Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "two-stage interpolation" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
A study of the effect of temperature changes on the interpolating time counter
Autorzy:
Sondej, D.
Szplet, R.
Powiązania:
https://bibliotekanauki.pl/articles/114363.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
time interval measurement
time-to-digital conversion
two-stage interpolation
time counter
Opis:
This paper presents an analysis of the impact of ambient temperature changes on main parameters of the interpolating time counter. The performed tests reveal that a relatively small change in the ambient temperature of 1°C causes a measurement error of the counter as large as 3.5 ps. The thorough research of two stages of interpolation of the counter allowed determining the main sources of the error. One of them is the temperature drift of widths of four-phase clock (FPC) segments in the first interpolation stage (FIS). It equals 2.5 ps/°C. The widths of FPC phases directly influence the active range of the second interpolation stage (SIS) and its offset. The test results also show that the temperature drift of the offset has a greater impact on the measurement accuracy than the temperature-driven changes of quantization steps in SIS. The presented conclusions are the first step to develop a new method for reducing the impact of changes in the ambient temperature on the measurement accuracy of the interpolating time counter.
Źródło:
Measurement Automation Monitoring; 2015, 61, 7; 302-304
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of quantization steps of time interpolator in view of temperature changes
Autorzy:
Sondej, D.
Szplet, R.
Powiązania:
https://bibliotekanauki.pl/articles/114194.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
time-digital conversion
two-stage interpolation
multi-edge coding in independent coding lines
time counter
time digitizer
Opis:
This paper presents a method of limiting the effect of ambient temperature drift on the measurement uncertainty of a time counter (TC). A change in ambient temperature causes a change in the TC transfer function, i.e. the widths of quantization steps to be exact. Recalibration is a procedure that is then required, but it disturbs the measurement process. However, with the knowledge of the current ambient temperature and having the set of transfer functions identified at different temperatures, it is possible to determine and use the most adequate transfer function and virtually eliminate the temperature impact. For this purpose, three interpolation methods were studied: the nearest neighbor method, linear and polynomial interpolations. A newly evaluated transfer functions were tested in interpolating TC to select the best interpolation method.
Źródło:
Measurement Automation Monitoring; 2017, 63, 5; 192-194
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielokanałowy modułowy licznik czasu z użyciem układów programowalnych
A modular multi-channel time counter using programmable devices
Autorzy:
Różyc, K.
Szplet, R.
Kwiatkowski, P.
Sawicki, M.
Jachna, Z.
Powiązania:
https://bibliotekanauki.pl/articles/158352.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
układy programowalne
przetworniki czasowo-cyfrowe
licznik czasu
interpolacja dwustopniowa
time counter
programmable device
time-to-digital converter
two-stage interpolation
Opis:
Przedstawiono budowę, zasadę działania i wyniki badań wielokanałowego modułowego licznika czasu. Umożliwia on równoczesny pomiar relacji czasowych pomiędzy impulsami wejściowymi (START), pochodzącymi z maksymalnie sześciu niezależnych źródeł zegarowych, a wspólnym dla wszystkich kanałów impulsem odniesienia (STOP). Moduły pomiarowe licznika wykonano z użyciem układów programowalnych FPGA Spartan-3 (Xilinx). Licznik charakteryzuje się zakresem pomiarowym do 1 s oraz precyzją pomiarów nie gorszą niż 250 ps.
We present the design, operation and test results of a modular multichannel time counter built with the use of programmable devices. Its resolution is below 50 ps and the measurement range reaches 1 sec. The design of the counter is shown in Fig. 1. It consists of six independent measurement modules. Each measurement module contains a 2-channel time interval counter (Fig. 2) implemented in a general-purpose reprogrammable device Spartan-3 (Xilinx). To obtain both high precision and wide measurement range, the counting of periods of a reference clock is combined with a two-stage interpolation within a single period of the clock signal [6]. The interpolation involves a four-phase clock in the first interpolation stage [8] and a time delay coding line in the second interpolation stage. The reference clock module contains an integrated digital synthesizer [7], that provides the reference clock signal of 250 MHz for measurement modules, and is driven by an external clock source of 5 MHz or 10 MHz. The standard measurement uncertainty of the time counter was tested (Figs. 3 and 4) carefully and it did not exceed 250 ps in the full measurement range. As the acid test of the time counter, the differences between signals of 1 PPS from the tested clock sources and the reference 1 PPS signal were also verified (Figs. 5 and 6). The modular design makes the multi-channel time counter easy to modify to meet requirements of various applications.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 7, 7; 432-434
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Scalony licznik czasu z użyciem stempli czasowych i interpolacji dwustopniowej
An integrated time counter based on timestamps and two-stage interpolation
Autorzy:
Kwiatkowski, P.
Szplet, R.
Jachna, Z.
Różyc, K.
Powiązania:
https://bibliotekanauki.pl/articles/157252.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
układy programowalne
przetworniki czasowo-cyfrowe
metoda stempli czasowych
interpolacja dwustopniowa
programmable device
time-to-digital converters
time stamps method
two-stage interpolation
Opis:
W artykule opisano budowę i działanie licznika czasu opartego na metodzie stempli czasowych i dwustopniowej interpolacji. Licznik został zaimplementowany w układzie programowalnym FPGA Kintex-7 firmy Xilinx. Pokazano sposób tworzenia stempli czasowych o wysokiej rozdzielczości oraz opisano problemy projektowe pojawiające się podczas implementacji projektu w układzie FPGA. Opracowany licznik charakteryzuje się wysoką rozdzielczością (< 11,6 ps) i precyzją (< 12 ps) oraz dużą szybkością powtarzania pomiarów (do 12 milionów pomiarów na sekundę). Słowa kluczowe: układy programowalne, przetworniki czasowo-cyfrowe, metoda stempli czasowych, interpolacja dwustopniowa.
This paper presents an integrated time counter based on timestamps and two-stage interpolation methods implemented in an FPGA programmable device. The timestamps method [2, 3] is useful, among others, in physical experiments and laser ranging systems [2, 4, 5]. To obtain high (picoseconds) resolution, it can be combined with the Nutt interpolation method [1, 6]. The principle of measurement is described in Section 2 and shown in Fig. 1. The time counter contains a period counter, a period counter register and 8 independent channels (Fig. 2, Section 3). Each channel consists of a multiphase clock generator, first and second interpolation stage modules and a channel register. The principle of operation and the way of implementing them in a Kintex-7 FPGA device (Xilinx) [7] are also presented in Section 3. The time counter was examined in terms of resolution and precision for each measurement channel (Section 4). The resolution was evaluated using the statistical code density test [8] and its value was below 12 ps. In Fig. 3 there is shown the time counter precision. In the range up to 1 ms it does not exceed 12 ps. For longer time intervals the precision is worsened by the limited stability of the reference clock. The maximum measurement rate for a single channel was experimentally estimated as 12 million measurements per second. The presented time counter is characterized by high metrological parameters (due to the interpolation method) and wide functionality (due to the time stamps).
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 7, 7; 435-437
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies