Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "transmission line method" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Modeling of frequency response of transformer winding with axial deformations
Autorzy:
Gawrylczyk, K. M.
Banaszak, S.
Powiązania:
https://bibliotekanauki.pl/articles/140733.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
transformer
winding
frequency response analysis (FRA)
lumped parameters method
transmission line method
Opis:
One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows to determine the mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. Still pending problem is interpretation of measurements results. One of approaches is application of computer modeling to simulate various failure modes and connected with them changes in FRA response. The paper presents two types of models, one based on lumped parameters with RLC elements, and one based on distributed parameters with TLM method. Both methods give similar results, comparable to real measurements of simulated coil.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 5-17
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the impact of 220 kV SISFCL on the distance protection for transmission line
Autorzy:
Luo, Y.
Shi, T.
Huang, L.
Powiązania:
https://bibliotekanauki.pl/articles/141728.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
SISFCL
distance protection
EMTDC/PSCAD
220 kV transmission line
setting method
Opis:
As the most typical application of superconducting technology, the Saturated Iron core Superconducting Fault Current Limiter (SISFCL) is a kind of ideal high voltage limiter, which can achieve noticeable limiting endless stream and has wide application prospect. However, the selectivity and sensitivity of the distance protection (DP) in the high voltage transmission network would be affected by the impedance characteristics of SISFCL. For these problems, firstly the structure and the working principle of the SISFCL are introduced briefly. Secondly, the impact mechanisms of 220 kV SISFCL on the original distance protection for the transmission line (TL) are analyzed. Then two methods of eliminating influences are deduced from the previous analysis and an improved setting method based on SISFCL for distance protection is proposed. Finally, we used EMTDC/PSCAD software to build the 220 kV SISFCL and distance protection model in the transmission network. The simulation results demonstrate that the proposed setting strategy can effectively improve the selectivity and sensitivity of distance protection and provide a reference for the practical applications of SISFCL applied to the transmission line.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 151-163
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies