Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "total knee arthroplasty" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Anatomical knee endoprostheses – does a better-fit lead to better outcomes? A review article
Endoprotezy anatomiczne stawu kolanowego – czy lepsze dopasowanie to lepsze wyniki? Praca przeglądowa
Autorzy:
Maciąg, Bartosz Michał
Budzińska, Martyna
Żarnovsky, Krystian
Adamska, Olga
Stolarczyk, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2186040.pdf
Data publikacji:
2023-03-31
Wydawca:
Wydawnictwo Exemplum
Tematy:
total knee arthroplasty
anatomic knee prosthesis
morphometric implants
całkowita endoprotezoplastyka stawu kolanowego
implanty anatomiczne
implanty morfometryczne
Opis:
Introduction. Total knee replacement is the most efficient method of treating end-stage osteoarthritis of the knee joint. The surgery aims to relieve patients of pain, restore range of motion and improve patients’ quality lives. Prostheses design is still being modified and improved through cooperation between orthopaedic surgeons and engineers. Some of the most modern solutions aimed to fit native patients’ anatomy as much as possible are anatomic knee systems. Materials and methods. The literature was reviewed, and articles related to the subject were researched. Therefore, publications including keywords such as total knee replacement, anatomic implants and morphometric implants were searched in the PubMed, Cochrane and Google Scholar databases. All data was selected and verified individually. Analysis and synthesis of studies were prepared separately. Results. Many studies describe the advantages of anatomic prostheses over standard prostheses. Anatomical prostheses have a broader range of available sizes, thus providing better coverage of the distal end of the femur and the proximal tibia, allowing for the resection of less bone tissue, which is beneficial in the event of a possible need for a future revision of the endoprosthesis, enabling better selection of the tibial element rotation by better matching to the tibial plateau, which affects the alignment and patellar movement, and the structure of the trochlear geometry that also affects the patellar movement and reduces the risk of trochlear dysplasia. Conclusions. Anatomical implants enable better alignment of the prosthesis elements and the native femoral and tibial bone. Using these models makes it possible to obtain a greater range of motion and, consequently, improved functional outcomes compared to non-anatomical ones. It also enables less bone resection and better radiological outcomes.
Wstęp. Endoprotezoplastyka całkowita stawu kolanowego jest uznawana za najskuteczniejszą metodę leczenia zaawansowanej choroby zwyrodnieniowej stawu kolanowego. Celem operacji jest zmniejszenie bólu kolan, przywrócenie zakresu ruchu i poprawa jakości życia pacjentów. Projekt protez jest wciąż modyfikowany i udoskonalany dzięki współpracy ortopedów i inżynierów. Jednymi z najnowocześniejszych rozwiązań mających na celu maksymalne dopasowanie do anatomii pacjentów są anatomiczne systemy kolanowe. Materiał i metody. Dokonano przeglądu literatury i przeanalizowano artykuły związane z tą tematyką. W bazach PubMed, Cochrane i Google Scholar przeszukano publikacje zawierające słowa kluczowe takie jak całkowita endoprotezoplastyka stawu kolanowego, implanty anatomiczne, implanty morfometryczne. Wszystkie dane zostały dobrane i zweryfikowane indywidualnie. Analizę i syntezę badań przygotowano osobno. Wyniki. Wiele artykułów opisuje przewagę protez anatomicznych nad modelami protez standardowych. Protezy anatomiczne posiadają szerszy wachlarz dostępnych rozmiarów przez co oferują lepsze pokrycie dalszego końca kości udowej oraz bliższego piszczelowej, pozwalają na resekcję mniejszej ilości tkanki kostnej co jest korzystne w przypadku możliwej w przyszłości konieczności rewizji endoprotezy, umożliwiają lepsze dobranie rotacji elementu piszczelowego przez lepsze dopasowanie do plateau piszczeli co wpływa na alignment i tor ruchu rzepki, a także budowa bruzdy dla rzepki wpływa korzystnie na tor ruchu rzepki i zmniejsza ryzyko rozwoju dysplazji. Wnioski. Implanty anatomiczne umożliwiają lepsze dopasowanie elementów protezy do natywnej struktury kości. Dzięki zastosowaniu tych modeli możliwe jest uzyskanie większego zakresu ruchu w stawie, a w rezultacie lepszych wyników funkcjonalnych. Implanty anatomiczne pozwalają także na mniejszą resekcję tkanki kostnej.
Źródło:
Chirurgia Narządów Ruchu i Ortopedia Polska; 2023, 88, 1; 13-16
0009-479X
2956-4719
Pojawia się w:
Chirurgia Narządów Ruchu i Ortopedia Polska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Assessment of Factors That Influence Outcome Following Fixation of Periprosthetic Distal Femur Fractures Associated with Total Knee Arthroplasty
Autorzy:
Fakoya, Keji
Sedarous, Ramy
Seifo, Mina
Okoro, Tosan
Powiązania:
https://bibliotekanauki.pl/articles/28409185.pdf
Data publikacji:
2022-07-01
Wydawca:
Fundacja Edukacji Medycznej, Promocji Zdrowia, Sztuki i Kultury Ars Medica
Tematy:
periprosthetic fractures
distal femur
total knee arthroplasty
functional outcome
Opis:
Background. Periprosthetic distal femur fractures following total knee arthroplasty (PDFFTKA) are increasingly common [1], mainly in elderly patients with significant co-morbidities [2]. Surgical management usually requires balancing prompt fixation for early mobilization with the need to consider the least physiologically demanding option [3].The aim of this study was to assess predictors of clinical and radiological outcome in patients with PDFFTKA treated with open reduction and internal fixation (ORIF). Materials and methods. A retrospective cohort study of patients managed for PDFFTKA over the last 21 years in the Trauma & Orthopaedics Department of the Royal Shrewsbury Hospital (RSH) was carried out. Radiological images, pre- and post-operatively, were assessed for fracture related parameters. Last known functional status was evaluated using the most recent outpatient review letters. After assessment of normality of data, evaluation of predictors of clinical and radiological outcome was made using correlation analyses. Results. There was no statistically significant correlation between age, primary TKA to fracture interval, and length of intact medial cortex vs clinical outcome for the parametric variables evaluated. For non-parametric variables assessed, there was a statistically significant correlation between clinical outcome and evidence of callus formation (Spearman rho value -0.476; p=0.022). In stratifying the patients with ‘poor’ and ‘good’ outcome, there was no difference noted in primary TKA to fracture interval, or length of intact medial cortex (mm) between both groups. In terms of the number of comminuted fragments and anterior flange to fracture distance (mm), there was also no difference noted between the ‘poor’ and ‘good’ functional groups. Conclusions. 1. There was no observed correlation in pre-operative patient and fracture related variables with outcome in this population of patients with PDFFTKA. 2. Post-operative evidence of callus formation appears to be directly related to better clinical outcomes.
Źródło:
Ortopedia Traumatologia Rehabilitacja; 2022, 24(3); 193-199
1509-3492
2084-4336
Pojawia się w:
Ortopedia Traumatologia Rehabilitacja
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pain management in total knee arthroplasty. A comprehensive review
Leczenie bólu po zabiegu całkowitej endoprotezoplastyki stawu kolanowego. Kompleksowy przegląd badań
Autorzy:
Domagalska, Małgorzata
Reysner, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2191578.pdf
Data publikacji:
2022-12-30
Wydawca:
Wydawnictwo Exemplum
Tematy:
total knee arthroplasty
multimodal analgesia
pain
IPACK block
adductor canal block
periarticular injections
całkowita endoprotezoplastyka kolana
analgezja multimodalna
ból
blokada IPACK
iniekcje okołostawowe
blokada kanału przywodzicieli
Opis:
Total knee arthroplasty (TKA) is one of the most common surgeries performed to relieve joint pain in patients with end-stage osteoarthritis or rheumatic arthritis of the knee. However, TKA is followed by moderate to severe postoperative pain that affects postoperative rehabilitation, patient satisfaction, and overall outcomes. Historically, opioids have been widely used for the perioperative pain management of TKA. However, opioids are associated with undesirable adverse effects, such as nausea, respiratory depression, and urine retention, which limit their application in daily clinical practice. This review aimed to discuss the current postoperative pain management regimens for TKA. Our review of literature demonstrated that multimodal analgesia is considered the optimal regimen for perioperative pain management of TKA and improves clinical outcomes and patient satisfaction, through a combination of several types of medications, including preemptive analgesia, especially local infiltration analgesia and peripheral nerve blockade. Multimodal analgesia provides superior pain relief, promotes knee recovery, and reduces opioid consumption and related adverse effects in patients undergoing TKA.
Całkowita alloplastyka stawu kolanowego (TKA) jest jedną z najczęściej wykonywanych operacji w celu złagodzenia bólu stawów kolanowych u pacjentów ze schyłkową chorobą zwyrodnieniową lub reumatycznym zapaleniem stawu kolanowego. Ból pooperacyjny występujący po alloplastyce stawu kolanowego ma nasilenie od umiarkowanego do ciężkiego, co wpływa na rehabilitację pooperacyjną, zadowolenie pacjenta i ogólne wyniki leczenia. W przeszłości opioidy były szeroko stosowane w leczeniu bólu okołooperacyjnego po TKA. Jednak stosowanie opioidów wiąże się z różnymi działaniami niepożądanymi, takimi jak nudności, depresja oddechowa czy zatrzymanie moczu, co ogranicza ich zastosowanie w codziennej praktyce klinicznej. Celem tej pracy było omówienie aktualnych schematów leczenia bólu pooperacyjnego po TKA. Nasz przegląd piśmiennictwa wykazał, że analgezja multimodalna jest uważana za optymalny sposób leczenia bólu okołooperacyjnego po TKA. Ta metoda leczenia dzięki połączeniu kilku rodzajów leków o różnych mechanizmach działania, a także stosowaniu analgezji z wyprzedzeniem, a zwłaszcza analgezji regionalnej, ze szczególnym uwzględnieniem blokad nerwów obwodowych, zapewnia doskonałą ulgę w bólu, sprzyja regeneracji stawu kolanowego oraz zmniejsza zużycie opioidów i związane z nimi działania niepożądane u pacjentów poddawanych TKA.
Źródło:
Chirurgia Narządów Ruchu i Ortopedia Polska; 2022, 87, 4; 173-180
0009-479X
2956-4719
Pojawia się w:
Chirurgia Narządów Ruchu i Ortopedia Polska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The return to professional activity patients treated surgically due to advanced gonarthrosis
Autorzy:
Drobniewski, Marek
Synder, Marek
Krasińska, Magdalena
Sibiński, Marcin
Borowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2095506.pdf
Data publikacji:
2021-09-03
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
total knee arthroplasty
gonarthrosis
return to work
clinical and radiological outcome
Knee Society Score
Kellgren-Lawrence classification
Opis:
ObjectivesThe goal of this work is to analyze the issue of return to professional activity by working-age patients who have been treated surgically with total knee arthroplasty (TKA) due to gonarthrosis.Material and MethodsOverall, 88 working-age patients were examined, with a total of 91 TKA procedures performed due to advanced gonarthrosis. The average age of the patients was 54.2 years for women and 58.1 years for men. A modified Knee Society Score scale was used to compile the results of the clinical trial. The Kellgren-Lawrence classification was used to assess preoperative radiographs. Postoperative radiographs evaluated the position of the endoprosthesis of both the femoral and tibial components in the anteriorposterior and lateral upright projections. The obtained results were subjected to statistical analysis.ResultsIn the preoperative assessment, both the clinical and radiological results obtained were unfavorable in all cases. Throughout the observation period of approximately over 3.8 years, a very good result was noted in 65 cases (71.4%), a good result in 20 cases (22%), and a satisfactory result in 6 cases. There were no bad results. The average improvement on the Visual Analogue Scale was 6.5 pts. The radiological assessment did not reveal any radiological symptoms of the aseptic loosening of the endoprosthesis, simultaneously concluding that each time the endoprosthesis components were properly seated. Only 53 (58.3%) of the examined patients were professionally active before the surgery. After completing the treatment, 46 (50.5%) of all patients returned to work, in favor of intellectual workers. The average duration of sick leave was 136.2 days, and rehabilitation allowance was granted in 19 cases.ConclusionsFirstly, in working-age patients, TKA is a valuable method for surgical treatment of advanced gonarthrosis of varying etiology. Secondly, most of the patients who worked before the surgery returned to performing work in the position held and on the same full-time equivalent basis.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2021, 34, 5; 617-628
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two-stage Reimplantation in Infected Total Knee Arthroplasty by Using Resterilized Femoral and Tibial Components with a New Polyethylene Insert: Report of 4 Cases with at Least 15 Years’ Follow-up
Autorzy:
Öztürk, Alpaslan
Çevik, Nazan
Akalın, Yavuz
Çetin, Oğuz
Avci, Özgür
Kaya, Ali Ömer
Powiązania:
https://bibliotekanauki.pl/articles/28411803.pdf
Data publikacji:
2021-12-20
Wydawca:
Fundacja Edukacji Medycznej, Promocji Zdrowia, Sztuki i Kultury Ars Medica
Tematy:
total knee arthroplasty
periprosthetic infection
articulating spacer
complications
Opis:
Background. This study evaluates 15 years’ results of the implantation of autoclaved femoral and tibial prosthesis components together with a new same brand polyethylene insert which were used as a temporary articulating spacer in patients with periprosthetic infection of total knee arthroplasty (TKA) in a two-stage reimplantation procedure in 6 patients.  Material and methods. The femoral and tibial prostheses of 6 patients with deep chronic periprosthetic infection of TKA who underwent elective two-stage exchange arthroplasty were autoclaved and reinserted with a new polyethylene insert of the same brand and bone cement mixed with tecoplanin in 2004. Results. Four patients were followed for 15 years. They were all female and between 47-70 years old. The infectious agent was meticillin-resistant Staphylococcus aureus (MRSA) in 3 and coagulase negative Staphylococcus in one patient. Patients were invited for second stage reimplantation, but they refused to undergo the second stage. Three of them had their second stage reimplantation after 15, 13 and 10 years while one patient was reinfected after 5 years, in 2009, and arthrodesis was performed. They were all happy with the result and infection free at last follow-up.  Conclusions. 1. Regarding the results of our patients, reinsertion of autoclaved femoral and tibial prostheses together with a new same brand polyethylene insert with teicoplanin loaded bone cement can be used cautiously in the management of periprosthetic deep infection of TKA. 2. That is because patients might not want the second stage reimplantation. 3. We believe that the refusal of patients to undergo the surgery shows that the single-stage treatment is effective.
Źródło:
Ortopedia Traumatologia Rehabilitacja; 2021, 23(6); 411-416
1509-3492
2084-4336
Pojawia się w:
Ortopedia Traumatologia Rehabilitacja
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the patellar button thickness on the knee flexion after total knee arthroplasty
Autorzy:
Rosso, I.
Surface, C.
Antonaci, P.
Surface, F. M.
Negretto, R. J.
Powiązania:
https://bibliotekanauki.pl/articles/949740.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
rzepka
kąt zgięcia
osteoartroza
endoprotezoplastyka całkowita stawu kolanowego
modelowanie
osteoarthritis
total knee arthroplasty
patellar button
flexion angle
modeling
Opis:
One of the main problems of knee replacement is the limit of knee flexion. This study focuses on the knee implant and the patellar component currently in use in total knee arthroplasty, analyzing the influence of patellar thickness on the degree of knee flexion following surgery. Methods: A kinematics study was performed to evaluate whether an optimal patellar thickness can be identified, which enables the maximum flexion angle to be achieved. Using TC images, a healthy model was built. On this basis, a model of a knee joint which had undergone total knee arthroplasty using a Legion PS prosthesis was constructed. Initially, the standard thickness of patellar implant (9 mm) was used to build the model; then several different patellar implant thicknesses (in the range of 5–15 mm) were analyzed. Results: The results show a non-linear trend: a button thickness of less than 9 mm does not change the flexion angle, whereas a button thickness of over 9 mm results in a loss of flexion. The flexion loss is significant in the first two additions of thicknesses but negligible in the last ones. Conclusions: In the case studied, flexion reduction is not linearly proportional to the patellar thickness. The outcome of total knee arthroplasty is considered to be satisfactory with the standard patellar button. The results of this study could be used to compare the kinematics with other total prosthesis and patellar implants, and should enable the optimization of the patellar residue bone thickness to obtain deep flexion.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 121-134
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinematic gait parameters changes in patients after total knee arthroplasty : Comparison between cruciate-retaining and posterior-substituting design
Autorzy:
Hajduk, G.
Nowak, K.
Sobota, G.
Kusz, D.
Kopeć, K.
Błaszczak, E.
Cieliński, Ł.
Bacik, B.
Powiązania:
https://bibliotekanauki.pl/articles/306649.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw kolanowy
endoprotezoplastyka
analiza lokomocji
total knee arthroplasty
gait analysis
cruciate retaining
posterior substituting
Opis:
Purpose: The patients expect optimal knee function after Total Knee Arthroplasty. It is necessary to apply appropriate surgical technique and supervised physical therapy. The optimal management of posterior cruciate ligament remains controversial. Both implant designs, i.e., cruciate retaining and posterior substituting, allow the orthopedic surgeon to achieve excellent clinical outcomes, as measured by commonly used questionnaires. Such methods of assessment may poorly reflect the functional status of patients. Therefore, three-dimensional gait analysis is recommended to evaluate the outcomes of surgical intervention. This study sought to determine differences in kinematic gait parameters and Knee Society Score between cruciate-retaining and posterior-substituting patients. Methods:23 individuals after cruciate-retaining total knee arthroplasty and 19 individuals after posterior-substituting total knee arthroplasty were subjected to gait analysis using three-dimensional motion capture system BTS Smart DX 7000. In addition, gait was assessed in 21 patients with knee osteoarthritis and in 30 healthy individuals. Results: The study did not reveal differences between cruciate-retaining and posterior-substituting groups, both in terms of Knee Society Score and kinematic gait parameters. There were also no differences in kinematic gait parameters between patients from the knee osteoarthritis group and total knee arthroplasty groups. The analyzed parameters in all of the groups differed significantly from those found in healthy individuals. Conclusions: Surgical technique and implant design do not affect values of kinematic gait parameters evaluated under natural walking speed. Several months after surgery the patients still demonstrated alterations in gait pattern, similar to those recorded in patients with knee osteoarthritis.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 137-142
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie własnej skali oceny sprawności sensomotorycznej u pacjentów z gonartrozą i po endoprotezoplastyce stawu kolanowego
Usefulness of a new sensorimotor control scale in patients with gonarthrosis and after total knee replacement
Autorzy:
Słupik, Anna
Kowalski, Marcin
Białoszewski, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/437600.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
propriocepcja
endoprotezoplastyka stawu
kolanowego
aloplastyka
choroba zwyrodnieniowa sensomotoryka
kontrola sensomotoryczna
proprioception
total knee replacement
arthroplasty
knee osteoarthritis
sensorimotor system
sensorimotor control
Opis:
Wstęp. Coraz większą uwagę w praktyce klinicznej zwraca się na ocenę sprawności sensomotorycznej jako istotnego czynnika determinującego powrót funkcji. Celami niniejszej pracy były: ocena wpływu uszkodzeń związanych z zaawansowaną gonartrozą na zmianę czucia głębokiego i kontroli sensomotorycznej stawu kolanowego, porównanie wyników uzyskanych we własnym teście kontroli sensomotorycznej z obiektywnymi metodami oceny czucia głębokiego, analiza zależności pomię- dzy poziomem czucia głębokiego i sprawnością układu sensomotorycznego a pomiarami stosowanymi w praktyce klinicznej. Materiał i metody. Ocenie poddano grupę osób zdrowych (grupa kontrolna, n=74), grupę pacjentów z chorobą zwyrodnieniową IV st. (grupa 1, n=67) oraz pacjentów po endoprotezoplastyce stawu kolanowego (grupa 2, n=62). Badanych oceniano z wykorzystaniem autorskiego Testu Kontroli Sensomotorycznej (TKS) oraz testu czucia pozycji stawu (JPS). Analizowano również wyniki uzyskane w skalach HSS Knee Score i Stafflstein-Score.Wyniki. W ocenie za pomocą TKS i JPS grupa kontrolna uzyskała wyniki na poziomie odpowiednio 4,9 pkt i 3,9°, natomiast grupa 2 3,7 pkt i 6,7° (p<0,005). W grupie 1 uzyskano 3,2 pkt w TKS, natomiast w JPS 8,2° w kończynie zdrowej i 10,2° w kończynie chorej. Wyniki tej grupy były istotnie gorsze niż grupy kontrolnej oraz grupy 2 (p<0,005). Wnioski. 1. Prezentowany własny test oceniający sprawność sensomotoryczną stawu kolanowego wydaje się obiektywnym i kompleksowym sposobem oceny sprawności kontroli sensomotorycznej stawu kolanowego u pacjentów z gonartrozą i po endoprotezoplastyce stawu kolanowego. 2. Wskazane są dalsze badania z wykorzystaniem autorskiego testu kontroli sensomotorycznej obejmujące próbę jego obiektywizacji z wykorzystaniem specjalistycznych narzędzi pomiarowych.
Introduction. The importance of sensorimotor control assessment as a crucial factor determining functional recovery is being increasingly appreciated in clinical practice. The aim of this study was to assess the inflence of damage associated with severe gonarthrosis on changes in proprioception and sensorimotor control of the knee, compare the results of a new sensorimotor control test developed by the authors with objective methods of proprioception assessment, and analyse the relation between the level of proprioception and sensorimotor system function and the measurements used in clinical practice. Material and methods. We studied a group of healthy persons (control group, n=74), patients with stage 4 knee osteoarthritis (group 1, n=67), and patients after total knee arthroplasty (group 2, n=62). The participants were assessed with a new sensorimotor control test (TKS) and a joint position sense test (JPS). Moreover, we analysed the patients’HSS knee scores and Stafflstein scores.results. In the Control Group, mean TKS and JPS test scores were 4.9 pts and 3.9°, respectively, while the respective results in group 2 were 3.7 pts and 6.7° (p<0.005). In group 1, the TKS score was 3.2 pts and the JPS test result was 8.2° in the unaffcted limb and 10.2° in the affcted limb. The results of this group were signifiantly worse than the scores achieved in the control group and group 2 (p<0.005). conclusions. 1. The new knee sensorimotor control test developed by the present authors appears to provide an objective and comprehensive method to evaluate sensorimotor control of the knee in patients with gonarthrosis and after total knee replacement. 2. Further studies of the new test are advised, including an objective evaluation of the test utilising specialised measuring tools.
Źródło:
Medical Review; 2015, 2; 95-103
2450-6761
Pojawia się w:
Medical Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efekty usprawniania pacjentów po endoprotezoplastyce stawu kolanowego w zależności od typu zastosowanego implantu
Results of physiotherapeutic treatment of patients after knee-joint endoprothesoplastic burgery depending on the type of the implant
Autorzy:
Skiba, M.
Skiba, G.
Czerner, M.
Króliński, J.
Powiązania:
https://bibliotekanauki.pl/articles/261141.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
staw kolanowy
zmiany zwyrodnieniowe
endoprotezoplastyka całkowita stawu kolanowego
endopimplanty jedno- i wieloosiowe
fizjoterapia
zakres ruchomości
knee
arthrosis
total knee arthroplasty
single- and multi-axis implants
physiotherapy
range of motion
Opis:
Endoprotezoplastyka jest obecnie podstawową metodą leczenia osób z zaawansowanymi zmianami zwyrodnieniowymi stawu kolanowego. Głównym celem zabiegu jest redukcja dolegliwości bólowych, poprawa zakresu ruchomości oraz przywrócenie stabilności stawu, co ma doprowadzić do polepszenia jakości życia chorych. Celem pracy była ocena efektów usprawniania pacjentów po wszczepieniu jedno- lub wieloosiowej endoprotezy stawu kolanowego. Badaniem objęto grupę 60 osób (45 kobiet i 15 mężczyzn) z zaawansowaną gonartrozą. Średnia wieku wynosiła 66,4 lata. 30 pacjentom wszczepiono jednoosiową endoprotezę SCORPIO CR a pozostałym 30 pacjentom endoprotezę wieloosiową PFC SIGMA. We wszystkich przypadkach zachowano więzadło krzyżowe tylne PCL (ang. Posterior Cruciate Ligament). Program leczenia usprawniającego we wczesnym okresie pooperacyjnym był taki sam u wszystkich chorych. Po około 3 miesiącach od zabiegu pacjenci byli usprawniani na Oddziale Rehabilitacji Narządu Ruchu przez okres 3 tygodni, korzystając z odpowiednio dobranego programu kinezy- i hydroterapii. Oceny zakresu ruchomości stawu kolanowego dokonano przed zabiegiem operacyjnym oraz po zakończeniu rehabilitacji. Wyniki wskazują na poprawę zakresu zgięcia oraz wyprostu operowanego stawu, zarówno u pacjentów z jedno-, jak i wieloosiowym implantem.
Total arthroplasty is currently the main treatment of patients with advanced knee degeneration. The basic goal of the surgery is to reduce pain, improve range of motion (ROM), restore join stability, what can lead to the improved quality of life.The aim of this study was to examine the effects of rehabilitation of patients after single- or multi-axis total knee arthroplasty (TKA). The research was performed on a group of 60 people (45 women and 15 men) with advanced gonarthrosis (mean age 66,4 years). In 30 patients single-axis SCORPIO CR prostheses and in 30 multi-axis PFC Sigma prostheses, were implanted. In all cases the posterior cruciate ligament (PCL) has been retained. Physical therapy in the immediate postoperative period was the same in all groups. The patients were exposed to kinesi- and hydrotherapy 3 months after surgery. The functional status of the knee before surgery and after rehabilitation, were evalutaed. It was stated that the knee flexion and extension were improved. There was no significant difference between these 2 groups.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2013, 19, 2; 104-107
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies