Designing of two-voltage power supply systems for 110 kV/medium voltage substations
Projektowanie dwunapięciowych układów zasilania stacji transformatorowych 110 kV/SN
Autorzy:
Bąchorek, W.
Powiązania:
https://bibliotekanauki.pl/articles/172819.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stacja transformatorowa
sieć miejska
sieć elektroenergetyczna
transformer station
urban network
energetics
Opis:
The paper tackles the problems of designing redundancy feeding lines for supplying medium voltage (MV) municipal power networks in the conditions of increased load of 110 kV/MV transformer stations. Designed feeding systems lie in direct MV connections between 110 kV/MV transformer stations. The 110 kV/MV transformers were planned to be replaced and MV switching stations modernized. A mathematical model with an objective function for minimizing the total capital cost of the planned network was worked out. A genetic algorithm was used for solving the optimization task. Exemplary calculations for two power networks, results of analyses and final conclusions close the paper.
Artykuł dotyczy problematyki projektowania układów zasilania rezerwowego dla punktów zasilania miejskich sieci średniego napięcia (SN) w warunkach zwiększonego poziomu obciążenia stacji transformatorowych 110 kV/SN. Projektowane układy zasilania polegają na budowie bezpośrednich połączeń średniego napięcia pomiędzy stacjami transformatorowymi 110 kV/SN. W omawianym zadaniu rozważana jest również wymiana transformatorów 110 kV/SN oraz modernizacja rozdzielni SN. W celu przeprowadzenia badań sporządzono model matematyczny wraz z funkcją celu minimalizującą całkowity koszt inwestycyjny projektowanej struktury sieci. Do rozwiązania zadania optymalizacji zastosowano algorytm genetyczny. W artykule przedstawiono przykłady obliczeniowe dla dwóch sieci elektroenergetycznych, wyniki badań oraz wnioski.
Źródło:
Archiwum Energetyki; 2011, 41, 1; 79-99
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Słupowe stacje transformatorowe dawniej i dziś
Transformer stations on pylon - formerly and today
Autorzy:
Zawodniak, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/163174.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
stacja transformatorowa
stacja słupowa
przegląd
rys historyczny
transformer station
pole mounted transformer
review
historical outline
Opis:
W artykule przedstawiono poszczególne typy słupowych stacji transformatorowych jakie obecnie są eksploatowane w energetyce zawodowej.
In this article are presented a different kinds of transformer stations mounted on pylon, which are exploited at present in professional power industry.
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 6, 6; 55-57
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane rozwiązanie produktowe wpływające na rozwój i kształt sieci elektroenergetycznej SN i nN
Selected product solution influencing the development and design of MV and LV electricity networks
Autorzy:
Juraszek, Janusz
Irauth, Grzegorz
Koziński, Artur
Powiązania:
https://bibliotekanauki.pl/articles/1860956.pdf
Data publikacji:
2021
Wydawca:
Centrum Usług i Projektów Janusz Juraszek
Tematy:
sterowanie
monitoring stacji transformatorowych
stacja SPS
magazyn energii
control
transformer station monitoring
SPS station
energy storage
Opis:
W artykule przedstawiono stację SPS jako produkt odpowiadający na nowe wyzwania i problemy rynku. Dobudowa licznych układów fotowoltaicznych wymaga zabudowy układów magazynowania i zarządzania energią. Stacje abonenckie, dystrybucyjne posiadające możliwość pełnego sterowania, nadzoru i zarządzania przepływem energii, są inteligentnym rozwiązaniem wpisującym się w cyfryzację życia gospodarczego firm.
The article presents the SPS station as a product responding to new challenges and problems in the market. The addition of numerous photovoltaic systems requires the development of energy storage and management systems. Subscriber and distribution stations with the possibility of full control, supervision and management of energy flow, are an intelligent solution that fits into the digitalization of economic life of companies.
Źródło:
Era Energii; 2021, 1; 16-19
2658-0195
Pojawia się w:
Era Energii
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of higher harmonics generation by non-linear loads
Analiza wytwarzania wyzszych harmonicznych przez odbiorniki nieliniowe
Autorzy:
Necka, K.
Powiązania:
https://bibliotekanauki.pl/articles/793595.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
nonlinear load
distortion factor
higher harmonics
oscillogram
low-voltage grid
transformer station
supply voltage
supply current
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obudowy kontenerowych stacji transformatorowych realizowane jako elementy przestrzenne
Cover of transformer station container executed as a spatial elements
Autorzy:
Dekarz, R.
Lipniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/163161.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
stacja transformatorowa
transformator kontenerowy
obudowa monolityczna
prefabrykat przestrzenny
żelbet
transformer station
container transformer
monolithic enclosure
precast spatial element
reinforced concrete
Opis:
W artykule opisano system monolitycznych, żelbetowych konstrukcji przestrzennych przeznaczonych na obudowy kontenerowych stacji transformatorowych i rozdzielni elektrycznych. Podano klasyfikację stacji kontenerowych ze względu na rozmiary obudów. Omówiono niektóre problemy realizacji wielkowymiarowych prefabrykatów przestrzennych i badań ognioodporności obudowy w czasie zwarcia łukowego wewnątrz stacji.
The article describes a system of monolithic reinforced concrete structures intended for enclosures of container transformer and switching stations. A classification of the container stations due to enclosures sizes was given. Certain problems of execution of large size precast spatial elements and investigations concerning arc fault inside the station were discussed.
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 6, 6; 25-28
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie reguł asocjacyjnych do analizy pracy wybranego urządzenia w oddziale wydobywczym
Association Rules in Analysis of Selected Machine Working in a Mining Division
Autorzy:
Trzcionkowska, A.
Brzychczy, E.
Powiązania:
https://bibliotekanauki.pl/articles/319302.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
analiza danych
górnictwo
reguły asocjacyjne
język R
stacja transformatorowa
data analysis
mining
association rules
R language
transformer station
Opis:
W artykule przedstawiono możliwości wykorzystania zaawansowanych technik eksploracji danych do analizy pracy aparatury zabezpieczeniowej stacji transformatorowej, używanej w oddziałach wydobywczych w kopalniach podziemnych. Celem analizy było znalezienie czynników, które sprzyjają występowaniu zadziałania zabezpieczeń oraz określenie, które z nich występują razem w przypadku zadziałania zabezpieczenia. W badaniach wykorzystano reguły asocjacyjne. Obliczenia zostały przeprowadzone z wykorzystaniem środowiska R oraz dodatku Rattle (Graphical User Interface for Data Mining in R). W wyniku przeprowadzonych analiz uzyskano reguły wskazujące pojawiające się zależności warunkujące pracę aparatury zabezpieczeniowej wybranej stacji transformatorowej.
The article presents the application of advanced data mining techniques to analyse the operation of protection device of transformer station used in underground mines. The aim was to find the factors that favour the occurrence of protection activation. In the research association rules were used. Calculations were performed using the R environment and the addition Rattle (Graphical User Interface for Data Mining in R). As a result various rules were obtained, describing dependencies in work of protection devices for selected transformer station.
Źródło:
Inżynieria Mineralna; 2016, R. 17, nr 2, 2; 113-124
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza awaryjności oraz rangi stacji transformatorowych w sieci rozdzielczej SN
The analysis of failures and importance of transformer stations in MV distribution network
Autorzy:
Stasiak, N.
Subocz, J.
Powiązania:
https://bibliotekanauki.pl/articles/156787.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stacja transformatorowa SN/nn
awaryjność
ranga w systemie
transformer power station
reliability
importance in the distribution system
Opis:
W pracy omówiono najważniejsze strategie obsługi stacji rozdzielczych SN/nn. Przedstawiono ogólne założenia metody oceny rangi stacji w systemie elektroenergetycznym. Wykonano analizę awaryjności i rangi w systemie 1351 stacji SN/nn. Stwierdzono, że awaryjność głównych elementów wyposażenia stacji nie przekracza 1,5%. Ponad 90% stacji zaliczono do rangi „mało ważna”, a tylko nieco ponad 1% sklasyfikowano jako „strategiczne”.
The paper describes the most important strategies of MV/LV distribution station operation. There are given general ideas of the method for assessment of the importance of the station in a power system. The analysis of failures and importance was performed for 1351 stations. It was found that the failure ratio of main station elements was below 1.5%. The highest value of the failure ratio had MV switches, followed by transformers (approx. 0.7 %). The process of importance assessment was based on the following parameters: the number and power of transformers in a station, the load ratio, a type of the customer of the station, power supply configuration and a type of the station. On this basis over 90% stations were categorized as having “low importance”, while only 1% was found to be “strategic”. The above data suggests changes in the station operation procedures. The currently used TBM strategy should be replaced by the CM strategy. It would lead to lowering the operation costs without significant decrease in the energy supply quality.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 168-171
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prefabrykaty dla energetyki produkowane przez Strunobet-Migacz Sp. z o.o.
Precast concrete products for power engineering produced by Strunobet-Migacz Ltd.
Autorzy:
Migacz, H.
Koza, K.
Wójcik, S.
Powiązania:
https://bibliotekanauki.pl/articles/163159.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
Strunobet-Migacz Sp. z o.o.
profil produkcji
żerdź elektroenergetyczna
stacja transformatorowa
słup oświetleniowy
słup trakcyjny
Strunobet-Migacz Ltd.
production assortment
power line pole
transformer station
energy pile
lighting pole
traction pole
Opis:
W artykule przedstawiono rys historyczny powstania firmy Strunobet-Migacz Sp. z o.o. oraz scharakteryzowano podstawowy asortyment produkcyjny zakładu, jakim są żerdzie elektroenergetyczne z betonu, kontenerowe i nastupowe stacje transformatorowe, stanowiska słupowe oraz słupy oświetleniowe i trakcyjne.
The article presents the historical outline of Strunobet-Migacz Ltd. Basic production assortment of the plant which makes energy concrete poles, container and pole transformers, columns positions, lighting and traction columns was characterized.
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 6, 6; 22-24
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative study of DC/DC electric vehicle charging system with conventional transformer and planar transformer
Autorzy:
Rudawski, Maciej
Fatyga, Karol
Kwaśny, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/24202738.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
conventional transformer
dual active bridge
electric vehicle charging station
planar transformer
Opis:
This paper presents an analysis of electric vehicle charging station operation based on a dual active bridge topology. Two cases are considered: one with the use of a medium frequency planar transformer, the other with a conventional Litz winding transformer. An analysiswas performed using both solutions in order to compare the performance characteristics of the system for both cases and to present the differences between each transformer solution. The analysis was based on tests carried out on the full-scale model of an electric vehicle charging station, which is the result of the project "Electric vehicle charging system integrated with lighting infrastructure" realized by the Department of Drives and Electrical Machines, Lublin University of Technology. The results presented in the paper show that the conventional transformer used in the research achieved better results than the planar transformer. Based on the results obtained, the validity of using both solutions in electric vehicle charging stations was considered.
Źródło:
Archives of Electrical Engineering; 2023, 72, 2; 339--355
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koordynacja układów regulacji generatorów i transformatorów elektrociepłowni przemysłowej
Autorzy:
Szczerba, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397382.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
układ regulacji
generator
transformator
elektrociepłownia przemysłowa
control system
transformer
thermal power station
Opis:
Generatory elektrociepłowni przemysłowych (zwykle w liczbie kilku) pracują równolegle, przyłączone do szyn zbiorczych 6 kV. Szyny zbiorcze 6 kV są połączone ze stacją 110 kV za pomocą co najmniej dwóch (zwykle kilku) transformatorów 110/6 kV. Układy regulacji generatorów są często nietrafnie nastawiane, a algorytmy działania regulatorów transformatorów 110/6 kV są nieprawidłowe, uniemożliwiając współpracę układów regulacji elektrociepłowni. W artykule podano propozycję koordynacji algorytmów działania układów regulacji.
Źródło:
Acta Energetica; 2011, 1; 51-57
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena uciążliwości akustycznej stacji elektroenergetycznych najwyższych napięć
Assessment of acoustic nuisance of highest voltage power station
Autorzy:
Jaworski, M.
Szuba, M.
Powiązania:
https://bibliotekanauki.pl/articles/268707.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
stacja elektroenergetyczna
hałas
transformator
poziom mocy akustycznej
power station
noise
transformer
acoustic power level
Opis:
W referacie przedstawiono główne źródła hałasu występujące na terenie stacji elektroenergetycznych. Zaprezentowano wyniki pomiarów poziomu mocy akustycznej jednostek transformatorowych pracujących na wybranych stacjach elektroenergetycznych, w tym zależności poziomu mocy akustycznej od ilości pracujących układów wentylatorowych. Omówiono trudności w poprawnym wykonywaniu pomiarów ciśnienia akustycznego w otoczeniu transformatorów oraz problemy w dotrzymaniu dopuszczalnych poziomów dźwięku na terenach chronionych akustycznie w przypadku rozbudowy stacji elektroenergetycznych. W referacie poruszono także problem szacowania hałasu skumulowanego.
This paper presents the main sources of noise generated by high voltage power stations and the results of measurements of the sound power level of transformer units at selected power stations. The impact on the sound power level on the number of working fan systems is also presented. Difficulties in sound pressure measurements in transformer environment and difficulties in meeting acceptable sound levels in acoustically protected areas in the case of extension of power substations are discussed. The paper also demonstrated of some problems with estimating cumulative noise. The results of measurements in the environment of an autotransformer operating at the high voltage power stations showed that the operating conditions of individual sections of the autotransformer fan have no significant effect on the calculated acoustic power levels of the autotransformer. The main source of noise in the autotransformer is not the cooling fans but the sound produced in the core of the transformers and the sound accompanying the electromagnetic forces (magnetostriction).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 56; 33-37
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania oddziaływania akustycznego stacji elektroenergetycznej na środowisko
Research acoustic impact on the environment of the electric power station
Autorzy:
Augustyn, A.
Słaboń, E.
Ślusarek, A.
Powiązania:
https://bibliotekanauki.pl/articles/199185.pdf
Data publikacji:
2015
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
oddziaływanie akustyczne
autotransformator
stacja elektroenergetyczna
ochrona środowiska
acoustic impact
auto-transformer
electric power station
environmental protection
Opis:
W publikacji przedstawiono badania oddziaływania akustycznego stacji elektroenergetycznej na środowisko terenów chronionych oraz koncepcję ograniczania ponadnormatywnej emisji dźwięku. Przedstawiono metodykę rozwiązania problemu emisji dźwięku autotransformatorów do środowiska, obejmującą: pomiary emisji dźwięku, opracowanie numerycznych modeli terenu oraz pokrycia terenu w rejonie autotransformatorów. Określono wpływ głównych źródeł dźwięku na rozkład pola akustycznego na terenach chronionych akustycznie oraz przedstawiono koncepcję zabezpieczeń przeciwhałasowych.
Research of acoustic study of electric power station on the environment for the protected area and the concept of reducing excessive sound emission, are presented. The methodology of solving the problem of auto-transformers sound emission to the environment, including: acoustic measurement, develop digital terrain model and land cover in the area of auto-transformers. The influence of the main sound sources on the distribution of the sound field acoustically protected areas and introduced the concept of protection.
Źródło:
Maszyny Górnicze; 2015, 33, 2; 25-29
0209-3693
2450-9442
Pojawia się w:
Maszyny Górnicze
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies