Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tomographic" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Tomographic system based on Plasma Focus X-rays
Autorzy:
Venere, M.
Moreno, C. H.
Clausse, A.
Barbuzza, R.
Del Fresno, M.
Powiązania:
https://bibliotekanauki.pl/articles/147461.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
defectoscopy
image processing
plasma focus applications
tomographic reconstruction
X-rays
Opis:
A system oriented to develop an image processing system, which takes advantage of radiation flashes from a plasma focus, by optimizing the emission-detection-reconstruction procedure, is presented. A computer technique for 3D reconstructions was combined with radiographic images of objects X-rayed with a compact plasma focus. The technique is able to automatically determine the position of the rotation axis, reconstruct the 3D-attenuation map, and display inner cuts. The system was demonstrated in introspective tomographic imaging of a stainless steel BNC elbow.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 93-94
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An adaptive stochastic optimization method for medical registration problem
Autorzy:
Król, Z.
Powiązania:
https://bibliotekanauki.pl/articles/333559.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
registration
matching
optimization
simulated annealing
similarity measure
non-deterministic methods
cooling schedule
tomographic data
rejestracja
optymalizacja
wyżarzanie
miara podobieństwa
metody niedeterministyczne
chłodzenie
dane tomograficzne
Opis:
This paper presents a methodology that addresses important issues concerned with the optimization of the misregistration measures in the volumetric medical data registration problem. Our registration framework uses robust simulated annealing method to handle multiple local minima of the cost function. Our efforts have been centred on obtaining a reliable, efficient and generally applicable method to solve such optimization problems. This has been accomplished through developing an adaptive cooling schedule for the simulated annealing method. The proposed method is very reliable for the estimation of the global minimum in the optimization of objective functions with highly differentiated search space landscapes. We present the detailed description of the method as well as discussion of its advantages and disadvantages.
Źródło:
Journal of Medical Informatics & Technologies; 2004, 7; MIP79-88
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interpolation-based reconstruction methods for tomographic imaging in 3D positron emission tomography
Autorzy:
Li, Y.
Kummert, A.
Boschen, F.
Herzog, H.
Powiązania:
https://bibliotekanauki.pl/articles/908045.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
rekonstrukcja tomograficzna
interpolacja dwuwymiarowa
twierdzenie o przekroju Fouriera
szereg rozdzielczy
tomographic reconstruction
three-dimensional positron emission tomography
Fourier slice theorem
frequency sample distribution
two-dimensional interpolation
inverse distance weighting
gridding method
Opis:
Positron Emission Tomography (PET) is considered a key diagnostic tool in neuroscience, by means of which valuable insight into the metabolism function in vivo may be gained. Due to the underlying physical nature of PET, 3D imaging techniques in terms of a 3D measuring mode are intrinsically demanded to assure satisfying resolutions of the reconstructed images. However, incorporating additional cross-plane measurements, which are specific for the 3D measuring mode, usually imposes an excessive amount of projection data and significantly complicates the reconstruction procedure. For this reason, interpolation-based reconstruction methods deserve a thorough investigation, whose crucial parts are the interpolating processes in the 3D frequency domain. The benefit of such approaches is apparently short reconstruction duration, which can, however, only be achieved at the expense of accepting the inaccuracies associated with the interpolating process. In the present paper, two distinct approaches to the realization of the interpolating procedure are proposed and analyzed. The first one refers to a direct approach based on linear averaging (inverse distance weighting), and the second one refers to an indirect approach based on two-dimensional convolution (gridding method). In particular, attention is paid to two aspects of the gridding method. The first aspect is the choice of the two-dimensional convolution function applied, and the second one is the correct discretization of the underlying continuous convolution. In this respect, the geometrical structure named the Voronoi diagram and its computational construction are considered. At the end, results of performed simulation studies are presented and discussed.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2008, 18, 1; 63-73
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new capitosaur from the Middle Triassic of Spain and the relationships within the Capitosauria
Autorzy:
Fortuny, J.
Galobart, A.
de Santisteban, C.
Powiązania:
https://bibliotekanauki.pl/articles/21637.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Paleobiologii PAN
Tematy:
capitosaur
Middle Triassic
Triassic
Spain
relationship
Capitosauria
paleontology
Temnospondyli
Mastodonsauroidea
phylogenesis
computer tomographic scanning
Anisian
Opis:
Capitosaurs were the largest and homogeneous group of Triassic temnospondyl amphibians with cosmopolitan distribution. However, their interrelationships are debated. The first capitosaur cranial remains found in the Iberian Peninsula were assigned to Parotosuchus; herein, a re−description of this material, together with information on other remains recovered from the same site, enables us to classify them as a new genus: Calmasuchus acri gen. et sp. nov. (Amphibia: Temnospondyli) from the early−to−middle Anisian (early Middle Triassic). This capitosaur had a combination of plesiomorphic and non−plesiomorphic characters, such as posterolaterally directed tabular horns, paired anterior palatal vacuities, and unique morphology of the lower jaw. By cladistic analysis, we propose a new phylogeny for the monophyletic capitosaurs. In the analysis, Capitosauria is supported by seven synapomorphies. Wetlugasaurus is the most basal member of the clade. The score of the Russian taxon Vladlenosaurus alexeyevi resulted in a clade including Odenwaldia and the latter taxa. The Madagascarian Edingerella is the sister taxon of Watsonisuchus. Finally, Calmasuchus acri, the new taxon described here, appears as a more derived form than Parotosuchus. The new genus is the sister taxon of the Cyclotosaurus–Tatrasuchus and Eryosuchus–Mastodonsaurus clades.
Źródło:
Acta Palaeontologica Polonica; 2011, 56, 3
0567-7920
Pojawia się w:
Acta Palaeontologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Region-based processing of volumetric data
Autorzy:
Hućko, M.
Śramek, M.
Powiązania:
https://bibliotekanauki.pl/articles/333404.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
dane objętościowe i tomograficzne
przełom transformacji
region oparty na przetwarzaniu objętości
volumetric and tomographic data
watershed transform
region-based volume processing
Opis:
Measurement of volumetric tomographic data, similar to other measurement techniques, suffers from several classes of artifacts, of which noise presence and the partial volume effect belong to the most prominent ones. These artifacts spoil data analysis and/or visualization, which may, for example in the case of medical imaging, lead to erroneous decisions with severe consequences. We propose a set of tools for region-based processing of volumetric data. Here, the basic entity is a spectrally homogeneous region instead of the traditional voxel. This provides for, on the one hand, higher robustness and, on the other hand, speeds up processing owing to many times smaller amount of elements to work with. Homogeneous regions are in our approach detected by the well-known segmentation by means of the watershed transform. In this paper we present algorithms for streamed computation of watershed transform, which allows for processing of very large data, region-based data smoothing and region merging based on the spectral distance. Further, we present an interactive tool for volume data segmentation and visualization which takes advantage of region hierarchies obtained by a hierarchical watershed transform.
Źródło:
Journal of Medical Informatics & Technologies; 2011, 17; 247-253
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zastosowania analizy tomograficznej w geotechnicznej ocenie gruntów
Autorzy:
Topoliński, S.
Kumor, M.K.
Powiązania:
https://bibliotekanauki.pl/articles/251697.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
geotechnika
analiza tomograficzna
tomograf komputerowy
geotechnics
tomographic analysis
computer tomograph
Opis:
W niniejszym artykule prezentuje się nowe podejście do problemów oceny gruntów metodą nie wymagającą preparatyki próbek, nieniszczącą z zastosowaniem tomografu komputerowego. Praca przedstawia przykładowe wyniki badań dotyczących wykorzystania standardowego medycznego tomografu komputerowego do jakościowej oceny struktury oraz obserwacji mechanizmów zniszczenia kompozytu gruntowego cement/torf. Badania z zastosowania tomografu komputerowego w mikro mechanice gruntów, mają charakter poglądowy, a przedstawione wnioski, stanowią propozycję dalszych kierunkowych prac badawczych.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 1551-1555, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigation of the two-dimensional gas temperature distribution based on tunable diode laser absorption spectroscopy
Autorzy:
Shao, J
Wang, L
Ying, C
Powiązania:
https://bibliotekanauki.pl/articles/174322.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tomographic
modified adaptive algebraic reconstruction technique (MAART)
tunable diode laser absorption spectroscopy (TDLAS)
Opis:
Based on tunable diode laser absorption spectroscopy and modified adaptive algebraic reconstruction technique, two-dimensional tomographic reconstruction was derived for the gas temperature distribution in the range of 600–1400 K in the controlled projections. It is explicitly shown that the quality of temperature reconstruction is heavily dependent on the relative sensitivity of the selected spectrum and the algorithm of modified adaptive algebraic reconstruction technique but independent of the complexity of the present field distribution. When the relative sensitivity is less than 1.5, the accuracy of reconstruction relates to the relative sensitivity of the selected spectrum and improves with the increase in relative sensitivity. When the relative sensitivity is larger than 1.5, the accuracy is mainly limited by the algorithm of modified adaptive algebraic reconstruction technique.
Źródło:
Optica Applicata; 2015, 45, 2; 183-198
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Concept of detection system to localize inside closed area by radio tomographic imaging
Koncepcja systemu detekcji do lokalizacji wewnątrz obszarów zamkniętych z wykorzystaniem tomografii radiowej
Autorzy:
Rymarczyk, T.
Adamkiewicz, P.
Szumowski, J.
Niderla, K.
Gołąbek, Ł.
Sikora, J.
Powiązania:
https://bibliotekanauki.pl/articles/408852.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
beacon
Bluetooth
location inside building
radio tomographic imaging
lokalizacja wewnątrz budynku
tomografia radiowa
Opis:
System for navigation and localization inside buildings will determine man's location in confined spaces with level of accuracy never yet achieved. System's operation will be mainly based on Bluetooth signals in accordance with the Beacon standard. A worldwide innovation will be the use of Radio Tomographic Imaging (RTI). This technology will enable tracking of moving objects by image reconstruction based on changes of electromagnetic field signal strength (RSS).
System do nawigacji wewnątrz budynków będzie umożliwiał określenie pozycji człowieka w zamkniętych pomieszczeniach z dużą precyzją. Działanie systemu będzie opierało się na sygnałach Bluetooth zgodnie ze standardem Beacon.. Innowacyjnym rozwiązaniem będzie zastosowanie tomografii radiowej (ang. Radio Tomographic Imaging (RTI)). Wykorzystanie tej technologii umożliwi śledzenie poruszających się obiektów poprzez rekonstrukcję obrazu na podstawie zmian siły sygnału (RSS) pola elektromagnetycznego.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 92-95
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic Wave Correlation Tomography of Time-Varying Disordered Structures
Autorzy:
Samelsohn, G.
Tapuchi, S.
Powiązania:
https://bibliotekanauki.pl/articles/177920.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wave scattering
random media
time correlation
tomographic reconstruction
Opis:
An original model based on first principles is constructed for the temporal correlation of acoustic waves propagating in random scattering media. The model describes the dynamics of wave fields in a previously unexplored, moderately strong (mesoscopic) scattering regime, intermediate between those of weak scattering, on the one hand, and diffusing waves, on the other. It is shown that by considering the wave vector as a free parameter that can vary at will, one can provide an additional dimension to the data, resulting in a tomographic-type reconstruction of the full space-time dynamics of a complex structure, instead of a plain spectroscopic technique. In Fourier space, the problem is reduced to a spherical mean transform defined for a family of spheres containing the origin, and therefore is easily invertible. The results may be useful in probing the statistical structure of various random media with both spatial and temporal resolution.
Źródło:
Archives of Acoustics; 2018, 43, 4; 647-655
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Program zapewnienia kontroli jakości w medycynie nuklearnej. Testy podstawowe kontroli jakości skanerów PET i PET/CT
Quality Assurance in Nuclear Medicine. Routine tests of quality control of PET and PET/CT systems
Autorzy:
Matuszewski, Krzysztof
Szweda, Hubert
Cegła, Paulina
Radomiak, Dawid
Pawałowski, Bartosz
Powiązania:
https://bibliotekanauki.pl/articles/2146787.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
skaner PET
system kontroli jakości
medycyna nuklearna
stabilność detektora
normalizacja
jednorodność zrekonstruowanego obrazu
kalibracja koncentracji aktywności
jakość obrazu
fantom Jaszczaka
tomograficzna rozdzielczość przestrzenna w powietrzu
dopasowanie cięć
PET system
quality control system
nuclear medicine
PET detector stability
PET normalization
uniformity of the reconstructed image
radioactivity concentration calibration
image quality
Jaszczak phantom
tomographic spatial resolution in air
PET/CT alignment
Opis:
Jednym z warunków zapewnienia i utrzymania wysokiego poziomu jakości badań diagnostycznych w medycynie nuklearnej jest wykonywanie testów kontroli jakości zgodnie z zaleceniami i regulacjami prawnymi. Testy podstawowe kontroli jakości, będące jednym z elementów systemu kontroli jakości w zakładach medycyny nuklearnej, są nieodzowną częścią rutynowej pracy klinicznej. Niniejsza praca ma na celu przedstawienie procedur wykonywania testów podstawowych kontroli jakości dla skanerów PET i PET/CT.
One of the conditions for ensuring and maintaining a high level of quality diagnostic exams in nuclear medicine is to perform quality control tests in accordance with legal recommendations and regulations. Basic quality control tests, which are one of the elements of the quality control system in nuclear medicine departments, are a very important part of routine clinical work. This work aims to present the procedures for performing basic quality control tests for PET and PET/CT scanners.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 6; 459--465
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the accuracy of mapping in computed tomography
Analiza dokładności odwzorowania w tomografii komputerowej
Autorzy:
Ryniewicz, Andrzej
Rysz, Konrad
Bojko, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2130926.pdf
Data publikacji:
2021
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Nowym Sączu
Tematy:
tomographic imaging
phantoms
measurements
radiological density
shape
obrazowanie tomograficzne
fantomy
pomiary
gęstość radiologiczna
kształt
Opis:
The aim of the study is to assess the accuracy of mapping the internal structure and shape of phantoms in computed tomography (CT) imaging, using reconstructive metrology and virtual measurements. The tests material is tomographic imaging of diagnostic phantoms: the head phantom used for monthly calibrations of computer tomographs and the specialized phantom for tests performed once a year. The Materialize Mimics computer program was used to measure the geometry of objects inside the phantoms and to measure the radiological density in the cross-sections of the tested patterns. It is a universal tool for assessing the accuracy of mapping in CT imaging. The results of the measurements were used to perform a complete statistical analysis. The values of standard deviations for the performed measurements did not exceed the limit value, which means that the tested tomograph meets the requirements for homogeneity of imaging and noise level specified in the Regulation of the Minister of Health. The proposed procedure is important for the target device, but can also be a tool for comparing the quality of different tomographs.
Celem pracy jest ocena dokładności odwzorowania struktury wewnętrznej i kształtu fantomów w obrazowaniu tomografią komputerową (CT), z zastosowaniem metrologii rekonstrukcyjnej i pomiarów wirtualnych. Materiałem badań jest obrazowanie tomograficzne fantomów diagnostycznych: fantomu głowy używanego do comiesięcznych kalibracji tomografów komputerowych i fantomu specjalistycznego do testów wykonywanych raz w roku. Do pomiarów geometrii obiektów znajdujących się wewnątrz fantomów oraz pomiarów gęstości radiologicznej w przekrojach badanych wzorców wykorzystano program komputerowy Materialise Mimics. Stanowi on uniwersalne narzędzie do oceny dokładności odwzorowania w obrazowaniu CT. Wyniki pomiarów wykorzystano do przeprowadzenia pełnej analizy statystycznej. Wartości odchyleń standardowych dla wykonanych pomiarów nie przekroczyły wartości granicznej, co oznacza, że badany tomograf spełnia wymogi odnośnie do jednorodności obrazowania i poziomu szumów, ujęte w Rozporządzeniu Ministra Zdrowia. Zaproponowana procedura jest istotna dla docelowego urządzenia, ale może również stanowić narzędzie do porównania jakości różnych tomografów.
Źródło:
Journal of Engineering, Energy and Informatics; 2021, 1; 53-68
2720-4162
2720-5541
Pojawia się w:
Journal of Engineering, Energy and Informatics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of Sub-Surface Defects in Semi-Finished Products from Aluminum Alloys by the Eddy Current Method
Autorzy:
Krysztofik, Józef
Malicki, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/2105181.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
eddy current testing
tomographic testing
subsurface discontinuities
standard depth of penetration
effective depth of penetration
Opis:
The article presents the results of tests aimed at detecting discontinuities in the subsurface layer of elements intended for further processing. For the initial identification of discontinuities, the method of computed tomography was used. Based on the tomographic images of selected typical defects and measurements of the electrical conductivity of the material, the parameters for the eddy current tests were determined. A series of discontinuities in the subsurface layer to a depth of about 0.48 mm were detected. This allowed, at a given stage of machining, relevant elements to be selected for further processing.
Źródło:
Fatigue of Aircraft Structures; 2021, 13; 31--39
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of upper respiratory tract segmentation features to determine nasal conductance
Analiza cech segmentacji górnych dróg oddechowych w celu określenia przewodnictwa nosowego
Autorzy:
Avrunin, Oleg
Nosova, Yana
Shushliapina, Nataliia
Abdelhamid, Ibrahim Younouss
Avrunin, Oleksandr
Kyrylashchuk, Svetlana
Moskovchuk, Olha
Mamyrbayev, Orken
Powiązania:
https://bibliotekanauki.pl/articles/2174750.pdf
Data publikacji:
2022
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
aerodynamics of nasal breathing
nasal cavity
tomographic reconstruction
segmentation
upper respiratory tract
air conduction
aerodynamika oddychania przez nos
jama nosowa
rekonstrukcja tomograficzna
segmentacja
górne drogi oddechowe
przewodzenie powietrza
Opis:
The paper examines the features of segmentation of the upper respiratory tract to determine nasal air conduction. 2D and 3D illustrations of the segmentation process and the obtained results are given. When forming an analytical model of the aerodynamics of the nasal cavity, the main indicator that characterizes the configuration of the nasal canal is the equivalent diameter, which is determined at each intersection of the nasal cavity. It is calculated based on the area and perimeter of the corresponding section of the nasal canal. When segmenting the nasal cavity, it is first necessary to eliminate air structures that do not affect the aerodynamics of the upper respiratory tract - these are, first of all, intact spaces of the paranasal sinuses, in which diffuse air exchange prevails. In the automatic mode, this is possible by performing the elimination of unconnected isolated areas and finding the difference coefficients of the areas connected by confluences with the nasal canal in the next step. High coefficients of difference of sections between intersections will indicate the presence of separated areas and contribute to their elimination. The complex configuration and high individual variability of the structures of the nasal cavity does not allow segmentation to be fully automated, but this approach contributes to the absence of interactive correction in 80% of tomographic datasets. The proposed method, which takes into account the intensity of the image elements close to the contour ones, allows to reduce the averaging error from tomographic reconstruction up to 2 times due to artificial sub-resolution. The perspective of the work is the development of methods for fully automatic segmentation of the structures of the nasal cavity, taking into account the individual anatomical variability of the upper respiratory tract.
W pracy przeanalizowano cechy segmentacji górnych dróg oddechowych w celu określenia powietrznego przewodnictwa nosowego. Przedstawiono zdjęcia 2D i 3D procesu segmentacji oraz uzyskanych wyników. Podczas formowania analitycznego modelu aerodynamiki jamy nosowej głównym wskaźnikiem charakteryzującym konfigurację kanału nosowego jest ekwiwalentna średnica, którą wyznacza się na każdym skrzyżowaniu jam nosowych. Jest ona obliczana na podstawie pola powierzchni i obwodu odpowiedniego odcinka kanału nosowego. Podczas segmentacji jamy nosowej w pierwszej kolejności należy wyeliminować struktury powietrzne, które nie wpływają na aerodynamikę górnych dróg oddechowych – są to przede wszystkim nienaruszone przestrzenie zatok przynosowych, w których dominuje rozproszona wymiana powietrza. W trybie automatycznym jest to możliwe dzięki eliminacji niepołączonych izolowanych obszarów i znalezieniu, w kolejnym kroku, współczynników różnicy obszarów połączonych konfluencjami z przewodem nosowym. Wysokie współczynniki różnic przekrojów pomiędzy skrzyżowaniami będą wskazywały na obecność wydzielonych obszarów i przyczynią się do ich eliminacji. Złożona konfiguracja i duża zmienność osobnicza struktur jamy nosowej nie pozwala na pełną automatyzację segmentacji, jednak takie podejście przyczynia się do braku konieczności interaktywnej korekcji w 80% zestawów danych tomograficznych. Zaproponowana metoda, uwzględniająca intensywność elementów obrazu znajdujących się blisko konturu, pozwala na nawet 2-krotne zmniejszenie błędu uśredniania z rekonstrukcji tomograficznej, wynikającego ze sztucznej subrozdzielczości. Perspektywą pracy jest opracowanie metod w pełni automatycznej segmentacji struktur jamy nosowej z uwzględnieniem indywidualnej zmienności anatomicznej górnych dróg oddechowych.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2022, 12, 4; 35--40
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reverse engineering of research engine cylinder-head
Autorzy:
Cieślik, Wojciech
Szwajca, Filip
Wisłocki, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2097636.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
reverse engineering
research engine
3D measuring system
tomographic measurement
variable valve timing
inżynieria odwrotna
silnik badawczy
trójwymiarowy system pomiarowy
pomiar tomograficzny
zmienne fazy rozrządu
Opis:
The pursuit of increasing the efficiency of internal combustion engines is an ongoing engineering task that requires numerous research efforts. New concepts of injection or combustion systems require preliminary investigation work using research engines. These engines, usually single-cylinder, make it possible to isolate a single variable in a complex combustion mixture preparation process, thus enabling analysis of the changes being made. However, these engines are relatively expensive and their designs are offered by a limited number of manufacturers. The authors of this paper have successfully undertaken the engineering task of modifying an existing research engine cylinder head in such a way as to implement an electronically controlled variable valve timing system of the intake system. The process of reverse engineering, together with design assumptions that finally contributed to the construction of the assumed solution has been described in this paper.
Źródło:
Combustion Engines; 2022, 61, 2; 73--82
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies