Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "treatment wetland" wg kryterium: Temat


Wyświetlanie 1-24 z 24
Tytuł:
Operational problems of constructed wetland for landfill leachate treatment: case study
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/125011.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
treatment wetland
landfill leachate
clogging
Opis:
The present paper discusses the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and the evaluation of a wetland system designed for treatment of the leachate. The research has been conducted during a 5-year period. The constructed wetland for leachate treatment was built in 2001; it consists of 2 horizontal subsurface flow reed beds, working in parallel. In the period 2005–2006 it underwent modernization due to unsatisfactory treatment results caused by bed clogging. After the modernization the treatment effectiveness is satisfactory. The effluent from bed I met Polish outflow standards, while in the effluent from bed II COD, total N and TSS exceeded the required concentrations. In spite of this, pretreatment of leachate (iron removal) should be quickly introduced to protect the system against the reoccurrence of clogging problems.
Źródło:
Journal of Ecological Engineering; 2013, 14, 3; 53-58
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sewage gardens – constructed wetlands for single family households
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Kołecka, K.
Powiązania:
https://bibliotekanauki.pl/articles/208217.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
przydomowa oczyszczalnia hydrofitowa
przydomowe oczyszczalnie
oczyszczanie hydrofitowe
roślinne oczyszczalnie ścieków
domy jednorodzinne
oczyszczanie ścieków
household sewage treatment wetland
household sewage
wetland treatment
treatment wetland (TWs)
wastewater treatment plant
single family
wastewater treatment
Opis:
During the last 30 years the increase of interest in low-cost decentralized and small wastewater treatment plants (WWTP) is observed in Europe. For this purpose, sand filters, stabilization ponds, mini reactors with activated sludge, trickling filters and treatment wetlands are used. Among the listed facilities, treatment wetlands (TWs) offer effective and reliable treatment efficiency, being at the same time low-cost and simple in operation. This is a sustainable treatment technology which does not generate secondary sewage sludge. In the paper, design concept and performance of nine TWs constructed in 2009 for single-family households in Kashubian Lake District is discussed. The treatment efficiency of three different TW configurations is compared. The findings of the study provide a basis for future design and implementation of TWs in agricultural areas.
Źródło:
Environment Protection Engineering; 2015, 41, 4; 71-82
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational problems of constructed wetland for landfill leachate treatment: case study
Problemy z eksploatacją systemów hydrofitowych dooczyszczania odcieków ze składowiska: studium przypadku
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/401274.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
system hydrofitowy
odciek ze składowiska
zatykanie się
treatment wetland
landfill leachate
clogging
Opis:
In the paper the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and evaluation of a wetland system designed for treatment of the leachate are discussed. The research has been conducted during the 5 years period. The constructed wetland for leachate treatment, consisting of 2 horizontal subsurface flow reed beds, working in parallel was built in 2001. In the period 2005-06 it underwent modernization due to unsatisfactory treatment results caused by clogging of the beds. The treatment effectiveness after modernization is satisfactory. The effluent from bed I met Polish outflow standards, while in the effluent from bed II COD, total N and TSS exceeded the required concentrations. In spite of this, pre-treatment of leachate (iron removal) should be quickly introduced to protect the system against the repetition of clogging problems.
Opisane w artykule badania prowadzono w okresie pięciu lat. System hydrofitowy zbudowany w 2001 roku do oczyszczania odcieków ze składowiska składa się z dwóch poziomych złóż o przepływie podpowierzchniowym, w układzie równoległym. W 2005-2006 roku wykonano modernizację układu ze względu na problem z zatykaniem się złóż. Efektywność oczyszczania po modernizacji jest zadowalająca, odpływ ze złoża I spełnia polskie normy, natomiast w przypadku złoża II zaobserwowano przekroczenia ChZT i zawiesiny ogólnej. W celu uniknięcia zatykania się złóż należy zastosować wstępne oczyszczanie odcieków.
Źródło:
Inżynieria Ekologiczna; 2011, 25; 202-210
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ okresu eksploatacji na efektywność pracy oczyszczalni hydrofitowej w Małyszynie
Period of operation impact on the effectiveness of work constructed wetland in Małyszyn
Autorzy:
Jakubaszek, A.
Płuciennik-Koropczuk, E.
Powiązania:
https://bibliotekanauki.pl/articles/372578.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
oczyszczalnie hydrofiltrowe
poziomy przepływ ścieków
efektywność usuwania zanieczyszczeń
wastewater treatment
treatment wetland
SS-HF subsurface horizontal flow
Opis:
W artykule przedstawiono efektywność usuwania zanieczyszczeń organicznych oraz związków biogennych ze ścieków w oczyszczalni hydrofitowej w Małyszynie. Wyniki wieloletniego monitoringu pracy oczyszczalni wykazują, że średnia efektywność usuwania zanieczyszczeń organicznych ze ścieków wynosiła 72% Natomiast azot ogólny i fosfor ogólny usuwane były ze ścieków w 22,5 i 13,3%. Wykazano również okresowe odładowanie złoża z wcześniej zdeponowanego fosforu.
This paper presents the pollutant removal efficiency of organic and biogenic compounds from wastewater in constructed wetland in Małyszyn. The results of long-term monitoring of wastewater treatment operation show that the efficiency of removal of organic pollutants from wastewater was 72%. However, total nitrogen and total phosphorus removed from wastewater were on average 22.5 and 13.3%. It was also demonstrated periodically landward of previously deposited phosphorous.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2012, 148 (28); 97-106
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cod Fractions Changes During Sewage Treatment With Constructed Wetland
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/123349.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
COD
sewage treatment
wetland
Opis:
The purpose of the presented research work was to find out COD fractions in raw wastewater and during treatment with constructed wetland (CW) system. The tests were performed in CW system with average flow of about 4 m3/day. In raw wastewater the highest concentration of fraction in organic suspended solid easy biodegradable (XS – 250 mg O2/l) was observed. The same situation was with dissolved organic easy biodegradable matter (SS – 250 mg O2/l). Lower quantity of non-biodegradable fractions dissolved and in suspended solids were observed (SI – 27 mg O2/l, XI – 83.33 mg O2/l). More than 80% of total COD was as biodegradable fractions (SS + X). After treatment with CW system the highest concentration was observed for dissolved non biodegradable fraction (SI – 27 mg O2/l). Lower concentration was for biodegradable fraction in suspended solid (XS – 3.33 mg O2/l). More than 89% of total COD was in biological non-biodegradable fraction (SI + XI).
Źródło:
Journal of Ecological Engineering; 2015, 16, 3; 43-48
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Textile Wastewater Treated by Constructed Wetlands – A Critical Review
Autorzy:
Hussein, Amjad
Powiązania:
https://bibliotekanauki.pl/articles/24201781.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
azo dye
constructed wetland
textile wastewater
treatment
Opis:
Textile industries are among the most environmentally unsustainable businesses, releasing large amounts of effluent that endangers ecosystem health. Constructed wetlands (CWs) are low-cost eco-technical treatments for industrial wastewater control. The CWs are self-contained remediation systems that do not require external energy and have basic mechanisms for pollutant removal, such as biological, chemical, and physical processes. For more than sixty years, constructed wetlands have been utilized to clean wastewater. Most applications have been developed to treat municipal or household wastewater, although CWs are now successfully used to treat a wide range of wastewater types. Constructed wetlands were also employed to treat textile industry effluents in the 1990s. The survey indicated that textile manufacturing wastewaters were treated using subsurface and surface-flow wetlands. Both horizontal and vertical flow systems have been designed within subsurface flow-created wetlands. In addition, many hybrid-built wetlands have recently been documented in the literature for textile industrial wastewater treatment. According to the survey, textile industrial wastewater is treated in constructed wetlands on all continents, and this research includes the data from 65 constructed wetlands in 21 nations worldwide. This paper examined the latest improvements and discoveries in CWs and the many types of CWs used for textile wastewater treatment. The paper also demonstrated state-of-the-art integrated technologies for improving the performance and sustainability of CWs, such as CW-MFC systems.
Źródło:
Journal of Ecological Engineering; 2023, 24, 5; 256--275
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetics of Pollutants Removal in Wetlands Influenced by Retention Time and Number of Plants Using Cyperus alternifolius
Autorzy:
Rahman, Danar Arifka
Priambodo, Eka Wahyudi
Caturputranto, Trisnadi Widyaleksono
Wahyudianto, Febri Eko
Powiązania:
https://bibliotekanauki.pl/articles/2202280.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
Cyperus alternifolius
kinetics
wastewater treatment
Opis:
Constructed wetland is considered an alternative for domestic wastewater treatment in cities. This study serves to evaluate the removal capacity and kinetics of TSS, COD, phosphate, and surfactant in domestic wastewater with several plants of Cyperus alternifolius, through the use of the constructed wetlands treatment. The overall objective of the study was to determine the ability of Cyperus alternifolius to remove water pollutants in domestic wastewater in several plants. The domestic wastewater was contacted in a batch system. The results indicated that CWs had a good performance on COD, phosphate, and surfactant with removal efficiencies of more than 80%, with a retention time of 8 days and 5 plants. However, the removal of suspended solids was found limited, as shown that the TSS removal efficiency was under 40%. The first-order equation of kinetics described the degradation of pollutants. The q1/2 values, which were defined as the average removal loading prior to the half of the pollutant concentration being removed and represented the removal capacity without limitation of pollutants concentration, were moderately increased with an addition to the number of plants.
Źródło:
Journal of Ecological Engineering; 2022, 23, 12; 37--43
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza statystyczna zawartości azotu ogólnego w złożu oczyszczalni hydrofitowej w Małyszynie
Statistical analysis of total nitrogen in the soil of constructed wetland in Małyszyn
Autorzy:
Jakubaszek, A.
Wojciech, M.
Powiązania:
https://bibliotekanauki.pl/articles/372002.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
oczyszczalnia hydrofitowa
wastewater treatment
constructed wetland
Opis:
Usuwanie związków azotu w oczyszczalniach hydrofitowych uzależnione jest od wielu czynników fizyczno-chemicznych i biochemicznych oraz warunków środowiskowych. W artykule przedstawiono opracowanie statystyczne zawartości azotu ogólnego w złożu hydrofitowym oczyszczalni. Wyniki badań materiału filtracyjnego wykazały, że największą zawartością azotu charakteryzowała się powierzchniowa warstwa gruntu do 20 cm głębokości. Kumulacja azotu ogólnego malała wraz z penetracją w głąb złoża oraz w kierunku odpływu ścieków z oczyszczalni.
Removal of nitrogen from constructed wetlands depends on many physic-chemical and biochemical conditions, deposit and environmental factors. The paper contains the results of statistical analysis the accumulation of total nitrogen in the soil. The results of the research have indicated that the highest content of nitrogen was observed in the surface layer of the soil at a depth of up to 20 cm. The content of total nitrogen has dropped with the penetration depth and towards the sewage flow from the constructed wetland.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2011, 142 (22); 75-85
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving Wastewater Reclamation Using Constructed Wetlands by Artificial Plastic Biofilm Carriers
Autorzy:
Zaboon, Baneen Hussein
Al-Abbawy, Dunya A. H.
Yaseen, Dina A.
Powiązania:
https://bibliotekanauki.pl/articles/2202266.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment
free-water surface
Lemna minor
constructed wetland
Opis:
Increasing the demand for potable water, followed by the high quantity of discharged effluents linked with the water scarcity problems has necessitated giving more attention to improving wastewater treatment processes and operations. The constructed wetland has proven to be an excellent green sustainable technique for purification. This study aimed to examine the performance of four experimental free water surface constructed wetlands (FWSCWs) for the depuration of sewage effluents as a secondary treatment stage during winter season conditions. The objectives were to assess the raw and treated wastewater concentrations, evaluate the removal efficiency of chemical oxygen demand (COD), biological oxygen demand (BOD), nutrients, and total suspended solids (TSS) of each treatment line, and compare the impact of plastic rings (biofilm carriers) and Lemna minor L. with the presence of gravel bed on the treatment efficiency and bacterial growth, as well as assess the plant’s adaption and growth. The results showed that all treatment systems improved the water characteristics, and adding biofilm carriers enhanced the efficiency of water purification, especially BOD reduction. The combination of the plants, biofilm carriers, and gravel in the wetland filter significantly enhanced (ρ < 0.05) the treatment efficiency in terms of TSS, COD, BOD, Ammonia (NH3), Nitrates (NO3), and Orthophosphate (PO4) compared to the control treatment system (gravel bed). Plant growth was restricted in the presence of carriers in the system. Further study for examining the system performance under summer conditions, which may improve the nutrient reduction rates by biofilm carriers, is underway.
Źródło:
Journal of Ecological Engineering; 2022, 23, 11; 241--253
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computational Fluid Dynamics Modeling of Residence Time Distribution in a Field-Scale Horizontal Subsurface Flow Constructed Wetland with Palm Kernel Shell as Substrate
Autorzy:
Okoye, Nelson Mbanefo
Madubuike, Chimaobi Nnaemeka
Nwuba, Ifeanyi Uba
Orakwe, Louis Chukwuemeka
Ugwuishiwu, O. Boniface
Powiązania:
https://bibliotekanauki.pl/articles/1163287.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
COMSOL
Computational Fluid Dynamics
Constructed Wetland
Simulation Modelling
Wastewater Treatment
Opis:
The hydraulic performance of constructed wetlands is often compromised by hydraulic problems. Therefore, the development of an appropriate simulation model to reliably predict how various modifications of bed design and configurations might affect performance will facilitate the design of efficient systems. The aim of this research work is to determine distribution of residence time in a field-scale horizontal subsurface flow constructed wetland with Palm Kernel Shell as substrate. The governing equations of flow in porous media and transport of diluted species were solved using COMSOL Multiphysics 5.3a. The result was validated using experimental data and the model result showed good agreement with a correlation coefficient of 0.99. Alternative wetland designs were assessed for the same flow conditions. The results revealed that a two cell wetland improved short-circuiting flow paths.
Źródło:
World Scientific News; 2018, 109; 60-70
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Trickling Filter and Vertical Flow Constructed Wetland Bed to Treat Sewage from Craft Brewery
Autorzy:
Dąbrowski, Wojciech
Karolinczak, Beata
Powiązania:
https://bibliotekanauki.pl/articles/124568.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
craft brewery
sewage treatment
trickling filter
vertical flow constructed wetland
Certyd
Opis:
In Poland, as well as worldwide, an increase in craft beer production can be observed. In the last several years, more than 150 of such breweries have appeared and according to Polish Brewery Association, their number might ultimately reach 500. Many of them emerge in the areas with no access to a central sewerage system so they have to solve the problem of waste management on their own. The article presents the results of research on the possibility of using a hybrid system for biological treatment of sewage from craft breweries. The sewage came from a craft brewery Waszczukowe located in the Podlaskie province. A laboratory scale model consisted of a trickling filter (TF) (research model Gunt CE701e) and vertical flow constructed wetland (SS-VF). Innovative filling (Certyd produced by LSA company) of TF and SS VF was applied. The conducted study included determining the changes in the sewage parameters during hybrid treatment, as well as TF and SS VF efficiency separately. The aim of the research was to show the possibility of treating sewage to a point when it was possible to discharge it to a receiver, in compliance with the Polish legal regulations. The research results might be used in designing a treatment system or sewage pretreatment in craft breweries. The average efficiency of TF operating with 100% recirculation was 76% for BOD5, 80% for COD, 26% for TN and 34% for TP, while the total treatment efficiency of a hybrid system (TF and SS-VF) was 98%, 98%, 72% and 77%, respectively. The load of TF during operation with recirculation was on average 0.38 kg BOD5 m-2d-1, 0.57 kg COD m-2 d-1. The load of SS-VF was on average 0.09 kg BOD5 m-2 d-1 and 0.12 kg COD m-2d-1. The obtained results of hybrid treatment permitted to discharge the sewage to the receiver.
Źródło:
Journal of Ecological Engineering; 2019, 20, 9; 211-217
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of COD Fractions in Raw Wastewater Flowing into Small and Large Wastewater Treatment Plants
Autorzy:
Ignatowicz, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/124764.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
COD fractions
treatment plants
rotary biological contactor
constructed wetland
activated sludge
Opis:
The aim of the study was to determine and compare the amount and biodegradability of organic compounds determined by the COD measure contained in raw sewage inflowing to small sewage treatment plants and municipal sewage wastewater treatment plants with high personal equivalent (P.E.). Raw sewage samples were collected in three chosen facilities. The research presented in the article were conducted with two small plants: constructed wetland plant with an average capacity of 4 m3/d and the treatment plant with rotary biological contactor (RBC) with an average capacity of 5 m3/d. Also big municipal wastewater treatment plant (WWTP) with activated sludge in Bialystok with a capacity of about 63 000 m3/d was checked. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was founded in raw sewage in small wastewater treatment plants (CW and RBC).
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 197-201
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heavy Metals Removal from Simulated Wastewater using Horizontal Subsurface Constructed Wetland
Autorzy:
M-Ridha, Mohanad J.
Zeki, Suhair L.
Mohammed, Sabah J.
Abed, Khalid M.
Hasan, Hassimi Abu
Powiązania:
https://bibliotekanauki.pl/articles/1955516.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
heavy metal removal
phytoremediation
horizontal subsurface constructed wetland
Nerium oleander
waste treatment
Opis:
This study aimed to assess the efficiency of Nerium oleander in removing three different metals (Cd, Cu, and Ni) from simulated wastewater using horizontal subsurface flow constructed wetland (HSSF-CW) system. The HSSF-CW pilot scale was operated at two hydraulic retention times (HRTs) of 4 and 7 days, filled with a substrate layer of sand and gravel. The results indicated that the HSSF-CW had high removal efficiency of Cd and Cu. A higher HRT (7 days) resulted in greater removal efficiency reaching up to (99.3% Cd, 99.5% Cu, 86.3% Ni) compared to 4 days. The substrate played a significant role in removal of metals due to adsorption and precipitation. The N. oleander plant also showed a good tolerance to the uptake of Cd, Cu, and Ni ions from water. The highest removal of the heavy metals indicated that the HSSF-CW would be a promising technology for heavy metal contaminated wastewater as well as in electroplating and manufacturing industries.
Źródło:
Journal of Ecological Engineering; 2021, 22, 8; 243-250
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reduction of heavy metals from waste water by wetland
Autorzy:
Sahu, O.
Powiązania:
https://bibliotekanauki.pl/articles/10928.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
metal reduction
heavy metal
waste water
wetland
biomass
contaminant
metal ion
natural treatment
Opis:
Constructed wetlands are artificial wastewater treatment systems consisting of shallow ponds or channels which have been planted with aquatic plants, and which rely upon natural microbial, biological, physical and chemical processes to treat wastewater. They typically have impervious clay or synthetic liners, and engineered structures to control the flow direction, liquid detention time and water level. Depending on the type of system, they may or may not contain an inert porous media such as rock, gravel or sand. Constructed wetlands have been used to treat a variety of wastewaters including urban runoff; municipal, industrial, agricultural and acid mine drainage. In this regard’s an attempted has been made to reduce the heavy metal present in waste water.
Źródło:
International Letters of Natural Sciences; 2014, 07
2300-9675
Pojawia się w:
International Letters of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Doświadczenia z eksploatacji urządzeń do oczyszczania ścieków dla terenów niezurbanizowanych
Operation of a small wastewater treatment facilities in a scattered settlement
Autorzy:
Gajewska, M.
Kopeć, Ł.
Obarska-Pempkowiak, H.
Powiązania:
https://bibliotekanauki.pl/articles/1819490.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
tereny nieuzbrojone
oczyszczanie ścieków
systemy hydrofitowe
areas of unarmed
wastewater treatment
wetland systems
Opis:
Problem oczyszczania ścieków bytowych na obszarach niezurbanizowanych należy uznać za aktualny i wymagający rozwiązania w najbliższych latach. W pracy porównano wyniki uzyskane podczas eksploatacji urządzeń (złóż biologicznych z wypełnieniem z tworzyw sztucznych) z pracą obiektów hydrofitowych. Podejmowane działania potwierdzają, że zarówno konstrukcje konwencjonalnych urządzeń mechanicznych oraz nowe konfiguracje systemów hydrofitowych stanowią interesujące rozwiązania dla małych ilości ścieków wytwarzanych na obszarach niezurbanizowanych.
The disproportion between water supply and newly constructed sewer systems have been still increasing. Although, the number of people connected to the sewer system is still increasing but compare other EU countries it is unsatisfying.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 207-225
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nitrogen and phosphorus content in constructed wetlands
Autorzy:
Jakubaszek, Anita
Powiązania:
https://bibliotekanauki.pl/articles/1838101.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
waste water treatment
constructed wetland
nitrogen
phosphorus
oczyszczalnie ścieków
oczyszczalnia hydrofitowa
azot
fosfor
Opis:
High effectiveness of organic pollutants and nutrients removal is achieved in biological wastewater treatments plants – in case of proper exploitation of these objects. Nitrogen and phosphorus transformation or removal depends on many physic – chemical and biochemical conditions, deposit and environmental factors. A rule for treating wastewater consists in decomposition of organic compounds included in wastewater in water-soil environment. Removing contaminations is performed as a result of sorption of contaminations, bio-chemical oxidation-reduction reactions and biological activity of soil microorganisms and hydrophyte flora. The research has been carried out in the constructed wetland in Małyszyn (1300 EP). The treatment plant operates in horizontal system, with under-surface flow of wastewater.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 2; 247-257
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of subsurface vertical flow constructed wetlands receiving municipal wastewater
Autorzy:
Kowalik, P.
Mierzejewski, M.
Randerson, P. F.
Williams, H. G.
Powiązania:
https://bibliotekanauki.pl/articles/241164.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
constructed wetland
municipal wastewater
nitrogen
Phragmites australis
phosphorus
sewage
suspended solids
wastewater treatment
Opis:
The efficiency of pollution removal from municipal sewage in two vertical flow constructed wetlands consisting of gravel filters with a surface area of 4 × 5 m, depth 60 cm, planted with reed (Phragmites) was assessed over a period of about two years. The flow of wastewater was 50 mm per day. Wastewater underwent only primary treatment before application to reed bed B, but reed bed A was supplied with wastewater after mechanical and biological treatment. Measurements were taken of sewage supply and discharge, precipitation and wastewater temperatures. The main indicator of efficiency was the elimination of suspended solids, BOD5, nitrogen and phosphorus from the wastewater during treatment. The elimination of the pollution load was 2-25g O2 per square meter per day for the BOD5 and 0-3.5 g per square meter per day for so-called "total nitrogen". Rates of pollution removal were between 2 and 4 times as high in bed B (after primary treatment) as in bed A (after biological treatment), but the loading rate of bed B was also substantially higher. The rate of BOD5 removal and the coefficient k for BOD5 were greatly dependent on temperature for reed bed B (primary treatment); less so for bed A (biological treatment). The difference between summer and winter temperatures indicates that the surface area of constructed wetland B with wastewater after mechanical treatment should be about 3 times greater during winter, to obtain the summer rate of BOD5 pollution removal in the climatic conditions of Northern Poland (54oN).
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2004, 51, 4; 349-370
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Critical Review on Economical and Sustainable Solutions for Wastewater Treatment Using Constructed Wetland
Autorzy:
Vishwakarma, Smily
Dharmendra, Dr
Powiązania:
https://bibliotekanauki.pl/articles/27314782.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wetland
artificial wetlands
wastewater treatment
low-cost technology
tereny podmokłe
sztuczne tereny podmokłe
oczyszczanie ścieków
technologia niskokosztowa
Opis:
Pollutant removal by the mechanism of constructed wetland has led to low cost, highly efficient wastewater treatment technology. Constructed wetlands (CWs) are artificial engineered systems that mimic like natural wetlands. CW’s have been used in previous research to treat a broad range of waste streams at large-scale for low-cost application in wastewater management. Generally, the most literature has targeted a particular class of mechanism or the other due to lack of generalized techniques for wastewater management using CWs. This work focuses on to introductory information and review on concept of CWs based on the latest mechanisms for the wastewater treatment to inspire economical and sustainable solutions to water based environmental problems. This research emphasis CW mechanism, construction, design, and applications of CWs as well as optimization of CWs for the treatment of wastewater. This review also highlights the study with different treatment stages of CWs for removing pollutants from different types of wastewaters.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 3; 260--284
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekologiczne rozwiązanie gospodarki ściekowej i grzewczej w monasterze w Zwierkach
Ecological sewage management solution and heating in the monastery in Zwierki
Autorzy:
Ignatowicz, K.
Smyk, J
Powiązania:
https://bibliotekanauki.pl/articles/399716.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
przydomowa oczyszczalnia ścieków
oczyszczalnia hydrofitowa
proekologiczne systemy grzewcze
wastewater treatment plants
constructed wetland
environmentally friendly heating systems
Opis:
Przedstawione w pracy badania dotyczą oceny efektywności działania przydomowej oczyszczalni ścieków ze złożem hydrofitowym w Zwierkach. W ściekach pobranych z poszczególnych etapów oczyszczania wykonano analizy BZT5, ChZT, form azotu i fosforu. Na podstawie uzyskanych wyników stwierdzono dużą skuteczność usuwania BZT5, ChZT, azotu amonowego i fosforanów. W pracy zaproponowano także zastosowanie ekologicznego rozwiązania systemu grzewczego oraz redukcję kosztów poprzez modernizację systemu przygotowania ciepłej wody użytkowej w klasztorze w Zwierkach. Założenie przewiduje wspomaganie procesu przygotowania ciepłej wody użytkowej od kwietnia do września za pomocą systemu solarnego w układzie pośrednim, a tym samym częściowe zastąpienie energii pozyskiwanej ze źródeł konwencjonalnych – w tym przypadku z paliwa jakim jest ekogroszek – energią słoneczną pozyskiwaną przez system solarny.
The study focused on the effectiveness of household sewage treatment plant in Zvierki. Were tested wastewater from the septic tank, the well with a diffuser, from the well of sludge, wastewater after filtration through filter with plants and the receiver of treated sewage – the pond. Checked the ability to remove a treatment with respect to BOD5, COD, ammonia nitrogen, nitrates and phosphates. Based on the results high efficiency removal of BOD5, COD, ammonia nitrogen and phosphate. Unfortunately, there was no reduction of nitrates – there has been a significant increase in this ratio from baseline. After comparing the final values to the limit values defined in the Polish legislation, it was found that the test treatment works in accordance with the requirements except for total phosphorus. Proposed reduction of costs through modernization of the domestic hot water in a monastery in Zvierki. The assumption provides support for the process of preparing hot water from April to September, with the solar system in the intermediate system, and thus the partial replacement of energy from conventional sources – in this case, the fuel which is coal – solar energy produced by the solar system.
Źródło:
Inżynieria Ekologiczna; 2014, 40; 7-16
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Survey of plant species present on constructed wetlands in Opalenica municipality
Analiza i porownanie wybranych przydomowych oczyszczalni hydrofitowych na terenie Gminy Opalenica
Autorzy:
Zmirek, M
Gawronski, S.
Powiązania:
https://bibliotekanauki.pl/articles/81657.pdf
Data publikacji:
2009
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
plant species
constructed wetland
Wielkopolska region
Opalenica municipality
village
macrophyte species
small community
waste water treatment
rural community
environment protection
Źródło:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation; 2009, 41, 2; 143-152
0208-5771
Pojawia się w:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych makrofitów na skuteczność oczyszczania ścieków w stokowych złożach filtracyjnych gruntowo-roślinnych
Influence of selected macrophytes on sewage treatment effectiveness in the slope soil-vegetation filtration beds
Autorzy:
Jucherski, A.
Walczowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/239182.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnia hydrofitowa
stokowe złoże gruntowo-roślinne
skuteczność oczyszczania ścieków
makrofity
constructed wetland
slope soil-vegetation bed
sewage treatment efficiency
macrophytes
Opis:
Celem wieloletnich badań była ocena wpływu monokulturowych nasadzeń manny mielec (Glyceria maxima (Hartm.) Holmb.), mozgi trzcinowatej (Phalaris arundinacea L.) i trzciny pospolitej (Phragmites australis) na skuteczność oczyszczania ścieków bytowych w poletkowych segmentach złóż filtracyjnych oraz wybór rośliny najbardziej przydatnej do stosowania na stokowych złożach gruntowo-roślinnych, opracowanych w GCB w Tyliczu. Manna mielec wykazała najlepszą kondycję botaniczną, dobre wskaźniki ewapotranspiracji (7,9 dm3*m-2*d-1) oraz najlepszą średnią wieloletnią skuteczność oczyszczania ścieków, zarówno w składnikach biogennych zanieczyszczeń (92,9% - Ncałk. i 87,4% - P-PO4), jak i we wskaźnikach BZT5 (90,6%) i ChZT (87,9%). Trzcina, ze względu na nadmierną ekspansję korzeniową, stwarza niebezpieczeństwo zagęszczania i wypierania mineralnych składników złóż, natomiast mozga trzcinowata jest mało stabilna pod względem kondycji biologicznej, a jej wpływ na skuteczność oczyszczania ścieków w złożu najmniejszy.
The aim of presented long-term research was to evaluate the influence of particular monocultures: reedgrass (Glyceria maxima Hartm.), reed Canary grass (Phalaris arundinacea L.) and common reed (Phragmites australis), on the effectiveness of household sewage treatment in the plot segments of filtration beds, and to select the most useful plant to be cultivated on slope type soil-vegetation filter beds (constructed wetland) of theTylicz system. The plot overgrown with reed grass showed the best botanical condition, good evapotranspiration rate (7.9 dm3*m-2 per day) and the highest long-term average effectiveness of sewage treatment, both in nutrient components (92.9% Ntot. and 87.4% P-PO4), as well as BOD (90.6%) and COD (87.9%) rates. The common reed, because of its exaggerated root proliferation, creates a danger of thickening and replacing mineral components of the bed. On the other hand, the reed canary grass is biologically unstable and its influence on the effectiveness of sewage treatment in constructed wetland proved to be the least.
Źródło:
Problemy Inżynierii Rolniczej; 2012, R. 20, nr 1, 1; 115-124
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie frakcji CHZT w ściekach surowych dopływających do małych i dużych oczyszczalni ścieków
Comparison of the fractions of cod in raw wastewater influent for small and large sewage treatment
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/401888.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
frakcje ChZT
małe oczyszczalnie ścieków
złoża biologiczne
oczyszczalnia hydrofitowa
oczyszczalnia z osadem czynnym
COD fractions
small sewage treatment plants
rotary biological contactor
constructed wetland
treatment with activated sludge
Opis:
W artykule przedstawiono porównanie udziału frakcji ChZT w ściekach surowych w oczyszczalniach do których spływają małe ilości ścieków oraz oczyszczalnię z dużym przepływem. Porównano oczyszczalnię hydrofitową o średniej przepustowości 4 dm3/m, oczyszczalnię ze złożami biologicznymi o średniej przepustowości 8 dm3/m, oraz oczyszczalnię ścieków z osadem czynnym w Białymstoku o przepustowości około 70 000 m3/d. Najniższe udziały procentowe frakcji rozpuszczonych związków biologicznie nierozkładalnych SI w ściekach surowych odnotowano w małych oczyszczalniach ścieków. Na podstawie dostępnych danych niestwierdzono istotnych zależności między frakcjami XI, SS, XS w ściekach surowych a ilością wytwarzanych ścieków.
The article presents a comparison of the share fraction of COD in raw wastewater in treatment plants which flow in a small amount of wastewater and the sewage treatment with high flow. Compared the constructed wetlands with an average capacity of 4 dm3/m,, the treatment plant with biological deposits with an average capacity of 8 dm3/m, and a sewage treatment plant with activated sludge in Bialystok with a capacity of about 70 000 dm3/m. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was reported in raw sewage in small sewage treatment plants. Based on the available data wasn’t found significant correlation between the factions XI, SS, XS in raw sewage and the amount of wastewater.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 191-195
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Influence of a Hybrid Constructed Wetland Wastewater Treatment Plant on the Water Quality of the Receiver
Analiza wpływu hybrydowej gruntowo-roślinnej oczyszczalni ścieków na jakość wód odbiornika
Autorzy:
Gizińska-Górna, M.
Jóźwiakowski, K.
Marzec, M.
Pytka, A.
Sosnowska, B.
Różańska-Boczula, M.
Listosz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1813901.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
constructed wetland system
wastewater treatment
surface water
sewage receiver
river
water quality
oczyszczalnie gruntowo-roślinne
oczyszczalnie ścieków
wody powierzchniowe
odbiornik ścieków
rzeka
jakość wód
Opis:
This paper presents the results of research on the impact of the composition of wastewater discharged from a hybrid constructed wetland wastewater treatment plant on the quality of water in the Urzędówka River, a right tributary of the Wyżnica River. During the years 2011-2013, samples of treated wastewater and water from the river were collected (upstream and downstream of the wastewater discharge point) and subjected to physicochemical analysis and, in 2013, also to microbiological analysis. The study showed that the treated wastewater outflowing from the treatment plant did not have any negative influence on the quality of the water in the receiver. Water from the Urzędówka River met clarity standards for class I waters; only the concentrations of total phosphorus and nitrate nitrogen exceeded the limit values for water clarity class II. The studies have shown that waters from the Urzędówka River upstream of the treatment plant contained a huge concentration of E. coli bacteria, fecal coliform bacteria and fecal enterococci, which indicates the impact of other sources of microbiological pollution.
W pracy przedstawiono wyniki badań dotyczące wpływu ścieków odprowadzanych z hybrydowej oczyszczalni hydrofitowej na jakość wód z rzeki Urzędówki, prawostronnego dopływu rzeki Wyżnicy. Próby ścieków oczyszczonych oraz wód z rzeki (powyżej i poniżej miejsca zrzutu ścieków) do analiz fizyczno-chemicznych pobierano w latach 2011-2013, a do analiz mikrobiologicznych w 2013 roku. Na podstawie wyników badań stwierdzono, że ścieki oczyszczone, odpływające z gruntowo-roślinnej oczyszczalni nie miały negatywnego wpływu na jakość wód odbiornika. Wody rzeki Urzędówki odpowiadały I kasy czystości, jedynie zawartość fosforu ogólnego oraz azotu azotanowego przekraczała wartości graniczne określone dla II klasy czystości. W wodzie z rzeki przed zrzutem ścieków oczyszczonych notowano wysoką liczebność bakterii grupy coli i coli typu kałowego oraz enterokoków kałowych, co wskazuje na oddziaływanie innych źródeł zanieczyszczeń mikrobiologicznych.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 370-393
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości oczyszczania ścieków bytowych w quasi technicznej instalacji zagrodowej typu IBMER na terenach górzystych
The quality of farm house-hold wastewater treatment in quasi-technical farmstead installation of IBMER model, in winter period on the mountainous terrain
Autorzy:
Jucherski, A.
Powiązania:
https://bibliotekanauki.pl/articles/238623.pdf
Data publikacji:
2007
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczanie ścieków
obiekt gruntowo-roślinny
klimat
teren górzysty
oczyszczalnia zagrodowa
nitryfikacja
denitryfikacja
wastewater treatment
constructed wetland plant
mountainous climate
farm house-hold wastewater
nitrification
denitrification
ground-vegetable filtration media
Opis:
Przedstawiono wyniki dwuletnich (2005-2006) badań instalacji do oczyszczania ścieków bytowych o wydajności do 1 m3/d, koncepcji IBMER w Tyliczu, składającej się z 3.komorowego osadnika o pojemności czynnej 6 m3, urządzenia ze zraszanym złożem z granulatu ilasto-gliniastego (keramzyt) o powierzchni 2,5 m2 i stokowego złoża glebowo-darniowego o powierzchni 61 m2. Wskaźniki całorocznej skuteczności oczyszczania ścieków w tej instalacji - przy średnim dobowym dopływie 655 l - były znacząco wyższe od obowiązujących wymagań, a niekorzystne warunki zimowe wpływały ujemnie jedynie na efektywność usuwania azotu całkowitego. Średnie wartości wskaźników skuteczności zmniejszania wielkości i stężeń badanych składników zanieczyszczeń wynosiły: 97,9/97,9% BZT5; 94,3/89,2% ChZT; 97,2/99,5% N-NH4; 60,5/78,5% N-NC; 84,4/84,3% P-PO4 (zima/lato). Konieczne jest dalsze technologiczne doskonalenie urządzeń instalacji w celu zwiększenia efektywności denitryfikacji ścieków.
Paper described the results of two-year investigations (2005-2006) of the sewage treatment in single farm purifying installation of treatment output 1 m3 per day. The installation consists of 3 chamber settling tank of 6 m3 active capacity, the plant with sprinkled bed of light expanded clay aggregates (keramzit) of about 2.5 m2 surface and the slope soil-turf filtration bed of 61 m2 surface. The indices of all-year long wastewater treatment effectiveness in tested installation - at average wastewater inflow 655 I per day - were significantly higher than the compulsory requirements, and severe winter conditions affected only the efficiency of total nitrogen removal. Average indices of reducing pollutants quantity and concentration in treated wastewater amounted to: 97.9/97.9% - BOD; 94.3/89.2% - COD; 97.2/99.5% N-NH4; 60.5/78.5% Ntot; 84.4/84.3% P-PO4 (winter/summer). Further technological improvements of the installation would be necessary to increase the efficiency of sewage denitrification.
Źródło:
Problemy Inżynierii Rolniczej; 2007, R. 15, nr 2, 2; 51-60
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-24 z 24

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies