Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "total station. accuracy" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Determination of angular standard deviation with total stations
Określenie odchylenia standardowego dla kątów mierzonych totalnymi stacjami
Autorzy:
Dzierżęga, A.
Powiązania:
https://bibliotekanauki.pl/articles/385771.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
pomiary kątowe
kolimator
totalna stacja
odchylenie standardowe
weryfikacja hipotez
poziom ufności
ekcentryczność kręgu
angular measurments
collimator
total station. accuracy
standard deviation
hypotheses test procedures
level of significance
circle eccentricity
Opis:
A compact, laboratory based method is introduced that verifies the angular measuring accuracy of surveying instruments. Angular measurements are carried out with collimators. The method has been optimized in regards to meeting stringent space and time requirements. It is suited for service workshops or institutions with limited space available.
W pracy zaprezentowano „metodę laboratoryjną” do określania dokładności pomiarów kątów/kierunków instrumentami geodezyjnymi (total station). Przy pomiarze kątów/kierunków tą metodą korzysta się z kolimatorów lub reflektorów. Metoda ta optymalizuje pomiary ze względu na małą przestrzeń i czas pomiaru. Szczególnie nadaje się dla instytucji (serwis, laboratoria), w których mamy do czynienia z ograniczoną przestrzenią.
Źródło:
Geomatics and Environmental Engineering; 2010, 4, 3; 35-40
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural damage detection of elevated circular water tank and its supporting system using geodetic techniques
Autorzy:
Zeidan, Zaki
Beshr, Ashraf A. A.
Sameh, Sara
Powiązania:
https://bibliotekanauki.pl/articles/145428.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zbiornik na wodę
deformacja
nachylenie
dokładność
tachimetr
water tank
deformation
inclination
accuracy
total station
Opis:
Water is the main source of daily life for everyone and everywhere in the world. Sufficient water distribution depends on the place and design of water tank in certain areas. Water storage tanks are relatively flexible structures and they can tolerate greater settlements than other engineering structures. Deformation of tanks may cause severe damages to tank or even loss of life and injury to people, so monitoring the structural deformation and dynamic response of water tank and its supporting system to the large variety of external loadings has a great importance for maintaining tank safety and economical design of manmade structures. This paper presents an accurate geodetic observations technique to investigate the inclination of an elevated circular water tank and the deformation of its supporting structural system (supporting columns and circular horizontal beams) using reflector-less total station. The studied water tank was designed to deliver water to around 55000 person and has a storage capacity about 750 m3. Due to the studied water tank age, a non-uniform settlement of tank foundation and movement of pumps and electric machines under tank’s body will cause stress and strain for tanks membrane and settlement of sediments. So the studied water tank can tend to experience movement vertically, horizontally or both. Three epochs of observations were done (July 2014, September 2014 and December 2014). The results of the practical measurements, calculations and analysis of the interesting deformation of the studied elevated tanks and its supporting system using least squares theory and computer programs are presented. As a results of monitoring the water storage tank, circular reinforced concrete beams and columns at three monitoring epochs. The body of water storage tank has an inclination to the east direction and the value of inclination is increased with the time.
Źródło:
Geodesy and Cartography; 2020, 69, 1; 117-140
2080-6736
2300-2581
Pojawia się w:
Geodesy and Cartography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uwagi o wykorzystaniu tachimetrów bezlustrowych w inwentaryzacji architektonicznej
Some remarks concerning the use of reflectorless total stations for architectural recording
Autorzy:
Klimkowska, H.
Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/1050662.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
inwentaryzacja architektoniczna
dokładność pomiaru
tachimetr
bezlustrowy pomiar odległości
object documentation
accuracy of distance measurement
total station
reflectorless distance measurement
Opis:
W ostatnich latach obserwuje się szybki rozwój instrumentów wykorzystujących pomiar odległości bez konieczności stosowania luster. Przeprowadzono badania, które wykazały, że dokładność pomiaru odległości do płaskich i równych ścian wynosi około ±3 mm Z dotychczasowych doświadczeń stosowania takich tachimetrów w pomiarach inwentaryzacyjnych wynika, że pojawiają się problemy z dokładnością pomiaru narożników obiektu. Pomiar odległości odbywa się, bowiem za pomocą wiązki lasera, która daje na obiekcie plamkę o średnicy kilka do kilkudziesięciu mm w zależności od odległości. Odległość jest mierzona nie do punktu, a do pewnej powierzchni. Powoduje to błędy w pomiarze odległości do narożników. Z przeprowadzonych przez autorów badań wynika, że pomiar odległości do narożnika wklęsłego charakteryzuje się błędem systematycznym zmniejszającym wartość odległości o kilka mm (efekt zaokrąglenia narożnika). Pomiar narożników wypukłych jest obarczony podobnym błędem na plus, ale pod warunkiem, że cała wiązka lasera odbija się od bliskiego otoczenia narożnika. Jeżeli celujemy na narożnik tak, iż część wiązki trafia obok narożnika i odbija się od dalszych obiektów, błędy pomiaru odległości mogą wynosić od kilkunastu do kilkudziesięciu mm, a czasami nawet więcej.
In recent years, there has been rapid progress of instruments which are able to measure distance without using reflectors. This method of measurement has been adopted in laser scanners and in some total stations. The range of distance measurement, as well as its accuracy, make it useful for architectural measuring purposes. According to the producers’ information, the accuracy of distance measurement with reflectorless total stations varies between 3 and 5 mm, with the range of measurement up to 1 200 m. The accuracy of object documentation required by Polish technical standards (G-3.4) is 1÷3 cm (for well-preserved objects) – thus, the usage of reflectorless total stations fulfills the accuracy requirements. Experiments using reflectorless total stations in architectural documentation measurements show some problems with pointing onto the wall-corner points. The distance measurement take place with a laser bundle, which illuminates a spot on the object’s surface. The size of the spot is a dozen or so for 50m distance from object, and it increases along with the distance from the object. This means that the resulting measuring distance is the average of the spot surface distances. When the measuring point is the corner of a wall, such an average distance does not match the proper corner point distance. There are two cases of corners (convex or concave corner) and the results of measurements are different for both of them. In case of concave corners, the average distance of the spot is smaller than the real corner distance. The test measurements shows, that this difference is not greater than a few millimeters. Such a difference can be disregarded. The worse case is with convex corners – part of the spot can touch further objects, so the result can differ more, from over a dozen up to several dozen millimeters (max. 130 mm). In such cases, a good solution could be achieved with a proper method of pointing – the whole spot should touch the wall, close to the corner. The result of test measurements (with the execution of pointing requirements) gives the standard deviation of the measured distance ca ±3 mm. Such accuracy proves that reflectorless total stations can be used not only for direct documentation measurements, but also for determination of photogrammetric control points (signalized or not).
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2006, 16; 297-303
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of horizontal accuracy of the large-scale digital maps
Ocena dokładności opracowania sytuacyjnego wielkoskalowych map cyfrowych
Autorzy:
Doskocz, A.
Dąbrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/385819.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wielkoskalowe mapy cyfrowe
dokładność opracowania sytuacyjnego
pomiar kontrolny
tachimetr elektroniczny
large-scale digital maps
horizontal accuracy
control surveying
total station
Opis:
Today, government and self-government institutions as well as businesses deploy spatial information in the broadly defined concept of management. This is realized by theoretical and practical efforts supporting the development and updating of digital map databases and their effective and rational (preceded by an analysis of their quality) application for execution of economic tasks. The paper presents estimation of horizontal accuracy of digital maps produced by means various methods: new total station survey (object A), recalculation of previous direct measurements (orthogonal and polar surveys) (object B), manual vectorisation of a raster orthophotomap image (object C) and graphical-and-digital processing of analogue maps (object D). Carried out investigations shown that digital data produced by various methods do not always support the development of geodetic documentation at the required accuracy level. The authors postulate the need to estimate the accuracy of the databases of large-scale maps to ensure the transparency of relations between map producers and map users, and to guarantee that national geodetic and cartographic resources meet the relevant quality standards.
Obecnie instytucje rządowe i samorządowe oraz firmy efektywnie wykorzystują informacje przestrzenne w szeroko pojętym zarządzaniu. Realizację tych celów wspierają teoretyczne i praktyczne wysiłki w zakresie opracowywania i aktualizacji baz danych map cyfrowych oraz ich efektywnego i racjonalnego (poprzedzonego analizą ich jakości) wykorzystania w wykonywaniu zadań gospodarczych. Niniejsza praca przedstawia ocenę dokładności opracowania sytuacyjnego wielkoskalowych map cyfrowych wykonanych przy wykorzystaniu różnych metod pozyskania danych sytuacyjnych, takie jak: nowy pomiar tachimetrem elektronicznym (obiekt A), przeliczenie wyników wcześniejszych pomiarów bezpośrednich (ortogonalnych i biegunowych) (obiekt B), manualna wektoryzacja rastrowego obrazu ortofotomapy (obiekt C) oraz przetworzenie graficzno-numeryczne map analogowych (obiekt D). Wyniki badań wykazały, że dane pozyskane różnymi metodami nie zawsze zapewniają opracowanie dokumentacji geodezyjnej na wymaganym poziomie dokładności. Autorzy zauważają potrzebę wykonywania ocen dokładności baz danych map wielkoskalowych w celu zapewnienia klarownych relacji pomiędzy wykonawcami i użytkownikami map oraz zagwarantowania standardów jakości państwowego zasobu geodezyjnego i kartograficznego.
Źródło:
Geomatics and Environmental Engineering; 2011, 5, 1; 37-48
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies