Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "timber wall" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Comparing performance of cross-laminated timber and reinforced concrete walls
Autorzy:
Bahrami, A.
Nexen, O.
Jonsson, J.
Powiązania:
https://bibliotekanauki.pl/articles/2106446.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
ściana nośna
ściana żelbetowa
metoda elementów skończonych
cross-laminated timber wall
reinforced concrete wall
load-bearing wall
finite element method
utilisation ratio
Opis:
The purpose of this research is to specify the differences between the performance of cross-laminated timber (CLT) and reinforced concrete (RC) walls. The study is done by using the finite element structural analysis and design software, StruSoft FEM-Design, in order to model, analyse and design a reference building located in the city of Gävle in Sweden. The building is firstly modelled, analysed and designed using RC walls and then the RC walls are replaced with CLT walls. In both buildings, other load-bearing elements such as slabs, beams and columns are made of RC while the roof beams are made of glulam. It is found that employing RC has advantages, especially regarding thickness. The results show that the CLT walls require larger dimensions than their RC counterparts. Meanwhile, it is demonstrated that the slabs, beams and columns made of RC in the building having the CLT walls require more reinforcement or larger thickness than the case of walls made of RC. Moreover, the total weight of the building having the CLT walls is 74% of the building having the RC walls. The lower weight of the building having the CLT walls has great advantages such as having lighter foundation and being cost-effective and also beneficial for the environment.
Źródło:
International Journal of Applied Mechanics and Engineering; 2021, 26, 3; 28--43
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegrody pionowe w budownictwie mieszkaniowym jednorodzinnym
Vertical partitions in housing - single-family
Autorzy:
Drozd, W.
Powiązania:
https://bibliotekanauki.pl/articles/162809.pdf
Data publikacji:
2013
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budownictwo mieszkaniowe
dom jednorodzinny
konstrukcja ściany
ściana drewniana
ściana warstwowa
mur ceramiczny
mur silikatowy
keramzytobeton
residential construction
single-family house
wall structure
timber wall
composite wall
ceramic masonry
calcium silicate masonry
expanded clay aggregate concrete
Opis:
Przegrody pionowe czyli ściany, to obok dachu i fundamentów główne elementy konstrukcyjne budynków. Występują jako ściany wewnętrzne wydzielające pomieszczenia oraz ściany zewnętrzne nadające budynkom architektoniczną formę, wyznaczające im granice i zabezpieczające od wpływów atmosferycznych. W budownictwie mieszkaniowym, jednorodzinnym najczęściej stawia się ściany wykonywane w technologiach drewnianych bądź murowanych. W zależności od projektu korzysta się z elementów drobnowymiarowych ceramicznych, betonowych, betonu komórkowego, silikatów, czy keramzytobetonu. W artykule podjęto próbę porównania najczęściej spotykanych rozwiązań.
Vertical septum is the wall that is next to the roof and the foundations of the main structural components of buildings. Act as internal walls - secreting room and exterior walls - architectural buildings suitable form, defining the boundaries and protection from the weather. In residential buildings, single-family usually puts the walls made of brick or wood technology. Depending on the design of the elements used in small-sized ceramic, concrete, cellular concrete, silicates, or keramzytobetonu. The article tries to compare the most common solutions.
Źródło:
Przegląd Budowlany; 2013, R. 84, nr 4, 4; 32-37
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Construction technology of timber-frame houses resistant to dynamic loads – study on models of exterior walls
Autorzy:
Szczepanski, M.
Migda, W.
Jankowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/102257.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
timber frame house
exterior wall
numerical model
dynamic loads
Opis:
The aim of this paper is to show the numeric representation of experimental studies concerning the behaviour of exterior wall models of a timber-frame house under harmonic loading. A single wall model according to traditional technology of timber-frame house walls (filling with mineral wool) was tested. The analysis was conducted for the following frequencies: 0.5 Hz, 1.0 Hz, 2.0 Hz and 5.0 Hz for various values of the specified displacement. A number of hysteresis loops were obtained for each of the tests. Based on them, the damping ratio as well as stiffness were calculated. The skeleton model filled with mineral wool (traditional technology) experienced serious damage under larger displacements. The results of the study have been used to propose a numerical model of wall filled with mineral wool. The proposed numerical model is consistent with the results for the values obtained during the experimental study, which proves the correctness of the adopted solution.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 28; 75-80
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O celowości rewitalizacji konstrukcji szachulcowych
On the purpose of revitalization of the half-timbered structures
Autorzy:
Przybysz, Edmund
Horbik, Daria
Powiązania:
https://bibliotekanauki.pl/articles/163434.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja szachulcowa
mur pruski
element drewniany
stan techniczny
destrukcja
korozja biologiczna
Poznań
timber-frame construction
half-timbered wall
timber element
technical condition
destruction
biological corrosion
Opis:
W artykule przeanalizowano kilka obiektów o konstrukcji szachulcowej w wieku ponad 100 lat znajdujących się na terenie Wielkopolski. Omówiono ich aktualny stan techniczny, występujące destrukcje elementów drewnianego szkieletu nośnego i stropów drewnianych ze ślepym pułapem, podając główne przyczyny ich złego stanu technicznego: niewłaściwe zabezpieczenie drewna od wpływów zawilgocenia, wywołujące korozję biologiczną, szkodniki drewna, niewłaściwie przeprowadzone remonty i przebudowy wnętrz, wpływ drgań wywołanych zwiększonym ruchem pojazdów, niewłaściwe izolacje lub ich brak na elementach wystających z lica budynku (gzymsy, balkony).
The constructions of several objects with half-timbered structures over 100 years old located in Wielkopolska were analysed in the article. The current technical condition, the occurring destruction of wooden frame elements and wooden ceilings with a blind ceiling, giving as a main reason for their poor technical condition were taken into consideration, it means: improper protection of wood against the influence of moisture, causing biological corrosion, wood pests, improper repairs and interior conversions, impact of vibrations caused by increased vehicle traffic, improper insulation or lack of insulation on elements protruding from the face of the building (e.g. cornices, balconies).
Źródło:
Przegląd Budowlany; 2019, 90, 9; 36-41
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies