Tytuł:
The influence of the transducer bandwidth and double pulse transmission on the encoded imaging ultrasound
Autorzy:
Trots, I.
Nowicki, A.
Lewandowski, M.
Secomski, W.
Litniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/331651.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
encoded imaging ultrasound
ultrasound imaging transducer
CGS
Opis:
An influence effect of fractional bandwidth of ultrasound imaging transducer on the gain of compressed echo signal being the complementary Golay sequences (CGS) with different spectral widths is studied in this paper. Also, a new composing transmission method of CGS is discussed together with compression technique applied in order to increase the signal-to-noise ratio (SNR) and penetration. The CGS with two different bit lengths, one-cycle and two-cycles are investigated. Two transducers with fractional bandwidth of 25% and 80% at centre frequency 6 MHz are used. The experimental results are presented, clearly proofing that increasing of the code length leads to compressed echo amplitude enhancement. The smaller the bandwidth is the larger is this effect; the pulse-echo sensitivity of the echo amplitude increases by 1.88 for 25% fractional bandwidth and 1.47 for 80% while preserving time resolution. The presented results of double transmission of short codes show the penetration and SNR improvement while maintaining dead zone.
Źródło:
Hydroacoustics; 2008, 11; 419-430
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonographic criteria of cesarean scar defect evaluation
Ultrasonograficzne kryteria oceny blizny po cięciu cesarskim
Autorzy:
Woźniak, Andrzej
Pyra, Krzysztof
Rio Tinto, Hugo
Woźniak, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/1033144.pdf
Data publikacji:
2018
Wydawca:
Medical Communications
Tematy:
caesarean section
scars
ultrasound imaging
Opis:
Cesarean sections account for approximately 20% of all deliveries worldwide. In Poland, the percentage of women delivering by cesarean section amounts to over 43%. According to studies, the prevalence of cesarean scar defects ranges from 24–70%. Due to the overall cesarean section rate, this is a medical problem affecting a large population of women. In such cases, ultrasonographic evaluation of a cesarean scar reveals a hypoechoic space filled with postmenstrual blood, representing a myometrial tear at the wound site. Such an ultrasound appearance is referred to as a niche, and it forms after a cesarean section at the site of the hysterotomy of the anterior uterine wall, most commonly within the uterine isthmus. Currently, the exact cause of niche formation remains unexplained, yet the risk factors for its development are universally acknowledged. They include the site of hysterotomy, multiple previous cesarean section deliveries, suturing technique and maternal diabetes or smoking. Ultrasound evaluation of the cesarean section scar is an important element of obstetric and gynecologic practice, especially in the case of further pregnancies. It facilitates an early diagnosis of a cesarean scar ectopic pregnancy, and the prediction of the risk for perinatal dehiscence in the case of a vaginal birth after a cesarean section.
Około 20% porodów na świecie odbywa się przez cesarskie cięcie. W Polsce odsetek kobiet rodzących tą metodą sięga ponad 43%. Badania dowodzą, że nieprawidłowości w obrębie blizny po cięciu cesarskim występują z częstością 24–70%. Z uwagi na całkowitą liczbę cięć cesarskich problem nieprawidłowego tworzenia się blizny po tym zabiegu przybiera ogromną skalę. Podczas badania ultrasonograficznego widoczna jest hipoechogeniczna przestrzeń wypełniona krwią pomenstruacyjną, odzwierciedlająca przerwanie myometrium w miejscu uprzedniego cięcia cesarskiego. Obraz ten nazywany jest niszą. Formuje się ona po cięciu cesarskim w miejscu histerotomii przedniej ściany macicy, najczęściej w obrębie cieśni macicy. Nie jest obecnie znana dokładna przyczyna występowania niszy, wiadomo jednak, jakie czynniki mają wpływ na jej powstawanie. Najważniejsze z nich to: miejsce wykonania histerotomii, liczba cięć cesarskich, technika szycia oraz czynniki zależne od samej pacjentki, takie jak cukrzyca czy palenie tytoniu. Ultrasonograficzna ocena blizny po cięciu cesarskim jest istotna w praktyce ginekologiczno-położniczej, szczególnie w przypadku ciąży. Daje możliwość wczesnej diagnostyki ciąży w bliźnie po cięciu cesarskim, a w przypadku planowanego porodu siłami natury umożliwia predykcję ryzyka okołoporodowego rozejścia się blizny po cięciu cesarskim.
Źródło:
Journal of Ultrasonography; 2018, 18, 73; 162-165
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-Element Synthetic Transmit Aperture in Medical Ultrasound Imaging
Autorzy:
Trots, I.
Nowicki, A.
Lewandowski, M.
Tasinkevych, Y.
Powiązania:
https://bibliotekanauki.pl/articles/177855.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound imaging
synthetic aperture
beamforming
Opis:
Synthetic aperture (SA) technique is a novel approach to present day commercial systems and has previously not been used in medical ultrasound imaging. The basic idea of SA is to combine information acquired simultaneously from all directions over a number of emissions and to reconstruct the full image from these data. The paper presents the multi-element STA (MSTA) method for medical ultrasound imaging. The main difference with the STA approach is the use of a few elements in the transmit mode in contrast to a single element aperture. This allows increasing the system frame rate, decreasing the number of emissions, and provides the best compromise between the penetration depth and lateral resolution. Besides, a modified MSTA is proposed with a corresponding RF signal correction in the receive mode, which accounts for the element directivity property. In the experiments a 32-element linear transducer array with 0.48 mm interelement spacing and a burst pulse of 100 ns duration were used. Two elements wide transmission aperture was used to generate an ultrasound wave covering the full image region. The comparison of 2D ultrasound images of a tissue mimicking phantom obtained using the STA and MSTA methods is presented to demonstrate the benefits of the second one.
Źródło:
Archives of Acoustics; 2010, 35, 4; 687-699
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multimodal Ultrasonic Imaging for Breast Cancer Detection
Autorzy:
Camacho, J.
Medina, L.
Cruza, J. F.
Moreno, J. M.
Fritsch, C.
Powiązania:
https://bibliotekanauki.pl/articles/176695.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound imaging
ultrasound tomography
breast cancer
Opis:
Ultrasound is used for breast cancer detection as a technique complementary to mammography, the standard screening method. Current practice is based on reflectivity images obtained with conventional instruments by an operator who positions the ultrasonic transducer by hand over the patient’s body. It is a non-ionizing radiation, pain-free and not expensive technique that provides a higher contrast than mammography to discriminate among fluid-filled cysts and solid masses, especially for dense breast tissue. However, results are quite dependent on the operator’s skills, images are difficult to reproduce, and state-of-the-art instruments have a limited resolution and contrast to show micro-calcifications and to discriminate between lesions and the surrounding tissue. In spite of their advantages, these factors have precluded the use of ultrasound for screening. This work approaches the ultrasound-based early detection of breast cancer with a different concept. A ring array with many elements to cover 360. around a hanging breast allows obtaining repeatable and operator-independent coronal slice images. Such an arrangement is well suited for multi-modal imaging that includes reflectivity, compounded, tomography, and phase coherence images for increased specificity in breast cancer detection. Preliminary work carried out with a mechanical emulation of the ring array and a standard breast phantom shows a high resolution and contrast, with an artifact-free capability provided by phase coherence processing.
Źródło:
Archives of Acoustics; 2012, 37, 3; 253-260
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of the Multi-element Synthetic Transmit Aperture Method for Medical Ultrasound Imaging Applications
Autorzy:
Tasinkevych, Y.
Trots, I.
Nowicki, A.
Lewandowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/177208.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound imaging
synthetic aperture
beamforming
Opis:
The paper presents the optimization problem for the multi-element synthetic transmit aperture method (MSTA) in ultrasound imaging applications. The optimal choice of the transmit aperture size is made as a trade-off between the lateral resolution, penetration depth and the frame rate. Results of the analysis obtained by a developed optimization algorithm are presented. The maximum penetration depth and lateral resolution at given depths are chosen as optimization criteria. The results of numerical experiments carried out in MATLAB Ž using synthetic aperture data of point reflectors obtained by the FIELD II simulation program are presented. The visualization of experimental synthetic aperture data of a tissue mimicking phantom and in vitro measurements of the beef liver performed using the SonixTOUCH Research system are also shown.
Źródło:
Archives of Acoustics; 2012, 37, 1; 47-55
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorithm for Computationally Efficient Imaging of Sound Speed in Conventional Ultrasound Sonography
Autorzy:
Karwat, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/31339779.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
speed of sound
ultrasound imaging
computational complexity
Opis:
The speed of sound (SoS) in tissues reflects their mechanical properties and therefore can carry valuable diagnostic information. In conventional ultrasound sonography (US), however, this information is not readily available. Furthermore, since the actual SoS is unknown, image reconstruction is carried out using an average SoS value for soft tissues. The resulting local deviations from the actual SoS lead to aberrations in US images. Methods for SoS imaging in US therefore have the potential to enable the correction of aberrations in classical US. In addition, they could also become a new US modality. There are several approaches to SoS image reconstruction. They differ in terms of input data requirements, computational complexity, imaging quality, and the potential for signal analysis at the intermediate stages of processing. This article presents an algorithm with multi-stage processing and low computational complexity. The algorithm was verified through numerical simulations and phantom measurements. The obtained results show that it can correctly estimate SoS in layered media, which in most cases model the tissue structure well. With its computational complexity of O(n), the algorithm can be implemented in real-time ultrasound imaging systems with limited hardware performance, such as portable ultrasound devices.
Źródło:
Archives of Acoustics; 2023, 48, 4; 549-558
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of the image compounding methods for the multi-angle 3-D ultrasound imaging
Autorzy:
Sabiniok, Maciej
Opieliński, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/128271.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
Multi-Angle Conventional Ultrasound Imaging
3D ultrasound imaging
image compounding
soft tissue
ultradźwiękowe obrazowanie 3D
tkanka miękka
Opis:
The main goal of the paper is to compare the image compounding methods to minimise the artefacts arising in the Multi-Angle Conventional Ultrasound Imaging (MACUI) due to the system configuration. The MACUI method used for 3-D object imaging and the introduced imaging artefacts are described. Different ways of the image compounding by intensity averaging are presented in the work. Implemented methods of image compounding were tested for different types of objects mimicking soft tissue. The comparison allowed to determine the most appropriate method of intensity averaging in the compounding method. The method can be used to reduce the presence of image artefacts and enhance the quality of the resulting slices which are used to create 3-D volume of an object structure in MACUI method.
Źródło:
Vibrations in Physical Systems; 2019, 30, 1; 1-8
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthetic Aperture Cardiac Imaging with Reduced Number of Acquisition Channels. A Feasibility Study
Autorzy:
Tasinkevych, Y.
Lewandowski, M.
Klimonda, Z.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/177629.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phased-array
ultrasound imaging
diverging wave
synthetic transmit aperture
Opis:
Commercially available cardiac scanners use 64-128 elements phased-array (PA) probes and classical delay-and-sum beamforming to reconstruct a sector B-mode image. For portable and hand-held scanners, which are the fastest growing market, channel count reduction can greatly decrease the total power and cost of devices. The introduction of ultra-fast imaging methods based on plane waves and diverging waves provides new insight into heart’s moving structures and enables the implementation of new myocardial assessment and advanced flow estimation methods, thanks to much higher frame rates. The goal of this study was to show the feasibility of reducing the channel count in the diverging wave synthetic aperture image reconstruction method for phased-arrays. The application of ultra-fast 32-channel subaperture imaging combined with spatial compounding allowed the frame rate of approximately 400 fps for 120 mm visualization to be achieved with image quality obtained on par with the classical 64-channel beamformer. Specifically, it was shown that the proposed method resulted in image quality metrics (lateral resolution, contrast and contrast-to-noise ratio), for a visualization depth not exceeding 50 mm, that were comparable with the classical PA beamforming. For larger visualization depths (80-100 mm) a slight degradation of the above parameters was observed. In conclusion, diverging wave phased-array imaging with reduced number of channels is a promising technology for low-cost, energy efficient hand-held cardiac scanners.
Źródło:
Archives of Acoustics; 2018, 43, 3; 437-446
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mutually Orthogonal Golay Complementary Sequences in Medical Ultrasound Diagnostics. Experimental Study
Autorzy:
Trots, Ihor
Żołek, Norbert
Tasinkevych, Yuriy
Wójcik, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/31340110.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
coded excitation
mutually orthogonal Golay codes
synthetic aperture
ultrasound imaging
Opis:
The objective of this paper is an experimental study of the most crucial parameters of the received acoustic signals (e.g. signal-to-noise ratio (SNR), side-lobes level (SLL), axial resolution) obtained as a result of simultaneous emission of mutually orthogonal Golay complementary sequences (MOGCS) to demonstrate their feasibility of being used in ultrasound diagnostics. Application of the MOGCS in ultrasound measurements allows the image reconstruction time to be shortened without decreasing the resulting quality of reconstructed images in comparison with regular complementary Golay coded sequences (CGCS). In this paper two sets of 16-bits long MOGCS were implemented in the Verasonics Vantage™ (Verasonics Inc., Kirkland, WA, USA) scanner. Ultrasound data were generated using a perfect reflector, a custom-made nylon wire phantom and tissue mimicking phantom. Parameters of the detected MOGCS echoes like SNR, SLL and axial resolution were determined and compared to that of the standard CGCS and the short two-sine cycles pulse. It was evidenced that applying MOGCS did not compromise the parameters of the separated and compressed echoes in comparison to the other types of transmitted signal – the CGCS and the short pulse. Concretely, both the MOGCS and CGCS yield similar SNR increase in comparison to the short pulse. Almost similar values of the axial resolution estimated at the full width at the half maximum level for all types of the transmitted signals were also obtained. At the same time, using the MOGCS the data acquisition speed can be increased twice in comparison with the CGCS signal.
Źródło:
Archives of Acoustics; 2022, 47, 3; 399-405
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mutually Orthogonal Golay Complementary Sequences in Synthetic Aperture Imaging Systems
Autorzy:
Trots, I.
Powiązania:
https://bibliotekanauki.pl/articles/178145.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
coded excitation
mutually orthogonal Golay codes
synthetic aperture
ultrasound imaging
Opis:
The main objective of this study is to improve the ultrasound image by employing a new algorithm based on transducer array element beam pattern correction implemented in the synthetic transmit aperture (STA) method combined with emission of mutually orthogonal complementary Golay sequences. Orthogonal Golay sequences can be transmitted and received by different transducer elements simultaneously, thereby decreasing the time of image reconstruction, which plays an important role in medical diagnostic imaging. The paper presents the preliminary results of computer simulation of the synthetic aperture method combined with the orthogonal Golay sequences in a linear transducer array. The transmission of long waveforms characterized by a particular autocorrelation function allows to increase the total energy of the transmitted signal without increasing the peak pressure. It can also improve the signal-to-noise ratio and increase the visualization depth maintaining the ultrasound image resolution. In the work, the 128-element linear transducer array with a 0.3 mm pitch excited by 8-bits Golay coded sequences as well as one cycle at nominal frequencies of 4 MHz were used. The comparison of 2D ultrasound images of the phantoms is presented to demonstrate the benefits of a coded transmission. The image reconstruction was performed using the synthetic STA algorithm with transmit and receive signals correction based on a single element directivity function.
Źródło:
Archives of Acoustics; 2015, 40, 2; 283-289
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Golay Coded Sequences in Synthetic Aperture Imaging Systems
Autorzy:
Trots, I.
Tasinkevych, Y.
Nowicki, A.
Lewandowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/176941.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound imaging
synthetic aperture
beamforming
radiation pattern
coded sequences
Golay codes
Opis:
The paper presents the theoretical and experimental study of synthetic transmit aperture (STA) method combined with Golay coded transmission for medical ultrasound imaging applications. The transmission of long waveforms characterized by a particular autocorrelation function allows to increase the total energy of the transmitted signal without increasing the peak pressure. It can also improve signal- to-noise ratio and increase the visualization depth maintaining the ultrasound image resolution. In the work the 128-element linear transducer array with 0.3 mm pitch excited by the 8 and 16-bits Golay coded sequences as well as a one cycle at nominal frequencies 4 MHz were used. The comparison of 2D ultrasound images of the tissue mimicking phantoms is presented to demonstrate the benefits of coded transmission. The image reconstruction was performed using synthetic STA algorithm with transmit and receive signals correction based on a single element directivity function.
Źródło:
Archives of Acoustics; 2011, 36, 4; 913-926
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
3D Synthetic Aperture Imaging Method in Spectrum Domain for Low-Cost Portable Ultrasound Systems
Autorzy:
Tasinkiewicz, Jurij
Powiązania:
https://bibliotekanauki.pl/articles/31339771.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
ultrasound imaging
matrix transducer
delay-and-sum
Fourier transform
synthetic aperture
Opis:
Portable, hand-held ultrasound devices capable of 3D imaging in real time are the next generation of the medical imaging apparatus adapted not only for professional medical stuff but for a wide group of less advanced users. Limited power supply capacity and the relatively small number of channels used for the ultrasound data acquisition are the most important limitations that should be taken into account when designing such devices and when developing the corresponding image reconstruction algorithms. The aim of this study was to develop a new 3D ultrasound imaging method which would take into account the above-mentioned features of the new generation of ultrasonic devices – low-cost portable general access scanners. It was based on the synthetic transmit aperture (STA) method combined with the Fourier spectrum domain (SD) acoustic data processing. The STA using a limited number of elements in transmit and receive modes for ultrasound data acquisition allowed both aforementioned constraints to be obeyed simultaneously. Moreover, the computational speed of the fast Fourier transform (FFT) algorithm utilized for the ultrasound image synthesis in the spectrum domain makes the proposed method to be more competitive compared to the conventional time domain (TD) STA method based on the delay-and-sum (DAS) technique, especially in the case of 3D imaging in real time mode. Performance of the proposed method was verified using numerical 3D acoustic data simulated in the Field II program for MATLAB and using experimental data from the custom design 3D scattering phantom collected by means of the Verasonics Vantage 256™ research ultrasound system equipped with the dedicated 1024-element 2D matrix transducer. The method proposed in this paper was about 80 times faster than its counterpart based on the time domain synthetic transmit aperture (TD-STA) approach in the numerical example of a single 3D ultrasound image synthesized from 4 partial images each containing 64 × 64 × 512 pixels. It was also shown that the acceleration of the image reconstruction was achieved at the cost of a slight deterioration in the image quality assessed by the contrast and contrast-to-noise ratio (CNR).
Źródło:
Archives of Acoustics; 2023, 48, 4; 559-572
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasound imaging in the general practitioner’s office – a literature review
Diagnostyka ultrasonograficzna w gabinecie lekarza rodzinnego – przegląd piśmiennictwa
Autorzy:
Genc, Alicja
Ryk, Małgorzata
Suwała, Magdalena
Żurakowska, Tatiana
Kosiak, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1052776.pdf
Data publikacji:
2016
Wydawca:
Medical Communications
Tematy:
general practitioners
medical imaging
ultrasonography
ultrasound imaging
badanie obrazowe
diagnostyka ultrasonograficzna
lekarze rodzinni
ultrasonografia
Opis:
Ultrasound, which is a safe and non-invasive diagnostic modality that uses more and more advanced imaging techniques, has become the first-choice examination in various diseases. It is more and more often used in the general practitioner’s office to supplement physical examination and interview. Aim: The aim of this paper is to review the Polish medical literature pertaining to the usage of ultrasound imaging in general practice as well as to present advantages, disadvantages and utility associated with conducting ultrasound examinations by general practitioners based on selected publications. Material and methods: The analysis involved 15 articles found in Polish medical literature published in 1994–2013 in 9 medical journals. These publications were obtained using various data bases, such as Polish Medical Bibliography, Google Scholar as well as websites of “Lekarz Rodzinny” and “Ultrasonografia.” Results: Of 15 available publications, 5 papers present the usage of ultrasound imaging by a primary care physician for general purposes, 4 discuss the usage of abdominal scans, 3 – imaging of the neck and lymph nodes, 1 – lungs, and 2 discuss its usage for specific disease entities. In over 70% of the papers, the financial aspect associated with the usage of this modality in general practice is mentioned. More than a half of the publications draw attention to the possibility of using point-of-care ultrasound examinations. Advantages of ultrasonography most often mentioned by the authors include: good effects of screening, safety, short duration and low cost. The authors of eight publications also indicate disadvantages associated with ultrasound imaging used by a general practitioner. Conclusions: In the Polish literature, there are relatively few papers on the role of ultrasonography in the office of a primary care physician. This modality is more and more often becoming a tool that helps primary care physicians to establish diagnoses, accelerates the initiation of treatment and directs the further diagnostic process.
Ultrasonografia, będąca bezpieczną i nieinwazyjną metodą diagnostyczną, wykorzystującą coraz bardziej udoskonalone techniki obrazowania, stała się badaniem pierwszego wyboru w wielu schorzeniach. Coraz częściej stosowana jest w gabinecie lekarza rodzinnego jako metoda uzupełniająca badania podmiotowe i przedmiotowe. Cel: Celem pracy był przegląd piśmiennictwa polskiego opisującego wykorzystanie badania ultrasonograficznego w gabinecie lekarza rodzinnego oraz przedstawienie zalet, wad i przydatności wykonywania samodzielnego badania ultrasonograficznego przez lekarzy rodzinnych, na podstawie analizy wybranych artykułów. Materiał i metoda: Analiza objęła 15 artykułów wyszukanych w polskim piśmiennictwie, opublikowanych w latach 1994–2013 w 9 czasopismach medycznych. Publikacje znaleziono za pomocą różnych baz danych, takich jak Polska Bibliografia Lekarska, Google Scholar, strony internetowe pism „Lekarz Rodzinny” i „Ultrasonografia”. Wyniki: Z 15 dostępnych publikacji 5 stanowiły artykuły przedstawiające zastosowanie ultrasonografii w gabinecie lekarza rodzinnego w wymiarze ogólnym, w 4 opisano wykorzystanie badania jamy brzusznej, w 3 – szyi i węzłów chłonnych, w 1 – płuc oraz w 2 omówiono badanie w konkretnych jednostkach chorobowych. W ponad 70% prac poruszony został aspekt ekonomiczny związany z zastosowaniem ultrasonografii w gabinecie lekarza rodzinnego. W ponad połowie artykułów zwrócono uwagę na możliwość wykorzystania badań ultrasonograficznych typu point-of-care. Wśród zalet ultrasonografii najczęściej wymieniano korzystne badanie przesiewowe, bezpieczeństwo, krótki czas trwania, niski koszt badania. Autorzy ośmiu publikacji wskazali również wady związane ze stosowaniem USG w gabinecie lekarza rodzinnego. Wnioski: W polskim piśmiennictwie dostępnych jest niewiele publikacji opisujących rolę ultrasonografii w gabinecie lekarza pierwszego kontaktu. Ultrasonograf coraz częściej staje się narzędziem ułatwiającym lekarzowi podstawowej opieki zdrowotnej postawienie diagnozy, przyspiesza też rozpoczęcie leczenia pacjentów i ukierunkowuje dalszą diagnostykę.
Źródło:
Journal of Ultrasonography; 2016, 16, 64; 78-86
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finger joint synovitis detection in ultrasound images
Autorzy:
Radlak, K.
Frackiewicz, M.
Palus, H.
Smolka, B.
Powiązania:
https://bibliotekanauki.pl/articles/947702.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
synovitis
finger joint
seeded region growing
ultrasound imaging
image segmentation
obrazowanie
ultrasonografia
segmentacja obrazu
Opis:
Ultrasonography has proved its usefulness in the evaluation of joint inflammations caused by rheumatoid arthritis. The illness severity is scored by human examiners based on their experience, but some discrepancies in the final diagnosis and treatment frequently occur. Therefore, the main aim of this work is the elaboration of an automatic method of the localization of finger joint inflammation level in ultrasound images. In this paper we propose a novel, fully automated framework for synovitis region segmentation. In our approach we compare several bones and joint localization methods based on the seeded region growing technique, which is combined with different speckle noise filtering algorithms. This technique extracts a region from the image using some predefined criteria of similarity between initially selected point and the pixels in its neighborhood. The seed point is localized automatically as the darkest patch within a small region between two detected finger bones close to the joint. The region affected by synovitis is found using the adopted criterion of homogeneity based on a patch to patch similarity measure. The obtained results exhibit a satisfying accuracy in comparison with the annotations prepared by an expert and the results delivered by semi-automatic methods that require manual bones delineation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 2; 235-245
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odczyny tkankowe powłok brzusznych na szwy chirurgiczne w badaniu ultrasonograficznym
Tissue reactions of abdominal integuments to surgical sutures in sonography
Autorzy:
Smereczyński, Andrzej
Starzyńska, Teresa
Kołaczyk, Katarzyna
Kładny, Józef
Powiązania:
https://bibliotekanauki.pl/articles/1058038.pdf
Data publikacji:
2014
Wydawca:
Medical Communications
Tematy:
abdominal wall
complications
grauloma
sutures
ultrasound imaging
badanie ultrasonograficzne
powikłania
powłoki brzuszne
szwy chirurgiczne
ziarniniak
Opis:
Classical abdominal surgeries usually require long incisions of the abdominal integuments followed by tight closure with adequate suturing material. Nonabsorbable sutures may cause various reactions, including granuloma reactions, both sterile and infl ammatory. The aim of the study was to analyze prospective ultrasound examinations of the abdominal integuments in order to detect tissue reactions to surgical sutures. Material and methods: For 10 years, ultrasound examinations of the abdominal integuments involved the assessment of surgical scars in all patients who underwent open or closed surgeries for various reasons (in total 2254 patients). Ultrasound examinations were performed only with the use of linear probes with the frequency ranging from 7 to 12 MHz. Each scar in the abdominal integuments was scanned in at least two planes. When a lesion was detected, the image was enlarged and the transducer was rotated by approximately 180° in order to capture the dimensions of the granuloma and the most characteristic image of the suture. Moreover, vascularization of the lesion was also assessed with the use of color Doppler mode set to detect the lowest fl ows. Results: All granulomas (19 lesions, two in one patient) created hypoechoic oval or round nodules, were relatively well-circumscribed and their size ranged from 8 × 4 mm to 40 × 14 mm. In the center of the lesion, it was possible to notice a thread that was coiled to various degrees and presented itself as a double, curved hyperechoic line. In 9 out of 19 granulomas, slight peripheral vascularization was observed. The substantial majority of the lesions (n = 15) were in contact with the fascia. In seven patients, compression with the transducer induced known local pain (n = 4) or intensifi ed pain that had already been present (n = 3); all of these granulomas infi ltrated the fascia and showed slight peripheral vascularization. Cutaneous fi stulae developed in two patients with purulent reactions to the running stitch (in one patient – two fi stulae). Conclusions: Suture granulomas in the abdominal integuments manifest themselves as nodular hypoechoic lesions, usually localized at the edge of the fascia – subcutaneous fat. A pathognomonic sign of this type of granulomas is the presence of a thread in their center that usually manifests itself as a chaotically shaped, double hyperechoic line. In some granulomas, particularly those with clinical presentation, slight peripheral vascularization is observed.
Klasyczne operacje brzuszne zazwyczaj wymagają długich nacięć powłok, a następnie ich szczelnego zamknięcia za pomocą odpowiedniego materiału szewnego. Głównie niewchłanialne szwy mogą powodować różne reakcje, w tym odczyny ziarniniakowe o charakterze jałowym lub zapalnym. Celem pracy jest analiza prospektywnych badań ultrasonografi cznych powłok brzusznych ukierunkowanych na wykrycie odczynów tkankowych na zastosowane nici chirurgiczne. Materiał i metoda: Przez 10 lat w badaniach powłok brzusznych każdorazowo oceniano ultrasonografi cznie stan blizny pooperacyjnej u wszystkich pacjentów leczonych z różnych przyczyn chirurgicznie metodą otwartą albo zamkniętą (łącznie 2254 chorych). Badania ultrasonografi czne przeprowadzano wyłącznie głowicami liniowymi o częstotliwości w zakresie 7–12 MHz. Każdą bliznę powłok brzusznych skanowano co najmniej na dwóch przekrojach. W momencie wykrycia zmiany powiększano obraz i wykonywano obrót głowicą w granicach 180°, aby uchwycić największe wymiary ziarniniaka i najbardziej charakterystyczny obraz zwoju nici, a także oceniano jej unaczynienie, używając skali kolorowego dopplera ustawionego na najniższe przepływy. Wyniki: Wszystkie ziarniniaki (łącznie 19, u jednego pacjenta dwa) tworzyły guzki hipoechogeniczne kształtu owalnego lub okrągłego, dość dobrze odgraniczone, wielkości od 8 × 4 mm do 40 × 14 mm. W centralnej części zmiany udawało się wypatrzyć w różnym stopniu zwiniętą nić w formie podwójnej, zakrzywionej linii hiperechogenicznej. W 9 z 19 ziarniniaków zarejestrowano zazwyczaj niewielkie unaczynienie na obwodzie. Zdecydowana większość zmian (n = 15) miała kontakt z powięzią. U siedmiu pacjentów ucisk guzka głowicą wyzwalał znaną bolesność miejscową (n = 4) albo nasilał istniejący ból (n = 3); wszystkie te ziarniniaki naciekały powięź i wykazywały niewielkie unaczynienie na obwodzie. U dwóch osób z ropnym odczynem na założony szew ciągły wystąpiły przetoki skórne (u jednej osoby dwie). Wnioski: Ziarniniaki wokół szwów chirurgicznych w powłokach brzusznych manifestują się jako guzkowa zmiana hipoechogeniczna, najczęściej położona na granicy powięź – tłuszcz podskórny. Patognomonicznym objawem tego rodzaju ziarniniaka jest wykazanie w jego centralnej części nici, która zazwyczaj objawia się bezładnie ukształtowaną, podwójną linią hiperechogeniczną. W części ziarniniaków, zwłaszcza z kliniczną prezentacją, obserwuje się niewielkie unaczynienie obwodowe.
Źródło:
Journal of Ultrasonography; 2014, 14, 56; 21-27
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Assessment of the Impact of Sonication Parameters on Necrotic Lesions Induced in Tissues by HIFU Ablative Device for Preclinical Studies
Autorzy:
Fura, Łukasz
Dera, Wojciech
Dziekoński, Cezary
Świątkiewicz, Maciej
Kujawska, Tamara
Powiązania:
https://bibliotekanauki.pl/articles/1953466.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
automated ultrasound imaging-guided HIFU ablation system
ex vivo tissue
ultrasonic exposure parameters
extent of necrotic lesions
Opis:
We have designed and built ultrasound imaging-guided HIFU ablative device for preclinical studies on small animals. Before this device is used to treat animals, ex vivo tissue studies were necessary to determine the location and extent of necrotic lesions created inside tissue samples by HIFU beams depending on their acoustic properties. This will allow to plan the beam movement trajectory and the distance and time intervals between exposures leading to necrosis covering the entire treated volume without damaging the surrounding tissues. This is crucial for therapy safety. The objective of this study was to assess the impact of sonication parameters on the size of necrotic lesions formed by HIFU beams generated by 64-mm bowl-shaped transducer used, operating at 1.08 MHz or 3.21 MHz. Multiple necrotic lesions were created in pork loin samples at 12.6-mm depth below tissue surface during 3-s exposure to HIFU beams with fixed duty-cycle and varied pulse-duration or fixed pulse-duration and varied duty-cycle, propagated in two-layer media: water-tissue. After exposures, the necrotic lesions were visualized using magnetic resonance imaging and optical imaging (photos) after sectioning the samples. Quantitative analysis of the obtained results allowed to select the optimal sonication and beam movement parameters to suport planning of effective therapy.
Źródło:
Archives of Acoustics; 2021, 46, 2; 341-352
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in the contraction ratio of transversus abdominis and quality of life in patients after total hip replacement and three-compartment knee arthroplasty with implant posterior stabilization
Zmiany współczynnika aktywacji skurczu mięśnia poprzecznego brzucha oraz jakość życia u chorych po przebytej aloplastyce całkowitejstawów biodrowych i aloplastyce trójprzedziałowej stawów kolanowych ze stabilizacją tylną implantu
Autorzy:
Golec, Joanna
Nafalski, Kamil
Turzański, Damian
Masłoń, Agata
Szczygieł, Elżbieta
Czechowska, Dorota
Balicka-Bom, Joanna
Kuzaj, Artur
Golec, Edward
Powiązania:
https://bibliotekanauki.pl/articles/1790963.pdf
Data publikacji:
2018-08-03
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
Core stability
m. transversus abdominis
Rehabilitative Ultrasound Imaging (RUSI)
Stabilizacja centralna
mięsień porzeczny brzucha
fizjoterapeutyczne obrazowanie ultrasonograficzne
Opis:
Core stability is a reference term for the performance of the deep trunk muscles, which provide functional stability of the lumbopelvic area and control the human body in static and dynamic positions. The study group consisted of 30 patients between the age of 42 and 76 years (mean=61.4) after total hip arthroplasty (total hip replacement, Group I) and total knee arthroplasty (three-compartment arthroplasty with posterior stabilization of the implant - Group II). In 18 (60%) patients, hip endoprosthesis was performed, whereas in 12 (40%), three-compartment knee endoprosthesis with posterior stabilization has been implanted. In the study group, Rehabilitative Ultrasound Imaging (RUSI) of the transversus abdominis muscle thickness was conducted at rest and in contraction, the transversus abdominis activation ratio was specified, the SF-36 Life Quality Questionnaire was applied and a three-week treatment cycle was performed. The tests were carried out twice, i.e. before and after treatment. In the group of patients after total hip replacement, the transversus abdominis (TrA) contraction ratio before the beginning of the exercise programme was 0.79±0.06, and after its completion 0.9 ±0.02. The observed difference was statistically significant at p<0.001. In the group of patients after three-compartment knee arthroplasty, the TrA contraction ratio before the beginning of the exercise programme was 0.78±0.09, and after its completion0 0.91±0.02. The difference of these values was statistically significant at the level of p<0.05. The results of the SF-36 questionnaire in both groups indicate improvement in physical functioning. The observed difference was statistically significant at p<0.001. The performed three-week physiotherapy treatment in conjunction with deep muscle training increases the thickness of the TrA muscle during rest and contraction testing, and increases the transversus abdominis contraction ratio in Rehabilitative Ultrasound Imaging in the study groups. Furthermore, improvement in the level of physical functioning was observed within the studied groups.
Wstęp: „Stabilizacja centralna” (ang. core stability) jest terminem odnoszącym się do wydolności mięśni głębokich tułowia, które zapewniają stabilność funkcjonalną okolicy lędźwiowo-krzyżowo-biodrowej oraz kontrolują ciało człowieka w pozycjach statycznych i dynamicznych. Materiał i metody: Grupę badaną stanowiło 30 chorych w przedziale wiekowym 42-76 lat (średnia 61,4 lat) po przebytej aloplastyce całkowitej stawu biodrowego (endoprotezoplastyce – Grupa I) i kolanowego (aloplastyka trójprzedziałowa ze stabilizacją tylną implantu – Grupa II). Spośród nich 18. (60%) chorych stanowiły osoby, u których implantowano endoprotezę do stawu biodrowego, 12 natomiast, (40%) endoprotezę trójprzedziałową stawu kolanowego ze stabilizacją tylną implantu. W grupie badanej wykonano fizjoterapeutyczne obrazowanie ultrasonograficzne (RUSI) grubości mięśnia poprzecznego brzucha w stanie skurczu i rozkurczu, określono współczynnik aktywacji mięśnia poprzecznego brzucha, zastosowano Kwestionariusz Jakości Życia SF-36 oraz przeprowadzono 3-tygodniowy cykl leczenia. Badania wykonano 2-krotnie tzn. przed rozpoczęciem i po zakończeniu leczenia. Wyniki: W grupie chorych po endoprotezoplastyce całkowitej stawu biodrowego współczynnik aktywacji skurczu mięśnia poprzecznego brzucha (TrA) przed rozpoczęciem programu ćwiczeń wynosił 0,79±0,06, a po jego zakończeniu 0,91±0,02. Ustalona jego różnica było istotna statystycznie na poziomie p<0,001. W grupie chorych po endoprotezoplastyce trójprzedziałowej stawu kolanowego współczynnik aktywacji skurczu TrA przed rozpoczęciem programu ćwiczeń kształtował się na poziomie 0,78±0,09, a po jego zakończeniu 0,91±0,02. Różnica tych wartości było istotna statystycznie na poziomie p<0,05. Wyniki kwestionariusza SF-36 w obu grupach świadczą o poprawie funkcjonowania w sferze fizycznej. Różnica ta była istotna statystycznie na poziomie p<0,001. Wnioski: Przeprowadzona 3-tygodniowa fizjoterapia w połączeniu z treningiem mięśni głębokich wpływa na zwiększenie grubości mięśnia TrA podczas badania w rozkurczu oraz w skurczu oraz wpływa na zwiększenie współczynnika aktywacji mięśnia poprzecznego brzucha w fizjoterapeutycznym obrazowaniu ultrasonograficznym w badanych grupach. Zaobserwowano również poprawę poziomu funkcjonowania fizycznego w badanych grupach.
Źródło:
Medical Rehabilitation; 2018, 22(2); 4-10
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Standardy badań ultrasonografi cznych Polskiego Towarzystwa Ultrasonografi cznego – aktualizacja. Badanie ultrasonografi czne tarczycy oraz biopsja tarczycy pod kontrolą ultrasonografi i
Standards of the Polish Ultrasound Society – update. Ultrasound examination of thyroid gland and ultrasound-guided thyroid biopsy
Autorzy:
Trzebińska, Anna
Dobruch-Sobczak, Katarzyna
Jakubowski, Wiesław
Jędrzejowski, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1058058.pdf
Data publikacji:
2014
Wydawca:
Medical Communications
Tematy:
fine needles biopsy
standards
thyroid
thyroid diseases
ultrasound imaging
badanie
biopsja aspiracyjna cienkoigłowa
choroby tarczycy
standardy
tarczyca
ultrasonograficzne
Opis:
Ultrasonography is a primary imaging technique in patients with suspected thyroid disease. It allows to assess the location, size and echostructures of the thyroid gland as well as detect focal lesions, along with indication of their size, echogenicity, echostructure and vascularity. Based on these features, ultrasound examination allows to predict abnormal focal lesions for biopsy and monitor the biopsy needle track. This paper presents the standards of thyroid ultrasound examination regarding ultrasound apparatus technical requirements, scanning techniques, readings, measurements, and the description of the examination. It discusses the ultrasound features of increased malignancy risk in focal lesions (nodules) found in the thyroid gland. It presents indications for fi ne needle aspiration biopsy of the thyroid gland for the visibility of single nodules (focal lesions) and numerous lesions as well as discusses contraindications for thyroid biopsy. It describes the biopsy technique, possible complications and rules for post-biopsy monitoring of benign lesions. The paper is an update of the Standards of the Polish Ultrasound Society issued in 2011. It has been prepared on the basis of current literature, taking into account the information contained in the following publications: Thyroid ultrasound examination and Recommendations of the Polish Ultrasound Society for the performance of the FNAB of the thyroid.
Badanie ultrasonografi czne jest podstawowym badaniem obrazowym u osób z podejrzeniem chorób tarczycy. Pozwala na ocenę położenia, wielkości oraz echostruktury gruczołu, w tym wykrywanie zmian ogniskowych, wraz z określeniem ich rozmiaru, echogeniczności, echostruktury i unaczynienia. Na podstawie tych cech badanie ultrasonografi czne umożliwia wytypowanie nieprawidłowej zmiany ogniskowej do biopsji oraz monitorowanie toru igły biopsyjnej. W publikacji przedstawiono standardy badania ultrasonografi cznego tarczycy dotyczące wymogów technicznych aparatów ultrasonografi cznych, techniki wykonywania badania, wskazań i pomiarów oraz opisu badania. Omówiono cechy ultrasonografi czne zwiększonego ryzyka złośliwości zmian ogniskowych (guzków) w tarczycy. Przedstawiono wskazania do biopsji aspiracyjnej cienkoigłowej tego gruczołu w przypadku uwidocznienia pojedynczego guzka (zmiany ogniskowej) oraz zmian mnogich, a także przeciwwskazania do biopsji tarczycy. Opisano technikę wykonywania biopsji, możliwe powikłania, jak również zasady monitorowania zmian łagodnych po biopsji. Praca stanowi aktualizację Standardów badania ultrasonografi cznego Polskiego Towarzystwa Ultrasonografi cznego wydanych w 2011 roku. Została przygotowana na podstawie aktualnego piśmiennictwa, z uwzględnieniem wiedzy zawartej w dwóch pozycjach: Badanie usg tarczycy oraz Zalecenia Polskiego Towarzystwa Ultrasonografi cznego dotyczące wykonywania BACC tarczycy.
Źródło:
Journal of Ultrasonography; 2014, 14, 56; 49-60
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Standardy badań ultrasonograficznych Polskiego Towarzystwa Ultrasonograficznego – aktualizacja. Badanie nerek, moczowodów oraz pęcherza moczowego
Standards of the Polish Ultrasound Society – update. Ultrasound examination of the kidneys, ureters and urinary bladder
Autorzy:
Tyloch, Janusz F.
Maria Woźniak, Magdalena
Wieczorek, Andrzej Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1058530.pdf
Data publikacji:
2013
Wydawca:
Medical Communications
Tematy:
badanie ultrasonograficzne moczowodów
badanie ultrasonograficzne nerek
badanie ultrasonograficzne pęcherza moczowego
badanie ultrasonograficzne układu moczowego
ultrasound imaging of the urinary system
Opis:
The paper presents the principles of performing proper ultrasound examinations of the urinary tract. The following are discussed: preparation of patients, type of optimal apparatus, technique of examination and conditions which its description should fulfill. Urinary track examination in adults and in children constitutes an integral part of each abdominal examination. Such examinations should be performed with fasting patients or several hours after the last meal, with filled urinary bladder. Apparatus: Ultrasound examinations in children and infants are performed using transducers with the frequency of 5.0–9.0 MHz and in adults – with the frequency of 2.0–6.0 MHz. Doppler options are desirable since they improve diagnostic capacity of sonography in terms of differentiation between renal focal lesions. Scanning technique: Renal examinations are performed with the patients in the supine position. The right kidney is examined in the right hypochondriac region using the liver as the ultrasound “window.” The left kidney is examined in the left hypochondriac region, preferably in the posterior axillary line. Ultrasound examinations of the upper segment of the ureters are performed after renal examination when the pelvicalyceal system is dilated. A condition necessary for a proper examination of the perivesical portion of the ureter is full urinary bladder. The scans of the urinary bladder are performed in transverse, longitudinal and oblique planes when the bladder is filled. Description of the examination: The description should include patient’s personal details, details of the referring unit, of the unit in which the examination is performed, examining physician’s details, type of ultrasound apparatus and transducers as well as the description proper.
Przedstawiono zasady prawidłowego wykonania badania ultrasonograficznego układu moczowego. Uwzględniono przygotowanie chorego, rodzaj optymalnego ultrasonografu, przedstawiono technikę badania oraz warunki, jakie powinien spełniać jego opis. Badanie układu moczowego u dorosłych i u dzieci stanowi integralną część każdego badania jamy brzusznej. Badanie powinno być wykonane na czczo lub kilka godzin po posiłku, z wypełnionym pęcherzem moczowym. Aparatura: Badania u dzieci i niemowląt wykonuje się głowicami o częstotliwości 5,0–9,0 MHz, a u dorosłych o częstotliwości 2,0–6,0 MHz, najlepiej z możliwością badań dopplerowskich. Wykonanie badań dopplerowskich zwiększa możliwości diagnostyczne w różnicowaniu zmian ogniskowych nerek. Technika badania: Badanie nerek wykonywane jest w pozycji leżącej na plecach. Nerkę prawą bada się w prawym podżebrzu, wykorzystując wątrobę jako „okno ultradźwiękowe”. Nerkę lewą bada się w okolicy lewego podżebrza, najlepiej w linii pachowej tylnej. Badanie ultrasonograficzne moczowodów, w ich górnym odcinku, wykonuje się po badaniu nerek, w przypadku poszerzenia układu kielichowo-miedniczkowego. Warunkiem dobrze przeprowadzonego badania przypęcherzowego odcinka moczowodu jest wypełnienie pęcherza moczowego. Badanie pęcherza moczowego wykonywane jest, przy jego w ypełnieniu, w przekrojach p oprzecznym i podłużnym o raz w przekrojach skośnych. Opis badania: Opis powinien zawierać dane pacjenta, dane jednostki kierującej, jednostki wykonującej, dane lekarza wykonującego badanie, typ aparatu oraz głowic, a także tekst właściwego opisu badania.
Źródło:
Journal of Ultrasonography; 2013, 13, 54; 293-307
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Guzy i zmiany guzopodobne imitujące raka pęcherza moczowego w badaniu ultrasonograficznym
Sonography of tumors and tumor-like lesions that mimic carcinoma of the urinary bladder
Autorzy:
Smereczyński, Andrzej
Szopiński, Tomasz
Gołąbek, Tomasz
Ostasz, Oksana
Bojko, Stefania
Powiązania:
https://bibliotekanauki.pl/articles/1058049.pdf
Data publikacji:
2014
Wydawca:
Medical Communications
Tematy:
bladder pseudotumors
bladder tumors
ultrasound imaging
urinary bladder neoplasms
guzy pęcherza moczowego
guzy rzekome pęcherza moczowego
nowotwory pęcherza moczowego
ultrasonografia
Opis:
One of the basic abdominal organs that is assessed during transabdominal ultrasound examination for urological reasons is the urinary bladder. The bladder must be fi lled with urine. This is a prerequisite for a reliable assessment and, at the same time, an acoustic window in examining adjacent structures and organs, for instance the prostate gland. In some cases, doubts occur with respect to the nature of lesions detected. The paper presents anatomic lesions, defects and pathologies which might be erroneously interpreted as tumors of the urinary bladder, i.e. transitional cell carcinoma of the urinary bladder. The following lesions are discussed: 1) anatomic defects (including urachus remnants, ligaments that stabilize the bladder or cyst in the opening of the ureter into the bladder – ureterocele); 2) tumorlike lesions in the lumen of the urinary bladder (such as blood clots, fungus balls, stones or foreign bodies); 3) bladder wall pathologies (i.e. cystitis or endometriosis), focal decidual transformation of stromal cells or infl ammatory pseudotumor; 4) lesions impressing on the bladder from the outside (the mesentery of the sigmoid colon, the bowel, pathological lesions in organs adjacent to the urinary bladder, infl ammatory infi ltration, vasogenic compression of the bladder, pelvic lipomatosis, pathological lesions of the pubic symphysis); 5) postoperative lesions. All these lesions may mimic carcinoma of the urinary bladder in sonography. Bearing this fact in mind is signifi cant in establishing a diagnosis. Due to the malignant character of carcinoma of the urinary bladder and the need for aggressive surgical treatment, a correct diagnosis of this disease is essential for patients, particularly because the lack of adequate treatment and delayed treatment considerably affect prognosis.
Jednym z podstawowych narządów jamy brzusznej ocenianych w trakcie badania ultrasonografi cznego przez powłoki jamy brzusznej wykonywanego ze wskazań urologicznych jest pęcherz moczowy. Jego dobre wypełnienie moczem stanowi bezwzględny warunek wiarygodnej oceny, a zarazem okno akustyczne w diagnostyce innych sąsiadujących struktur i narządów, np. stercza. W niektórych przypadkach pojawiają się wątpliwości co do natury wykrytych zmian. W pracy przedstawiono zmiany anatomiczne, wady oraz stany chorobowe, które można mylnie zinterpretować jako guz pęcherza moczowego, czyli rak przejściowokomórkowy pęcherza moczowego. Kolejno omówiono następujące zmiany: 1) wady anatomiczne (w tym pozostałości moczownika, więzadła stabilizujące pęcherz moczowy, torbiel ujścia pęcherzowego moczowodu – ureterocele); 2) zmiany guzopodobne w świetle pęcherza moczowego (tj. skrzepy krwi, kule grzybicze, złogi, ciała obce); 3) patologie ściany pęcherza (tzn. zapalenie pęcherza moczowego, gruczolistość macicy zewnętrzną – endometriozę), ogniskową przemianę doczesnową komórek podścieliska, guza rzekomego zapalnego; 4) zmiany modelujące od zewnątrz pęcherz moczowy (krezkę okrężnicy esowatej, jelito, zmiany chorobowe w narządach przylegających do pęcherza moczowego, naciek zapalny, ucisk pęcherza naczyniopochodny, otłuszczenie miednicy, zmiany patologiczne spojenia łonowego); 5) zmiany pooperacyjne. Wszystkie powyższe zmiany mogą dać obraz ultrasonografi czny imitujący raka pęcherza moczowego. Znajomość tego faktu jest istotna w diagnostyce. Ze względu na złośliwy charakter raka pęcherza moczowego oraz konieczność agresywnego leczenia operacyjnego właściwe rozpoznanie tej choroby ma ogromne znaczenie dla pacjenta, zwłaszcza że nie tylko brak odpowiedniej terapii, ale również jej odwleczenie w czasie znacznie pogarsza rokowanie.
Źródło:
Journal of Ultrasonography; 2014, 14, 56; 36-48
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intra-abdominal fat. Part II: Non-cancerous lesions of the adipose tissue localized beyond organs
Tłuszcz wewnątrzbrzuszny. Część II. Zmiany nienowotworowe tkanki tłuszczowej położonej pozanarządowo
Autorzy:
Smereczyński, Andrzej
Kołaczyk, Katarzyna
Bernatowicz, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/1052724.pdf
Data publikacji:
2016
Wydawca:
Medical Communications
Tematy:
differential diagnosis
fat necrosis
intra-abdominal fat
non-cancerous lesions
ultrasound imaging
martwica tłuszczu
różnicowanie
ultrasonografia
zmiany nienowotworowe
tłuszcz wewnątrzbrzuszny
Opis:
Adipose tissue does not belong to the most favorite structures to be visualized by ultrasound. It is not, however, free from various pathologies. The aim of this paper is to make abdominal cavity examiners more familiar with non-cancerous lesions found in intra-abdominal fat. The main focus is lesions that are rarely discussed in the literature. Visceral adiposity is one of important pathogenetic factors contributing to cardiovascular events, metabolic syndrome and even certain neoplasms. That is why this article exposes sonographic features that are the most characteristic of these lesions. The value of ultrasonography in the diagnosis of this pathology is underestimated, and a number of US scan reports do not reflect its presence in any way. Moreover, the article discusses more and more common mesenteritis, the lack of knowledge of which could pose difficulties in explaining the nature of symptoms reported by patients. Furthermore, this review presents lesions referred to in the literature as focal infarction of intra-abdominal fat. This section focuses on infarction of the greater and lesser omentum, epiploic appendagitis, mesenteric volvulus and focal fat necrosis resulting from pancreatitis. These lesions should be assessed with respect to the clinical context, and appropriate techniques of ultrasonography should be employed to allow careful determination of the size, shape, acoustic nature and location of lesions in relation to the integuments and large bowel, as well as their reaction to compression with an ultrasound transducer and behavior during deep inspiration. Moreover, each lesion must be obligatorily assessed in terms of blood flow. Doppler evaluation enables the differentiation between primary and secondary inflammation of intra-abdominal fat. The paper also draws attention to a frequent indirect sign of a pathological process, i.e. thickening and hyperechogenicity of fat, which sometimes indicates an ongoing pathology at a deeper site. This structure may completely conceal the primary lesion rendering it inaccessible for ultrasound. In such cases and in the event of other doubts, computed tomography should be the next diagnostic step.
Tkanka tłuszczowa nie należy do ulubionych struktur obrazowanych ultrasonograficznie, ale niestety nie jest wolna od różnorodnych patologii. Praca ma przybliżyć lekarzom badającym ultrasonograficznie jamę brzuszną zmiany nienowotworowe, które spotykane są w tłuszczu wewnątrzbrzusznym. Skupiono się głównie na zmianach rzadko omawianych w piśmiennictwie. Otłuszczenie trzewne to jeden z ważnych czynników patogenetycznych incydentów sercowo-naczyniowych, zespołu metabolicznego, a nawet niektórych nowotworów, dlatego w artykule wyeksponowano cechy sonograficzne najbardziej charakterystyczne dla symptomatologii tych zmian. Wartość ultrasonografii w rozpoznawaniu tej patologii jest niedoceniana i przez to w wielu wynikach USG nie znajduje żadnego odzwierciedlenia. Ponadto opisano coraz częściej spotykane zapalenia krezki, których nieznajomość będzie sprawiać kłopoty przy wyjaśnieniu natury dolegliwości odczuwanych przez chorych. Kolejnymi tematami tego opracowania są zmiany określane w piśmiennictwie jako ogniskowy zawał tłuszczu wewnątrzbrzusznego. W tej grupie patologii skupiono się na zawale sieci większej i sieci mniejszej, przyczepków sieciowych, skrętu krezki i ognisk martwicy tkanki tłuszczowej w następstwie zapalenia trzustki. W ocenie tych zmian należy brać pod uwagę kontekst kliniczny oraz odpowiednią metodykę badania USG polegającą na dokładnym określeniu wielkości, kształtu, charakteru akustycznego i lokalizacji zmian względem powłok oraz jelita grubego, a także ich podatności na ucisk głowicą oraz zachowania się w czasie głębokich oddechów. Ponadto każdą zmianę koniecznie należy ocenić pod względem unaczynienia. Na podstawie badania dopplerowskiego będzie można odróżnić od siebie pierwotne zapalenie tłuszczu wewnątrzbrzusznego od zapalenia wtórnego. W pracy zwrócono też uwagę na często spotykany pośredni objaw procesu chorobowego, którego przejawem jest pogrubiała i hiperechogeniczna tkanka tłuszczowa, niekiedy będąca wybijającym się objawem toczącej się głębiej patologii. Taka struktura może całkowicie kryć zmianę pierwotną, która przez to może być niedostępna badaniu USG. W tych przypadkach i przy innych wątpliwościach kolejnym krokiem diagnostycznym powinna być tomografia komputerowa.
Źródło:
Journal of Ultrasonography; 2016, 16, 64; 32-43
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Błędy i pomyłki w diagnostyce ultrasonograficznej tarczycy
Errors and mistakes in ultrasound diagnostics of the thyroid gland
Autorzy:
Dobruch-Sobczak, Katarzyna
Jędrzejowski, Maciej
Jakubowski, Wiesław
Trzebińska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1058062.pdf
Data publikacji:
2014
Wydawca:
Medical Communications
Tematy:
fine needle biopsy
medical mistakes
thyroid
thyroid diseases
ultrasound imaging
biopsja cienkoigłowa
błędy w obrazowaniu tarczycy
choroby gruczołu tarczowego
tarczyca
Opis:
Ultrasound examination of the thyroid gland permits to evaluate its size, echogenicity, margins, and stroma. An abnormal ultrasound image of the thyroid, accompanied by other diagnostic investigations, facilitates therapeutic decision-making. The ultrasound image of a normal thyroid gland does not change substantially with patient’s age. Nevertheless, erroneous impressions in thyroid imaging reports are sometimes encountered. These are due to diagnostic pitfalls which cannot be prevented by either the continuing development of the imaging equipment, or the growing experience and skill of the practitioners. Our article discusses the most common mistakes encountered in US diagnostics of the thyroid, the elimination of which should improve the quality of both the ultrasound examination itself and its interpretation. We have outlined errors resulting from a faulty examination technique, the similarity of the neighboring anatomicalstructures, and anomalies present in the proximity of the thyroid gland. We have also pointed out the reasons for inaccurate assessment of a thyroid lesion image, such as having no access to clinical data or not taking them into account, as well as faulty qualification for a fine needle aspiration biopsy. We have presented guidelines aimed at limiting the number of misdiagnoses in thyroid diseases, and provided sonograms exemplifying diagnostic mistakes.
Badanie ultrasonograficzne tarczycy pozwala na ocenę jej wielkości, echogeniczności, granic oraz podścieliska. Zobrazowanie nieprawidłowego obrazu ultrasonograficznego tarczycy, w połączeniu z innymi badaniami diagnostycznymi, umożliwia podjęcie decyzji terapeutycznych. Obraz ultrasonograficzny prawidłowej tarczycy nie ulega istotnym zmianom wraz z wiekiem pacjenta. Mimo to w obrazowaniu tego gruczołu zdarzają się błędne opisy, wynikające z obecności pułapek diagnostycznych, którym nie są w stanie zapobiec stałe udoskonalanie sprzętu oraz wzrastające doświadczenie badających lekarzy. W artykule przedstawiono najczęstsze pomyłki w obrazowaniu ultrasonograficzym tarczycy, których wyeliminowanie powinno przyczynić się do poprawy jakości badań i ich interpretacji. Omówiono błędy wynikające z niewłaściwej techniki badania, podobieństwa anatomicznych struktur sąsiadujących z tarczycą oraz nieprawidłowych zmian występujących w sąsiedztwie gruczołu tarczowego. Wskazano również przyczyny złej interpretacji obrazu zmian w tarczycy, takie jak brak dostępu do danych klinicznych albo nieuwzględnienie ich, a także błędne kwalifikacje do biopsji cienkoigłowej. Przedstawiono wskazówki dotyczące postępowania w celu zminimalizowania występowania pomyłek w rozpoznawaniu chorób tarczycy oraz zaprezentowano przykłady obrazujące błędy diagnostyczne.
Źródło:
Journal of Ultrasonography; 2014, 14, 56; 61-73
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy aparaty USG należy testować? Doświadczenia własne
Should carry out quality assurance on ultrasound imaging devices? Own experiences
Autorzy:
Kraśnicki, Tomasz
Pater, Elżbieta
Pływaczyk, Roksana
Gałecka, Katarzyna
Witkiewicz, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2146779.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
testy kontroli jakości
obrazowanie ultradźwiękowe
fantom ultradźwiękowy
ocena jakości obrazowania
sprawdzanie obrazu
aparat USG
quality assurance
testing
ultrasound imaging
ultrasound phantoms
image quality assessment
image check
ultrasound devices
Opis:
Pierwsze próby wprowadzenia kontroli jakości w ultrasonografii zostały podjęte na początku lat 90. Od tego czasu wiele krajów (USA, Unia Europejska) wdraża przepisy i zalecenia dotyczące przeprowadzania kontroli jakości w tej dziedzinie. Do tej pory bardzo niewiele państw nie prowadzi kontroli jakości obrazowania w ultrasonografii. Jednym z nich jest Polska. W artykule opisano propozycję testów kontroli jakości obrazowania USG, które powinny zostać wdrożone w Polsce. Podczas opracowania protokołów testowych posiłkowaliśmy się wytycznymi AAPM oraz zaleceniami europejskimi. Testy kontroli jakości USG bazują na doświadczeniu własnym w przeprowadzeniu kontroli jakości obrazowania 53 urządzeń USG. Pomiary przeprowadzono za pomocą dwóch fantomów: CIRS 054GS oraz IBA (Gammex 403 GS LE). Tolerancję pomiarów zaczerpnięto z instrukcji i opisów fantomów oraz zaleceń europejskich i AAPM.
First attempt at quality assurance in ultrasound imaging was introduced in the early 90’s. From then many countries (US, EU) implement regulations and recommendations for conducting quality assurance control tests in this field. Currently there are very few countries which have not established QA in ultrasound imaging. One of these countries is Poland. This article describes a proposal of quality control tests of ultrasound imaging that should be implemented in Poland. In the development of the test protocol, we followed AAPM and European recommendations. The quality control tests are based on our own experience in testing 53 ultrasound devices. Measurements were conducted using two different Ultrasound QA phantoms: CIRS 054GS and IBA (Gammex 403 GS LE). Tolerances for measurement parameters were taken from phantom instructions and descriptions and from the AAPM and EU recommendations.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 5; 345--351
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany patologiczne ręki w badaniu ultrasonograficznym
Sonography of pathological changes in the hand
Autorzy:
Dębek, Anna
Czyrny, Zbigniew
Nowicki, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1058072.pdf
Data publikacji:
2014
Wydawca:
Medical Communications
Tematy:
carpal tunnel syndrome
de Quervain’s disease
fingers
hand
tendons
ultrasound imaging
choroba de quervaina
palce
ręka
ultrasonografia
zespół cieśni kanału nadgarstka
ścięgna
Opis:
Everyday medical practice shows that most common problems within the hand result from overload, injuries and degeneration. Dorsal side pathologies such as de Quervain’s and Wartenberg’s disease, intersection syndrome or degenerative lesions of carpometacarpal joint of the thumb discussed in the paper can be accurately diagnosed and differentiated by means of ultrasound examination. Ultrasound is similarly powerful in detection and grading of traumatic lesions involving extensor tendons and their sagittal bands or the fl exor tendons and their pulleys. In the case of carpal tunnel syndrome one can not only visualize the median nerve but also other structures of the tunnel that may cause compression. Similarly ulnar nerve compression within the Guyon’s canal can be well evaluated. In cases of nerve trauma one can precisely defi ne the level, and in cases of nerve discontinuity, the distance between stumps can be measured which is important in surgery planning. Often nerve trauma is a sequelae of tendon reconstruction. In such cases scars and nerve entrapment can be depicted. Tumors within a hand are usually benign, of which the most common are ganglia. On ultrasound examination a connection between a ganglion and its source (usually a joint or sheath) can frequently be defi ned. The relationship of tumors to nerves, tendon sheaths or vessels may suggest their nature. Ultrasound with dynamic tissue assessment is a very valuable adjunct to clinical examination.
Źródło:
Journal of Ultrasonography; 2014, 14, 56; 74-88
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The role of ultrasound imaging in disease diagnosis and monitoring the effects of physiotherapeutic treatment of the lumbosacral spine – an overview of research
Rola obrazowania ultrasonografi cznego w diagnozowaniu schorzeń oraz monitorowaniu efektów terapii fizjoterapeutycznych kręgosłupa lędźwiowo-krzyżowego – przegląd badań
Autorzy:
Bąk, Danuta
Powiązania:
https://bibliotekanauki.pl/articles/1790810.pdf
Data publikacji:
2019-02-12
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
oblique and transverse abdominal muscles – ultrasound imaging (USG) – lumbosacral spine –motor organ diseases
mięśnie skośne i poprzeczne brzucha – obrazowanie ultrasonograficzne (USG) – odcinek lędźwiowo-krzyżowy kręgosłupa –
schorzenia narządu ruchu
Opis:
Ultrasound Imaging (USG) is a method being increasingly used in physiotherapy. It is applied successfully in the study of joints, tendons and muscles. Muscle ultrasound examination is helpful in diagnosing and the choice of medicinal and therapeutic methods for the treatment of motion organ diseases and monitoring the effects of the utilised physiotherapeutic methods. Therefore, it is used by doctors and increasingly, by physiotherapists. The aim of the study is to present the role of abdominal muscle ultrasound imaging in the diagnosis of lumbar-spine disorders on the basis of the latest available research findings. Literary research was carried out on the basis of a systematic review of domestic and foreign studies in the analysed area. The first part of the paper contains theoretical aspects of the USG examination, including the basics of its use and the principles of exercise, illustrating the potential for using ultrasound imaging as a method of examining the oblique and transverse abdominal muscles. The second part of the article is, in turn, an aggregated set of available results of research on the effectiveness, credibility and reliability of this method in the diagnosis of lumbar spine diseases as well as in monitoring the effects of physiotherapy. The second part of the article ends with the development of a catalogue of drawbacks and advantages of ultrasound imaging in the treatment of motion organ illnesses. The final part of the study is an analysis of the future aspect, with particular emphasis on the direction of development of ultrasound imaging in both orthopaedics, rheumatology and physiotherapy.
Obrazowanie ultrasonograficzne (USG) narządu ruchu jest metodą coraz częściej wykorzystywaną w fizjoterapii. Stosowane jest z powodzeniem w badaniu zarówno stawów, ścięgien jak i mięśni. Badanie USG mięśni jest pomocne w diagnozowaniu oraz doborze leczniczych i terapeutycznych terapii schorzeń narządu ruchu oraz pozwala monitorować efekty zastosowanych metod fizjoterapeutycznych. W związku z tym, jest wykorzystywane przez lekarzy, a także coraz częściej przez fizjoterapeutów. Celem opracowania jest ukazanie roli obrazowania USG mięśni brzucha w diagnozowaniu schorzeń odcinka lędźwiowo-krzyżowego kręgosłupa na podstawie najnowszych, dostępnych w literaturze wyników badań. Badanie literaturowe zrealizowane zostało na podstawie przeglądu badań krajowych i zagranicznych z analizowanego zakresu. Pierwsza część artykułu zawiera teoretyczne aspekty badania USG narządu ruchu, w tym podstawy jego zastosowania i zasady wykonywania oraz przedstawia możliwości zastosowania obrazowania USG jako metody badania mięśni skośnych i poprzecznych brzucha. Drugą część artykułu stanowi z kolei zagregowany zbiór dostępnych wyników badań z zakresu skuteczności, wiarygodności oraz niezawodności tej metody w diagnozowaniu schorzeń odcinka lędźwiowo-krzyżowego kręgosłupa jak również w monitorowaniu efektów terapii fizjoterapeutycznych. Zwieńczenie drugiej części artykułu stanowi opracowanie katalogu wad i zalet metody obrazowania ultrasonograficznego w leczeniu schorzeń narządu ruchu. Finalną częścią opracowania jest z kolei analiza aspektu przyszłościowego ze szczególnym uwzględnieniem kierunków rozwoju obrazowania USG narządu ruchu zarówno w ortopedii, reumatologii jak i fizjoterapii.
Źródło:
Medical Rehabilitation; 2019, 23(1); 29-34
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies