnie metody młoteczkowe, radarowe, elektromagnetyczne, oraz prowadzi się badania mieszanek betonowych. W pracy omówiono podstawowe metody nieniszczące stasowane pzy analizę istniejących obiektów w kraju. Przedstawiono możliwości urządzeń diagnostycznych dostępnych na rynku. Zaprezentowano wyniki badań prowadzonych przy pomocy różnych metod i urządzeń.
Non-destructive testing is increasingly used in the construction and adaptation of existing buildings. In addition to methods that have been known for a long time (eg the sclerometric method), we currently use acoustics, radar, electromagnetic methods, and research on concrete mixes. The work discusses the basic non-destructive methods placed on buildings in Poland. The possibilities of diagnostic devices available on the market are presented. The results of research conducted using various methods and devices are presented.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 3; 76-80
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability and quality of ultrasound measurements of fetal heart rate variability
Autorzy:
Jeżewski, J.
Wróbel, J.
Kupka, T.
Matonia, A.
Horoba, K.
Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/334011.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
zmienność tętna płodu
USG metodą Dopplera
EKG płodu
fetal heart rate variability
Doppler ultrasound method
fetal electrocardiogram
Opis:
This work was aimed at assessment of usability of Doppler ultrasound method for the analysis of fetal heart rate variability at a level of single heart beats. The purpose of this study was to check if today fetal monitors provide the signal of accuracy comparable with an electrocardiography method. The virtual instrumentation software for measurement system and processing of acquired signals was implemented using LABVIEW environment. The results obtained reveal that accuracy of today monitors which use Doppler ultrasound technique is sufficient for visual analysis of the FHR traces. However, for the computerized analysis at a beat-to-beat level, this accuracy is below the acceptable value.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT21-26
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of the adherence of mortars using ultrasound
Autorzy:
Khaldi, Nacera
Belachia, Mouloud
Benouis, Abdelhalim
Powiązania:
https://bibliotekanauki.pl/articles/396136.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
adherence of mortars
mortar
support
adhesion
thickness
ultrasound method
pull out
przyczepność zaprawy
zaprawa
ocena przyczepności
metoda ultradźwiękowa
ultradźwięki
Opis:
Mortars are subjected to severe external stresses such as freezing, thawing, and drying during their lifetime. These stresses can lead to a loss of adhesion between the support and the mortar. The strength of the substrates with respect to their ability to receive a coating (mortar) is characterized in particular by the value of minimum tear resistance of the surface to be coated. In this work, the use of a non-destructive method which is both fast and easy to implement is employed to evaluate this support-mortar adhesion. The first method is based on the measurement of the velocities of the surface ultrasonic waves and the second by tearing tests using a specific dynamometer. The determination of the adhesion strength concerned two different supports (concrete beam and masonry block) coated with two types of mortar (a prepared cement mortar and a ready-to-use mortar) with two different thicknesses for each mortar (1 and 2 cm, respectively). The results of the two methods are then correlated for an estimation of the adhesion of the mortars.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 2; 185-199
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling Breast Ultrasound; on the Applicability of Commonly Made Approximations
Autorzy:
Taskin, U.
Ozmen, N.
Gemmeke, H.
van Dongen, K. W. A.
Powiązania:
https://bibliotekanauki.pl/articles/176654.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
breast ultrasound
forward modeling
full-wave method
Opis:
To design breast ultrasound scanning systems or to test new imaging methods, various computer models are used to simulate the acoustic wave field propagation through a breast. The computer models vary in complexity depending on the applied approximations. The objective of this paper is to investigate how the applied approximations affect the resulting wave field. In particular, we investigate the importance of taking three-dimensional (3-D) spatial variations in the compressibility, volume density of mass, and attenuation into account. In addition, we compare four 3-D solution methods: a full-wave method, a Born approximation method, a parabolic approximation method, and a ray-based method. Results show that, for frequencies below 1 MHz, the amplitude of the fields scattering off the compressibility or density contrasts are at least 24 dB higher than the amplitude of the fields scattering off the attenuation contrasts. The results also show that considering only speed of sound as a contrast is a valid approximation. In addition, it is shown that the pressure field modeled with the full-wave method is more accurate than the fields modeled using the other three methods. Finally, the accuracy of the full-wave method is location independent whereas the accuracy of the other methods strongly depends on the point of observation.
Źródło:
Archives of Acoustics; 2018, 43, 3; 425-435
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasound assisted extraction for determination of mobile fractions of copper in soil
Autorzy:
Lesniewska, B.
Swierad, E.
Lukowski, A.
Wiater, J.
Godlewska-Zylkiewicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/874478.pdf
Data publikacji:
2014
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
soil
copper fraction
determination
ultrasound detector
BCR method
electrothermal atomic absorption spectrometry
Opis:
Background. For evaluation of the mobility of metals present in soil various approaches based on sequential extraction procedures (Tessier’s, BCR or modified BCR) have been proposed, but they are very laborious and time-consuming. Objective. The aim of this study was to develop a new fast extraction procedure for the determination of mobile fractions of copper in soil. Material and methods. The samples of soil that vary in terms of physicochemical properties and certified reference material (BCR-701) were used in this study. The three-stage modified BCR procedure used for fractionation of copper in soil was accelerated by ultrasound irradiation using an ultrasonic probe. The content of copper in soil extracts was determined by electrothermal atomic absorption spectrometry (ETAAS). Results. The extraction conditions for separation of mobile fractions of copper from soil with the use of ultrasonic probe were optimized. The working parameters of the probe were as follows: the power was 15 W for all fractions while the sonication time was 7 min, 10 min and 6 min for fraction I, fraction II and fraction III, respectively. The developed procedure was validated; linearity of calibration graphs, limit of detection and limit of quantification, accuracy and repeatability of the procedure were evaluated. The content of copper in fraction I-III in soil samples collected from Podlaskie Voivodeship was at the level of 0.09-1.92 mg·kg-1, whereas its pseudo-total content was in the range 2.75-9.75 mg·kg-1. Conclusions. The developed ultrasound assisted sequential extraction procedure allowed for shortening the total extraction time from 48 h to 27 minutes in comparison to conventional modified BCR procedure. The studied soil contains a low pool of copper bioavailable to plants because a sum of mobile fractions (FI-FIII) represents only 22-46% of its pseudo-total content.
Wprowadzenie. Ocena zawartości mobilnych form metali w glebie najczęściej prowadzona jest z wykorzystaniem praco- i czasochłonnych procedur ekstrakcji sekwencyjnej wg Tessiera, BCR oraz zmodyfikowanej procedury BCR. Cel badań. Opracowanie nowej szybkiej procedury ekstrakcji sekwencyjnej wspomaganej ultradźwiękami do oznaczania mobilnych frakcji miedzi w glebie. Materiały i metody. Badania prowadzono wykorzystując próbki gleb różniące się właściwościami fizykochemicznymi oraz certyfikowany materiał odniesienia (BCR-701). Trójetapowa zmodyfikowana procedura BCR zastosowana do frakcjonowania miedzi w glebie została przyspieszona przez wykorzystanie ultradźwięków. Do oznaczania analitu w otrzymanych ekstraktach zastosowano technikę atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS). Wyniki. W pracy zoptymalizowano warunki ekstrakcji mobilnych frakcji miedzi z gleby z wykorzystaniem sondy ultradźwiękowej. Jako optymalne warunki pracy sondy ultradźwiękowej przyjęto: moc sondy 15 W dla wszystkich frakcji oraz czas 7 min dla Frakcji I, 10 min dla Frakcji II i 6 min dla Frakcji III. Opracowaną procedurę zwalidowano wyznaczając: linowość, granice wykrywalności i oznaczalności, dokładność i powtarzalność wyników. Zawartość miedzi we frakcjach I-III wyekstrahowanych z gleb pobranych z terenu województwa podlaskiego była na poziomie 0,09-1,92 mg·kg-1, natomiast jej całkowita zawartość wynosiła od 2,75 do 9,75 mg·kg-1. Wnioski. Opracowana procedura ekstrakcji sekwencyjnej wspomaganej ultradźwiękami pozwala na skrócenie czasu ekstrakcji mobilnych frakcji miedzi z 48 godzin do 27 minut w stosunku do tradycyjnej zmodyfikowanej procedury BCR. Badane gleby zawierają niewiele miedzi biodostępnej dla roślin, a suma mobilnych frakcji miedzi (frakcje I-III) stanowi tylko od 22 do 46% jej całkowitej zawartości.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2014, 65, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advantages of the Total Focusing Method
Zalety metody pełnego ogniskowania TFM
Autorzy:
Reverdy, Frédéric
Benoist, Gregoire
Powiązania:
https://bibliotekanauki.pl/articles/107917.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Total Focusing Method
ultrasound testing
nondestructive testing
metoda pełnego ogniskowania (TFM)
badania ultradźwiękowe
badania nieniszczące
Opis:
Total Focusing Method has been recently made available in portable Phased-Array Ultrasonic Instrument. Portable industrial equipment with full-parallel capabilities allows handling of matrix-array probes, 3D imaging and advanced techniques for optimal focusing. Total Focusing Method, a reconstruction based technique, is discussed: it allows better sizing of the defects during inspections, a clear detection of small defects and defect characterization. Moreover, real-time adaptive inspection associated to Total Focusing Method has been implemented to take into account the variability of the examination surface.
Metoda pełnego ogniskowania TFM (ang. Total Focusing Method) została niedawno udostępniona w przenośnym urządzeniu ultradźwiękowym z technologią phased-array. Przenośne urządzenia przemysłowe stwarzają możliwość nadzorowania równoległego pracy przetworników macierzowych, obrazowania 3D i zaawansowanych technik optymalnego ogniskowania. W pracy omówiono metodę TFM bazującą na technice rekonstrukcji. Pozwala ona na lepsze określenie rozmiarów wad podczas inspekcji, wyraźne wykrycie drobnych wad i ich charakterystykę. Ponadto przedstawiono wdrożenie kontroli adaptacyjnej w czasie rzeczywistym związanej z metodą TFM, uwzględniającej zmienność badanej powierzchni.
Źródło:
Badania Nieniszczące i Diagnostyka; 2019, 4; 4-7
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bench life (work time) of moulding and core sands with chemical binders – a new, ultrasound investigation method
Autorzy:
Zych, J.
Powiązania:
https://bibliotekanauki.pl/articles/381341.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bench life
ultrasound
binding sand
moulding sand
investigation method
ultradźwięk
materiał wiążący
masa formierska
metoda badawcza
Opis:
The obtained results of the investigations of influences of the selected technological factors on the bench life (work time) of moulding and core sands with chemical binders are presented in the hereby paper. The bench life assessment is performed by the new, author’s method with the application of the ultrasound technique. This method was patented by the author. The influence of such factors as: matrix (surroundings) temperature, matrix water content, ratio of binding components hardener/binder (h/b) and the reclamation – on the bench life of furan moulding sands was determined. The empirical dependencies (regressions) were determined, which allowed forecasting the bench life (BL) of moulding sands as functions: BL = f(W%), BL = f(T) for the fresh and after the reclamation sands, BL = f(h/b). These dependencies should be treated as examples of the new method application for investigating the bench life of moulding sands with chemical binders.
Źródło:
Archives of Foundry Engineering; 2013, 13, 4; 117-122
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method of precise pulse onset determination using the Akaike Information Criterion for Ultrasound Transmission Tomography
Autorzy:
Pruchnicki, Piotr
Opieliński, Krzysztof J.
Powiązania:
https://bibliotekanauki.pl/articles/2146650.pdf
Data publikacji:
2021
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
Akaike Information Criterion
AIC
pulse wave
transmission method
ultrasound tomography
kryterium informacyjne Akaike
fala tętna
metoda transmisyjna
tomografia ultradźwiękowa
Opis:
Information criteria used in statistics for model selection can be used to accurately determine pulse transition times in transmission methods. The most popular information criteria are the Akaike Information Criterion (AIC) and the Bayesian Schwartz Criterion (BIC). These criteria are considered the most reliable tests of model type and structure and are computationally simple. In this paper, an algorithm developed according to the AIC criterion is used to determine the transition time from transmission tomography measurements acquired with a multi-element ultrasonic ring array, which is the scanning element of the novel prototype of ultrasound tomography device for detecting and estimating the malignancy of female breast cancer in vivo. As a result, a new algorithm was developed to precise search for the onset of the recorded receiving pulse. The algorithm was tested in an aqueous environment using elementary pairs of transmitting and receiving ultrasonic transducers of a tomographic ring array.
Źródło:
Vibrations in Physical Systems; 2021, 32, 1; art. no. 2021115
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel imaging techniques for defects characterisation in Phased Array inspection
Nowe techniki obrazowania dla charakteryzacji wad w badaniach Phased Array
Autorzy:
Rioux, P.
Lachance, F.
Giguère, D.
Turcotte, J.
Powiązania:
https://bibliotekanauki.pl/articles/107792.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ultrasound testing (UT)
phased array (PA)
sizing
full matrix capture (FMC)
Total Focusing Method (TFM)
badanie ultradźwiękowe (UT)
wymiarowanie
pełne przechwytywanie macierzy (FMC)
metoda pełnego ogniskowania (TFM)
Opis:
Phased Array ultrasonic testing has demonstrated over the years that it has many advantages compared to conventional techniques: fast, reliable, with higher resolution and sensitivity. While it took time to catch up in the field, it is now widely considered as the go-to technique for complex inspections. At the same time, technology has continued to evolve, thus increasing the possibilities of ultrasonic NDT techniques. Due to increased computing power and better capability to manage large data sets of the new generation ultrasonic equipment, advanced imaging techniques like TFM are now available. Unfortunately, these techniques are not yet recognized by standards and can’t be used alone during the critical inspection. On the other hand, they can be a big help in improving defects characterisation when used in conjunction with standards-approved methods. In this paper, we will demonstrate that the combination of Phased Array inspection with advanced imaging techniques, can enhance the defects characterisation process for common applications of ultrasonic testing.
Badania ultradźwiękowe Phased Array wykazały się przez lata wieloma zaletami w porównaniu do konwencjonalnych technik w tym: szybkością, niezawodnością, wyższą rozdzielczością i czułością. O ile zajęło to trochę czasu, aby stała się metodą adekwatną do badań prowadzonych w terenie, obecnie jest powszechnie uważana za technikę kompleksowych inspekcji. W tym samym czasie technologia ta nadal była rozwijana, skutkując zwiększeniem możliwości ultradźwiękowych technik NDT. Zwiększona moc obliczeniowa i lepsze możliwości zarządzania dużymi zbiorami danych uzyskanymi za pomocą urządzeń ultradźwiękowych nowej generacji wpłynęły na udostępnienie zaawansowanych technik obrazowania, takich jak TFM. Niestety, techniki te nie są jeszcze rozpoznawane przez normy i nie mogą być używane samodzielnie podczas krytycznych inspekcji. Z drugiej strony mogą być bardzo pomocne w poprawie charakterystyki wskazań w połączeniu z metodami zatwierdzonymi przez normy. W tym artykule pokażemy, że połączenie kontroli Phased Array z zaawansowanymi technikami obrazowania może poprawić charakterystykę wskazań dla typowych zastosowań badań ultradźwiękowych.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 3; 42-47
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies