Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "time descriptors" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Experimental studies for bearings degradation monitoring at an early stage using analysis of variance
Autorzy:
Zarour, D.
Meziani, S.
Thomas, M.
Powiązania:
https://bibliotekanauki.pl/articles/328396.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
ANOVA
DOE
time descriptors
bearing fault
analiza wariancji
łożysko
usterka
deskryptory czasu
Opis:
This work presents a procedure for bearing degradation monitoring at an early stage. The analysis of variance (ANOVA) coupled with Tukey’s test is used to single out the suitable parameters to follow the fault size evolution ranging from 50 µm to 150µm. The Tukey's criterion is adopted in this case to study the ability of time and frequency indicators. The rotational speed, centrifugal load and fault size are considered as independent variables while the time and frequency indicators are taken as dependent variables. The experiments are performed on bearings having a fault on outer race. Based on the results of this study, the Kurtosis and Skewness show a good ability to assess the evolution of degradation in the bearings at an early stage. The paper discusses the weakness of the time and frequency indicators.
Źródło:
Diagnostyka; 2018, 19, 4; 81-87
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High flow, low shear impellers versus high shear impellers; dispersion of oil drops in water and other examples
Autorzy:
Pacek, Andrzej W.
Nienow, Alvin W.
Powiązania:
https://bibliotekanauki.pl/articles/2034043.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
high shear
high flow descriptors
drop sizes
mixing time
bioprocessing
ścinanie
deskryptory wysokiego przepływu
rozmiar kropli
czas mieszania
bioprzetwarzanie
Opis:
Flow patterns generated by two ChemShear impellers, CS 2 and CS 4 have been measured and flow numbers calculated; Fl = 0.04 for both impellers. Transient and equilibrium drop sizes, d32 μm of 3 different viscosity silicone oils agitated by a high-shear Rushton turbine, RT, a low-shear, high-flow HE3 impeller and the two ChemShears were determined. The equilibrium d32 are correlated for all impellers, by d32 = 1300(εT )−0.58 max.svv0.14 with an R2 = 0.94. However, the time to reach steady state and the equilibrium size at the same specific power do not match the above descriptors of each impeller’s characteristics. In other literature, these descriptors are also misleading. In the case of mixing time, a high shear RT of the same size as a high flow HE3 requires the same time at the same specific power in vessels of H/T = 1. In bioprocessing, where concern for damage to cells is always present, free suspension animal cell culture with high shear RTs and low-shear impellers is equally effective; and with mycelial fermentations, damage to mycelia is greater with low shear than high. The problems with these descriptors have been known for some time but mixer manufacturers and ill-informed users and researchers continue to employ them.
Źródło:
Chemical and Process Engineering; 2021, 42, 2; 77-90
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies