Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tilt test" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Gender differences in circulatory adjustment to head-up tilt test in health
Autorzy:
Rimi, S.A.
Rezwana, I.
Sultana, S.
Ferdousi, S.
Powiązania:
https://bibliotekanauki.pl/articles/2087921.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Opolski. Instytut Nauk o Zdrowiu
Tematy:
male
female
tilt test
SBP
DBP
Opis:
Background: A tilt table test is a useful, non-invasive technique that has been used for the last few decades to detect autonomic failure. The response to tilting may vary physiologically between sexes. Aim of the study: To assess the gender-specific changes in cardiovascular response to a tilt test in healthy subjects. Material and methods: This experimental study was conducted on 90 healthy males and females aged 18–60 years, from 2019 to 2020. Forty-five male subjects and 45 female subjects were included. Using a motorized tilt table, a tilt table test was performed at 60 degrees for 10 minutes. An automatic sphygmomanometer was used to measure blood pressure (BP), and heart rate (HR) and a pulse oximeter was used for the measurement of peripheral capillary oxygen saturation (SpO₂). An independent sample t test, a multiple regression analysis and a chi squared test were conducted for statistical analyses. Results: A significantly greater drop in systolic blood pressure (SBP) was observed in females, compared to males after tilting. In 5.5% of the subjects, orthostatic intolerance occurred, but there were no significant age or gender- specific differences in subjects with orthostatic intolerance. Conclusions: This study concluded that in response to tilting, cardiovascular response was less pronounced in females.
Źródło:
Medical Science Pulse; 2020, 14, 2; 10-14
2544-1558
2544-1620
Pojawia się w:
Medical Science Pulse
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tilt test of a pallet load unit – simulation studies
Autorzy:
Matyja, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2091126.pdf
Data publikacji:
2020
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
tilt test
load unit
stability
simulation model
test pochyleniowy
jednostka ładunkowa
stabilność
model symulacyjny
Opis:
This paper presents a dynamic model of a palletised load unit during a static tilt test. The stability (also called rigidity) of a load unit was evaluated. The palletised load unit was built of packages forming layers and protected against disintegration by stretch film. The aim of this study was to compare the results of a static tilt test with a commonly used and recommended dynamic acceleration test.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2020, 107; 107--117
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of heart rate variability during head-up tilt-test in patients with vasovagal syncope
Autorzy:
Budrejko, Szymon
Kempa, Maciej
Chmielecka, Monika
Kozłowski, Dariusz
Raczak, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/895735.pdf
Data publikacji:
2018-09-28
Wydawca:
Gdański Uniwersytet Medyczny
Tematy:
tilt table test
syncope
vasovagal syncope
heart rate variability
Opis:
Introduction: Syncope is defined as transient loss of consciousness, due to decrease in brain perfusion. The most frequent mechanism is vasovagal syncope. In many patients, the cause of syncope remains unspecified, despite an extensive diagnostic work-up. Tilt-test (TT) is an acknowledged diagnostic tool for syncope. Currently, the so-called Italian protocol of TT is most widely used. Vasovagal syncope is caused by impaired circulatory regulation in response to orthostatic stress. One of the available tools to examine the influence of the nervous system on the circulation is the analysis of heart rate variability (HRV). Despite numerous publications concerning HRV parameters and autonomic regulation in patients with syncope, direct comparisons and metaanalysis of the results is impossible, due to variability of TT protocols and study group specifications. Aim of the study: As there is no uniform model of HRV during TT, we aimed to analyze HRV parameters during TT (performed according to the Italian protocol) in patients with vasovagal syncope, in order to determine the possible application of HRV measurements in clinical practice in that group of patients. Detailed objectives were: (1) analysis and comparison of HRV in patients with and without the history of syncope; (2) analysis of HRV changes in consecutive stages of TT; (3) identification of possible HRV differences between patients with positive and negative TT results. Materials and methods: Patients between 18 and 50 years of age were qualified for the study, if they had a history of at least 2 incidents of syncope or presyncope within the preceeding 6 months, and if signs and symptoms indicated the vasovagal mechanism. The study group included 150 patients: 100 consecutive patients with a postive TT result (POS), and 50 consecutive patients with a negative TT result (NEG). The control group (CG) comprised 50 volunteers with no history of syncope nor presyncope, matched according to age and sex to the study group. In all patients a TT was performed according to the Italian protocol, with paced breathing at a rate of 15/min. Time-domain (meanRR, SDNN, RMSSD, pNN50) and frequency-domain (abs_LF, abs_HF, rel_LF, rel_HF, norm_LF, norm_HF, LF/HF) HRV parameters were analyzed and compared at different stages of TT in the study groups as specified above. Results: 100 patients at the age of 18-44 years were included in the POS group, 50 patients at the age of 18-39 years in the NEG group, and 50 volunteers at the age of 20-39 in the CG. Volunteers in the control group developed unexpectedly high percentage of positive TT (14 patients). For consistency of analysis, the CG was thus subdivided according to the result of the TT into CG_POS (positive result of TT) – 14 patients, and CG_NEG (negative result of TT) – 36 patients. Based on HRV analaysis, no significant differences in HRV values were noted between patients with a history of syncope and positive or negative result of TT. Upright tilt resulted in HRV changes of the same direction and value in syncopal patients in the POS and NEG goup, as well as in patients in the CG_NEG group. Conclusion: HRV values and changes of those values at subsequent stages of TT were not different between syncopal patients with postive or negative TT result, or negative TT control group. The Italian protocol of TT may be associated with a surprisingly high percentage of false positive results.
Źródło:
European Journal of Translational and Clinical Medicine; 2018, 1, 1; 26-38
2657-3148
2657-3156
Pojawia się w:
European Journal of Translational and Clinical Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dual-axis test rig for Mems tilt sensors
Autorzy:
Łuczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/220491.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tilt sensor
accelerometer
MEMS
uncertainty of measurement
test rig
Opis:
The paper addresses the problem of experimental studies of miniature tilt sensors based on low-range accelerometers belonging to Microelectromechanical Systems (MEMS). A custom computer controlled test rig is proposed, whose kinematics allows an arbitrary tilt angle to be applied (i.e. its two components: pitch and roll over the full angular range). The related geometrical relationships are presented along with the respective uncertainties resulting from their application. Metrological features of the test rig are carefully evaluated and briefly discussed. Accuracy of the test rig is expressed in terms of the respective uncertainties, as recommended by ISO; its scope of application as well as the related limitations are indicated. Even though the test rig is mostly composed of standard devices, like rotation stages and incremental angle encoder, its performance can be compared with specialized certified machines that are very expensive. Exemplary results of experimental studies of MEMS accelerometers realized by means of the test rig are presented and briefly discussed. Few ways of improving performance of the test rig are proposed.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 351-362
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wysoki poziom lęku u pacjentów, u których podejrzewano, ale wykluczono podejrzenie omdleń wazowagalnych
High anxiety level in patients with suspected but excluded vasovagal syncope
Autorzy:
Szewczuk-Bogusławska, Monika
Zyśko, Dorota
Kaczmarek, Małgorzata
Kumar Agrawal, Anil
Rudnicki, Jerzy
Gajek, Jacek
Federowski, Artur
Powiązania:
https://bibliotekanauki.pl/articles/470138.pdf
Data publikacji:
2012
Wydawca:
Europejskie Centrum Kształcenia Podyplomowego
Tematy:
omdlenia wazowagalne
test pochyleniowy
lęk
vasovagal syncope
tilt testing
anxiety
Opis:
Wstęp. Pacjenci kierowani na test pochyleniowy, u których wykluczono omdlenia wazowagalne, są grupą mało poznaną. Objawy zaburzeń lękowych i prodromalne objawy omdlenia wazowagalnego nakładają się na siebie, co może utrudniać rozpoznanie. Cel pracy. Ocena poziomu lęku w grupie młodych kobiet, u których na podstawie wywiadu i wyniku testu pochyleniowego wykluczono występowanie omdleń wazowagalnych. Materiał i metody. Grupa badana składała się z 14 kobiet, które pochodziły z grupy 55 kobiet kierowanych na test pochyleniowy w wieku 21–40 lat, u których na podstawie wywiadu i wyniku testu pochyleniowego wykluczono występowanie omdleń wazowagalnych. Przed wykonaniem testu pochyleniowego u badanych kobiet przeprowadzono badanie z użyciem kwestionariusza Spilbergera i oceniono poziom lęku jako stanu (KS1) i jako cechy (KS2). Grupę kontrolną stanowiły 124 kobiety, które zaprzeczały występowaniu omdleń w wywiadzie, które anomimowo wypełniły kwestionariusz Spilbergera oraz kwestionariusz dotyczący stanu zdrowia. Wyniki. Stwierdzono: 1) istotnie wyższy poziom lęku jako cechy i stanu (KS1 i KS2) w grupie badanej niż w grupie kontrolnej, 2) wartość poziomu lęku jako stanu (KS1) ponad 32 ze 100% czułością i 34,7% swoistością pozwala odróżnić pacjentów z grupy badanej od osób z grupy kontrolnej, 3) wartość poziomu lęku jako cechy (KS2) ponad 44 ze 64,3% czułością i 74,2% swoistością pozwala odróżnić pacjentów z grupy badanej od osób z grupy kontrolnej. Wnioski. 1. U około 20% pacjentek kierowanych na test pochyleniowy wykonanie badania i ocena zgłaszanych dolegliwości oraz reprodukcji objawów spontanicznych podczas testu pochyleniowego pozwala na wykluczenie omdleń wazowagalnych jako przyczyny zgłaszanych dolegliwości. 2. U pacjentek w grupie badanej stwierdza się wysoki poziom lęku jako cechy i jako stanu, co wskazuje na możliwość występowania zaburzeń lękowych jako podłoża zgłaszanych dolegliwości. 3. Wykluczenie rozpoznania omdleń wazowagalnych u młodych kobiet kierowanych z takim podejrzeniem na test pochyleniowy powinno zwrócić uwagę na możliwość występowaniu u nich zaburzeń lękowych.
Background. Patients referred for tilt test, who did not have vasovagal syncope are little known group. Symptoms of anxiety disorders and prodromal symptoms of vasovagal syncope overlap which can make it difficult to recognize. Objectives. The aim of the study is to assess the level of anxiety in a group of young women with excluded vasovagal syncope on the basis of medical history and tilt test results. Material and methods. The study group consisted of 14 women who came from a whole group of 55 women at the age of 21–40 years referred for tilt testing, who were excluded the presence of vasovagal syncope. Before performing the tilt test at the women were surveyed using a questionnaire Spielberg and rated the level of state anxiety (KS1) and the trait anxiety (KS2). Control group consisted of 124 women who had denied the occurrence of syncope. Results. 1. Results found significantly higher levels of trait anxiety and state anxiety (KS1 and KS2) in the study group than in the control group: 2. It was found that the value of the level of state anxiety (KS1) over 32 with 100% sensitivity and 34.7% specificity allows to distinguish case patients from the control group. 3. It was found that the value of the level of trait anxiety (KS2) over 44 with 64.3% sensitivity and 74.2% specificity allows to distinguish case patients from the control group. Conclusions. 1. Approximately 20% of patients referred for tilt testing have excluded vasovagal syncope as the cause of reported problems. 2. Patients in the study group found a high level of anxiety as a trait and as a state which indicates the possibility of anxiety as substrate of their complaints. 3. Exclusion of vasovagal syncope diagnosis in young women should pay attention to the possibility of the occurrence of anxiety disorders in them.
Źródło:
Współczesne Pielęgniarstwo i Ochrona Zdrowia; 2012, 3; 50-54
2084-4212
Pojawia się w:
Współczesne Pielęgniarstwo i Ochrona Zdrowia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies