Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "time interval measurement" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Quantization error in time-to-digital converters
Autorzy:
Zaworski, Ł.
Chaberski, D.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221677.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval measurement
time-to-digital converter
quantization error
averaging
Opis:
Methods of time interval measurement can be divided into asynchronous and synchronous approaches. It is well known that in asynchronous methods of time-interval measurement, uncertainty can be reduced by using statistical averaging. The motivation of this paper is an investigation of averaging in time interval measurements, especially in a synchronous measurement. In this article, authors are considering the method of averaging to reduce the influence of quantization error on measurement uncertainty in synchronous time-interval measurement systems, when dispersion of results, caused by noise is present. A mathematical model of averaging, which is followed by the results of numerical simulations of averaging of measurement series is presented. The analysis of results leads to the conclusion that in particular conditions the influence of the quantization error on measurement uncertainty can be minimized by statistical averaging, similar to asynchronous measurements.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 115-122
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study of the effect of temperature changes on the interpolating time counter
Autorzy:
Sondej, D.
Szplet, R.
Powiązania:
https://bibliotekanauki.pl/articles/114363.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
time interval measurement
time-to-digital conversion
two-stage interpolation
time counter
Opis:
This paper presents an analysis of the impact of ambient temperature changes on main parameters of the interpolating time counter. The performed tests reveal that a relatively small change in the ambient temperature of 1°C causes a measurement error of the counter as large as 3.5 ps. The thorough research of two stages of interpolation of the counter allowed determining the main sources of the error. One of them is the temperature drift of widths of four-phase clock (FPC) segments in the first interpolation stage (FIS). It equals 2.5 ps/°C. The widths of FPC phases directly influence the active range of the second interpolation stage (SIS) and its offset. The test results also show that the temperature drift of the offset has a greater impact on the measurement accuracy than the temperature-driven changes of quantization steps in SIS. The presented conclusions are the first step to develop a new method for reducing the impact of changes in the ambient temperature on the measurement accuracy of the interpolating time counter.
Źródło:
Measurement Automation Monitoring; 2015, 61, 7; 302-304
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time interval measurement module implemented in SoC FPGA device
Autorzy:
Grzęda, G.
Szplet, R.
Powiązania:
https://bibliotekanauki.pl/articles/226962.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval measurement
time-to-digital converter
system on chip
measurement data processing
Opis:
We presents the design and test results of a picosecond-precision time interval measurement module, integrated as a System-on-Chip in an FPGA device. Implementing a complete measurement instrument of a high precision in one chip with the processing unit gives an opportunity to cut down the size of the final product and to lower its cost. Such approach challenges the constructor with several design issues, like reduction of voltage noise, propagating through power lines common for the instrument and processing unit, or establishing buses efficient enough to transport mass measurement data. The general concept of the system, design hierarchy, detailed hardware and software solutions are presented in this article. Also, system test results are depicted with comparison to traditional ways of building a measurement instrument.
Źródło:
International Journal of Electronics and Telecommunications; 2016, 62, 3; 237-246
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie nieliniowości w precyzyjnym pomiarze przedziału czasu dla wybranych typów częstościomierzy-czasomierzy
Verification of nonlinearities in time interval measurement with a chosen type of time inteval counters
Autorzy:
Urban, A.
Czubla, A.
Osmyk, R.
Szterk, P.
Krehlik, P.
Śliwczyński, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/952793.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
pomiar przedziału czasu
częstościomierz-czasomierz
nieliniowość
niepewność pomiaru
time interval measurement
time interval counter
nonlinearity
measurement uncertainty
Opis:
Celem niniejszego artykułu jest zaprezentowanie metody i wyników badań nad nieliniowością częstościomierzyczasomierzy w pomiarach precyzyjnych przedziałów czasu, prowadzonych w GUM przy współpracy z AGH. Dokonano porównań wyników pomiarów dla częstościomierzy-czasomierzy SR620 i HP 53132A zarówno stałych i zmiennych przedziałów czasu. Potwierdzono przydatność dwukanałowego generatora/dzielnika typu Dual Channel 1/100 PPS Generator oraz komparatora częstotliwości typu A7-MX.
In this paper we present the method and the last results of verification of nonlinearities in time interval measurements with the usage of Time Interval Counters (TIC), performed at Central Office of Measures (GUM) with cooperation of AGH University of Science and Technology. We consider the non-ideal operation of TIC manifested by fluctuations of differences between the current indication of TIC and the real value of the measured time interval. We observed instabilities of indications of TIC, even if the measured time interval is keeping constant. For verification of TIC operation at continuously changed time intervals, it was set up a special measurement system that performs simultaneous measurements of the phasetime changes between two standard frequency signals (with the usage of A7-MX standard frequency comparator) and time intervals between two pulse signals (with the usage of TIC under test). Due to applying a special, developed by AGH, dual channel 1/100 pps generator, the measured 1 pps (1 pulse per second) and 10 MHz signals are standardized and the phasetime between 1 pps and 10 MHz signals are kept in pairs constant. Differences between the indications of TIC and the proper measurement results for frequency allow to verify internal nonlinearities of TIC in time interval measurements. Here, we show and shortly discuss the results obtained for SR620 and 53132A universal counters. The obtained range of fluctuations of indications of SR6200 with relation to the measured time interval approaches about 190 ps, and for 53132A – about 450 ps, whereas the observed short-term noise of measurement for SR620 is about 10 ps, and for 53132A – about 100 ps typically. It was confirmed the complex and random influence of many factors on operation of TIC. Our investigation will be continued with the usage of 100 pps (100 pulses per second) signals and with automatic switching of the measured pulse signals in pairs.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 38; 81-84
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie fluktuacji czasu ustalania przerzutnika
Research of setup time fluctuation of the flip-flop
Autorzy:
Grzelak, S.
Zieliński, M.
Chaberski, D.
Wydźgowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/151245.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
czas ustalania
metastabilność
struktura FPGA
pomiar odcinka czasowego
setup time
metastability
FPGA
time interval measurement
Opis:
Zjawisko metastabilności występujące w przerzutnikach podzielono na dwa różne efekty. Pierwszy dotyczy zwiększonego czasu propagacji, a drugi przypadkowości w ustalaniu stanu wyjściowego. Przedstawiono uogólniony model przerzutnika typu D wyzwalanego zboczem. Zaproponowano metodę pomiaru dodatkowego parametru zinterpretowanego jako poziom fluktuacji czasu ustalania, dla wprowadzonego modelu. Przeprowadzono pomiary przerzutników zaimplementowanych w strukturze FPGA wykonanej w technologii 180 nm. Wartość wprowadzonego parametru w modelu ma znaczenie w wysokorozdzielczej metrologii odcinków czasowych i może wpływać na sumaryczny błąd losowy mierzonego odcinka czasu.
The metastability effect is discussed in this paper as two separated effects. The first concerns the increase of the propagation time and the second concerns the random character of output states. The generalized model of the flip-flop was introduced. The measurements method of the setup time fluctuation is presented. The results of measurements for the flip-flops implemented in the FPGA structure are also discussed.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 695-697
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A High-Speed Fully Digital Phase-Synchronizer Implemented in a Field Programmable Gate Array Device
Autorzy:
Frankowski, R.
Chaberski, D.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221125.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase synchronizer
delay line
coincidence counting
quantum information
time interval measurement
time-to-digital converters
field programmable gate array (FPGA)
Opis:
Most systems used in quantum physics experiments require the efficient and simultaneous recording different multi-photon coincidence detection events. In such experiments, the single-photon gated counting systems can be applicable. The main sources of errors in these systems are both instability of the clock source and their imperfect synchronization with the excitation source. Below, we propose a solution for improvement of the metrological parameters of such measuring systems. Thus, we designed a novel integrated circuit dedicated to registration of signals from a photon number resolving detectors including a phase synchronizer module. This paper presents the architecture of a high-resolution (~60 ps) digital phase synchronizer module cooperating with a multi-channel coincidence counter. The main characteristic feature of the presented system is its ability to fast synchronization (requiring only one clock period) with the measuring process. Therefore, it is designed to work with various excitation sources of a very wide frequency range. Implementation of the phase synchronizer module in an FPGA device enabled to reduce the synchronization error value from 2.857 ns to 214.8 ps.
Źródło:
Metrology and Measurement Systems; 2017, 24, 3; 537-550
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precyzyjny licznik czasu i częstotliwości z interfejsem PCI
Precise time and frequency counter with pci interface
Autorzy:
Kalisz, J.
Jachna, Z.
Szplet, R.
Różyc, K.
Powiązania:
https://bibliotekanauki.pl/articles/208422.pdf
Data publikacji:
2006
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
metrologia czasu
pomiar odcinka czasu
pomiar częstotliwości
rozdzielczość pikosekundowa
interpolator czasu
przetwornik czas-liczba
time metrology
time interval measurement
frequency measurement
picosecond resolution
time interpolator
time-to-digital converter
Opis:
Opisujemy budowę, działanie i wyniki pomiarów testowych precyzyjnego licznika czasu i częstotliwości, zrealizowanego w postaci karty komputerowej z interfejsem PCI. Pomiar odcinka czasu jest realizowany przy użyciu interpolacyjnej metody Nutta i specjalistycznego układu scalonego, wykonanego w technologii CMOS FPGA oraz zawierającego dwa interpolatory czasu. Licznik umożliwia pomiary odcinka czasu z rozdzielczością 200 ps i typowej niepewności pomiarowej ok. 150 ps, oraz pomiary częstotliwości metodą odwrotnościową do 3,5 GHz. Wbudowane są procedury specjalistyczne do kalibracji licznika, korekcji zegara, pomiaru różnicy częstotliwości i dewiacji Allana. Dzięki zastosowaniu szybkiej pamięci buforowej FIFO uzyskano dużą szybkość pomiarów, sięgającą 1.66⋅10⁶ pomiarów na sekundę przy transmisji danych do pamięci FIFO.
We describe the design, operation and test results of a precise time and frequency counter, built as a computer board with PCI interface. The time interval is measured with the use of the Nutt interpolation method implemented in a CMOS FPGA device containing two proprietary time interpolators. The time interval can be measured with a 200 ps resolution and the measurement uncertainty typically of about 150 ps. The frequency can be measured up to 3.5 GHz using the reciprocal method. Special routines have been built-in for counter calibration, clock correction, measurement of frequency difference, and Allan deviation. Thanks to the use of a fast FIFO memory, a high measurement rate has been achieved, reaching 1.66⋅10⁶ measurements per second when transferring data to FIFO memory.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2006, 55, sp.; 43-58
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie interpolacyjnej metody pomiaru odcinka czasu do precyzyjnego pomiaru częstotliwości
Application of time-interval measurement interpolation method for precise frequency measurement
Autorzy:
Jachna, Z.
Szplet, R.
Różyc, K.
Klepacki, K.
Powiązania:
https://bibliotekanauki.pl/articles/209142.pdf
Data publikacji:
2008
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
precyzyjny pomiar odcinka czasu
konwerter czas-liczba
odwrotnościowa metoda pomiaru częstotliwości
przyrządy wirtualne
precise time-interval measurement
time-to-digital converter
reciprocal method for frequency measurement
virtual instruments
Opis:
Przedstawiono problemy projektowe dotyczące implementacji odwrotnościowej metody pomiaru częstotliwości w układzie FPGA. Analizowane są sposoby osiągania wysokiej dokładności przy relatywnie krótkim czasie trwania pomiaru, minimalizacji wartości czasu martwego, maksymalizacji częstotliwości powtarzania pomiarów oraz efektywnym szacowaniu miar statystycznych. Zaprezentowano wyniki badań karty pomiarowej z układem programowalnym Spartan3 (Xilinx), w którym zintegrowane zostały kompletny licznik czasu, pamięć FIFO i układ sterujący.
This paper describes the design problems concerning implementation of the reciprocal method of a frequency measurement in an FPGA device. The following problems are examined: ways of reaching the high accuracy with a relatively short measurement time, minimization of the dead time, maximization of the frequency of measurement repetition, and effective calculation of statistics. Test results of a computer card for frequency measurement are presented. The card is equipped with the precise time counter integrated together with FIFO memory and a control system in the Spartan3 device (Xilinx).
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2008, 57, 2; 277-288
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of an embedded FPGA-based data acquisition system dedicated to zero power reactor noise experiments
Autorzy:
Arkani, M.
Khalafi, H.
Vosoughi, N.
Powiązania:
https://bibliotekanauki.pl/articles/220709.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zero power reactor (ZPR) noise
time interval measurement
probability distribution function (PDF)
field programmable gate array (FPGA)
data acquisition system (DAS)
nuclear reactor
neutron detection
Opis:
An embedded time interval data acquisition system (DAS) is developed for zero power reactor (ZPR) noise experiments. The system is capable of measuring the correlation or probability distribution of a random process. The design is totally implemented on a single Field Programmable Gate Array (FPGA). The architecture is tested on different FPGA platforms with different speed grades and hardware resources. Generic experimental values for time resolution and inter-event dead time of the system are 2.22 ns and 6.67 ns respectively. The DAS can record around 48-bit x 790 kS/s utilizing its built-in fast memory. The system can measure very long time intervals due to its 48-bit timing structure design. As the architecture can work on a typical FPGA, this is a low cost experimental tool and needs little time to be established. In addition, revisions are easily possible through its reprogramming capability. The performance of the system is checked and verified experimentally.
Źródło:
Metrology and Measurement Systems; 2014, 21, 3; 433-446
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PPS Quality Estimation From Different Receivers
Autorzy:
Kubczak, P.
Matuszewski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/114318.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
PPS signal
GPS
GLONASS
frequency source
time interval error
time measurement
synchronization
Opis:
The article presents data analysis of the short-term and long-term-periodic characteristics of the PPS (Pulse Per Second) signal from the navigation systems. The signal arrival time to the Earth was assessed in relation to a high stability frequency source. The basic statistical properties of the signal were calculated, e.g. mean, variance, autocorrelation and actual distributions of random variables were depicted by using a histogram. The differences have been compared between the quality of the signal from the GPS network, the GLONASS network and their combination. The equipment offered by various manufacturers was assessed. Finally, the impact of the MAV filter (Moving Average) on the characteristics of the random variable was examined. At last, but not least, the autocorrelation was checked.
Źródło:
Measurement Automation Monitoring; 2016, 62, 11; 383-386
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies