Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tracer" wg kryterium: Temat


Tytuł:
Numerical Simulations and Tracer Studies as a Tool to Support Water Circulation Modeling in Breeding Reservoirs
Autorzy:
Zima, P.
Powiązania:
https://bibliotekanauki.pl/articles/241289.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
breeding reservoir hydraulics
water circulation
tracer study
mathematical modeling
kinematics models
Opis:
The article presents a proposal of a method for computer-aided design and analysis of breeding reservoirs in zoos and aquariums. The method applied involves the use of computer simulations of water circulation in breeding pools. A mathematical model of a pool was developed, and a tracer study was carried out. A simplified model of two-dimensional flow in the form of a biharmonic equation for the stream function (converted into components of the velocity vector) was adopted to describe the flow field. This equation, supplemented by appropriate boundary conditions, was solved numerically by the finite difference method. Next, a tracer migration equation was solved, which was a two-dimensional advection-dispersion equation describing the unsteady transport of a non-active, permanent solute. In order to obtain a proper solution, a tracer study (with rhodamine WT as a tracer) was conducted in situ. The results of these measurements were compared with numerical solutions obtained. The results of numerical simulations made it possible to reconstruct water circulation in the breading pool and to identify still water zones, where water circulation was impeded.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2014, 61, 3-4; 217--229
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The CFD modeling in bioreactor tracer studies
Autorzy:
Zima, P.
Powiązania:
https://bibliotekanauki.pl/articles/1933153.pdf
Data publikacji:
2007
Wydawca:
Politechnika Gdańska
Tematy:
mathematical modeling
pollutant migration
reactor hydraulics
advection-dispersion equation
tracer studies
Opis:
This paper presents the effects of dispersion on predicting longitudinal tracer concentration profiles in an activated sludge bioreactor located at the Wschód Waste-Water Treatment Plant in Gdansk. The aim of this study has been to use the one-dimensional advection-dispersion equation to simulate a non-active substance flow (based on the measured tracer concentration). The simulation results were compared with those obtained in the traditional tanks-in-series approach, commonly used in designing biological reactors. The dispersion coefficient was calculated from a statistical formula based on differences in the tracer concentration distributions at two sampling points. The study has shown that the numerical simulation using the one-dimensional tracer migration equation yields better results than the tanks-in-series model in predicting longitudinal tracer concentration profiles. This paper is an in-troduction to the study of reactive substances in activated sludge bioreactors.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2007, 11, 4; 439-447
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie stabilności barwnych znaczników fluorescencyjnych w silnie zasiarczonych wodach złożowych
Study on the stability of colored fluorescent tracers in highly sulfated reservoir waters
Autorzy:
Wojtowicz, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2143540.pdf
Data publikacji:
2021
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
znacznik
fluoresceina
eozyna Y
rodamina B
uranina
tracer
fluorescein
eosin yellowish
rhodamine B
uranine
Opis:
W artykule zostały przedstawione zagadnienia związane z oznaczaniem barwnych znaczników fluorescencyjnych, takich jak fluoresceina, eozyna żółtawa, rodamina B i uranina, w wodach złożowych metodą spektrofotometryczną. W tym celu sprawdzono wpływ pH roztworu na widma absorpcji badanych znaczników. Otrzymane wyniki wykazały, że fluoresceina, rodamina B i uranina są wrażliwe na zmianę odczynu roztworu, dlatego w dalszych badaniach wskazane jest stosowanie stabilnych roztworów znaczników oraz kontrola i ewentualna korekta pH. W ramach badań wykreślono krzywe kalibracyjne fluoresceiny, eozyny żółtawej, rodaminy B i uraniny w wodzie destylowanej, wodzie złożowej A4 i silnie zasiarczonych wodach złożowych A5 i A6 oraz przeprowadzono walidację metody analitycznej. Walidacja ta obejmowała wyznaczenie liniowości, odchylenia standardowego i względnego odchylenia standardowego badanych znaczników. Wysokie wartości współczynników regresji (0,9927–0,9998) analizowanych znaczników świadczą o dobrym dopasowaniu liniowym, natomiast niskie wartości odchylenia standardowego i względnego odchylenia standardowego – o powtarzalności i precyzji metody. Szczególną uwagę zwrócono na badania trwałości barwnych znaczników fluorescencyjnych w silnie zasiarczonych wodach złożowych. W tym celu sporządzono roztwory badanych znaczników o stężeniu 10 mg/dm3 w wodzie destylowanej, wodzie złożowej A4 i silnie zasiarczonych wodach złożowych A5 i A6. Pomiar stężenia znaczników w badanych wodach wykonywano co 2 dni przez okres 1 miesiąca. Uzyskane wyniki badań wykazały, że roztwory fluoresceiny, eozyny żółtawej, rodaminy B i uraniny są stabilne w wodzie destylowanej i wodzie złożowej A4, natomiast w wodach złożowych A5 i A6 ulegają degradacji. Najbardziej wrażliwe okazały się fluoresceina i jej pochodna uranina, które w wodzie złożowej A6 uległy całkowitej degradacji po 20 (fluoresceina) i 22 (uranina) dniach. Nieznacznie bardziej trwałe w silnie zasiarczonych wodach złożowych okazały się eozyna żółtawa i rodamina B, które w wodzie złożowej A6 uległy całkowitej degradacji po 24 dniach.
The article presents the issues related to the determination of colored fluorescent tracers such as fluorescein, eosin yellowish, rhodamine B and uranine in reservoir waters by spectrophotometric method. For this purpose, the influence of the pH of the solution on the absorption spectra of the tested tracers was checked. Test results show that fluorescein, rhodamine B and uranine are sensitive to changes in the buffer pH, therefore it is advisable to use stable tracer solutions as well as to control and possibly correct pH in further tests. As part of the study, calibration curves of fluorescein, eosin yellowish, rhodamine B and uranine in distilled water, reservoir water A4 and highly sulfated reservoir waters A5 and A6 were plotted and the analytical methods were validated. Analytical validation included determination of linearity, standard deviation and relative standard deviation of the tested tracers solutions. High values of the regression parameters (0.9927– 0.9998) of the analyzed tracers prove a good linear fit, while low values of standard deviation and relative standard deviation prove its repeatability and precision. Particular attention was paid to testing the stability of colored fluorescent tracers in highly sulfated reservoir waters. For this purpose, solutions of the tested tracers were prepared at concentrations of 10 mg/dm3 in distilled water, A4 reservoir water and highly sulfated A5 and A6 reservoir waters. Measurements of the tested tracers in the prepared solutions were performed every 2 days over the period of 1 month. The test results show that fluorescein, eosin yellowish, rhodamine B and uranine solutions are stable in the distilled water and A4 reservoir water, while they degrade in the A5 and A6 reservoir waters. Fluorescein and uranine turned out to be the most sensitive, as they degraded completely in the A6 reservoir water after 20 (fluorescein) and 22 (uranine) days. Yellowish eosin and rhodamine B turned out to be slightly more stable in highly sulfated reservoir waters, as they degraded completely in the A6 reservoir water after 24 days.
Źródło:
Nafta-Gaz; 2021, 77, 2; 82-91
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving of mixing effi ciency in a stirred reactor for lead recycling using computer simulation
Zwiększenie wydajności łączenia w reaktorze mieszalnikowym dla odzysku ołowiu przy użyciu symulacji komputerowej
Autorzy:
Vite-Martinez, P.
Ramirez-Lopez, A.
Romero-Serrano, A.
Chavez-Alcala, F.
Lopez-Ramirez, S.
Powiązania:
https://bibliotekanauki.pl/articles/317869.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
mieszanie ołowiu
ocena wydajności mieszania
stężenie pierwiastka
obliczeniowa mechanika płynów (CFD)
lead stirring
mixing efficiency evaluation
tracer concentration
computational fluid dynamics (CFD)
Opis:
Recycling is helping to reduce environmental risks and damages. Liquid lead is recovered from batteries in stirred batch reactors. Nevertheless it is necessary to establish parameters to evaluate mixing performance in order to make more efficient the industrial practices. Then this work is dedicated to simulate fluid hydro-dynamics in a lead stirred reactor by monitoring the distribution of an injected tracer to find the best injection point. Different injected points have been evaluated monitoring the tracer concentration on a group of points inside the batch to verify mixing. The tracer is assumed as ideal (with the same physical properties than lead). The reactor is a batch with two geometrical sections one cylindrical body and a semispherical on the bottom. The impeller used to promote lead stirring is a shaft with four flat blades. The tracer concentration on the monitoring points is averaged to evaluate the efficiency all around the reactor. Finally invariability of tracer concentration on the monitoring points is adopted as the criterion to evaluate mixing.
Recykling pomaga zredukować ryzyko i szkody związane ze środowiskiem. Ciekły ołów z baterii odnawiany jest w reaktorze mieszalnikowym okresowym. Niemniej jednak, ważne jest by tak ustawić parametry, żeby ocenić skuteczność mieszania, a co za tym idzie, zwiększyć wydajność w praktykach przemysłowych. Następnie w artykule znajdujemy najlepsze miejsce do iniekcji przy użyciu symulacji dynamiki wodnej w płynie w reaktorze mieszalnikowym ołowiu, dzięki obserwacji ruchów wprowadzonego pierwiastka znaczonego. Różne punkty iniekcji zostały sprawdzone i monitorują pierwiastek znaczony w grupie punktów znajdujących się w reaktorze by zweryfikować mieszanie. Z założenia pierwiastek jest idealny (z tymi samymi właściwościami fizycznymi co ołów). Reaktor jest wsadowy z dwoma geometrycznymi sekcjami – jedną z cylindryczną obudową i drugą o półsferycznym dnie. Wirnik napędza mieszanie ołowiu w wale posiadającym cztery płaskie ostrza. Punkty monitorujące mają uśrednione stężenie pierwiastka w taki sposób, aby ocenić wydajność w całym reaktorze. Wreszcie, jednym z kryteriów wprowadzonych dla odpowiedniej oceny wydajności jest również niezmienność stężenia pierwiastka monitorującego.
Źródło:
Inżynieria Mineralna; 2015, R. 16, nr 1, 1; 25-32
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling Soluble Contaminant Migration by Advection Process in Subsurface Water in the Eastern Niger Delta, Nigeria
Autorzy:
Ugbena, K. G.
Tse, A. C.
Akpokodje, Enuvie G.
Powiązania:
https://bibliotekanauki.pl/articles/1030673.pdf
Data publikacji:
2020
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Aquifer
advective velocity
conservative tracer
migration
soluble contaminant
subsurface water
Opis:
The advective property of an aquifer in the Eastern Niger Delta was evaluated using a conservative tracer. Tracer migration was monitored in observation boreholes at various radial distances simultaneously. Particle size distribution analysis for the sand samples collected from the boreholes in the study site revealed aquifer composition to be predominantly fine sand (silt =13.42%, fine sand = 41.76%, medium sand = 36.71% and coarse sand = 8.09%) for the 8m depth sampled. This field tracer test thus, provides a definitive data on the simultaneous transport of a soluble contaminant and allows a quantitative appraisal of the advective property of the study site. The mean velocity determined 1.212×10-3 ms-1, represents the advective velocity of groundwater carrying the dissolved tracer substance. This is an indication of how soluble components of hydrocarbon will be transported in the study area. Modeling tracer migration by advection process to estimate where and when a soluble contaminant problem can first be noticed in an environmental matrix and its application in hydrological studies is an effective tool to address problems such as sustainability and uncertainty in groundwater resource system.
Źródło:
World Scientific News; 2020, 139, 2; 102-114
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural radioactivity of coastal sediments as tracer in dynamic sedimentology
Autorzy:
Thereska, J.
Powiązania:
https://bibliotekanauki.pl/articles/146496.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
gamma natural radioactivity
coastal sediments
natural tracer
lithology
sediment dynamics
Opis:
Natural radioactivity of coastal sediments could provide interesting information on sediment dynamics. Natural radioactivity measurements were performed in two areas of the Adriatic Sea littoral of Albanian cost, in the gulfs of Durres and Vlora, where complex studies were carried out in the framework of the maintenance of existing Durres harbour and the design of a new harbour in Vlora. Dynamic mapping of the gamma total radioactivity at the sea bottom sediment was carried out using a 2" × 2" NaI probe. Radiometric data were converted to lithological map, and the sand and silt distribution configuration was interpreted in terms of sediment transport. The obtained results have shown that the natural radioactivity of sediments provides qualitative data about the sediment dynamics. This cost-effective method is recommended to be used as complementary to other tracer techniques for sediment transport in coastal engineering investigations.
Źródło:
Nukleonika; 2009, 54, 1; 45-50
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiotracer experiments and CFD simulation for industrial hydrocyclone performance
Autorzy:
Stęgowski, Z.
Nowak, E.
Powiązania:
https://bibliotekanauki.pl/articles/146834.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
computational fluid dynamics (CFD)
industrial hydrocyclone
selectivity
radioisotope tracer
copper industry
Opis:
Hydrocyclone is a device for solid concentration or selection of solid particles from a liquid-solid mixture. It is widely used in the mineral industry for selection of solid particles from a few to a few hundred micrometers. This paper presents a radiotracer experiment and computational simulation of selection of solid particles in a hydrocyclone of Fi-500 mm, which is used in the industrial copper ore concentration process. The simulation, based on computational fluid dynamics (CFD) techniques, allowed obtaining the velocity and concentration distribution for a real mixture flowing in the hydrocyclone. The mixture was composed of water and nine solid phases of different grain sizes. Finally, the selection curve of solid grains was obtained and compared with the experimental radiotracer results.
Źródło:
Nukleonika; 2007, 52, 3; 115-123
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radon in the dry carbon dioxide spa of Mátraderecske, Hungary
Autorzy:
Sóki, E.
Csige, I.
Powiązania:
https://bibliotekanauki.pl/articles/148459.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dry CO2 spa
mofette
radon
tracer
Opis:
The final product of a post-volcanic activity is the exhalation of low-temperature (<100°C) gases containing mostly carbon dioxide. The phenomenon is called mofettes, which are often used for therapeutic treatments in the form of dry CO2 spas. Along its pathway to the surface, the deep origin gas also intakes different radon isotopes from the rocks and soils; therefore, the risks associated with radon exposures should also be a concern. In this work, we have found that the 222Rn activity concentration in the mofette gas of Mátraderecske is particularly high; it is in the order of 200 kBq•m–3. However, owing to the carefully designed flow pattern of mofette gas and fresh air, the radon level is about 1 kBq∙m–3 at the breath level of the staff, accompanying the treatment, which is the radon reference level for workers in Hungary. We have also found that in this dry spa, radon is a good tracer of CO2; therefore, it can be used to monitor the CO2 distribution in the treatment pools.
Źródło:
Nukleonika; 2016, 61, 3; 245-249
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Study of Anion Exchange Resins Purolite NRW-6000 and Duolite A-143 by Application Isotopic Technique
Autorzy:
Singare, P.U.
Powiązania:
https://bibliotekanauki.pl/articles/411790.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
isotopic technique
tracer isotopes
131I
82Br
resin characterization
industrial grade resins
Purolite NRW-6000
Duolite A-143
Opis:
Isotopic tracer technique using 131I and 82Br was used to characterize Purolite NRW-6000 and Duolite A-143 anion exchange resins. The characterization study was done by carrying out iodide and bromide ion-isotopic exchange reactions taking place between the resin surface and the external labeled ionic solution. For the two resins it was observed that under identical experimental conditions, the values of specific reaction rate (min-1), amount of ion exchanged (mmol) and initial rate of ion exchange (mmol/min) were calculated to be lower for bromide ion-isotopic exchange reaction than that for iodide ion-isotopic exchange reaction. Also during both the ion-isotopic exchange reactions, under identical experimental conditions for the two resins, the values of specific reaction rate increases with increase in ionic concentration and was observed to decrease with rise in temperature. For a constant temperature of 35.0 °C, as the concentration of labeled bromide ion solution increases from 0.001 mol/L to 0.004 mol/L, the percentage of bromide ions exchanged increases from 67.80 % to 72.76 % using Purolite NRW-6000 resin and from 42.54 % to 50.45 % using Duolite A-143 resin. However when the temperature was raised from 30.0 °C to 45.0 °C by keeping the concentration of labeled bromide ion solution constant at 0.002 mol/L, the percentage of bromide ions exchanged decreases from 70.68 % to 67.32 % using Purolite NRW-6000 resin and from 47.50 % to 42.25 % using Duolite A-143 resin. From the results it appears that Purolite NRW-6000 resins show superior performance over Duolite A-143 resins under identical experimental conditions. It is expected that the present isotopic tracer technique can be applied further as an efficient nondestructive technique in characterization of various ion exchange resins so as to bring about their efficient industrial applications.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 12; 1-13
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nondestructive Radioactive Tracer Technique in Characterization of Anion Exchange Resins Purolite NRW-8000 and Duolite A-368
Autorzy:
Singare, P.U.
Powiązania:
https://bibliotekanauki.pl/articles/411749.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
ion-exchange resin
anion exchange
Purolite NRW-8000
Duolite A-368
radio tracer isotopes
131I
82Br
characterization
isotopic Exchange
Opis:
Radioactive tracer isotopes 131I and 82Br were used to characterize anion exchange resins Purolite NRW-8000 and Duolite A-368 by application of nondestructive technique. The resin characterization was based on their performance during iodide and bromide ion-isotopic exchange reactions. It was observed that during the iodide ion-isotopic exchange reaction at a constant temperature of 40.0 °C, as the concentration of labeled iodide ion solution increases from 0.001 mol/L to 0.004 mol/L, the percentage of iodide ions exchanged increases from 62.10 % to 68.10 % using Purolite NRW-8000 resins and from 44.20 % to 46.80 % using Duolite A-368 resins. Also at a constant temperature of 40.0 °C, 1.000 g of ion exchange resins and 0.003 mol/L labeled iodide ion solution, the values of specific reaction rate (min-1), amount of iodide ion exchanged (mmol), initial rate of iodide ion exchange (mmol/min) and log Kd were calculated as 0.260, 0.500, 0.130 and 11.8 respectively for Purolite NRW-8000 resin, which was higher than the respective values of 0.130, 0.345, 0.045 and 6.7 as that obtained for Duolite A-368 resins. The similar trend was observed for the two resins during bromide ion-isotopic exchange reaction. From the overall results it appears that under identical experimental conditions, Purolite NRW-8000 resins show superior performance over Duolite A-368 resins. It is expected here that the present nondestructive technique can be extended further for characterization of different industrial grade ion exchange resins, which will help in their selection for specific industrial application.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 12; 14-27
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Nondestructive Radio Tracer Technique in Performance Evaluation of Anion Exchange Resins Duolite ARA-9366 and Duolite A-171
Autorzy:
Singare, P. U.
Powiązania:
https://bibliotekanauki.pl/articles/412526.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
non-destructive tracer technique
radio analytical technique
radioactive tracer isotopes
131I
82Br
reaction kinetics
ion-isotopic exchange reactions
nuclear grade resin
Duolite ARA-9366
Duolite A-171
Opis:
Radio analytical technique as a non-destructive technique was used in the present investigation to trace the kinetics of ion-isotopic exchange reaction taking place in Duolite ARA-9366 (nuclear grade) and Duolite A-171 (non-nuclear grade) anion exchange resins. The kinetics data suggest that during iodide ion-isotopic exchange reactions under identical experimental conditions of 40.00C, 1.000 g of ion exchange resins and 0.003 M labeled iodide ion solution, the values of specific reaction rate (min-1), amount of iodide ion exchanged (mmol), initial rate of iodide ion exchange (mmol/min) and log Kd were 0.176, 0.383, 0.067 and 7.8 respectively for Duolite ARA-9366 resin, which was higher than 0.142, 0.353, 0.050 and 7.0 respectively as that obtained for Duolite A-171 resins. Also it is observed that at a constant temperature of 40.0 °C, as the concentration of labeled iodide ion solution increases 0.001 M to 0.004 M, the percentage of iodide ions exchanged increases from 49.20 % to 51.80 % for Duolite ARA-9366 resins; and from 45.20 % to 47.80 % for Duolite A-171 resins. The similar trend was observed for the two resins during bromide ion-isotopic exchange reactions. The overall results indicate superior performance of Duolite ARA-9366 resins over Duolite A-171 resins under identical operational parameters.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 13; 63-76
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radio Analytical Nondestructive Technique in Performance Evaluation of Organic Base Ion Exchange Resins Purolite NRW-6000 and Duolite A-378
Autorzy:
Singare, P. U.
Powiązania:
https://bibliotekanauki.pl/articles/412155.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
anion exchange
resins
Purolite NRW-6000
Duolite A-378
isotopic exchange tracer isotopes
131I
82Br
nondestructive technique
Opis:
Nondestructive radioanalytical technique using short lived isotopes 131I and 82Br was used as tracers to study the kinetics of iodide and bromide ion-isotopic exchange reactions. The kinetic data so obtained was used to evaluate the performance of organic base anion exchange resins Purolite NRW-6000 and Duolite A-378. It was observed that for iodide ion-isotopic exchange reaction performed at 40.0 °C using 1.000 g of ion exchange resins and 0.003 mol/L labeled iodide ion solution, the values of specific reaction rate (min-1), amount of iodide ion exchanged (mmol), initial rate of iodide ion exchange (mmol/min) and log Kd were calculated as 0.332, 0.582, 0.193 and 16.2 respectively for Purolite NRW-6000 resin, which was higher than the respective values of 0.210, 0.421, 0.088 and 14.7 as that obtained for Duolite A-378 resins. Also at a constant temperature of 40.0 °C, as the concentration of labeled iodide ion solution increases from 0.001 mol/L to 0.004 mol/L, the percentage of iodide ions exchanged increases from 74.68 % to 79.48 % using Purolite NRW-6000 resins and from 52.30 % to 58.90 % using Duolite A-378 resins. The overall results indicate superior performance of Purolite NRW-6000 resins over Duolite A-378 resins under identical operational parameters. It is expected here that the present technique can be extended further for characterization of different ion exchange resins which will further help in the selection of those reins for the specific industrial application.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 13; 77-89
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the reactive tracer method to study chaotic mixing in a twisted bend mixer
Zastosowanie metody regulującego trasera w badaniu chaotycznego mieszania w mieszalniku rurowym w formie giętych kolan przekręconych naprzemiennie względem siebie
Autorzy:
Rożeń, A.
Kopytowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/2073343.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
laminar flow
chaotic advection
reactive tracer
przepływ laminarny
adwekcja chaotyczna
traser reagujący
Opis:
The paper presents the results of experimental study of reactive laminar mixing in a tubular reactor made up of a succession of pipe bends, alternately rotated by 90° with respect to the preceding bend. A system of competitive parallel reactions: acid-base neutralization and ester hydrolysis were used in the experiments. It was found that selectivity of test reactions depends strongly on the Reynolds number in a range of 80 < Re < 1200. The Dean roll-cells, formed in consecutive pipe bends, periodically change their orientation resulting in chaotic advection and faster mixing. A material processed in this mixer is not exposed to high shear rate or fouling, and pressure drop is low. Such features of an on-line mixer are desirable in the polymer, cosmetic and food industry.
Przedstawiono wyniki badań doświadczalnych mieszania laminarnego z reakcją chemiczną w reaktorze rurowym w formie giętych kolan, przekręconych naprzemiennie względem siebie o kąt 90°. W eksperymentach użyto reakcji konkurencyjnych i równoległych: neutralizacji kwasu zasadą i hydrolizy alkalicznej estru. Wykazano, że selektywność reakcji testowych silnie zależy od liczby Reynoldsa w przedziale 80 < Re <1200. Komórki Deana, powstałe w kolejnych wygiętych odcinkach rur, periodycznie zmieniają swoją orientację, co prowadzi do powstania chaotycznej adwekcji i przyspiesza mieszanie. Materiał nie podlega dużym szybkościom ścinania, nie osadza się na ściankach, a spadek ciśnienia jest niewielki. Takie cechy mieszalnika przepływowego są pożądane w przetwórstwie polimerów, przemyśle kosmetycznym i spożywczym.
Źródło:
Inżynieria i Aparatura Chemiczna; 2018, 3; 77--78
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of resisdence time measurements on heat exchangers for the determination of dispersive Peclet numbers
Autorzy:
Roetzel, W.
Na Ranong, C.
Powiązania:
https://bibliotekanauki.pl/articles/240480.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat exchanger
dispersion model
transient tracer experiment
evaluation method
wymiennik ciepła
model dyspersji
metoda oceny
Opis:
The recently developed special unity Mach number dispersion model prescribes the corrections to heat transfer coefficients which are simple functions of the dispersive Peclet numbers. They can be determined through the residence time measurements. An evaluation method is described in which the measured input and response concentration profiles are numerically Laplace transformed and evaluated in the frequency domain. A characteristic mean Peclet number is defined. The method is also applied to the parabolic dispersion model and the cascade model. A calculated example of a tube bundle with maldistribution and backflow demonstrates the suitability of the evaluation method.
Źródło:
Archives of Thermodynamics; 2014, 35, 2; 103-115
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Towards research on entomopathogenic fungi spray quality depositon and their efficacy with the use of natural dyes
W kierunku badań nad jakością opryskiwania i skutecznością działania grzybów entomopatogenicznych z użyciem naturalnych barwników
Autorzy:
Ratajkiewicz, H.
Szulc, T.
Kierzek, R.
Sytek, A.
Powiązania:
https://bibliotekanauki.pl/articles/950505.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
spray deposition
tracer
surface tension
droplet
conidia
germination
wskaźnik
ciecz opryskowa
napięcie powierzchniowe
kropla
kiełkowanie
zarodniki konidialne
Opis:
The studies evaluated the usefulness of concentrated beetroot juice, chokeberry and beetroot powder as potential tracers of spray deposits as well as their impact on the ability of conidia germination of Isaria fumosorosea and Lecanicillium lecanii. Aqueous solutions of beetroot and chokeberry products affected the physical properties of the spray liquid. The chokeberry juice concentrate at concentration of 2% did not reduced significantly the static surface tension and can be useful as tracer in studies on the quality of spraying. Unfortunately, the chokeberry juice concentrate can be low compatible in mixtures with some adjuvants. Beetroot products lowered significantly static surface tension. Beetroot juice concentrate at a concentration of 2-4% allowed to create stable mixtures with adjuvants and did not influence significantly spreading of droplet. Conidia germination capacity of entomopathogenic fungi was not significantly reduced in solutions of juice concentrates or adjuvants. The mixture of adjuvant and juice concentrate raised the risk of a reduction in ability of conidia germination.
W badaniach oceniono przydatność koncentratu soku z buraka ćwikłowego i aronii oraz proszku buraka ćwikłowego jako potencjalnych wskaźników jakości opryskiwania jak również ich wpływ na zdolność kiełkowania zarodników konidialnych Isaria fumosorosea i Lecanicillium lecanii. Wodne roztwory produktów z buraka ćwikłowego i aronii wpływały na właściwości fizyczne cieczy. Koncentrat soku z aronii w stężeniu 2% nie obniżał znacząco statycznego napięcia powierzchniowego i może pełnić rolę znacznika w badaniach nad jakością opryskiwania. Koncentrat soku z aronii może być jednak niekompatybilny w mieszaninach z niektórymi adiuwantami. Produkty z buraka ćwikłowego obniżały znacząco statyczne napięcie powierzchniowe. Koncentrat soku z buraka ćwikłowego w stężeniu 2-4% umożliwiał uzyskanie stabilnych mieszanin z adiuwantami i nie wpływał znacząco na rozlanie kropli. Zdolność kiełkowania zarodników konidialnych grzybów entomopatogenicznych nie ulegała znaczącemu obniżeniu w roztworach koncentratów soków ani adiuwantów. Połączenie adiuwanta i koncentratu soku podnosiło ryzyko obniżenia zdolności kiełkowania zarodników konidialnych.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2016, 61, 1; 73-78
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies