Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "transmission coefficient" wg kryterium: Temat


Wyświetlanie 1-15 z 15
Tytuł:
Real time quantum tunneling
Autorzy:
Papadopoulos, G. J.
Powiązania:
https://bibliotekanauki.pl/articles/1940711.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska
Tematy:
quantum tunneling
square barrier propagator
transmission coefficient
Opis:
The time evolution of the probability and current densities stemming from an initial tate of a particle in the form of a wave packet on the left hand side of a square barrier is studied. In particular, the space distribution at a given time of the above densities is given. Furthermore, the evolution in time at the entrance and exit of the barrier is given. The numerical results show repeated reversal in the current density at the barrier entrance, while being unidirectional at the exit. However, the probability entering the barrier over a long time equals the corresponding probability exiting the barrier. Owing to the fact that the wave packet expands on both of its sides, as time goes by, it is possible to have transmission even if the particle’s initial momentum points away from the barrier. The effect, in question, becomes evident in a diagram for the transmission coefficient in terms of the particle initial momentum, over a relatively small region.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2015, 19, 1; 65-74
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tunneling throught a barrier under transverse magnetic field and I-V characteristic
Autorzy:
Papadopoulos, George J.
Powiązania:
https://bibliotekanauki.pl/articles/1955281.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska
Tematy:
transmission coefficient
momentum-like quantity
I-V characteristic
Opis:
The case whereby the transmission coefficient through a barrier, sandwiched by semiconductor reservoirs, under bias is provided by a general formula involving the logarith micwave function derivative at the barrier entrance is now extended to include the influence of magnetic field perpendicular to the longitudinal barrier direction. Under the circumstances, theequation governing the logarithmic wave function derivative is appropriately modified via aneffective potential energy which takes account of the magnetic field. Subsequently, the procedurefor obtaining the transmission coefficient is applied to the case involving a smooth double, as wellas quadruple, barrier for which theI-V characteristic is obtained. The results show reduction incurrent with increase in the magnetic field, up to a certain value of bias. Furthermore, increasein temperature exhibits increase in current as well as movement of the current peaks in the I-V curves towards lower bias.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2018, 22, 2; 125-133
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametric comparison of rectangular and circular pontoons performance as floating breakwater numerically
Autorzy:
Tabatabaei, S. M. R.
Zeraatgar, H.
Powiązania:
https://bibliotekanauki.pl/articles/260165.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Floating Breakwater
transmission coefficient
circular section
rectangular section
Opis:
Rectangular and circular pontoons are one of the most widely cross-sections used as floating breakwaters (FB). Although, there are several articles on comparison of behavior of rectangular and circular floating breakwaters however, the Authors try to show some details of difference between these two types where they have not been addressed before. To do so, transmission coefficient (Ct), as a measure of merit, of similar rectangular and circular sections is numerically compared. A computer code is developed for two-dimensional hydrodynamic analysis of floating breakwater based on diffraction theory in frequency domain in regular waves with any configuration of mooring line. The numerical method is the finite element method and validated by comparing with experimental and numerical results. Three types of rectangular sections are defined equivalent to circular section and a numerical comparison is made between 100 similar sections. The Ct versus wave frequency has been considered in detail and three new points called LMinF, LMaxF and LMaxCt are introduced. It has been shown that LMinF and LMaxF of circular section are greater and LMaxCt is much smaller than equivalent rectangular section. The LMaxCt of both sections are very dependent to new nondimensional parameter B/D (Breadth/Draft). Although, rectangular sections are more common for floating breakwater, however the results of this study show that possibility of using circular sections must be also considered.
Źródło:
Polish Maritime Research; 2018, S 1; 94-103
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New Textiles Designed for Anti-Radar Camouflage
Nowe konstrukcje włókiennicze maskujące przeciwradiolokacyjnie
Autorzy:
Redlich, G.
Obersztyn, E.
Olejnik, M
Fortuniak, K
Bartczak, A
Szugajew, L
Jarzemski, J.
Powiązania:
https://bibliotekanauki.pl/articles/232241.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
woven fabric
knitted fabric
anti-radar camouflage
reflection coefficient
transmission coefficient
time domain
microwave measurements
tkaniny
dzianiny
kamuflaż anty-radar
współczynnik odbicia
współczynnik transmisji
pomiary mikrofalowe
Opis:
This paper presents newly designed textiles (woven and knitted fabrics) for camouflage against radar, with a particular emphasis on the conductive yarns applied and their distribution throughout the structure of the goods. The levels obtained for the coefficients of re- flection and the transmission of electromagnetic waves have been discussed for woven and knitted fabrics, both raw and those subjected to finishing treatment. These parameters were determined using two methods: waveguide applicators and in the space in a semi-anechoic chamber within the time domain. The issues this publication covers are an integral part of research on developing textile products featuring a broad spectrum of masking, i.e. within the visible (VIS), near infrared (IR), and that of the subject - the anti-radar band. The first two types of camouflage were discussed in an earlier publication entitled “Assessment and Verification of the Functionality of New, Multi-component, Camouflage Materials” (Fibres & Textiles in Eastern Europe 2013; 21, 5(101): 73-79).
W artykule przedstawiono nowoopracowane konstrukcje włókiennicze (tkaniny, dzianiny) maskujące przeciwradiolokacyjnie, ze szczególnym uwzględnieniem zastosowanych przędz konduktywnych oraz ich rozkładu w strukturze wyrobów. Omówiono poziomy uzyskanych wartości współczynników odbicia i transmisji fal elektromagnetycznych, zarówno dla tkanin i dzianin surowych, jak i poddanych obróbce wykańczalniczej. Parametry te były wyznaczane z zastosowaniem dwóch metod tj. z wykorzystaniem aplikatorów falowodowych oraz w przestrzeni w komorze bezechowej w domenie czasu. Zagadnienia ujęte w niniejszej publikacji stanowią integralną część badań nad opracowaniem wyrobów włókienniczych o szerokim spektrum maskowania, tj. w zakresie widzialnym (VIS), bliskiej podczerwieni (IR) oraz przedmiotowym czyli przeciwradiolokacyjnym. Dwa pierwsze rodzaje maskowania zostały przedstawione we wcześniejszej publikacji pt. „Assessment and verification of functionality of new, multi-component, masking materials ”(Fibres & Textiles in Eastern Europe 2013; 21, 5(101): 73-79).
Źródło:
Fibres & Textiles in Eastern Europe; 2014, 1 (103); 34-42
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nachylenia okien i szyb zespolonych na współczynnik przenikania ciepła
Influence of inclination of windows and insulation glass units on thermal transmittance
Autorzy:
Owczarek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/183082.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniki Budowlanej
Tematy:
okno
szyba zespolona
nachylenie
izolacyjność cieplna
współczynnik przenikania ciepła
program numeryczny
wyniki badań
window
double glazing panel
inclination
thermal insulating properties
thermal transmission coefficient
numerical calculations
tests results
Opis:
Odchylenie okien i szyb zespolonych od pozycji pionowej pogarsza ich izolacyjność cieplną (współczynnik przenikania ciepła Ug i Uw). Ponieważ laboratoria zwykle są wyposażone w aparaturę umożliwiającą badanie szyb i okien usytuowanych w pozycji pionowej, dlatego w niniejszym artykule zaproponowano prosty sposób obliczania projektowej wartości współczynnika przenikania ciepła przez okna nachylone do poziomu pod kątem innym niż 90°. Sposób ten opracowano na podstawie wyników badań i obliczeń współczynnika przenikania ciepła przez szyby jedno- i dwukomorowe.
Deviation of windows and insulation glass units from vertical position causes deterioration of their thermal insulation (thermal transmittance Ug and Uw). Because laboratories are usually equipped — with apparatus for testing glazing and windows in vertical position, therefore in this paper, the simplified method of calculation of design thermal transmittance (Uw - value) of windows inclined to the level at other angle than 90° was proposed. This method was based on the results of tests and calculations of thermal transmittance for double and triple glazing.
Źródło:
Prace Instytutu Techniki Budowlanej; 2009, R. 38, nr 2, 2; 3-22
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu punktowych mostków cieplnych na izolacyjność cieplną systemu ETICS
Analysis of the impact of point losses on ETICS system thermal insulating capacity
Autorzy:
Ujma, A.
Powiązania:
https://bibliotekanauki.pl/articles/2068379.pdf
Data publikacji:
2011
Wydawca:
Politechnika Częstochowska
Tematy:
konstrukcja budowlana
współczynnik U
współczynnik przenikania ciepła
ściana zewnętrzna
izolacja cieplna
izolacja zewnętrzna
izolacja termiczna
system zewnętrznej kompozytowej izolacji cieplnej
ETICS
building construction
U-factor
heat transmission coefficient
thermal insulation
external wall
external insulation
external thermal insulation composite system
Opis:
Niską wartość współczynnika U, czyli współczynnika przenikania ciepła ścian lub innych przegród zewnętrznych budynków można osiągnąć, stosując zewnętrzną izolację cieplną - External Thermal Insulation Composite System (ETICS). Niniejszy artykuł przedstawia analizę wpływu punktowych mostków cieplnych na izolacyjność cieplną systemu ETICS. Grubość izolacji i ilość punktowych mostków cieplnych może istotnie wpłynąć na izolacyjność cieplną konstrukcji budowlanej.
Low U-factor or coefficient of heat transmission for walls or other of building construction can be achieved using external insulation - External Thermal Insulation Composite System (ETICS). This paper presents analysis of the impact thermal point losses in the system ETICS of the heat thermal insulation. The thickness of the insulation and the quantity of thermal point losses may materially affect the insulation capacity thermal of building construction.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2011, 17 (167); 202-216
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielkość okien a bilans cieplny pomieszczenia
Window size and the thermal balance of rooms
Autorzy:
Grudzińska, M.
Powiązania:
https://bibliotekanauki.pl/articles/161270.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
powierzchnia okien
bilans cieplny
zysk cieplny
strata ciepła
szyba pojedyncza
szyba podwójna
szyba potrójna
współczynnik przenikania ciepła
transmisyjność promieniowania słonecznego
windows surface area
thermal balance
heat gain
heat loss
single glazing
double glazing
triple glazing
thermal transmission coefficient
solar radiation transmissivity
Opis:
Okna to elementy które w budynku mogą być źródłem strat i zysków ciepła. Wielkość jednych i drugich uzależniona jest od powierzchni okien, ich izolacyjności termicznej i zdolności przepuszczania promieniowania słonecznego. Poprzedni artykuł dotyczył wpływu konstrukcji okien na bilans cieplny przykładowego pomieszczenia mieszkalnego. Poniższa praca uzupełnia analizy o sprawdzenie zależności między powierzchnią okien a energetycznymi właściwościami pomieszczenia.
Windows are elements of a building which may be a source of both heat losses and heat gains. The amount of each is dependent on the size of the windows, their thermal insulating properties, and their capacity to admit solar radiation. A previous article described how window design affects the thermal balance of an example room in a home. This article supplements that analysis by investigating the relationship between the surface area of windows and the energy properties of a room.
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 10, 10; 32-35
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reflected and transmitted powers of electromagnetic waves through a ferrite-dielectric photonic crystal
Autorzy:
Ubeid, M. F.
Shabat, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/411684.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
damping coefficient
electromagnetic waves
frequency
photonic crystal
reflection
transmission
Opis:
In this work, reflection and transmission of electromagnetic wave by a periodic ferrite-dielectric photonic crystal are investigated theoretically and numerically. The ferrite material is described and its main parameters are given in detail. After the construction of the problem, the reflection and transmission coefficients are derived in a closed form by a transfer matrix method. The reflected, transmitted, and loss powers of the crystal are calculated using these coefficients. In the numerical results the mentioned powers are computed and illustrated as a function of frequency, angle of incidence, dielectric thickness, and applied magnetic field intensity when the damping coefficient changes.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 14, 1; 86-98
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-Objective Optimization of Acoustical Properties of PU-Bamboo-Chips Foam Composites
Autorzy:
Jiang, Y.
Chen, S.
Wang, D.
Chen, J.
Powiązania:
https://bibliotekanauki.pl/articles/177709.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vehicle sound package
sound absorption coefficient
transmission loss
Taguchi method
Opis:
In this study, an effective optimization approach was proposed to improve acoustical behaviors of PU foams. The important parameters of PU foams: content of water, silicone oil and catalyst A1 were chosen and their effects on sound absorption coefficient and transmission loss of PU foams were studied by using Taguchi methods. In addition, bamboo chips were incorporated into PU foams as fillers to improve the acoustical properties of PU foams. Four controlled factors: the content of water, silicone oil, catalyst A1 and bamboo chips with three levels for each factor were chosen and Taguchi method based on orthogonal array L9 (34) was employed to conduct the experiments. Based on the results of Taguchi’s orthogonal array L9 (34), signal-to noise (S/N) analysis was used and developed to determine an optimal formulation of PU-bamboo-chips foam composites.
Źródło:
Archives of Acoustics; 2017, 42, 4; 707-714
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment on Gamma Attenuation Behavior of W-VC-C and W-VC-TiC-C Composites for Co-60 Radioisotope
Autorzy:
Demir, E.
Tugrul, A.
Sonmez, S.
Ovecoglu, L.
Buyuk, B.
Yilmaz, O.
Powiązania:
https://bibliotekanauki.pl/articles/1031587.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
attenuation coefficient
Co-60
radiation shielding material
transmission technique
W-VC-C-TiC composite
Opis:
In this study, tungsten-vanadium carbide-graphite (W-VC-C) and tungsten-vanadium carbide-titanium carbide-graphite composite (W-VC-TiC-C) materials were investigated against Co-60 gamma radioisotope. The composite materials which are used in advanced technological studies and high temperature applications in many various fields especially in the areas of fission and fusion armor materials were produced by mechanical alloying method as in two groups. One of them include 93% tungsten (W), 6% vanadium carbide (VC) and 1% graphite (C) also which has three different alloying times (6-12-24 h). Other group of the samples was composed of 91% tungsten, 6% vanadium carbide (VC), 2% titanium carbide (TiC) and 1% graphite (C) also which has three different alloying times (6-12-24 h) and sintered at 1750°C. Co-60 gamma radioisotope source and gamma transmission technique were used in the experiments to investigate the properties of the composite materials. The mass attenuation coefficients of the samples were determined by using experimental results and theoretical mass attenuation coefficients were calculated from XCOM computer code. It can be concluded that increasing the tungsten ratio causes higher mass attenuation coefficient and the composite materials have provided us benefits better than lead for radiation gamma shielding.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 830-832
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of the acoustic properties of granular materials determined with the use of impedance tube
Autorzy:
Kosała, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/24202011.pdf
Data publikacji:
2022
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
granular materials
sound absorption coefficient
sound transmission loss
materiały ziarniste
współczynnik pochłaniania dźwięków
strata transmisji dźwięku
Opis:
The results of acoustic property tests for six types of granular materials: perlite, vermiculite, active coconut carbon, rubber granulates, pumice and wood chips, which can be used in noise protection structures, are shown in the article. The characteristics of the normal incidence sound absorption coefficient and the normal incidence sound transmission loss for material specimens with seven thicknesses in the range of 10-100 mm were determined based on the results of experimental tests carried out with the use of an impedance tube. The relationships between the first resonant absorption frequencies and the thicknesses of material specimens were determined. Single-number indices for the tested materials, in the form of the weighted sound absorption coefficients, were determined. Subsequently, dependencies of these indices on the surface mass of the tested materials were determined. The research showed that three materials, perlite, vermiculite and active coconut carbon, were distinguished among the examined granules with the best sound-absorbing and sound-insulating properties. Active coconut carbon had the best sound-insulating properties among the granular materials tested.
Źródło:
Vibrations in Physical Systems; 2022, 33, 3; art. no. 2022321
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novye principy proektirovania i ocenki naruznych ograzdauscich konstrukcij s ispol’zovaniem rekuperacii tepla i drugich technologij „aktivnogo” energosberezenia
The new principles of design and assessment of external envelopes with use of heat recuperation and other technologies of “active” energy saving
Autorzy:
Spiridonov, A.
Subin, I.
Achmarov, T.
Powiązania:
https://bibliotekanauki.pl/articles/2065404.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
energooszczędność
odzysk ciepła
rekuperacja ciepła
energy efficient ventilated envelopes
system of active energy saving
recovery of transmission heat
coefficient of reduction of a thermal stream
recovery coefficient
Opis:
V stat’e rassmotren principial’no novyj princip povysenia energeticeskoj effektivnosti naruznych ograzdauscich konstrukcij novogo pokolenia s rekuperaciej tepla, kotoryj mozno ispol’zovat’ v stroitel’nych konstrukciach kak stroascichsa, tak i rekonstruiruemych zdanij. Odnim iz novych perspektivnych resenij v etom napravlenii avlaetsa primenenie energoeffektivnych ventiliruemych ograzdauscich konstrukcij (EVOK) zdanij s sistemoj aktivnogo energosberezenia (SAE) s rekuperaciej tepla, pozvolauscich povysit’ uroven’ teplozascity i komfortnosti mikroklimata pomescenij pri znacitel’noj ekonomii topliwno-energeticeskich resursov. Osnovnoj princip dejstvia sistemy po rekuperacii transmissionnogo tepla (za scet teploperedaci i konvekcii) i radiacionnogo tepla (teplovoe izlucenie) zaklucaetsa v osoboj organizacii uslovij postuplenia potoka naruznogo vozducha i dal’nejsego prochozdenia ego cerez konstrukciu ograzdenia, а takze teplootrazenia s pomosc’u special’nych ekranov (avtonomnych ili v vide pokryvauscich sloev). V vozdusnom promezutke, na vchode vozdusnogo potoka, sozdaetsa ploskaa vozduznaa zavesa iz cholodnogo postupauscego vozducha, maksimal’no ochlazdauscaa poverchnosti, sloi, teplootrazauscie ekrany i gibkie svazi, kotorye peredaut teplo v atmosferu. Dla ocenki predlagaemych konstrukcij EVOK predlozeny (dopolnitel’no k suscestvuuscim) esce dva pokazatela – koefficient umen’senia teplovogo potoka i koefficient rekuperacii.
In the article essentially new principle of increase of energy efficiency of external envelopes of new generation with heat recovery, which can be used in construction designs both under construction and reconstructed buildings, is considered. One of new perspective decisions in this direction is application of the energy effective ventilated envelopes (EEVE) of buildings with the system of active energy saving (SAES) with recovery of heat, allowing to raise level of heat-shielding and comfort of microclimate of rooms at considerable economy of fuel and energy resources. The basic principle of action of system on recovery of transmission heat (at the expense of a heat transfer and convection) and radiation heat (thermal radiation) consists in the special organization of conditions of receipt of a stream of external air and its further passing through an envelope, and also heat reflections by means of special screens (autonomous or in the form of covering layers). In an air interval, on an entrance of an air stream, the flat air veil from the cold arriving air, most cooling surfaces, the layers heat reflecting screens and flexible communications, which transfer heat to the atmosphere is created. For an assessment of offered designs of EEVE two more indicators - coefficient of reduction of a thermal stream and recovery coefficient are offered (in addition to existing).
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 2 (16); 84--94
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studying the influence of selected controlled factors on the coefficient of sliding friction through experimental planning metho
Badanie wpływu wybranych kontrolowanych czynników na współczynnik tarcia ślizgowego za pomocą eksperymentalnych metod planowania
Autorzy:
Ahmedov, Beyali
Aslanov, Zabit
Powiązania:
https://bibliotekanauki.pl/articles/31348316.pdf
Data publikacji:
2024
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
pumping unit
transmission
sliding bearing
coefficient of friction
dispersion
regression
pompa żerdziowa
przekładnia
łożysko ślizgowe
współczynnik tarcia
dyspersja
regresja
Opis:
The article presents the use of mathematical statistics to determine controllable factors that influence the coefficient of friction in a dual-flow three-stage spur gear transmission of a newly designed sucker rod pumping unit. The load acting on the bearing units, the rotational speed of the main and auxiliary shafts, and the diametrical gap between the shaft and the bushing were assessed through tests. The tests were carried out in random order. The multivariate testing was used to determine the number of tests to be performed as well as the test conditions in order to achieve the required accuracy bushing. In the statistical analysis of the results, the Cochrane criterion was applied to verify the homogeneity of the variance values. Student's t-test was used to verify the significance of the coefficients included in the regression equation, Fisher’s F-test was used to determine the suitability of the adopted output function for describing the real object of study, i.e., the adequacy of the model, and sensitivity coefficients were used to assess the influence of the corresponding parameters on the optimization parameter. The analysis also considered the dispersion of optimization parameters, measurement repeatability, and errors in the model coefficients. Experimental values of the criteria, along with the dispersion of the adequacy and repeatability of the mathematical model, were evaluated to determine whether the model is fully suitable for the object of study. The impact of significant factors and their combinations, as well as their critical values, were assessed by comparing calculated values of the criteria. The significance or insignificance of the corresponding coefficients of the regression equation was determined. To investigate the impact of these controlled factors — load, rotational speed of the main and auxiliary shafts, and the diametrical gap between the auxiliary shaft and the bushing — on the sliding friction coefficient, a modernized device was developed. This device simulates the operating conditions of a double friction sliding bearing in a dual-flow, three-stage spur gearbox bushing. The experiments were conducted using I-40A industrial oil at room temperature. It has been determined that these factors significantly impact the coefficient of friction in a double friction bearing. Consequently, it is necessary to calculate their limit values to ensure the bearing assembly operates without failure during the required service life. Compared to other examined parameters, the optimization parameter, i.e., the coefficient of friction, is most significantly influenced by the diametrical gap between the auxiliary shaft and the bushing, and least affected by the magnitude of the load acting on the bearing assembly. The overall impact of controlled factors on the coefficient of friction is minimal. Employing the test planning method, a mathematical formula was derived, enabling the determination of the coefficient of friction in a double sliding friction bearing without additional tests within the range of limit bushing values of contact parameters.
W artykule przedstawiono zastosowanie statystyki matematycznej do określenia sterowalnych czynników wpływających na współczynnik tarcia w podwójnej, trójstopniowej przekładni zębatej czołowej nowo zaprojektowanej pompy żerdziowej. Za pomocą badań oceniono obciążenie działające na zespoły łożyskowe, prędkość obrotową wału głównego i pomocniczego oraz średnicę szczeliny między wałem a tuleją. Badania przeprowadzono w losowej kolejności. Badania wielowariantowe wykorzystano do określenia liczby badań, które należy wykonać, a także warunków badawczych w celu osiągnięcia wymaganej dokładności. W analizie statystycznej wyników zastosowano kryterium Cochrane'a w celu weryfikacji jednorodności wartości wariancji. Test t-Studenta posłużył do weryfikacji istotności współczynników zawartych w równaniu regresji, test F-Fishera wykorzystano do określenia przydatności przyjętej funkcji wyjściowej do opisania rzeczywistego obiektu badań, tj. adekwatności modelu, a współczynniki wrażliwości wykorzystano do oceny wpływu odpowiednich parametrów na parametr optymalizacyjny. W analizie uwzględniono również rozrzut parametrów optymalizacyjnych, powtarzalność pomiarów oraz błędy we współczynnikach modelu. Eksperymentalne wartości kryteriów, wraz z rozproszeniem adekwatności i powtarzalności modelu matematycznego, zostały ocenione w celu ustalenia czy model w pełni spełnia wymagania stawiane obiektowi badań. Wpływ istotnych czynników i ich kombinacji, a także ich wartości krytyczne, oceniono poprzez porównanie obliczonych wartości kryteriów. Określono istotność lub nieistotność odpowiednich współczynników równania regresji. W celu zbadania wpływu tych kontrolowanych czynników – obciążenia, prędkości obrotowej wału głównego i pomocniczego oraz szczeliny średnicowej pomiędzy wałem pomocniczym a tuleją – na współczynnik tarcia ślizgowego, opracowano zmodernizowane urządzenie. Urządzenie to symuluje warunki pracy podwójnego łożyska ślizgowego w podwójnej, trzystopniowej przekładni czołowej. Eksperymenty przeprowadzono przy użyciu oleju przemysłowego I-40A w temperaturze pokojowej. Ustalono, że czynniki te mają znaczący wpływ na współczynnik tarcia w podwójnym łożysku ślizgowym. W związku z tym konieczne jest obliczenie ich wartości granicznych, aby zapewnić bezawaryjną pracę zespołu łożyskowego w wymaganym okresie eksploatacji. W porównaniu z innymi badanymi parametrami, na parametr optymalizacyjny, tj. współczynnik tarcia, największy wpływ ma szczelina średnicowa między wałem pomocniczym a tuleją, a najmniejszy wpływ ma wielkość obciążenia działającego na zespół łożysk. Ogólny wpływ kontrolowanych czynników na współczynnik tarcia jest minimalny. Wykorzystując metodę planowania badań, wyprowadzono wzór matematyczny umożliwiający wyznaczenie współczynnika tarcia w podwójnym ślizgowym łożysku bez dodatkowych badań w zakresie granicznych wartości parametrów styku.
Źródło:
Nafta-Gaz; 2024, 80, 1; 30-38
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental tests of the acoustic properties of sound-absorbing linings and cores of layered baffles
Autorzy:
Kosała, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2146647.pdf
Data publikacji:
2021
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
sound transmission loss
sound absorption coefficient
insertion loss
baffles
mineral wool
izolacyjność akustyczna od dźwięków powietrznych
współczynnik pochłaniania dźwięku
tłumienie przepustowe
przegrody
wełna mineralna
Opis:
The article presents the results of research on the acoustic properties of materials used as sound-absorbing linings and cores in baffles of anti-noise protection. Using an impedance tube the spectral characteristics of the normal incidence sound absorption and sound transmission loss indices of 12 specimens of mineral wool with different density and thickness were determined. From these characteristics, the single-number weighted sound absorption coefficient αw and the sound reduction index Rw were calculated. To calculate the value of the Rw index on the basis of surface mass of the mineral wool specimen, a new formula was proposed. The insertion loss of an acoustic enclosure with one, two and three-layer walls with dimensions of 0.7×0.7 m, containing mineral wool, was determined. The best efficiency was achieved for the enclosure made of walls of layers: mineral wool, placed on the sound source side, steel plate and aluminium plate.
Źródło:
Vibrations in Physical Systems; 2021, 32, 1; art. no. 2021107
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy-efficient combined shock-foam-type air-handling unit with block of thermoelectric modules for air conditioning systems
Energooszczędne urządzenie udarowo-pianowe z blokiem modułów termoelektrycznych dla systemów klimatyzacyjnych
Autorzy:
Chaban, I. V.
Dovgalyuk, V. B.
Powiązania:
https://bibliotekanauki.pl/articles/2065234.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
shock-foam-type air-handling unit
mass aerodynamic drag
number of transfer units
head of foam
static fluid level
coefficient of heat transmission
urządzenie udarowo-pianowe
opór aerodynamiczny
liczba jednostek transferu
warstwa pianki
statyczny poziom płynu
współczynnik przenikania ciepła
Opis:
The paper deals with the heat and mass transfer process research and calculation of the combined shock-foam-type air-handling unit with block of thermoelectric modules that create microclimate parameters during the museum pieces transportation and their storage in special premises. The air conditions variation range in air-handling unit is not limited to contact heating device, by combination of surface and contact heat exchangers in one construction, moreover, turbulence in gas-liquid system provides intensification of the heat and mass transfer processes and air purification from impurities. Furthermore, combined shock-foam-type air-handling unit is compact, lightweight, energy-efficient and makes possible temperature and cooling capacity variable control.
Zaprezentowano wyniki badań i obliczenia połączonego urządzenia udarowo-pianowego z modułami termoelektrycznymi, zapewniającego optymalne parametry środowiska powietrznego zarówno podczas transportu obiektów muzealnych, jak i podczas ich przechowywania w specjalnych pomieszczeniach. Dzięki połączeniu powierzchniowych i kontaktowych wymienników ciepła w jednej konstrukcji zakres zmiany parametrów powietrza nie jest ograniczony do funkcji urządzeń kontaktowych, ponadto turbulencja przepływu gazu i płynu zapewnia intensyfikację procesów ogrzewania i oczyszczanie powietrza z zanieczyszczeń. Dodatkowo to urządzenie jest lekkie, energooszczędne z możliwością regulacji temperatury i mocy chłodniczej.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 1 (15); 41--48
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-15 z 15

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies