Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "treatment efficiency" wg kryterium: Temat


Tytuł:
Analysis and Assesment of the Wastewater Treatment Plant Operation in the City of Kłodzko
Autorzy:
Garbowski, T.
Wiśniewski, J.
Bawiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/125373.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment system
sewage treatment efficiency
WWTP
treatment plant reliability factor
Opis:
In this study, the current operation efficiency of the wastewater treatment plant (WWTP) in the city of Kłodzko in the Lower Silesia Voivodeship (Poland) was analyzed and the predicted amount of the wastewater flowing to the WWTP in a 20-year period (until the year 2036) was estimated. The data on the quality and the quantity of raw (entering to the WWTP) and treated sewage from the years 2012-2016 were analyzed. The five essential pollutants indicators: biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), total suspended solids (TSS), total nitrogen and total phosphorus, regulated in the water permit were used to evaluate the efficiency of contaminants removal. On the basis of the percentage reduction of the individual pollutants indicators and their acceptable concentrations in the treated sewage, the effectiveness of the operation of the object was determined. Furthermore, a so-called the treatment plant reliability factor (RF) was calculated and its value below 1.0 indicates the correct operation of the wastewater treatment plant. After determining the prospective amount of raw sewage in 2036 (based on the decreasing population in the city) it has been found that the WWTP will work with a significant reserve of capacity and the modernization of the treatment system, leading to a decrease of its capacity should be considered.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 114-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of adsorption efficiencies of Ni (II) in aqueous solutions with perlite via artificial neural networks
Autorzy:
Turp, S. M.
Powiązania:
https://bibliotekanauki.pl/articles/204724.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater
treatment efficiency
adsorption
perlite
artificial neural network
Opis:
This study investigates the estimated adsorption efficiency of artificial Nickel (II) ions with perlite in an aqueous solution using artificial neural networks, based on 140 experimental data sets. Prediction using artificial neural networks is performed by enhancing the adsorption efficiency with the use of Nickel (II) ions, with the initial concentrations ranging from 0.1 mg/L to 10 mg/L, the adsorbent dosage ranging from 0.1 mg to 2 mg, and the varying time of effect ranging from 5 to 30 mins. This study presents an artificial neural network that predicts the adsorption efficiency of Nickel (II) ions with perlite. The best algorithm is determined as a quasi-Newton back-propagation algorithm. The performance of the artificial neural network is determined by coefficient determination (R2), and its architecture is 3-12-1. The prediction shows that there is an outstanding relationship between the experimental data and the predicted values.
Źródło:
Archives of Environmental Protection; 2017, 43, 4; 26-32
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ opadów atmosferycznych na bilans ścieków dopływających i odpływających z komunalnej oczyszczalni ścieków
Impact of precipitation on the balance of wastewater treated in municipal wastewater treatment plant
Autorzy:
Pawęska, K.
Duda, P.
Powiązania:
https://bibliotekanauki.pl/articles/401808.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
bilans ścieków
wody opadowe
sprawność oczyszczania
wastewater balance
rainwater
treatment efficiency
Opis:
W pracy przedstawiono wyniki badań dotyczące ilości i jakości ścieków dopływających i odpływających z komunalnej oczyszczalni ścieków w Głogówku w okresie z opadem deszczu i bezopadowym. Dla danych współczynników spływu określono ilości wód deszczowych prowadzonych kanalizacją ogólnospławną oraz zaproponowano rozwiązania mające na celu ograniczenie ilości wód opadowych zasilających oczyszczalnię. Obserwacje prowadzono w okresie 2015–2017. Ilość ścieków poddawanych oczyszczaniu wyniosła 884,6 m3d-1, a pomierzone wartości maksymalnego dopływu do oczyszczalni stanowiły 84,5% wartości projektowej. Skuteczność oczyszczania w całym okresie obserwacji była wysoka i wyniosła odpowiednio 96,8% dla zawiesiny ogólnej, 98% dla BZT5 oraz 91,7% dla ChZT. Podczas trwania obserwacji nie zauważono wpływu zwiększonego dopływu wód deszczowych na jakość ścieków odprowadzanych do odbiornika. Poziom redukcji zanieczyszczeń w okresach zwiększonego dopływu ścieków kształtował się powyżej 90%. Zabiegi zwiększające retencyjność zlewni pozwalają ograniczyć dopływ wód opadowych o 41,3%.
The paper presents the results of research on the quantity and quality of wastewater in municipal wastewater treatment plant in Głogówek in period with and without rainfall. For runoff coefficients, amount of rainwater collected with combined sewerage system was evaluated as well as solutions which could limited the rainwater collected by canalization were proposed. Observations were carried out in the period 2015–2017. The amount of wastewater treated in wastewater treatment plant in Głogówek was 884,6 m3d-1 and the maximum value of inflowing wastewater accounted 84,5% of the project value. The treatment efficiency in research period was high 96,8% for total suspension, 98% for BOD5 and 91,7% for COD respectively. During the observation period, the impact of increased inflow of rainwater on the outflow quality wasn’t observed. The reduction of pollution level in period with increased wastewater inflow was above 90%. The treatments that increased retention of the catchment allow to reduce inflow of rainwater by 41,3%.
Źródło:
Inżynieria Ekologiczna; 2018, 19, 6; 49-56
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Activated Sludge Technology Combined With Hydroponic Lagoon as a Technology Suitable for Treatment of Wastewater Delivered by Slurry Tanks
Autorzy:
Pawęska, K.
Bawiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/125019.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
activated sludge technology
hydroponic lagoon
wastewater delivered by slurry tanks
wastewater treatment efficiency
Opis:
The paper presents information related to the use of hydrophytic technology combined with traditional activated sludge solution for wastewater treatment in areas without central sewage system. The analyzed wastewater treatment plant (WWTP) was operated in activated sludge technology with a hybrid activated sludge reactor where biomass is kept in a settled and suspended form. Treatment system was completed with a hydroponic lagoon. Hydroponic lagoon has been used as tertiary treatment, in which the self-cleaning processes with the participation of the plant has come to an additional reduction of nutrients. The analyzed three-stage treatment plant is located in the municipality of Nowa Sól. Only domestic wastewater delivered by slurry tanks is treated there in the amount of 60 m3/d. During the observation, high average concentrations of total nitrogen (201.0 mgN/dm3) was observed and organic matter expressed by COD reaching 1341.5 mgO2/dm3 and BOD5 on the level of 246.3 mgO2/dm3 were noted. A characteristic feature of the object designed for wastewater treatment delivered by slurry tanks is high irregularity of wastewater supply and high instantaneous loads of pollutants (the system does not provide expansion tank). The biggest inequality factor of the flow to the reactor was observed in December 2014 (Nd=3.9). During the observations days with no inflow of sewage also occurred. The study shows the dynamics of changes in the amount of delivered domestic wastewater and sewage flowing out of the treatment plant including inequality factor. Information about the quality of wastewater was used to determine the reduction of concentrations of pollutants such as organic matter, suspended solids, nitrogen and phosphorus.
Źródło:
Journal of Ecological Engineering; 2017, 18, 2; 29-37
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określenie energochłonności oczyszczalni ścieków mleczarskich S.M. Bielmlek w Bielsku Podlaskim
Evaluation of energy consumption in dairy WWTP Bielmlek Bielsk Podlaski
Autorzy:
Dąbrowski, W.
Żyłka, R.
Powiązania:
https://bibliotekanauki.pl/articles/399893.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki mleczarskie
zużycie energii elektrycznej
efektywność oczyszczania
dairy wastewater
energy consumption
treatment efficiency
Opis:
Oprócz bardzo skutecznego oczyszczania ścieków mleczarskich, wymagane jest małe zużycie energii w celu obniżenia kosztów procesu. Przedstawiono wyniki badań podstawowych parametrów procesu oczyszczania ścieków jak: biochemiczne zapotrzebowanie na tlen, zawartość azotu oraz zawartość fosforu. Określono również zużycie energii z wybranych procesów technologicznych oraz całkowitą konsumpcję energii. Stwierdzono, że około 40,5% energii wykorzystano do napowietrzania komory SBR, 14,6% przeznaczono na proces flotacji rozpuszczonym powietrzem, a resztę do zasilania procesów związanych z obróbką mechaniczną osadu ściekowego. Analizowano wszystkie źródła zużycia energii oraz ich moc. Obliczono wskaźniki zużycia energii i obciążenia. Podjęte badania będą kontynuowane w celu optymalizacji zużycia energii przy zachowaniu wysokiej efektywności oczyszczania ścieków. Opracowany zostanie model matematyczny po zebraniu odpowiedniej ilości danych, który może być wykorzystany nie tylko w mleczarskich, ale i innych oczyszczalniach ścieków.
Apart from highly efficient treatment of dairy wastewater, a low energy consumption is required in order to lower its costs. During the research period, parameters of raw and treated sewage were tested (BOD, COD, Ntotal, Ptotal). Also, the energy consumption from selected processes as well as the total consumption were measured. It was observed that about 40,5% of energy was used for aeration in SBR chambers, 14,6% for dissolved air flotation and the rest for processes connected with mechanical treatment and sewage sludge treatment. First, all the sources of energy consumption and their power were analysed. Indicators of energy consumption and removed load were calculated. The conducted research will be continued in order to optimize energy consumption while retaining high efficiency of treatment. A mathematical model will be prepared after data collecting. It can be universally applied in different WWTPs, not only dairy ones.
Źródło:
Inżynieria Ekologiczna; 2015, 43; 68-74
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wybranych parametrów pracy oczyszczalni w technologii „Lemna” na przykładzie gminnej oczyszczalni ścieków w Chmielniku (woj. Podkarpackie)
Analysis of selected operational parameters of „Lemna” treatment plant, on the example of the MWWTP in Chmielnik (Poland, Subcarpathian Province)
Autorzy:
Jurczyk, Ł
Koc-Jurczyk, J.
Winiarska, K.
Powiązania:
https://bibliotekanauki.pl/articles/400273.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki komunalne
Lemna
oczyszczanie ścieków
efektywność oczyszczania
wskaźnik niezawodności
municipal wastewater
wastewater treatment
treatment efficiency
reliability index
Opis:
W pracy przedstawiono analizę pracy gminnej oczyszczalni ścieków typu „Lemna”, a badaniami objęto okres siedmiu lat (2009–2015). Badano sprawność usuwania takich wskaźników jak BZT5, ChZT oraz zawiesiny ogólnej. Pomimo bardzo wysokiej zmienności stężeń w ściekach dopływających, we wszystkich przypadkach stwierdzono wysoką skuteczność i niezawodność działania instalacji. Średnia efektywność usuwania zanieczyszczeń organicznych i zawiesiny ogólnej wyniosła 94,23% BZT5, 82,55% ChZT oraz 76% zawiesiny ogólnej i była dodatnio skorelowana z obciążeniem tymi parametrami ścieków surowych.
In this paper the analysis of „Lemna” municipal treatment plant performance is reported, the study covered a period of seven years (2009–2015). The efficiency of removal of such indicators as BOD5, COD and total suspended solids were examined. Despite the very high variability of concentrations in raw wastewater, high efficiency and reliability of the installation was found in all cases. The average removal efficiency of organic compounds and total solids was 94.23% for BOD5, 82.55% for COD and 76% for total suspended solids; moreover, it was positively correlated with the load on these parameters in inflow.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 5; 10-17
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie pracy bioreaktora typu SBR za pomocą symulatora GPS-X
SBR bioreactor modelling with the GPS-X simulator
Autorzy:
Jaromin-Gleń, K. M.
Piotrowicz, A.
Łagód, G.
Powiązania:
https://bibliotekanauki.pl/articles/126996.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
reaktor typu SBR
ścieki komunalne
sprawność oczyszczania ścieków
modelowanie
GPS-X
SBR reactor
municipal sewage
treatment efficiency
modelling
Opis:
Najistotniejsze z punktu widzenia eksploatatorów oczyszczalni ścieków jest uzyskanie maksymalnej skuteczności oczyszczania przy jak najniższych nakładach finansowych. Współcześnie w dążeniu do takiego celu pomocne stają się programy komputerowe pracujące w oparciu o modele matematyczne odzwierciedlające kinetykę i stechiometrię procesów oczyszczania ścieków. Opracowanie modelu istniejącej w rzeczywistości oczyszczalni umożliwia wprowadzenie do pierwotnej technologii i przetestowanie różnych modyfikacji przy niewielkich nakładach finansowych i bez ryzyka wprowadzenia zaburzeń w realnie działających urządzeniach. Takie podejście do tematu pozwala zaoszczędzić czas i pieniądze, a co najważniejsze nie wpływa negatywnie na środowisko naturalne. W pracy wykorzystany został program komputerowy GPS-X firmy Hydromantis (wersja 5.0), bazowym modelem matematycznym do opisu procesów realizowanych metodą osadu czynnego był model ASM2d. W ramach opracowania przedstawiono model komputerowy wykonany w oparciu o reaktor typu SBR (Sequencing Batch Reactor), pracujący w warunkach laboratoryjnych, oraz wyniki symulacji procesów oczyszczania ścieków miejskich przeprowadzonych przy jego wykorzystaniu. Zaprezentowano także uzyskane wartości rzeczywistej i modelowanej sprawności oczyszczania ścieków miejskich w nawiązaniu do obowiązujących wymogów prawnych.
The most important issue from the point of view of the WWTP operator is to obtain the highest efficiency of treatment with the lowest financial outlays. At present, the achievement of such a goal can be aided by computer programs that make use of mathematical models which reflect the kinetics and the stoichiometry of wastewater treatment processes. Constructing the model of an existing WWTP makes it possible to introduce to the present technology and examine many modifications that do not require great financial costs and do not cause disturbances in the on-going processes. Such an approach allows saving both time and money, and what is more important, it does not have negative influence on the natural environment. In the research the GPS-X software package was used and for the description of the processes involving activated sludge method the ASM2d model was applied. Within the study was presented the computer model approximating the operation of the SBR type reactor together with the results of the simulation concerning municipal sewage treatment processes. The real and the modelled treatment efficiency values with reference to the mandatory legal regulations were also shown.
Źródło:
Proceedings of ECOpole; 2014, 8, 1; 173-179
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych makrofitów na skuteczność oczyszczania ścieków w stokowych złożach filtracyjnych gruntowo-roślinnych
Influence of selected macrophytes on sewage treatment effectiveness in the slope soil-vegetation filtration beds
Autorzy:
Jucherski, A.
Walczowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/239182.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnia hydrofitowa
stokowe złoże gruntowo-roślinne
skuteczność oczyszczania ścieków
makrofity
constructed wetland
slope soil-vegetation bed
sewage treatment efficiency
macrophytes
Opis:
Celem wieloletnich badań była ocena wpływu monokulturowych nasadzeń manny mielec (Glyceria maxima (Hartm.) Holmb.), mozgi trzcinowatej (Phalaris arundinacea L.) i trzciny pospolitej (Phragmites australis) na skuteczność oczyszczania ścieków bytowych w poletkowych segmentach złóż filtracyjnych oraz wybór rośliny najbardziej przydatnej do stosowania na stokowych złożach gruntowo-roślinnych, opracowanych w GCB w Tyliczu. Manna mielec wykazała najlepszą kondycję botaniczną, dobre wskaźniki ewapotranspiracji (7,9 dm3*m-2*d-1) oraz najlepszą średnią wieloletnią skuteczność oczyszczania ścieków, zarówno w składnikach biogennych zanieczyszczeń (92,9% - Ncałk. i 87,4% - P-PO4), jak i we wskaźnikach BZT5 (90,6%) i ChZT (87,9%). Trzcina, ze względu na nadmierną ekspansję korzeniową, stwarza niebezpieczeństwo zagęszczania i wypierania mineralnych składników złóż, natomiast mozga trzcinowata jest mało stabilna pod względem kondycji biologicznej, a jej wpływ na skuteczność oczyszczania ścieków w złożu najmniejszy.
The aim of presented long-term research was to evaluate the influence of particular monocultures: reedgrass (Glyceria maxima Hartm.), reed Canary grass (Phalaris arundinacea L.) and common reed (Phragmites australis), on the effectiveness of household sewage treatment in the plot segments of filtration beds, and to select the most useful plant to be cultivated on slope type soil-vegetation filter beds (constructed wetland) of theTylicz system. The plot overgrown with reed grass showed the best botanical condition, good evapotranspiration rate (7.9 dm3*m-2 per day) and the highest long-term average effectiveness of sewage treatment, both in nutrient components (92.9% Ntot. and 87.4% P-PO4), as well as BOD (90.6%) and COD (87.9%) rates. The common reed, because of its exaggerated root proliferation, creates a danger of thickening and replacing mineral components of the bed. On the other hand, the reed canary grass is biologically unstable and its influence on the effectiveness of sewage treatment in constructed wetland proved to be the least.
Źródło:
Problemy Inżynierii Rolniczej; 2012, R. 20, nr 1, 1; 115-124
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany w usuwaniu biogenów ze ścieków bytowo-gospodarczych po wieloletniej eksploatacji oczyszczalni roślinno-glebowej
Changes in nutrient removal from domestic sewage after 7 years exploitation of a plant-soil treatment plant
Autorzy:
Kuczewski, K.
Kwiecińska, K.
Kozdraś, M.
Powiązania:
https://bibliotekanauki.pl/articles/338947.pdf
Data publikacji:
2004
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
azot amonowy
azot ogólny
BZT5
efekt oczyszczania
eksploatacja
fosfor
ammonium nitrogen
BOD5
exploitation
total nitrogen
total phosphorus
treatment efficiency
Opis:
W artykule przedstawiono zmiany skuteczności oczyszczania ścieków bytowo-gospodarczych po siedmiu latach eksploatacji oczyszczalni roślinno-glebowej, przeznaczonej do oczyszczania ścieków pochodzących ze wsi Brzeźno. Budowa i zasada pracy tej oczyszczalni różni się istotnie od oczyszczalni roślinno-gruntowych. W artykule przedstawiono efekty oczyszczania, które uzyskano po oddaniu jej do eksploatacji, w rozbiciu na okres zimowy i letni, oraz po siedmiu latach pracy. Analizie poddano następujące wskaźniki zanieczyszczeń: BZT5, stężenie azotu amonowego, azotu ogólnego oraz fosforu. Z badań wynika, że średnia skuteczność oczyszczania ścieków po siedmiu latach eksploatacji oczyszczalni, uwzględniająca okres zimowy i letni, wynosi: BZT5 - ponad 99%, fosforu - 97,3%, azotu ogólnego - 95,9%, a azotu amonowego - 99,5%. Średnia zawartość fosforu w ściekach oczyszczonych w latach 2002-2003 wyniosła 0,3 mg P·dm-³, azotu ogólnego - 4,8 mg N·dm-³, a azotu amonowego - 0,3 mgNNH4·dm-³.
The article shows changes in the efficiency of domestic sewage treatment after 7 years exploitation of a plant-soil treatment plant. The plant purifies domestic sewage from the village Brzeźno. The construction and operation principles of the plant-soil treatment plant differ markedly from constructed wetlands. The paper shows results of operation in the winter and summer periods after 7 years exploitation. Analysed parameters included: BOD5, ammonium nitrogen, total nitrogen and total phosphorus. The studies show that the mean sewage treatment efficiency amounts 99% for BOD5, 97.3% for total phosphorus, 95.9% for total nitrogen and 99.5% for ammonium nitrogen. Mean concentrations of total phosphorus, total nitrogen and ammonium nitrogen in treated sewage in the years 2002-2003 were 0.3 mg·dm-³, 4.8 mg·dm-³ and 0.3 mg·dm-³, respectively.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2004, T. 4, z. 2a; 547-557
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operating household wastewater treatment plants in the light of binding quality standards for wastewater discharged to water bodies or to soil
Użytkowanie przydomowych oczyszczalni ścieków w świetle obowiązujących standardów jakości ścieków odprowadzanych do wód lub do ziemi
Autorzy:
Jawecki, B.
Pawęska, K.
Sobota, M.
Powiązania:
https://bibliotekanauki.pl/articles/946891.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
administrative decision
agglomeration
household wastewater treatment plant
sanitary sewage
stopping the operation of installation
wastewater treatment efficiency
aglomeracja
decyzja administracyjna
kanalizacja sanitarna
przydomowa oczyszczalnia ścieków
skuteczność oczyszczania ścieków
wstrzymanie eksploatacji instalacji
Opis:
The study presents the legal requirements concerning the quality of wastewater discharged to waterbodies and to soil after treatment in household wastewater treatment plants located in agglomerations or outside them. The procedure of stopping the operation of a household treatment plant that doesn't meet the statutory wastewater treatment efficiency was presented. The decision ordering to stop the use of a household wastewater treatment plant has to be preceded by a decision ordering to take measures to limit its adverse impact on the environment. The clarification procedure has to determine the adverse impact on the environment in a doubtless manner and it has to be reflected in the documentation. The assessment of adverse impact should take into account the binding standards of use of the environment. Stopping the operation of a household wastewater treatment plant may result in issuing a decision ordering the user to connect to the sanitary sewage system.
W pracy przedstawiono wymogi prawne, dotyczące jakości ścieków wprowadzanych do wód i do ziemi po oczyszczeniu w przydomowych oczyszczalniach ścieków zlokalizowanych na terenie aglomeracji lub poza nią. Wskazano procedurę wstrzymania eksploatacji przydomowej oczyszczalni ścieków, w sytuacji gdy nie spełnia ona wymaganej przepisami skuteczności oczyszczania ścieków. Decyzja o wstrzymaniu eksploatacji przydomowej oczyszczalni ścieków musi być poprzedzona decyzją nakazującą ograniczenie negatywnego oddziaływania przydomowej oczyszczalni ścieków na środowisko. Postępowanie wyjaśniające negatywne oddziaływanie na środowisko musi zostać stwierdzone w sposób niebudzący wątpliwości oraz znajdować odzwierciedlenie w dokumentacji postępowania, a ocena negatywnego oddziaływania na środowisko powinna uwzględniać obowiązujące standardy korzystania ze środowiska. Konsekwencją wstrzymania eksploatowanej przydomowej oczyszczalni może być wydanie decyzji nakazującej podłączenie się do kanalizacji sanitarnej.
Źródło:
Journal of Water and Land Development; 2017, 32; 31-39
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skutecznosc oczyszczania sciekow w systemach hydrofitowych na przykladzie zloz trzcinowych z przeplywem poziomym
The efficiency of wastewater treatment in horizontal subsurface flow constructed wetlands
Autorzy:
Karczmarczyk, A
Mosiej, J.
Powiązania:
https://bibliotekanauki.pl/articles/40453.pdf
Data publikacji:
2007
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
oczyszczalnie hydrofitowe
przeplyw poziomy
biologiczne oczyszczanie sciekow
zloza gruntowo-roslinne
materialy filtracyjne
efektywnosc oczyszczania
scieki bytowe
hydrophyte treatment plant
horizontal flow
biological sewage treatment
soil-plant deposit
filtration material
sewage treatment efficiency
household sewage
Źródło:
Acta Scientiarum Polonorum. Architectura; 2007, 06, 4; 79-87
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the sewage treatment system of the Silesian agglomeration
Analiza systemu oczyszczania ścieków miasta aglomeracji Śląskiej
Autorzy:
Stankowska, P.
Standera, J.
Kwiatkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/127491.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wastewater treatment plant
efficiency of wastewater treatment technology
oczyszczalnia ścieków
skuteczność technologii oczyszczania ścieków
Opis:
The construction of the technological treatment plant is closely related to the amount and physicochemical parameters of incoming sewage. The economic aspects and the principles of sustainable development also should be taken into account at the stage of sewage treatment plant construction planning. Moreover, in large cities, there is often greater number of sewage treatment plants, which should create an effective system for wastewater treatment. Municipal wastewater treatment system should not disturb the ecological balance of the area and cannot contribute to the deterioration of the living conditions of people (especially those living in the immediate vicinity of the sewage treatment plant). The paper compares the process lines of three wastewater treatment plants located in the city of Bytom: “Centralna” plant, “Miechowice” plant and “Bobrek” plant. The paper also compares the main indicators of the efficiency of the described wastewater treatment plants and the selected parameters of the sewage sludge. Based on the above data, an attempt was made to assess the proper operation of the sewage treatment system in the city of Bytom.
Budowa ciągu technologicznego oczyszczalni jest ściśle powiązana z ilością i parametrami fizykochemicznymi dopływających ścieków. Na etapie planowania należy rozważyć także kryteria zrównoważonego rozwoju oraz aspekty ekonomiczne. Ponadto, w dużych miastach na skuteczny system oczyszczania ścieków składa się często większa liczba oczyszczalni. Miejski system oczyszczania ścieków nie może zakłócać równowagi ekosystemowej danego obszaru ani przyczyniać się do pogorszenia warunków bytowania ludzi (szczególnie tych mieszkających w bezpośrednim sąsiedztwie oczyszczalni ścieków). W artykule porównano ciągi technologiczne trzech oczyszczalni ścieków znajdujących się na terenie miasta Bytom: Oczyszczalni „Centralna”, Oczyszczalni „Miechowice” oraz Oczyszczalni „Bobrek”. Zestawiono także główne wskaźniki efektywności oczyszczania oraz niektóre parametry osadu czynnego. Na podstawie powyższych danych podjęto próbę oceny prawidłowego funkcjonowania systemu oczyszczania ścieków w Bytomiu.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 511-516
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ścieków przemysłowych na energochłonność i efektywność procesów technologicznych w komunalnej oczyszczalni ścieków
The Influence of Industrial Wastewater on the Energy Consumption and the Efficiency of Technological Processes in Municipal Wastewater Treatment Plant
Autorzy:
Remiszewska-Skwarek, A.
Fudala-Książek, S.
Łuczkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818027.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków komunalnych
efektywność oczyszczania
ścieki przemysłowe
treatment of municipal wastewater
efficiency of treatment
industrial wastewater
Opis:
In recent years, the municipal WWTP operated by PEWIK Gdynia receives increasing quantity of industrial wastewater with COD/BOD ratio above 2. In most cases, it is probably due to the required reduction of certain pollutants before delivery of industrial wastewater to the sewage system. Implemented pre-treatment of industrial wastewater by on-site plants usually remove the nutrients and easily biodegradable organic matter, while other organic fractions are directed to the municipal WWTP. In this study the influence of industrial wastewater on the efficiency of technological processes was analyzed on the basis of WWTP in Gdynia-Debogorze. For this reason, the COD fractions (readily (soluble) and slowly (particulate) biodegradable fraction, and non-biodegradable soluble (inert) and particulate fraction) were analyzed in raw wastewater. Obtained results were discussed in terms of the efficiency of treatment processes as well as the energy consumption and the operating costs of the plant.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 110-121
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of wastewater treatment efficiency in Wolbrom
Autorzy:
Gawron, M.
Łukasiewicz, M.
Malinowski, M.
Salamon, J.
Powiązania:
https://bibliotekanauki.pl/articles/101059.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
wastewater treatment plant
efficiency
wastewater treatment
Opis:
The study was conducted to assess the effectiveness of wastewater treatment at the municipal wastewater treatment plant in Wolbrom, to which predominantly domestic wastewater and industrial sewage flow. The assessment was made based on the analysis of the physical and chemical research results of raw and treated wastewater. The research was carried out in the period from January 2014 to December 2014. To perform the analysis of the treatment plant efficiency, four indicators of wastewater pollutants such as BOD5 , COD, total nitrogen and total phosphorus were selected for further investigation. For each of the indicators degrees of reduction and coefficients of treatment plant operational reliability were calculated. The calculated degrees of reduction for each of the indicators were high and amounted to 99.0% for BOD5 , 95.2% for COD, 91.0% for total nitrogen and 91.6%. for total phosphorus. These results prove the effective reduction in the amount of pollutants. The determined coefficients of treatment plant operational reliability were at a low level: BOD5 - 0.27, COD - 0.44, total nitrogen - 0.33 and total phosphorus - 0.53. The conducted analyses prove the effective operation of the treatment plant, which was confirmed by high efficiency of pollutants removal.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/4; 1889-1897
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności pracy oczyszczalni ścieków w Gryfinie
Efficiency of sewage treatment plant in Gryfino
Autorzy:
Szczerbińska, N.
Gałczyńska, M.
Ulas, K.
Burczyk, P.
Mikołajczak, M.
Buśko, M.
Powiązania:
https://bibliotekanauki.pl/articles/339125.pdf
Data publikacji:
2018
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
efektywność oczyszczania ścieków
oczyszczalnia ścieków
ścieki oczyszczone
ścieki surowe
efficiency of wastewater treatment purified sewage
raw sewage
sewage treatment plant
Opis:
Polska – wchodząc w struktury Unii Europejskiej – zobowiązała się do uporządkowania gospodarki ściekowej do końca 2015 r. Dzięki prawidłowej pracy oczyszczalni ścieki odprowadzane do wód odbiornika nie stanowią dla nich zagrożenia. Jest to szczególnie ważne ze względu na potrzebę utrzymania dobrego stanu wód powierzchniowych. Celem badań było określenie efektywności oczyszczania ścieków przez mechaniczno-biologiczną oczyszczalnię ścieków w Gryfinie na podstawie analizy ilości zanieczyszczeń niesionych wraz ze ściekami komunalnymi. Badania przeprowadzono na terenie oczyszczalni ścieków w Gryfinie. Analizy składu ścieków surowych i oczyszczonych obejmowały pięcioletni okres – od 2011 do 2015 r. Analizowano BZT5, ChZT, zawiesinę ogólną, Nog i Pog. Obliczono efektywność pracy oczyszczalni ścieków, skuteczność zmniejszania zanieczyszczeń i wskaźnik technologicznej sprawności oczyszczania. Wyniki badań opracowano statystycznie. Stwierdzono, że średni wskaźnik sprawności oczyszczania ścieków w odniesieniu do zawiesiny ogólnej wyniósł 98,0%, BZT5 – na poziomie 98,9%, natomiast ChZT – na poziomie 97,4%. Średni wskaźnik sprawności oczyszczania ścieków w odniesieniu do azotu ogólnego oraz fosforu ogólnego wyniósł odpowiednio 89,6% i 96,4%. Ustalono, że efektywność oczyszczalnia ścieków w Gryfinie była bardzo duża i zgodna z przepisami.
Poland entering the structures of the European Union committed itself to organize wastewater management by the end of 2015. Due to the correct operation of the sewage treatment plant, the sewage discharged into the receiver water does not pose any danger to them. This is especially important because of the need to maintain good surface water quality. The aim of the study was to analyse the amount of pollutants transported with municipal wastewater, to determine the efficiency of wastewater treatment by mechanical-biological sewage treatment plant in Gryfino. The research was carried out on the sewage treatment plant in Gryfino. Analyses of raw and purified wastewater were carried on a five year period from 2011 to 2015. BOD5, COD, general suspension, total nitrogen and total phosphorus were analyzed. The efficiency of sewage treatment plant operation, efficiency of pollution reduction and the technological wastewater treatment efficiency rate were calculated. The results of the research were statistically analyzed. It was found that the average wastewater treatment efficiency rate for the total suspended solids was 98.0%, and BOD5 – 98.9%, and COD – 97.4%. The average efficiency index of wastewater treatment for total nitrogen and total phosphorus was 89.6% and 96.4% respectively. It was found that the efficiency of the wastewater treatment plant in Gryfino was very good and consistent with the regulations.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2018, 18, 2; 85-98
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies