Wyszukujesz frazę "transformer" wg kryterium: Temat


Tytuł:
Basic equations for analysis of a three-phase three-winding transformer subjected to asymmetric load
Autorzy:
Kasprzyk, L.
Stein, Z.
Zielińska, M.
Powiązania:
https://bibliotekanauki.pl/articles/97483.pdf
Data publikacji:
2011
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
winding of the transformer
transformer
Opis:
The paper presents a set of equations enabling analysis of operation of three-phase three-winding transformers under asymmetric load. For a selected asymmetric state of such a transformer the computation leading to analysis of characteristic output parameters of the transformer is carried out with the help of the Mathcad software.
Źródło:
Computer Applications in Electrical Engineering; 2011, 9; 161-169
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Industrial transformer stations
Autorzy:
Kołaciński, R.
Paluszczak, M.
Twardosz, G.
Powiązania:
https://bibliotekanauki.pl/articles/97289.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformer stations
electric power
transformer
Opis:
The paper presents a modern design of semi-underground transformer station of BST- PP 20/630 type. The station is designed to be supplied from medium-voltage distribution network. Maximum transformer power S = 630 kVA. The transformer is installed underground. The part situated above the ground may be used as an advertising surface.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 189-193
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The determination of measuring transformer windings impedance by using an three stage measuring method
Autorzy:
Piaskowy, A.
Skórkowski, A.
Tokarski, J.
Musioł, K.
Powiązania:
https://bibliotekanauki.pl/articles/114280.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
windings impedance
measuring transformer
transformer ratio error
Opis:
A developed three stage method for determination the windings impedance of measuring transformer are shown in this paper. During the measurement process, there is no need to use the standard voltage divider instead, a voltage divider having the constant, unknown error is used. This ratio error is eliminated during measuring procedure. In this paper, the obtained measurement results of the winding impedance and uncertainty budged are presented.
Źródło:
Measurement Automation Monitoring; 2017, 63, 8; 268-270
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Technical Condition of the Active Part of the High Power Transformer Based on Measurements and Analysis of Vibroacoustic Signals
Autorzy:
Borucki, S.
Cichoń, A.
Majchrzak, H.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/176397.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vibration
vibroacoustic method
core
power transformer
transformer diagnostics
Opis:
This article presents the results of research connected with the development and industrial use of vibroacoustic methods for the evaluation of the technical condition of the active part of transformers. The article presents the results of the analysis of vibrations generated by the high power transformer in which a defect was found on the basis of tests of oil carried out using the chromatography tests. In order to confirm the damage of the active part of this transformer, vibroacoustic measurements were performed in three states of its operation. The measurement using the classical vibroacoustic method included the registration of vibrations at the idle speed and during the load operation of the transformer. The original diagnostic method, so-called the modified vibroacoustic method, was also used during the measurement. The analysis of signals recorded using the classical vibroacoustic method was carried out in the frequency domain by indicating the amplitude of even harmonic vibrations. However, the analysis of signals measured during the commissioning of the transformer was conducted in the time-frequency domain using the short-time Fourier transform (STFT), continuous wavelet transform (CWT), and discrete wavelet transform (DWT). On the basis of the analysis of the results obtained it was stated that the increased level of vibrations of this transformer is a consequence of the loss of rigidity of the mechanical structure of its core.
Źródło:
Archives of Acoustics; 2017, 42, 2; 313-320
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Power Transformer as a Source of Noise
Autorzy:
Zawieska, W. M.
Powiązania:
https://bibliotekanauki.pl/articles/90466.pdf
Data publikacji:
2007
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
power transformer
noise reduction
active methods
transformer modeling
rectangular plate vibrations
transformer noise
vibroacoustic analysis
Opis:
This article presents selected results of analyses and simulations carried out as part of research performed at the Central Institute of Labor Protection – the National Research Institute (CIOP-PIB) in connection with the development of a system for active reduction of noise emitted by high power electricity transformers. This analysis covers the transformer as a source of noise as well as a mathematical description of the phenomenon of radiation of vibroacoustic energy through a transformer enclosure modeled as a vibrating rectangular plate. Also described is an acoustic model of the transformer in the form of an array of loudspeakers.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2007, 13, 4; 381-389
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ATP/EMTP study of ferroresonance involving HV inductive VT and circuit breaker capacitance
Autorzy:
Stosur, M.
Piasecki, W.
Florkowski, M.
Fulczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/262758.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
inductive voltage transformer
transformer core
ferroresonance
ATP-EMTP
simulation
Opis:
Ferroresonance is a phenomenon usually initiated by transients in power networks resulting from e.g. switching operations or ground faults. Non linear behavior of the core of an inductive voltage transformer results in magnetic saturation. long-lasting ferroresonant state is dangerous to the equipment due to prolonged overvoltage and large overcurrents in HV windings.in the present article numerical simulations of the ferroresonance phenomenon in a HV inductive Vare presented. the ferroresonant oscillations analyzed result from interaction between the voltage transformer and a grading capacitance of a circuit breaker.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2008, 14, 2; 49-52
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer modeling in the diagnostics of transformers’ windings deformations
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/97341.pdf
Data publikacji:
2010
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformer
computer model
winding of the transformer
frequency response
Opis:
The diagnostics of power transformers is very important in order to plan repairs and replacements of aged population of transformers operated in Poland and Europe. One of these methods is Frequency Response Analysis - FRA. It can detect any mechanical changes in active part of transformer, which may even lead to serious faults of units in service. As the method is based on comparison of measured curves, which are not always available from previous measurements the computer modeling was applied to create models of windings’ response. The paper presents examples of models created for simple windings and also for real transformer with some deformations of windings simulated.
Źródło:
Computer Applications in Electrical Engineering; 2010, 8; 132-140
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transformer performance enhancement by optimized charging strategy for electric vehicles
Autorzy:
Venkataswamy, R.
Uma Rao, K.
Meena, P.
Powiązania:
https://bibliotekanauki.pl/articles/2042802.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
charging stations
electric vehicle
e-mobility
optimization
transformer efficiency
transformer regulation
Opis:
Transformer efficiency and regulation, are to be maintained at maximum and minimum respectively by optimal loading, control, and compensation. Charging of electric vehicles at random charging stations will result in uncertain loading on the distribution transformer. The efficiency reduces and regulation increases as a consequence of this loading. In this work, a novel optimization strategy is proposed to map electric vehicles to a charging station, that is optimal with respect to the physical distance, traveling time, charging cost, the effect on transformer efficiency and regulation. Consumer and utility factors are considered for mapping electric vehicles to charging stations. An Internet of Things platform is used to fetch the dynamic location of electric vehicles. The dynamic locations are fed to a binary optimization problem to find an optimal routing table that maps electric vehicles to a charging station. A comparative study is carried out, with and without optimization, to validate the proposed methodology.
Źródło:
Archives of Electrical Engineering; 2022, 71, 1; 37-56
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative study of DC/DC electric vehicle charging system with conventional transformer and planar transformer
Autorzy:
Rudawski, Maciej
Fatyga, Karol
Kwaśny, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/24202738.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
conventional transformer
dual active bridge
electric vehicle charging station
planar transformer
Opis:
This paper presents an analysis of electric vehicle charging station operation based on a dual active bridge topology. Two cases are considered: one with the use of a medium frequency planar transformer, the other with a conventional Litz winding transformer. An analysiswas performed using both solutions in order to compare the performance characteristics of the system for both cases and to present the differences between each transformer solution. The analysis was based on tests carried out on the full-scale model of an electric vehicle charging station, which is the result of the project "Electric vehicle charging system integrated with lighting infrastructure" realized by the Department of Drives and Electrical Machines, Lublin University of Technology. The results presented in the paper show that the conventional transformer used in the research achieved better results than the planar transformer. Based on the results obtained, the validity of using both solutions in electric vehicle charging stations was considered.
Źródło:
Archives of Electrical Engineering; 2023, 72, 2; 339--355
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stacje transformatorowe typu MAR, MAR-G z wyłącznikami próżniowymi na odpływach
MAR and MAR-G transformer stations with vacuum circuit breaker at outlets
Autorzy:
Kozłowski, A.
Wosik, J.
Brol, J.
Mistarz, M.
Powiązania:
https://bibliotekanauki.pl/articles/187639.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
stacje transformatorowe
transformer stations
Opis:
W referacie przedstawiono rozwiązanie stacji transformatorowej z nowo opracowaną wieloodpływową komorą dolnego napięcia z wyłącznikami próżniowymi na odpływach. Zaprezentowano powstały w ten sposób typoszereg stacji oraz podstawowe parametry techniczne. Omówiono możliwości konfiguracyjne w zakresie wielowariantowości wersji wykonawczych uzależnionych od wymagań użytkownika. Zwrócono uwagę na zasilanie odbiorów energoelektronicznych z możliwością stosowania wieloparametrowrych zabezpieczeń upływowych, a także na bardzo istotną kwestię autokontroli zewnętrznego obwodu pomiarowego zabezpieczeń centralnych.
MAR and MAR-G transformer stations with vacuum circuit breaker at outlets. The article describes a transformer station with a multi-outlet low voltage chamber with vacuum circuit breakers at outlets. This way a series of types of the station was developed (examples in attached figures), which was described in the article along with basic technical parameters. The authors discussed configuration possibilities as far as different variants of the solution are concerned, depending on the client's requirements. The focus was put on power supply of power electronic receptions with possible use of multi-parameter leakage protection units and on an important issue of auto-control of an external measuring circuit of central protection units.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2012, R. 50, nr 12, 12; 7-14
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zjawisk ferrorezonansowych na pracę bezpiecznika przekładnika średniego napięcia
The effect of ferroresonance phenomena on operation of the fuse to medium voltage measuring transformer
Autorzy:
Tłustochowicz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/267582.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ferrorezonans
bezpiecznik przekładnika
przekładnik napięciowy
ferroresonance
voltage transformer’s fuse
voltage transformer
Opis:
Bezpieczniki przekładnikowe stanowią zabezpieczenia obwodów uzwojeń pierwotnych przekładników napięciowych od skutków zwarć. W praktyce eksploatacji sieci elektroenergetycznych średnich napięć z przekładnikami obserwowane są przypadki zadziałań bezpieczników przekładnikowych w następstwie zjawisk ferrorezonansowych. Przyczyną zjawisk ferrorezonansowych w przekładniku jest najczęściej nagły wzrost napięcia na jego uzwojeniu pierwotnym, wywołany przez przepięcia łączeniowe lub atmosferyczne. Wobec zmniejszenia się w tych warunkach indukcyjności magnesowania przekładnika może wystąpić sytuacja, w której indukcyjność ta z pojemnością doziemną systemu elektroenergetycznego stworzą obwód rezonansowy. W większości przypadków skutkuje to niekontrolowanym wzrostem prądu w obwodzie pierwotnym przekładnika, czego konsekwencją może być zadziałanie bezpiecznika przekładnika. Wieloletnia eksploatacja przekładników w systemach elektroenergetycznych średnich napięć z izolowanym punktem neutralnym potwierdza przypadki takich zdarzeń.
Measuring transformer fuses are used to the protection of primary winding of voltage measuring transformers against the ef-fects of short-circuits. In practice, under operating conditions of medium voltage networks with voltage measuring transfor-mers, there have been observed some cases of fuse maloperation resulting from the ferroresonance phenomena. The reason of ferroresonance phenomena in voltage measuring transformer is mostly a step-wise change of voltage across its primary winding, due to switching overvoltages or lightning surges. Under these circuimstances, the magnetizing inductance of vol-tage measuring transformer is significantly diminished, so a resonance circuit may be formed with the capacitance of power system versus earth. In most cases it results in an uncontrolled rise of the current in primary winding of voltage measuring transformer and consequently-maloperation of the fuse protection. Long-lasting observations on operation of voltage measur-ing transformers in medium voltage power system with isolated neutral point have confirmed the events of cases being considered in this paper.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 28; 131-134
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca bezpiecznika przekładnika średniego napięcia w warunkach ferrorezonansu
Operation of fuses to medium voltage measuring transformers under ferroresonance condictions
Autorzy:
Tłustochowicz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/268080.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ferrorezonans
bezpiecznik przekładnikowy
przekładnik
przepięcie
ferroresonance
voltage transformer's fuse
voltage transformer
overvoltage
Opis:
Obserwowane są przypadki działania bezpieczników średnich napięć chroniących przekładniki napięciowe od skutków przetęSeń podczas ferrorezonansu napięć. W artykule przed-stawiono wyniki badań symulacyjnych wpływu zjawisk ferrorezonansowych na pracę bezpiecznika SN. Ferrorezonans moSe wystąpić w wyniku nagłej zmiany napicia pracy przekładnika, której przyczynami mogą być przepięcia łączeniowe lub atmosferyczne. Wyniki badań symulacyjnych nie wykluczają moSliwości działania bezpiecznika przekładnika SN w następstwie zjawisk ferrorezonansowych, powodowanych przepięciem. Przypadki takich zdarzeń są rejestrowane w praktyce eksploatacji sieci średnich napięć i potwierdzone badaniami laboratoryjnymi.
There are observed some cases of maloperation of fuses, which are used to the protection of medium voltage measuring transformers against results of overcurrents at voltage ferroresonance. The paper presents results of simulation study of the effect of ferroresonance phenomena upon medium voltage fuse operation. The ferroresonance may occur at a sudden change of measuring transformer operation voltage, which may result, e.g. from switching overvoltages or lightning surges. Simulation study has not excluded maloperation of a fuse to medium voltage measuring transformer resulting from ferroresonance phenomena. Such events have been registered in practice, in operation of medium voltage networks and confirmed by laboratory experiments.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2009, 26; 117-120
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of the inductive current transformer derating for operation with distorted currents
Autorzy:
Kaczmarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/201060.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer
distorted current
derating conditions
composite errors
transformer correction factor
accuracy class
Opis:
The aim of the paper is to present a new method for estimation of the CT (Current Transformer) rated primary current and / or load of the secondary winding derating levels for transformation of distorted current in relation to the rated values fixed for transformation of sinusoidal current. This ensures the values of the CT composite errors/transformer correction factors as resulting from its IEC 60044-1/IEEE C57.13 accuracy class in condition of distorted currents transformation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 2; 363-366
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Field-circuit modelling of an advanced welding transformer with two parallel rectifiers
Autorzy:
Sakhno, L.
Sakhno, O.
Dubitsky, S.
Powiązania:
https://bibliotekanauki.pl/articles/141600.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arc welding
double-bridge rectifier
leakage inductance
three-winding transformer
transformer equivalent circuit
Opis:
The new topology of three-winding welding transformer is proposed. Each secondary winding is connected in parallel through the separate bridge rectifier to the welding arc. The main feature of the proposed device is parallel working of two secondary windings with different rated voltage. The advantage is nonlinear transformation ratio of current that provides unprecedented power efficiency. The self- and mutual leakage inductances, which are important in power conversion, are calculated by 2D FEA model. The operational current of the device is modelled numerically via P-Spice simulator. The proposed topology is up to 30% more power effective than conventional welding transformer provided that the leakage inductances of primary and secondary windings are correctly fitted. This transformer is used for manual arc welding.
Źródło:
Archives of Electrical Engineering; 2015, 64, 2; 249-257
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structure of the automatic protection of a 2-tank symmetric phase shifting transformer
Struktura automatyki zabezpieczeniowej 2-kadziowego symetrycznego przesuwnika fazowego
Autorzy:
Bednarczyk, T.
Halinka, A.
Rzepka, P. A.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/396889.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
phase shifting transformer
automatic protection
transformer
disturbance
przesuwnik fazowy
automatyka zabezpieczeniowa
transformator
zakłócenia
Opis:
Phase shifting transformers (PST) are new elements in the Polish power system. Their main task is to enable the transmission system operator to control the active power flows at the cross-border connection between the Polish and the German power systems. The paper presents the design characteristics of a 2-tank, 3-phase, symmetric phase shifting transformer (including key structural aspects) and the idea of its operation. A description of the structure of the automatic protection applied to this phase shifting transformer is included, with consideration of the measuring transducer locations and the protection criteria employed in the protection from the effects of high current short circuits.
Przesuwniki fazowe są nowym elementem polskiego systemu elektroenergetycznego. Ich podstawowym zadaniem jest umożliwienie operatorowi systemu przesyłowego sterowania przepływami mocy czynnej na połączeniu transgranicznym polskiego i niemieckiego systemu elektroenergetycznego. W artykule przedstawiono charakterystykę budowy 2-kadziowego, 3-fazowego, symetrycznego przesuwnika fazowego (z uwzględnieniem kluczowych aspektów konstrukcyjnych) oraz ideę jego działania. Zamieszczono opis struktury elektroenergetycznej automatyki zabezpieczeniowej stosowanej dla takiego przesuwnika fazowego, uwzględniając umiejscowienie przetworników pomiarowych oraz kryteria zabezpieczeniowe wykorzystywane w zabezpieczeniach służących do jego ochrony przed skutkami zwarć wielkoprądowych.
Źródło:
Acta Energetica; 2017, 3; 4-13
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic monitoring of the power transformers
Autorzy:
Lisowska-Lis, A.
Powiązania:
https://bibliotekanauki.pl/articles/114168.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformer
thermography
diagnostics
monitoring
cooling
Opis:
Results of thermographic monitoring of exemplary power transformers are presented in the paper. Series of thermograms were taken. The areas on the transformer surfaces were analysed for higher temperature in aspects of: the electrical insulation condition of the transformer, the area on the surface, the season of the measurement. The thermograms indicated inefficient cooling for the transformers with deteriorated electrical insulation, especially during the summer season.
Źródło:
Measurement Automation Monitoring; 2017, 63, 4; 154-157
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coupling the Autocad and Delphi environments for generating 3D finite element mesh in the electromagnetic devices design
Autorzy:
Kowalski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1373303.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
AutoCAD
transformator
dyskretyzacja
transformer
discretization
Opis:
A computer - aided design system for electromagnetic device is presented. The system has been adopted for the design of the middle-power three-phase transformers. The elaborated system consists of (1) computer application aiding the design and discretization process and (2) a module for presentation of the results of calculation and design process. The results of calculations may be presented in a textual or graphic form. The AutoCAD program is used for the graphic presentation.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 87; 205-208
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of the pulse transformer using circuit-field model
Autorzy:
Łyskawiński, W.
Knypiński, Ł.
Nowak, L.
Jędryczka, C.
Powiązania:
https://bibliotekanauki.pl/articles/1395761.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
pulse transformer
optimization
genetic algorithm
Opis:
The paper presents the new strategy of the optimization of pulse transformer (PT). In order to reduce calculation time the optimization problem has been decomposed into two stages. In the first stage, to determine functional parameters of PT the circuit model is used. The goal of circuit calculations is to limit the space of design variables that meets formulated requirements. The genetic algorithm has been applied for this task. In order to include constraints, the penalty function has been engaged. The transformer dimensions obtained in the first stage of calculations are used as initial values in the second stage of design process. In the second stage the field model of PT is employed. Obtained results prove that presented approach allows for fast optimization of the PT design.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 159-167
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of modern semiconductor devices from silicon carbide for the construction of the synchronous rectifiers
Autorzy:
Krupa, A.
Powiązania:
https://bibliotekanauki.pl/articles/115528.pdf
Data publikacji:
2011
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
SiC devices
synchronous rectifier
transformer
Opis:
In low-voltage isolated DC-DC converters, power losses due to the conduction of rectifying devices are significant. Using synchronous rectifiers instead of the conventional fast recovery diodes is an effective solution to this problem in most topologies. This paper provides results of computer simulation in PSpice of implementation SiC (silicon-carbide) diode in synchronous rectifier topology and shows advantages of this solution.
Źródło:
Challenges of Modern Technology; 2011, 2, 2; 13-15
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Design and Operation of IEC 61850 – Based Transformer Measuring Device
Konstrukcja i działanie urządzenia pomiarowego transformatorów wykorzystującego IEC 61850
Autorzy:
Kopański, P.
Rasolomampionona, D. D.
Powiązania:
https://bibliotekanauki.pl/articles/397113.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
monitoring
transformer
IEC 61850
transformator
Opis:
The submitted paper presents the results of research on the development of a monitoring system for HV power transformers using the IEC 61850 communication standard. The characteristic feature of this system is its implementation on Linux-based programmable PLC. Data registration functionality, aggregation, archiving and data visualization are merged on one controller. Data registration is performed through built-in digital and analogue input cards, Ethernet and serial ports used for communication with external devices. Data aggregation and archiving is based on the MySQL database system, through data visualization and presentation thanks to an in-built HTML server with an implemented HTML web page that shows the most important parameters in real time. In addition, the implemented IEC 61850 stack enables a direct communication with the SCADA system. The stack has been implemented within the controller in such a way that the need for additional equipment, such as standard machine translation, is reduced. Both the device and all the algorithms developed in the Institute of Electrical Engineering allow collecting and recording the signals in real time, and moreover make a preliminary diagnosis of the transformer.
Artykuł zawiera wyniki badań nad opracowaniem systemu monitoringu transformatorów najwyższych mocy wykorzystującego standard IEC 61850. Cechą charakterystyczną opisywanego systemu jest jego implementacja na programowalnym sterowniku PLC, bazującym na systemie Linux. W jednym sterowniku została połączona funkcjonalność rejestracji, agregacji, archiwizacji i wizualizacji danych.
Źródło:
Acta Energetica; 2014, 1; 72-82
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence Of Transformer Tap Changer Operation On Voltage Stability
Autorzy:
Brusiłowicz, B.
Szafran, J.
Powiązania:
https://bibliotekanauki.pl/articles/410519.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
voltage stability
transformer tap changer
Opis:
The paper concerns influence of transformer tap changer regulation on secondary voltage level and voltage stability margin of receiving node. At the beginning there are presented general information about voltage stability and tap changer. Voltage value of secondary terminals of transformer can be regulated using tap changer. This regulation also affects the calculation of Thevenin equivalent parameters seen from the secondary terminals. Changes of equivalent parameters cause a change of voltage stability conditions. Simulation studies of this influence for various types of load have been done. Selected simulation results are presented in the paper. At the end there are placed conclusions from the performed studies.
Źródło:
Present Problems of Power System Control; 2013, 4; 25-36
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie nieliniowości obwodu magnetycznego na przykładzie transformatora 1 fazowego. Aspekty dydaktyczne
Modelling the magnetic circuit nonlinearity of the one phase transformer. Teaching aspects
Autorzy:
Ronkowski, M.
Michna, M.
Kutt, F.
Kostro, G.
Powiązania:
https://bibliotekanauki.pl/articles/267805.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
transformator
nieliniowość obwodu magnetycznego
nauczanie
educational courses
electrical engineering education
transformer
transformer core nonlinearity
Opis:
W artykule opisano proces dydaktyczny związany z analizą stanów przejściowych na przykładzie załączania nieobciążonego transformatora 1-fazowego. Eksploatacja transformatorów z rdzeniem ferromagnetycznym wiąże się z koniecznością przeciwdziałania skutkom dużych prądów łączeniowych, w tym odpowiedniego doboru zabezpieczeń. Zrozumienie przyczyn powstawania prądu łączeniowego jest kluczowym zagadnieniem przy doborze aparatury w obwodach zasilania transformatora. Autorzy opisują metodę modelowania nieliniowości obwodu magnetycznego transformatora prezentowaną podczas zajęć dydaktycznych z przedmiotu Systemy Elektromechaniczne dla studentów II stopnia studiów na kierunku Elektrotechnika.
The paper describes the teaching process of the transients analysis based on the switch on the unloaded one phase transformer. The use of iron-core transformer is associated with need to counter the effects of high inrush currents during this transient state, including proper selection of protection system and switch gear. Understanding the causes of switching current is a key issue in the selection of equipment in the supply circuits of power transformer. The authors describe a method for modeling non-linearity of the magnetic circuit of the transformer presented during classes on the subject of electromechanical systems for students of second cycle of studies in Electrical Engineering.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 151-154
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of the state of oil-paper insulation in group 2 transformers
Diagnostyka stanu izolacji papierowo-olejowej transformatorów drugiej grupy
Autorzy:
Gos, A.
Gos, M.
Mroczkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/257212.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
transformer oil
oil-paper insulation
transformer diagnosis
olej elektroizolacyjny
izolacja papierowo-olejowa
diagnostyka
transformator
Opis:
The article describes causes of the need to monitor the technical condition of transformers by analysing the physicochemical properties of the oil-paper insulation. The article also describes the importance of individual indicators determining the quality of transformer oil and discusses the results of the operating oil in a 49-year-old transformer before and after exchange.
W artykule opisano przyczyny konieczności monitorowania stanu technicznego transformatorów poprzez analizę właściwości fizykochemicznych izolacji papierowo-olejowej. Opisano znaczenie poszczególnych wskaźników decydujących o jakości oleju transformatorowego oraz omówiono wyniki oleju pracującego w 49-letnim transformatorze przed i po jego wirowaniu.
Źródło:
Problemy Eksploatacji; 2014, 3; 73-81
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomagane komputerem obliczanie jednordzeniowego układu kaskadowego indukcyjnego przekładnika napięciowego wysokiego napięcia
Computer aided computation of one-core cascade circuit of HV voltage transformer
Autorzy:
Jałmużny, W.
Adamczewska, D.
Borkowska-Banaś, I.
Powiązania:
https://bibliotekanauki.pl/articles/152839.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektromagnetyczny układ kaskadowy jednordzeniowy
przekładnik napięciowy wysokiego napięcia
wspomaganie komputerowe projektowania
single-core transformer
cascade scheme transformer
HV voltage transformer
computer-aided design
Opis:
W artykule przedstawiono model matematyczny dwustopniowej, jednordzeniowej struktury elektromagnetycznej przekładnika napięciowego indukcyjnego. Podano jego opis analityczny dla chwilowych wartości napięć i prądów. Zbudowano schemat zastępczy umożliwiający wykorzystanie metody symbolicznej do opracowania komputerowego modelu symulacyjnego. Przedstawiono wybrane ekrany autorskiego programu komputerowego umożliwiającego realizowanie kolejnych kroków procesu projektowania.
The issue of electromagnetic cascade structures involves, among others, the current transformers [1] and inductive voltage trans-formers [2]. The following paper is a result of continuation of effort taken by the authors to prepare mathematical model of multistage inductive voltage transformers [3, 4]. Other publications on the topic include [5] and [6]. The mathematical model of HV single-core double primary winding inductive voltage transformer is presented in the paper. The scheme of the transformer configuration in Fig. 1 can be characterized by relationships between instantaneous values of voltages, currents and magnetic flux density - presented in formulas (1). These expressions can be utilized in computer simulations scoped to trace graphs of waveforms for instantaneous values of primary and secondary voltages [7, 8]. Calculation results were verified against measurement results for physical models. The equivalent circuit presented in Fig. 2 and described with formulas (2) has been de-signed, allowing to develop a computer simulation model by means of symbolic method. The sample screens presented in the article originate from computer software enabling execution of successive steps of designing process. The developed calculation method for cascade structure of voltage transformer can be utilized in designing process of core and windings for "electrically inverted" structure, like the ones used in HV voltage transformers, where primary side acts as the low voltage winding.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 9, 9; 1097-1099
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza działania zabezpieczenia podimpedancyjnego dwukadziowego symetrycznego przesuwnika fazowego
Analysis of protection operation under impedance double tank symmetric phase shifting transformer
Autorzy:
Bednarczyk, T.
Halinka, A.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/267229.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
automatyka zabezpieczeniowa
transformator
zakłócenia
Phase Shifting Transformer
power system protection
power transformer
disturbances
Opis:
Zabezpieczenie wykorzystujące kryterium podimpedancyjne stanowi jedno z podstawowych zabezpieczeń jednostek transformatorowych najwyższych napięć (w tym przesuwników fazowych). Zabezpieczenie podimpedancyjne identyfikuje stan pracy chronionego przesuwnika fazowego, sprawdzając położenie końca wektora impedancji wyznaczanej w zabezpieczeniu względem stref pomiarowych zabezpieczenia. Podczas zwarć w obrębie fragmentu sieci objętego ochroną przez zabezpieczenie, koniec wektora impedancji powinien „wchodzić” do stref pomiarowych zabezpieczenia. Wówczas następuje zadziałanie zabezpieczenia i ewentualne wyłączenie przesuwnika fazowego. W artykule zamieszczono wyniki przeprowadzonych badań symulacyjnych warunków działania zabezpieczenia podimpedancyjnego dla dwukadziowego symetrycznego przesuwnika fazowego. W symulacjach uwzględniono szeroki zakres zmian impedancji przesuwnika fazowego, zwarcia wewnętrzne oraz zewnętrzne. Wyniki badań symulacyjnych pozwalają na weryfikację poprawności działania zabezpieczenia podimpedancyjnego przesuwnika fazowego.
Relay protection using criterion under impedance is one of the basic security units high voltage transformer (including phase shifters - PST, ang. Phase Shifting Transformer). Protection under impedance identifies the operating status of the protected PST, checking the position of the end vector impedance to be fixed in terms of securing zones measuring security. While short-circuits within the network portion of the end vector impedance should "enter" zones measuring security. Then followed by a safety device and possible exclusion PST. The article contains the results of the simulation tests of operating conditions for security under impedance doubletransformer tank dwukadziowego symmetric phase shifter. The simulations take into account a wide range of impedance changes PST, short circuit, internal and external. The results of simulation studies allow for verification of correct operation of security under impedance PST.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 71-74
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies