Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tomography" wg kryterium: Temat


Tytuł:
Comparing methods of image reconstruction in electrical impedance tomography
Autorzy:
Rymarczyk, T.
Filipowicz, S.F.
Sikora, J.
Powiązania:
https://bibliotekanauki.pl/articles/97630.pdf
Data publikacji:
2011
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
impedance tomography
electrical impedance tomography
EIT
Opis:
The problem of the image reconstruction in Electrical Impedance Tomography (EIT) is a highly ill-posed inverse problem. There are mainly two categories of image reconstruction algorithms, the direct algorithm and the iterative algorithm which was used in this publication. This paper presents the applications of the level set function for identification the unknown shape of an interface motivated by Electrical Impedance Tomography (EIT) by using a several level set algorithms. The conductivity values in different regions are determined by the finite element method. The applications were based on the level set method, the variational level set algorithm and the Mumford-Shah algorithm to solve the inverse problem.
Źródło:
Computer Applications in Electrical Engineering; 2011, 9; 23-33
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis for Improvement of Doppler Tomography Imaging of Objects Scattering Continuous Ultrasonic Waves
Autorzy:
Świetlik, Tomasz
Opieliński, Krzysztof J.
Powiązania:
https://bibliotekanauki.pl/articles/176449.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
continuous wave ultrasonic tomography
Doppler tomography
image reconstruction
Opis:
The paper describes an innovative ultrasound imaging method called Doppler Tomography (DT), otherwise known as Continuous Wave Ultrasonic Tomography (CWUT). Thanks to this method, it is possible to image the tissue cross-section in vivo using a simple two-transducer ultrasonic probe and using the Doppler effect. It should be noted that DT significantly differs from the conventional ultrasound Doppler method of measuring blood flow velocity. The main difference is that when measuring blood flow, we receive information with an image of the velocity distribution in a given blood vessel (Nowicki, 1995), while DT allows us to obtain a cross-sectional image of stationary tissue structure. In the conventional method, the probe remains stationary, while in the DT method, the probe moves and the examined tissue remains stationary. This paper presents a method of image reconstruction using the DT method. First, the basic principle of correlation of generated Doppler frequencies with the location of inclusions from which they originate is explained. Then the exact process and algorithm in this method are presented. Finally, the impact of several key parameters on imaging quality is examined. As a result, the conclusions of the research allow to improve the image reconstruction process using the DT method.
Źródło:
Archives of Acoustics; 2020, 45, 2; 329-339
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu niedokładności równoległych torów pomiarowych na dokładność rekonstrukcji przewodności w tomografii elektrycznej
Uncertainty influence investigation of the measurement parallel channels on the reconstruction conductivity accuracy in electrical tomography
Autorzy:
Dorozhovets, M.
Prygrodsky, A.
Brydak, K.
Powiązania:
https://bibliotekanauki.pl/articles/155984.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tomografia impedancyjna
electrical tomography
Opis:
W pracy przedstawiono analizę wpływu oddziaływań addytywnych oraz multiplikatywnych w torze pomiaru napięć międzyelektrodowych na dokładność rekonstrukcji rozkładu przestrzennego przewodności w tomografii elektrycznej (TE). Przedstawiono ogólną zasadę konstruowania obrazu TE, metodę pomiarową realizującą równoległy pomiar napięć międzyelektrodowych oraz algorytm rekonstrukcji obrazu przewodności.
The influence analysis of additive and multiplicative interactions in measuring system of inter-electrode voltages on accuracy of reconstruction of conductivity spatial distribution in electrical tomography has been presented in this paper. The measurement method based on parallel controlling of interelectrode voltages was considered. It was referred to analogical research based on serial measurement method [3]. The errors of measuring apparatus were presented as sum of three basic components: random additive, systematic additive and systematic multiplicative. For quantitative comparison of particular errors influence on reconstruction errors the conversion factor was introduced. It was defined as square root of ratio of reconstruction variance errors. The results of investigations of conversion degree of instrumental errors in relation to errors of conductivity image obtained from relations (6) and (7) as well as using Mote Carlo method have been compared (Fig.1). The instrumental errors have bigger negative influence on reconstruction accuracy of elements conductivity in the internal area of considered object (lower numbers in figures). They are cause of results' retrogradation in this area. The influence of systematic additives and random errors is significantly bigger than systematic multiplicative. The derived relations can be applied for the requirement formulation in relation to accuracy requirements of measuring systems on the beginning of tomography system design process.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1552-1554
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
STEM-EDX and FIB-SEM Tomography of ALLVAC 718Plus Superalloy
Autorzy:
Kruk, A.
Cempura, G.
Lech, S.
Czyrska-Filemonowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/354670.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
TEM
SEM
STEM-EDX tomography
FIB-SEM tomography
Allvac 718Plus
Opis:
Allvac 718Plus (718Plus) is a high strength, corrosion resistant nickel- based superalloy used for application in power generation, aeronautics and aerospace industry. The 718Plus microstructure consists of a γ matrix with γ’-Ni3(Al,Ti) and some δ- Ni3Nb phases as well as lamellar particles (η-Ni3Ti, η*-Ni6AlNb or Ni6(Al,Ti)Nb) precipitated at the grain boundaries. The primary strengthening mechanism for this alloy is a precipitation hardening, therefore size and distribution of precipitates are critical for the performance of the alloy. The aim of this study was to characterize precipitates in the 718Plus superalloy using Scanning Transmission Electron Microscope combined with Energy Dispersive X-ray Spectroscopy (STEM-EDX) and Focused Ion Beam Scanning Electron Microscope (FIB-SEM). The STEM-EDX and FIB-SEM tomography techniques were used for 3D imaging and metrology of the precipitates. Transmission electron microscopy and EDX spectroscopy were used to reveal details of the 718Plus microstructure and allow determine chemical composition of the phases. The study showed that electron tomography techniques permit to obtain complementary information about microstructural features (precipitates size, shape and their 3D distribution) in the reconstructed volume with comparison to conventional particle analysis methods, e.g. quantitative TEM and SEM metallography.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 535-542
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PET and SPECT imaging as a solid guide to detect and discriminate atypical phenotypes of neurodegenerative disorders
Autorzy:
Ruffini, Livia
Zilioli, Alessandro
Cervati, Veronica
Lauretani, Fulvio
Misirocchi, Francesco
Maggio, Marcello
Migliari, Silvia
Graziani, Tiziano
Cidda, Carla
Baldari, Giorgio
Spallazzi, Marco
Scarlattei, Maura
Powiązania:
https://bibliotekanauki.pl/articles/40521373.pdf
Data publikacji:
2024-03-30
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
atypical phenotypes
neurodegenerative diseases
positron emission tomography
single photon emission computed tomography
Opis:
Introduction and aim. Atypical or mixed presentations of neurodegenerative disorders may postpone or confound the final diagnosis. Molecular imaging with positron emission tomography (PET) and single photon emission computed tomography (SPECT) radioligands provide target-specific information and may anticipate the diagnosis by “in vivo” detection of the neuropathological substrate, as Aβ deposition, nigrostriatal dopaminergic depletion or tau inclusions. This concise review will discuss the potential of PET and SPECT imaging as a solid guide to better characterize atypical phenotypes of neurodegeneration in the clinical routine, with the potential to drive personalized interventions, improve cohort uniformity for clinical trials, and serve as biomarkers for targeted molecular therapies. Material and methods. Literature search was performed focusing on the role of PET and SPECT imaging in assessing atypical phenotypes of neurodegeneration, using the electronic source of database PubMed/MEDLINE and the web-based search engines Google, Google Scholar. Analysis of the literature. New disease-modifying drugs may increase their effect with early initiation, which is especially important in working persons and younger subjects presenting atypical symptoms. In older individuals, the coexistence of neurodegeneration, age-related changes, cerebrovascular lesions, or depression makes challenging a definitive diagnosis. Quantitative tools able to measure tracer distribution increase the accuracy of molecular neuroimaging creating topographic maps that compare subject’s data with healthy controls databases. Conclusion. Atypical phenotypes may be associated with quantitative key-pattern allowing a more precise and early diagnosis of the neurodegenerative disorder. Finally, quantitative assessment of the pathological substrates allows us to track the disease process and measure treatment response.
Źródło:
European Journal of Clinical and Experimental Medicine; 2024, 22, 1; 201-221
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szybka metoda rozwiązania zagadnienia odwrotnego tomografii elektrycznej
Fast method of electrical tomogfaphy inverse problem solution
Autorzy:
Brydak, K.
Dorozhovets, M.
Powiązania:
https://bibliotekanauki.pl/articles/152574.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tomografia elektryczna
electrical tomography
Opis:
W pracy przedstawiono podstawowe problemy rekonstrukcji obrazu rozkładu przestrzennego parametrów elektrycznych w tomografii elektrycznej. Zaproponowano szybszą i bardziesz precyzyjną metodę obliczania macierzy Jacobiego bez błędu metody. Zaproponowano metodę adaptacji parametru regularyzacji w procesie rozwiązania zagadnienia odwrotnego, dzięki czemu znacznie poprawia się zbieżność algorytmu rekonstrukcji. Zaprezentowano wyniki eksperymentów numerycznych dla kilku wybranych modeli rozkładu przestrzennego parametrów.
This article investigates basic problems concerning image reconstruction of electrical parameters space distribution in electrical tomography. The fast and precise metod (without methodical error) or the Jakobian matrix calculation is proposed. Moreover, the algorithm of regularized parameter adaptation in inverse problem solution is proposed. As a result of this, time of the image reconstruction is significant reduced and image becomes more precise. On top of thatm the article presents the results of some numerical experiments for the selected object spatial distribution parameter models.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 425-428
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi phase flow measurements with the application of ECT/ERT DECART multimodality tomograph
Pomiary przepływów wielofazowych z wykorzystaniem tomografu multimodalnego DECART
Autorzy:
Nowakowski, J.
Banasiak, R.
Wajman, R.
Sankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/408319.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
tomography
electrical capacitance tomography
gamma ray
tomografia
elektryczna tomografia pojemnościowa
promieniowanie gamma
Opis:
The multi-phase flow measurements are very important tasks in many areas of industrial processes applications. One of them is undersea exploration of oil in the petroleum industry. The submitted paper presents application of DECART tomograph designed and built in Lodz University of Technology - together with combined measurements of signals acquired from gamma ray measurement system. Use of all measuring modalities allowed for performing measurements of a flow composed of sea water, oil and gas. The paper presents theoretical principles applied to design multimodality tomograph and results of experiments performed in the University of Bergen. Measurement confirmed that multi-modality approach allows giving fast and reliable on-line results of measurements of composition of multi-phase flow. Applied algorithms allowed to speed up on-line measurements and presenting results in a form required in industrial applications. The derived conclusions can be used as guidelines for preparation of industrial applicable construction of tomograph.
Pomiary przepływów wielofazowych są szeroko wykorzystywane w wielu procesach przemysłowych. Jednym z nich jest przemysł petrochemiczny, w szczególności dziedzina eksploatacji podwodnych złóż ropy naftowej. W artykule zostało przedstawione zastosowanie tomografu DECART - zaprojektowanego i zbudowanego w Instytucie Informatyki Stosowanej Politechniki Łódzkiej. Pomiary z tomografu zostały powiązane z sygnałami uzyskanymi z systemu pomiaru promieniowania gamma. Wykorzystanie danych uzyskanych z różnych rodzajów czujników umożliwiło pomiar przepływu mieszaniny składającej się z wody morskiej, ropy naftowej i gazu. W pracy przedstawiono podstawy teoretyczne, które stanowiły punkt wyjścia do wykorzystania tomografu multimodalnego jak i wyniki eksperymentów przeprowadzonych na Uniwersytecie w Bergen. Pomiary potwierdziły, że podejście multimodalne umożliwia szybki i niezawodny pomiar udziału faz w przepływie wielofazowym. Zastosowane algorytmy pozwalają na przyspieszenie pomiarów on-line i przedstawienie wyników w formie wymaganej w zastosowaniach przemysłowych. Wnioski z badań mogą być wykorzystane jako wskazówki dla konstrukcji tomografu do praktycznych zastosowań przemysłowych.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 46-49
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of combustion processes in industrial burners using electrical capacitance tomography
Autorzy:
Gut, Z.
Wolanski, P.
Oleszczak, P.
Powiązania:
https://bibliotekanauki.pl/articles/245557.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
combustion
industrial burner
diagnostic
tomography
Opis:
The development of diagnostic methods suitable for the monitoring of practical flames is an important objective, which is receiving a growing attention and significant research efforts. This is motivated by the need to achieve a more precise description of the process and, ultimately, implement efficient and reliable control and optimization methods as a key step towards the development of more efficient, flexible, reliable and clean combustion systems. Many interesting attempts have been proposed, involving very different approaches in the use of various instruments and sensors. One of parameter difficult to control is distribution of reaction zone. Presently, such system which allows monitoring combustion process of industrial burners does not exist. Measurements of temperature or control of exist flame by using ionization probe provide only partial information about performance of combustion process. For that reason, new diagnostic methods should be developed. Many and interesting attempts have been proposed but one of interesting solution will be development of combustion process diagnostic methods by means of the Electrical Capacitance Tomography (ECT). Obtained results show that it will be a very good tool for research proposes, especially in development of a new combustion chamber operated at very high pressure, where installation of optical windows is very difficult and many time not possible.
Źródło:
Journal of KONES; 2011, 18, 3; 117-121
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic tomography of a turbulent water jet
Autorzy:
Gavrilenko, V.
Didenkulov, I.
Kustov, L.
Martyanov, A.
Nechayeva, M.
Vyugin, P.
Pronchatov-Rubtsov, N.
Powiązania:
https://bibliotekanauki.pl/articles/331748.pdf
Data publikacji:
2003
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
acoustic tomography
turbulent water
hydroacoustics
Opis:
Measurement of parameters of flowing liquid is one of problems, which have many applications. in the present paper we describe linear and nonlinear acoustic tomography methods for reconstruction of parameters of a turbulent water jet with gas bubbles. Experiments on both techniques are described. in the linear acoustic method it was measured fluctuations of acoustic signal passed through the jet. In the nonlinear acoustic technique it was measured spectra of combination scattering signals in the jet. Experiments were done in a water tank with a submerged water jet. The results of the work demonstrate the possibility of the tomography of flowing bubble liquids.
Źródło:
Hydroacoustics; 2003, 6; 91-100
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fibromuscular dysplasia – a case description
Autorzy:
Leksa, Natalia
Seweryn, Bartosz
Uberman-Kluz, Dominika
Galiniak, Sabina
Kawalec, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/454927.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
fibromuscular dysplasia
arteries
computed tomography
Opis:
Introduction. Fibromuscular dysplasia is an idiopathic, non-inflammatory and non-atherosclerotic disease that affects the walls of arteries (mostly renal and carotid arteries). Histological classification distinguishes three main types of the disease, depending on the structural changes occurring in one of the three layers of arterial vessel walls. Objective. We present here a case of fibromuscular dysplasia affecting the internal carotid arteries. Case description. This article describes the case of a 52-year-old female patient with hypertension, hyperlipidemia, and a cardiac pacemaker in whom computed tomography angiography revealed a narrowing of the internal carotid arteries without atherosclerotic symptoms. We describe the diagnostic methods and various types of treatment that the patient suffering from fibromuscular dysplasia was subjected to. Conclusions. Due to a low detection rate of fibromuscular dysplasia, if the disease is suspected, all available diagnostic methods should be employed. Taking into account the unknown etiology of the disease, it is not possible to use a preventive therapy, or a therapy focused on stalling the progression of the disease
Źródło:
European Journal of Clinical and Experimental Medicine; 2018, 1; 63-67
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of fractional calculus for modelling of two-phase gas/liquid flow system
Zastosowanie rachunku różniczkowego niecałkowitego rzędu do modelowania przepływów dwufazowych gaz/ciecz
Autorzy:
Nowakowski, J.
Ostalczyk, P.
Sankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/408891.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
tomography
electrical capacitance tomography
fractional calculus
tomografia
tomografia elektryczna pojemnościowa
rachunek różniczkowy niecałkowitego rzędu
Opis:
In recent years the use of fractional calculus in control system identification is becoming popular and it has found new applications. The paper presents application of fractional calculus for modelling of two-phase gas/liquid flows in a test rig. The installation consists of three horizontal and vertical measuring segments with different diameters, which allow to investigate flows in a wide range of parameters. Flow components supply is measured/controlled by NI PXI system and a set of flow meters/controllers. The paper presents model of the two-phase flow in the above described installation, which leads to precise and accurate flow mathematical model. The main goal of the flow model is to describe steady flow parameters, especially the flow fractions, or type of the flow. The model describes flows more accurately, that classical second order system model.
W ostatnich latach wykorzystanie rachunku różniczkowego niecałkowitego rzędu staje się coraz bardziej popularne i znajduje nowe obszary zastosowań. W pracy przedstawiono zastosowanie powyższego rachunku różniczkowego do modelowania przepływów dwufazowych gaz / ciecz. Instalacja badawcza składa się z trzech poziomych i pionowych odcinków pomiarowych o różnych średnicach, które umożliwiają badanie przepływu w szerokim zakresie parametrów. Przepływ komponentów mieszaniny jest mierzony / sterowany przez system NI PXI oraz zestaw przepływomierzy i sterowników. W artykule przedstawiono modelowanie przepływu dwufazowego w wyżej opisanej instalacji, które prowadzi do określenia precyzyjnego modelu matematycznego przepływu. Opracowany model opisuje przepływy dwufazowe dokładniej w porównaniu z klasycznym model opisanym równaniami różniczkowymi drugiego rzędu.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 42-45
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of electrical capacitance tomograph design in the nuclear and medical electronics division
Rozwój konstrukcji elektrycznego tomografu pojemnościowego w zakładzie elektroniki jądrowej i medycznej
Autorzy:
Kryszyn, J.
Smolik, W.
Olszewski, T.
Szabatin, R.
Powiązania:
https://bibliotekanauki.pl/articles/408376.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
electrical capacitance tomography
elektryczna tomografia pojemnościowa
Opis:
Electrical Capacitance Tomography is a technique which allows to visualize a spatial distribution of electric permittivity in an examined volume. ECT allows to achieve hundreds of frames per second which is suitable for the industrial application, e.g. monitoring of multiphase flows or material mixing. Construction of such ECT system which enables precise data acquisition with sufficient speed is a challenge. In the Division of Nuclear and Medical Electronics ECT systems which have found applications in many research facilities in Poland and all over the world have been constructed for over 15 years. In this article a multichannel ET3 tomograph and its successor,EVT4, are presented. EVT4 will allow to obtain more than 10 thousand frames per second. This will allow to make progress in studies of dynamic processes and 3D visualization.
Elektryczna tomografia pojemnościowa pozwala na obrazowanie przestrzennego rozkładu przenikalności elektrycznej w badanej objętości. Technika ta pozwala na uzyskanie setek obrazów na sekundę, dzięki czemu istnieje możliwość wykorzystania jej w przemyśle, na przykład do monitorowania procesów dynamicznych, takich jak przepływy wielofazowe lub mieszanie materiałów. Skonstruowanie systemu tomograficznego pozwalającego na bardzo szybką akwizycję obrazów o dobrej jakości jest jednak dużym wyzwaniem. W Zakładzie Elektroniki Jądrowej i Medycznej Politechniki Warszawskiej od lat powstają konstrukcje tomografów pojemnościowych, które znajdowały zastosowanie w placówkach naukowych w Polsce i na świecie. W tym artykule prezentowany jest wielokanałowy tomograf ET3 oraz jego następca, EVT4, który pozwoli na uzyskiwanie 10 tysięcy obrazów na sekundę. Pozwoli to na dokładniejsze badanie procesów dynamicznych oraz wizualizację trójwymiarową.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 111-114
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tomografia komputerowa w neuroradiologii
Autorzy:
Witulski, M.
Bobek-Billewicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/261405.pdf
Data publikacji:
2008
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
tomografia
nauroradiologia
nauronawigacja
tomography
nauroradiology
neuronavigation
Opis:
Obserwując historię tomografii komputerowej, można bez wahania stwierdzić, że to neuroradiologia była stymulatorem powstania i rozwoju TK. Zarówno pierwszy prototyp tomografii, jak i pierwsze komercyjnie dostępne skanery byty przeznaczone do badań głowy. Dopiero w okresie późniejszym rozszerzono zakres możliwości aplikacyjnych tomografów na badania całego ciała.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2008, 14, 3; 249-250
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Passive Seismic Tomography at Rudna Copper Ore Mine
Autorzy:
Dębski, W.
Cianciara, A.
Koziarz, E.
Powiązania:
https://bibliotekanauki.pl/articles/164020.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwa Geofizyczne
Tematy:
inverse methods
induced seismicity
seismic tomography
Opis:
Seismic tomography is a technique widely used to image the Earth’s interior at various scales, from the very local subsurface to the whole Earth’s interior. Successful tomographic applications in seismology have opened the question of whether, or not, the method can also be helpful in assessing the safety of mining operations. Long-time efforts and accumulated evidence with tomography imaging carried out at the Rudna copper mine clearly indicate that this is really the case. Repeating imaging of velocity distributions reveals that the observed temporal changes provide information that is useful for improving the safety of mining processes. In this paper, we describe our experience of performing seismic passive velocity tomography at the Rudna copper ore mine in the south-western part of Poland. We consider only the last 10 years, when the geophysical unit of Rudna copper mine began using an advanced modern tomography software developed originally for this mine.
Źródło:
Przegląd Geofizyczny; 2018, 4; 339-352
0033-2135
Pojawia się w:
Przegląd Geofizyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the accuracy of preoperative imaging methods in the diagnosis of hepatic single-chamber echinococcosis
Autorzy:
Hołody-Zaręba, Joanna
Zaręba, Konrad Piotr
Kędra, Bogusław
Powiązania:
https://bibliotekanauki.pl/articles/1396512.pdf
Data publikacji:
2013-12-01
Wydawca:
Index Copernicus International
Tematy:
single-chamber echinococcosis
ultrasonography
computed tomography
Opis:
Echinococcosis is an infectious disease, caused by larval stages of cestode species of the genus Echinococcus. The course of the disease is determined on the basis of the location and larval size. In 80-95% of cases echinococcosis is located in the liver and lungs, rarely in the brain. Symptoms are usually uncharacteristic for an uncomplicated disease. The diagnosis of echinococcosis is based on imaging and immunodiagnostic tests. The aim of the study was to assess the accuracy of preoperative imaging methods in the diagnosis of hepatic single- chamber echinococcosis. Material and methods. Amongst the 110 patients with hepatic cysts diagnosed during the period between 2000 and 2009, a group of 30 subjects with suspicion of single-chamber echinococcosis (ultrasound and CT) was isolated. The imaging methods visualized structures typical for hydatid cysts: the mother cyst with satellite cysts called “ honeycomb appearance”, cysts with calcified walls and compartments, and endocyst separation called “water lily-sign”. The study group comprised 22 female and 8 male patients with an average age of 52±16.2 years. The histopathological examination of the excised cyst verified the diagnosis. Results. Single-chamber echinococcosis was finally recognized in 19 cases, while in the 11 remaining cases the parasitic disease was excluded. The sensitivity of imaging methods was estimated at 73.7%, specificity - 88.9%, negative predictive value - 61.5%, positive predictive value - 93.3%, Youden`s factor - 0.626, and Φ index - 0.586. Conclusions. In conclusion, the presence of an unilocular cyst with an uniform anechoic content can be a simple cyst or single-chamber echinococcus cyst. The typical, characteristic image of a hydatid cyst, such as the “water lily-sign” is rarely observed during imaging examinations. It has also been shown that cystic calcification, observed during ultrasonography and computed tomography was evidence of the parasitic character of the lesion.
Źródło:
Polish Journal of Surgery; 2013, 85, 12; 693-698
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern radiation techniques for treatment of head and neck cancers
Autorzy:
Kiprian, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/1401820.pdf
Data publikacji:
2015
Wydawca:
Index Copernicus International
Tematy:
positron emission tomography
radiotherapy
throat
apoptosis
Opis:
Alongside surgery, radiation therapy remains the mainstay of treatment for head and neck cancers.  Because the head and neck contain a number of critically important structures, it is crucial to try to curtail the adverse effects of radiation therapy by increasing its precision. Such precise radiation techniques include the three-dimensional conformal as well as highly conformal radiotherapy. The latter includes, for instance, intensity modulated radiation therapy (IMRT), stereotactic radiation, and proton-beam therapy. All of the above-mentioned techniques are available in Poland and give the opportunity of a more aggressive treatment that lead to improved outcomes, curtailment of adverse effects, and by that, a better quality of life.
Źródło:
Polski Przegląd Otorynolaryngologiczny; 2015, 4, 4; 1-10
2084-5308
2300-7338
Pojawia się w:
Polski Przegląd Otorynolaryngologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasound Transmission Tomography Imaging of Structure of Breast Elastography Phantom Compared to US, CT and MRI
Autorzy:
Opieliński, K. J.
Pruchnicki, P.
Gudra, T.
Podgórski, P.
Kraśnicki, T.
Kurcz, J.
Sąsiadek, M.
Powiązania:
https://bibliotekanauki.pl/articles/176996.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound transmission tomography
UTT
ultrasonography
US
computed tomography
magnetic resonance
MR
mammography
breast biopsy phantom
Opis:
The paper presents an analysis of the results of ultrasound transmission tomography (UTT) imaging of the internal structure of a breast elastography phantom used for biopsy training, and compares them with the results of CT, MRI and, conventional US imaging; the results of the phantom examination were the basis for the analysis of UTT method resolution. The obtained UTT, CT and MRI images of the CIRS Model 059 breast phantom structure show comparable (in the context of size and location) heterogeneities inside it. The UTT image of distribution of the ultrasound velocity clearly demonstrates continuous changes of density. The UTT image of derivative of attenuation coefficient in relation to frequency is better for visualising sharp edges, and the UTT image of the distribution of attenuation coefficient visualises continuous and stepped changes in an indirect way. The inclusions visualized by CT have sharply delineated edges but are hardly distinguishable from the phantom gel background even with increased image contrast. MRI images of the studied phantom relatively clearly show inclusions in the structure. Ultrasonography images do not show any diversification of the structure of the phantom. The obtained examination results indicate that, if the scanning process is accelerated, ultrasound transmission tomography method can be successfully used to detect and diagnose early breast malignant lesions. Ultrasonic transmission tomography imaging can be applied in medicine for diagnostic examination of women’s breasts and similarly for X-ray computed tomography, while eliminating the need to expose patients to the harmful ionising radiation.
Źródło:
Archives of Acoustics; 2013, 38, 3; 321-334
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody pozyskiwania danych pierwotnych przy użyciu komputerowych systemów tomograficznych
Methods of acquisition raw data with use computer tomography system
Autorzy:
Budzik, G.
Turek, P.
Powiązania:
https://bibliotekanauki.pl/articles/136016.pdf
Data publikacji:
2016
Wydawca:
Wyższa Szkoła Techniczno-Ekonomiczna w Szczecinie
Tematy:
tomografia komputerowa
system jednorzędowy
system wielorzędowy
tryb spiralny
tryb osiowy
computer tomography
SDCT
single detector computer tomography
MDCT
multi detector computer tomography
helical scanning
axial scanning
Opis:
Wstęp i cel: Od momentu wręczenia Nagrody Nobla dla Godfreya Hounsfielda i Allana Cormacka pomiar przy użyciu systemów tomograficznych ulegał ciągłym przeobrażeniom. Celem przedstawionej pracy jest wykazanie różnic w funkcjonowaniu trybu osiowego oraz spiralnego w tomograficznych systemach jednorzędowych oraz wielorzędowych Materiał i metody: W pracy przedstawiono metody pozyskiwania danych pierwotnych. Wyszczególniono i opisano tryb osiowy i spiralny. Scharakteryzowano systemy jednorzędowe oraz wielorzędowe. Wyniki: Przy zastosowaniu metody osiowej uzyskuje się wyższej jakości obrazy niż podczas wykorzystywania metody spiralnej Główna wada tej metody, dotyczy powstawania przerw czasowych pomiędzy kolejnymi pomiarami, a tym samym zwiększa ryzyko wystąpienia artefaktów związanych z ruchem pacjenta. Spiralna tomografia znacznie usprawniła pomiar. Skrócenie czasu skanowania poprzez wyeliminowanie czasu przestojów stołu, poprawiło rozdzielczość przestrzenną i kontrastową uzyskany obrazów tomograficznych. Główne zmiany dotyczyły także lampy rentgenowskiej, której obrót od tej chwili był ciągły, a moc wiązki promieniowania pozostawała stała. Wniosek: Nowoczesne systemy tomograficzne, oferują dwa podstawowe tryby skanowania osiowy oraz spiralny. Aktualnie tryb spiralny jest najczęściej stosowaną metodą pozyskiwania danych pierwotnych. Pozostają jednak sytuacje, w których najlepiej sprawdza się tryb osiowy. Rozwój technologiczny pozwolił na wdrożenie oraz ulepszanie trybu spiralnego w systemach wielorzędowych
Introduction and aim: Since its introduction by Godfrey Hounsfield and Allan Cormack, CT has continued to evolve. The aim of this work is to demonstrate the differences in the functioning of axis and spiral mode in CT systems with single-and multi-row Material and methods: The article presents the methods of acquisition raw data. Especially present axial and helical methods. Characterized single raw and multi raw CT systems. Results: Axial method results in the highest image quality, superior to that of helical method. Main disadvantages this method is that the cumulative effect of pauses between each data acquisition and motion artefact. Helical CT has revolutionized clinical imaging. Increasing the scan speed results in improved image resolution. Main changes also concern the x-ray tube (continually rotating and constant x-ray output). Conclusion: Modern scanners offer two basic option of scanning: axial and helical. Although helical scan methods are now the most widely used, there remain specific situation in which axial methods are preferred. Since its inception, helical technology has been continuously refined with new and improved MDCT systems.
Źródło:
Problemy Nauk Stosowanych; 2016, 4; 5-12
2300-6110
Pojawia się w:
Problemy Nauk Stosowanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Główne właściwości spiralnej tomografii komputerowej
Main features of the spiral computed tomography systems
Autorzy:
Budzik, G.
Turek, P.
Powiązania:
https://bibliotekanauki.pl/articles/136048.pdf
Data publikacji:
2016
Wydawca:
Wyższa Szkoła Techniczno-Ekonomiczna w Szczecinie
Tematy:
tomografia komputerowa
system jednorzędowy
system wielorzędowy
tryb spiralny
tryb osiowy
computer tomography
SDCT
single detector computer tomography
MDCT
multi detector computer tomography
helical scanning
axial scanning
Opis:
Wstęp i cel: Największy rozwój technologiczny systemów tomograficznych, nastąpił w latach 90-tych. Związany był on z wprowadzeniem pierścieni ślizgowych, dzięki którym możliwe było wykonanie pomiaru w trybie ciągłym wzdłuż toru jakim była spirala. Dzięki przedstawionej pracy będzie można zrozumieć dlaczego tryb spiralny stał się rewolucyjną metodą pomiarową, która obecnie powszechnie jest stosowana w tomograficznych systemach pomiarowych jednorzędowych oraz wielorzędowych. Materiał i metody: W pracy przedstawiono główne cechy oraz możliwości spiralnej tomografii komputerowej. Wyniki: Dzięki wprowadzeniu nowego trybu pomiarowego, uległa zmianie konstrukcja tomografu: gantra posiadała wbudowane pierścienie ślizgowe, lampa rentgenowska wyposażona została w dodatkowy system chłodzenia, a detektory charakteryzowały się większą sprawnością. Dodatkowo zastosowano nowe oprogramowanie do przetwarzania danych pomiarowych oraz sterowania ruchem stołu. Wprowadzone zostały metody interpolacji danych. Wniosek: Dzięki zastosowaniu spiralnej tomografii, skrócono czas pomiaru, zwiększono rozdzielczość uzyskanych danych oraz uzyskano możliwość wizualizacji otrzymanych wyników do modelu trójwymiarowego.
Introduction and aim: The greatest technological development of the tomography systems occurred in the 90’s. It was related with use slip ring technology, whereby it makes possible a data-gathering using a continuous helical pattern movements. The paper presents information about spiral mode, and explain why this technology has become a revolutionary method of measurements use in single and multi detector systems. Material and methods: The paper presents the main features and possibilities of spiral computed tomography. Results: With the introduction of the new measurement mode, changed the design CT: gantra have a slip rings design, X-ray tube is equipped with a cooling system, and the detectors were more efficient. In addition, it also included new data processing and control table movements software. They were introduced new methods of data interpolation. Conclusion: Using the spiral CT, increasing the scan speed results and improved the resolution of the data. In addition superior, multiplanar and three dimensional reformation capabilities.
Źródło:
Problemy Nauk Stosowanych; 2016, 5; 125-132
2300-6110
Pojawia się w:
Problemy Nauk Stosowanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multimodal Ultrasonic Imaging for Breast Cancer Detection
Autorzy:
Camacho, J.
Medina, L.
Cruza, J. F.
Moreno, J. M.
Fritsch, C.
Powiązania:
https://bibliotekanauki.pl/articles/176695.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound imaging
ultrasound tomography
breast cancer
Opis:
Ultrasound is used for breast cancer detection as a technique complementary to mammography, the standard screening method. Current practice is based on reflectivity images obtained with conventional instruments by an operator who positions the ultrasonic transducer by hand over the patient’s body. It is a non-ionizing radiation, pain-free and not expensive technique that provides a higher contrast than mammography to discriminate among fluid-filled cysts and solid masses, especially for dense breast tissue. However, results are quite dependent on the operator’s skills, images are difficult to reproduce, and state-of-the-art instruments have a limited resolution and contrast to show micro-calcifications and to discriminate between lesions and the surrounding tissue. In spite of their advantages, these factors have precluded the use of ultrasound for screening. This work approaches the ultrasound-based early detection of breast cancer with a different concept. A ring array with many elements to cover 360. around a hanging breast allows obtaining repeatable and operator-independent coronal slice images. Such an arrangement is well suited for multi-modal imaging that includes reflectivity, compounded, tomography, and phase coherence images for increased specificity in breast cancer detection. Preliminary work carried out with a mechanical emulation of the ring array and a standard breast phantom shows a high resolution and contrast, with an artifact-free capability provided by phase coherence processing.
Źródło:
Archives of Acoustics; 2012, 37, 3; 253-260
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eddy Current Tomography for Nondestructive Testing
Autorzy:
Salach, J.
Powiązania:
https://bibliotekanauki.pl/articles/384233.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
eddy current tomography
NDT
signal processing
Opis:
The paper presents an eddy current tomography setup with high spatial resolution and high accuracy of measurements of signal on detection coil. In proposed solution both amplitude as well as phase shift are measured, which gives the possibility of calculation of spatial distribution of both permeability and resistivity of tested element. As a result, presented setup creates possibility of effective detection of discontinuities in cylindrical elements, which opens new possibilities for industrial applications of eddy current tomography.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2014, 8, 4; 11-14
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using electrical capacitance tomography system for determination of liquids in rocket and satellite tanks
Wykorzystanie systemu pojemnościowej tomografii komputerowej do określania poziomu płynów w zbiornikach rakiet i satelitów
Autorzy:
Gut, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/36411211.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
tomography
satellite
tank
tomografia
satelity
zbiorniki
Opis:
One of important problems in aerospace engineering is to determine the amount of fluid in the tank in a microgravity environment. There are several methods for doing it, however, there are no proven methods to quickly gauge the amount of propellant in a tank in low gravity conditions. New and more accurate methods of such a measurement are being continually searched for. One of interesting solutions is using Electrical Capacitance Tomography (ECT) for this purpose. The article presents both numerical analysis and experimental test results using a spherical tank. The main purpose of the simulation was to determine the effect of the number of electrodes and noise signal level on the quality of reconstruction images. In numerical simulations, different models of dielectric permittivity distribution have been reconstructed. On the basis of numerical simulations, a 24-electrode sensor was designed and made. In experimental tests, different distribution of medium inside the spherical tank was investigated. The results show that the method can directly measure the mass of fuel in the tank, as well as it allows for a visualization of fuel distribution, independent of the tank position in space, and the liquid-propellant system will be used.
Istotnym problemem w inżynierii kosmicznej jest sposób określenia ilości paliwa w zbiorniku w środowisku mikrograwitacji. Istnieje kilka metod określania poziomu cieczy w zbiorniku, jednakże nie ma sprawdzonych metod szybkiego pomiaru ilości paliwa w zbiorniku, gdy znajduje się on w stanie niskiej grawitacji. Trwają poszukiwania nowych i dokładniejszych metod pomiaru. Jednym z ciekawszych rozwiązań jest zastosowanie Pojemnościowej Tomografii Komputerowej do określania poziomu paliwa lub utleniacza w zbiornikach rakiet i satelitów. Otrzymane wyniki, które przeprowadzono z wykorzystaniem metod numerycznych oraz w warunkach grawitacji pokazują, że metoda może bezpośrednio mierzyć masę paliwa w zbiorniku, a także umożliwić wizualizację rozkładu paliwa, niezależnie od położenia zbiornika w przestrzeni i zastosowanego układu zasilania.
Źródło:
Transactions on Aerospace Research; 2020, 1 (258); 18-33
0509-6669
2545-2835
Pojawia się w:
Transactions on Aerospace Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel hybrid algorithm using convolutional autoencoder with SVM for electrical impedance tomography and ultrasound computed tomography
Nowy algorytm hybrydowy wykorzystujący autoenkoder konwolucyjny z SVM dla elektrycznej tomografii impedancyjnej i tomografii ultradźwiękowej
Autorzy:
Maciura, Łukasz
Wójcik, Dariusz
Rymarczyk, Tomasz
Król, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/27315418.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
convolutional autoencoder
SVM
electrical impedance tomography
ultrasound transmission tomography
autoencoder konwolucyjny
elektryczna tomografia impedancyjna
ultradźwiękowa tomografia transmisyjna
Opis:
This paper presents a new hybrid algorithm using multiple support vector machines models with a convolutional autoencoder forelectrical impedance tomography, and ultrasound computed tomography image reconstruction. The ultimate hybrid solution uses multiple SVM models to convert input measurements to individual autoencoder codes representing a given scene then the decoder part of the autoencoder can reconstruct the scene.
Artykuł przedstawia nowy hybrydowy algorytm który używa modeli maszyn wektorów nośnych wraz z autoenkoderem konwolucyjnym do rekonstrukcji obrazu z elektrycznej tomografii impedancyjnej oraz ultrasonograficznej tomografii transmisyjnej. Ostateczne rozwiązanie hybrydowe używa wielu modeli SVM do konwersji pomiarów wejściowych do pojedynczych kodów autoenkodera reprezentujących daną scenę a wtedy dekoder wyciętyz autoenkodera może zrekonstruować daną scenę.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2023, 13, 2; 4--9
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary dwuenergetycznej tomografii (Dual Energy CT) w celu badania skał
Calibration of dual energy CT scans for rock core examination
Autorzy:
Dohnalik, Marek
Kaczmarczyk, Jan
Powiązania:
https://bibliotekanauki.pl/articles/1834984.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
tomografia komputerowa
Dual Energy CT
DECT
dwuenergetyczna tomografia
computed tomography
dual energy CT
dual energy computed tomography
Opis:
: Jedno z pierwszych zastosowań rentgenowskiej tomografii komputerowej w geologii miało miejsce w 1974 roku. Tomografia rentgenowska (CT) umożliwia nieinwazyjne obrazowanie badanych przedmiotów. Wynikiem pomiaru tomograficznego jest przestrzenny obraz, przedstawiający zmiany absorpcji promieniowania rentgenowskiego. Powstaje on poprzez wyliczenie, podczas procesu rekonstrukcji, wartości absorpcji dla każdego punktu badanego przedmiotu. Istotną zaletą tomografów komputerowych jest możliwość przebadania dużych obiektów (metrowych odcinków rdzenia) w bardzo krótkim czasie. Ich wadą jest natomiast względnie niska rozdzielczość pomiaru. Każdy woksel na obrazie tomograficznym ma przypisaną konkretną wartość zaczernienia proporcjonalną do liniowego współczynnika tłumienia, zależną od gęstości elektronowej i efektywnej liczby atomowej, uśrednionych w obrazowanej przestrzeni (zakres uśredniania określa rozdzielczość obrazu tomograficznego). Dysponując dwoma obrazami, zarejestrowanymi przy dwóch różnych energiach pomiaru, można podjąć próbę rozdziału obrazu na dwie składowe: pierwszą – zależną od gęstości elektronowej i drugą – zależną od efektywnej liczby atomowej. Celem opisanych prac jest pokazanie możliwości wykorzystania dwuenergetycznej tomografii komputerowej (DECT) do charakterystyki litologiczno-gęstościowej rdzeni wiertniczych. Aby wykorzystać obrazy tomograficzne do otrzymania wymienionych wielkości fizykochemicznych konieczna jest standaryzacja obrazów. W pracy przedstawiono proces wyznaczania współczynników kalibracyjnych, które są niezbędne do przeliczania wartości współczynników absorpcji, będących bezpośrednim wynikiem rekonstrukcji pomiaru tomograficznego na wartości gęstości elektronowej oraz efektywnej liczby atomowej Z. W artykule zaprezentowano proces kalibracji z wykorzystaniem wzorcowych minerałów. Wyliczone z analizy obrazów wartości próbek wzorcowych, porównano z wartościami wyznaczonymi metodami laboratoryjnymi. Przykład zastosowania wyników przedstawiono na przebadanym fragmencie obrazu rdzenia piaskowca, zawierającego szczelinę wypełniona kalcytem.
One of the first applications of X-ray computed tomography in geology took place in 1974. X-ray tomography (CT) allows non-invasive imaging of the examined objects. The result of a tomographic measurement is a spatial image, showing the changes in X-ray absorption value for each point of the examined object, which are a result of calculations during the reconstruction process. An important advantage of computer tomographs is the ability to test large objects (meter sections of the core) in a very short time, while the disadvantage is the relatively low resolution of the measurement. Each voxel in the tomographic image has a specific grey value, proportional to the linear attenuation coefficient, depending on the electron density and the effective atomic number averaged in the imaged space (the averaging range is determined by the resolution of the tomographic image). Two tomographic images registered at two different energies, allows the deconvolution of the images into two components: the first – dependent on the electron density and the second – dependent on the effective atomic number. The aim of this study is to show the possibility of using dual energy computed tomography (DECT) to litho-density characterization of rock cores. In order to use tomographic images to obtain the above-mentioned physicochemical values, it is necessary to standardize CT images. The paper presents the process of determining calibration coefficients, which are necessary to convert the values of absorption coefficients, which are a direct result of CT reconstruction, into density values and effective Z atomic number. The article presents the calibration process with the use of reference rock fragments. The values of the standard samples computed from the analysis of images were compared with the values determined by laboratory methods. An example of the application of results is presented on the examined part of the image of the sandstone core, containing a calcite-filled fracture.
Źródło:
Nafta-Gaz; 2019, 75, 2; 83-88
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Concentration of some amino acids in blood plasma and study results of lumbosacral bone system computer tomography
Autorzy:
Wójcik, G.
Sokołowska, B.
Borzecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/2052367.pdf
Data publikacji:
2015
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
amino acids
chromatography
computed tomography
lumbar spine
Opis:
Introduction and objective: Back pain are the most common ailment within the human locomotor system. Because of their prevalence, they were classified as diseases of civilization. The aim of the study was to attempt to assess the concentration of selected amino acids in plasma and correlating the results of laboratory tests with the occurrence of backaches. Material and method: The study group included 188 patients presenting for CT scan administering as the cause of their symptoms low back pains. All of these patients gave the blood samples from which the concentration of free amino acids was estimated by ion exchange chromatography using an automated amino acid analyzer AAA 400 from INGOS Praha. The control group consisted of patients who underwent testing using computed tomography and there were no primary or secondary changes associated with degeneration in the lumbar spine. Results: Patients on the basis of research carried out by computed tomography were divided into five groups according to disease entity. Analyzing the average concentration of essential amino acids in the blood plasma of patients of each group, it was found that it is higher in the case of lysine for each considered disease entity. The average concentration of methionine in all disease entities does not deviate from the average values in the control group. Analysis of the average concentration of selected essential amino acids revealed that in the case presented disorders underwent their level of variation. Average concentrations of selected amino acids have proven to be very similar in both groups. Slightly higher values proved to be in the control group for proline and lysine. Conclusions: The concentration of amino acids varies with the severity of degenerative changes in the connections as well as in interbody joints. The highest increase in the concentrations of all tested amino acids are present in root bands. Decrease in the concentrations of all tested amino acids appears in cancer.
Źródło:
Health Problems of Civilization; 2015, 09, 3; 5-11
2353-6942
2354-0265
Pojawia się w:
Health Problems of Civilization
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies