Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal pump" wg kryterium: Temat


Tytuł:
Modeling of Joint Operation of a Ground Soil Heat Exchanger and a Thermal Pump Evaporator
Autorzy:
Sydorchuk, Bogdan
Naumchuk, Oleksandr
Mazurek, Paweł A.
Powiązania:
https://bibliotekanauki.pl/articles/1839101.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ground heat exchanger
thermal pump
Opis:
The development of civilization is associated with an increase in demand for energy. Nowadays, the technologies using renewable energy sources are particularly important. The heating systems powered by heat pumps are increasingly used. The article presents an integrated mathematical model that takes into account the joint operation of the ground heat exchanger and the internal circuit of the heat pump. Modeling was done in Matlab environment. The modeling results allow optimizing the evaporator design in order to effectively use the heat pump.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 256-261
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The fresh waters of the Krakow region as the lower source for heat pumps
Autorzy:
Uliasz-Misiak, B.
Winid, B.
Chodań, E.
Powiązania:
https://bibliotekanauki.pl/articles/299054.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
groundwater
heat pump
temperature
thermal power
Krakow
Opis:
Krakow is a city facing a big problem with air pollution, the use of energy accumulated in groundwater may contribute to reducing emissions of gases and dust to the atmosphere. The article analyzes the possibilities of using groundwater made available with intakes located in Krakow. Estimated water temperatures were ranging from 7.9 to 9.7°C. The thermal power that can be obtained in groundwater varies for individual intakes and allows for obtaining thermal outputs from 0.395 to 1108.035 kW, according to calculations. The analysis of groundwater chemistry in the Krakow region and their comparison with the recommendations of heat pump manufacturers indicates that the use of water as a lower heat source may in some cases cause technical problems.
Źródło:
AGH Drilling, Oil, Gas; 2018, 35, 1; 187-200
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of control system for central heating boiler
Autorzy:
Huścio, Tomasz
Powiązania:
https://bibliotekanauki.pl/chapters/32304181.pdf
Data publikacji:
2021
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
solar thermal collectors
biomass boiler
heat pump
Opis:
Air pollution is the most harmful to health and the environment out of all types of pollution. Boiler designs with modern burners, fired by biomass, should be characterized by high energy efficiency and compliance with environmental protection standards. The efficiency of the combustion process is determined by the amount of heat obtained. The quality of the combustion process can be evaluated by the efficiency of the fuel processing equipment. The higher the efficiency, the more energy is obtained from combustion of a unit of fuel. One should also remember that, for the purpose of minimizing environmental hazards, besides modern boiler and burner designs, selection of fuel of proper quality and correct selection of flue gas discharge installations, the designing and implementation of an appropriate control system is also necessary. Inadequate control system solutions result in elevated emissions of harmful substances into the atmosphere and reduces the efficiency of the combustion process, which increases operating costs as a result.
Źródło:
Methods and tools in CAD – selected issues; 145-155
9788366391871
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flame spraying "Roto-Teck 80" of Ni-Al and Ni-Al-Al2O3 coatings surface texture after roller burnishing
Autorzy:
Starosta, R.
Powiązania:
https://bibliotekanauki.pl/articles/246267.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
thermal spay coatings
burnishing
roughness
material ratio
torque pump
Opis:
The process of flame sprayed is a technology affordable and easy to implement. It does not require greats kill of the operator. This method is not associated with expensive workstation equipment. It may the refore be used with success for the regeneration of machine parts by the crew of vessel engine room. Flame spray ed coatings are characterized by porosity, oxide inclusions presence and large real area of surface. In order to obtain adequate surface roughness coatings must be applied finishing. For this purpose, the turning and grinding are used. In the paper a burnishing to finishing flame sprayed coatings was proposed. Burnishing is not used during the processing of thermally sprayed coatings, as is commonly believed that this technology causes damage to coatings. Coatings of Ni-5% Al and Ni-5%Al-15%Al2O3 obtained by powder flame spraying were studied. Torch of "Roto-Teck 80" was used. After turning the average value of surface coatings roughness coefficient Ra = 3 mi m was obtained. SRMD burnishing tool produced by "Yamato" company was used. Roller burnishing was performer on engine lathe. It was found that the increase in burnishing force and the reduction of burnishing speed and feed rate of less roughness of coatings are obtained. For Ni-5%Al coatings the lowest surface roughness, Ra = 0.3 /mi m was obtained after burnishing with the following parameters: the force - 1100 N, rate - 28m/min, feed - 0.08 mm/rev. During burnishing of Ni-5% Al-15% - A12O3 coatings applied force 700 N, Ra = l pm was obtained. Greater burnishing force caused coatings damage. Burnishing compared to turning has positive influence on the curve shape of the material ratio. It was found that the parameters Rk, Rpk and Rpk were reduced.
Źródło:
Journal of KONES; 2010, 17, 4; 477-484
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Balance of the Magneto-Hydro-Dynamic Pump for Recovery of Platinum Group Metals from Spent Auto Catalysts
Autorzy:
Gil, S.
Bialik, W.
Saternus, M.
Fornalczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/356349.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal balance
magneto-hydro-dynamic pump
platinum group metals
Opis:
Every new car should be equipped with the catalyst, which limits the amount of harmful chemical compounds such as NOx, CH and CO emitted to the air. Auto catalyst consists of the ceramic or metallic carrier, on which is the layer with Platinum Group Metals playing catalytic role. There are many methods using for recovery those valuable metals from spent auto catalyst, however evry of those methods have some limitations. Proces described in the article is the modified method of metal collector, which used magnetohydrodynamic pump. Rotary electromagnetic field generates in the liquid metal rotary current, which as a consequence washing out the PGM metals from the ceramic carriers. Considering the possibilities of commercialization of the described method, the energy balance was made. From that balance the energetic efficiency of the unit was determined and the analysis of the temperature distribution was shown thermographycally.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 1; 253-256
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the heat pump for a passenger electric vehicle based on refrigerant R744
Autorzy:
Canteros, Maria Laura
Polansky, Jiri
Powiązania:
https://bibliotekanauki.pl/articles/2091374.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
R744 (CO2)
heat pump
battery electric vehicle
thermal comfort
Opis:
Energy management plays a crucial role in cabin comfort as well as enormously affects the driving range. In this paper energy balances contemplating the implementation of a heat pump and an expansion device in battery electric vehicles are elaborated, by comparing the performances of refrigerants R1234yf and R744, from –20◦C to 20◦C. This work calculates the coefficient of performance, energy requirements for ventilation (from 1 to 5 people in the cabin) and energy required with the implementation of a heat pump, with the employment of a code in Python with the aid of CoolProp library. The work ratio is also estimated if the work recovery device recuperates the work during the expansion. Comments on the feasibility of the implementation are as well explicated. The results of the analysis show that the implementation of an expansion device in an heat pump may cover the energy requirement of the compressor from 27% to more than 35% at 20◦C in cycles operating with R744, and from 15% to more than 20% with refrigerant R1234yf, considering different compressor efficiencies. At –20◦C, it would be possible to recuperate between around 30 and 24%. However, the risk of suction when operating with R1234yf at ambient temperatures below –10◦C shows that the heat pump can only operate with R744. Thus, it is the only refrigerant that achieves the reduction of energy consumption at these temperatures.
Źródło:
Archives of Thermodynamics; 2022, 43, 2; 17--36
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of various control techniques for motor-pump sets applied in selected water distribution systems
Autorzy:
Popenda, A.
Powiązania:
https://bibliotekanauki.pl/articles/1372738.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrociepłownia
system dystrybucji wody
pompa
thermal-electric power station
water distribution system
pump
Opis:
The water distribution system applied in the thermal-electric power station EC Tychy SA is analyzed. The economical aspects of various control techniques for motor-pump sets in the aforementioned system are presented in the paper on the example of pumps working out of the cold season. The reasons of control losses occurring in the present system are depicted. The way of improvement of control effectiveness is proposed but unprofitability of the investment is also shown. A control of pumps by throttling and control by rotational speed changes are compared in the paper. It is shown that control by rotational speed changes causes similar losses like control by throttling if application of variable-speed technique is not preceded by appropriate adaptation of water distribution system, especially by adjustment of pump rated parameters.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2011, 4, 92; 97-101
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detailed Energy Audit of Thermal Power Plant Equipment
Autorzy:
Das, Sourabh
Mukherjee, Mainak
Mondal, Surajit
Powiązania:
https://bibliotekanauki.pl/articles/1193916.pdf
Data publikacji:
2015
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Energy Audit
Energy Conservation
Lighting Audit
Motor Audit
Pump Audit
Thermal Power Plant
Transformer Audit
Opis:
Energy audit is a technique developed to reduce unnecessary usage of energy, control and also streamline processes leading to energy efficiency. Energy audit and its impact on a daily basis is high and hence is of good significance. Energy Conservation over the years has been a key in terms of saving excessive bills and building up unnecessary usage both domestically and industrially. The world is not completely energy efficient yet, it should be a made sure that the process to ensure optimum usage and saving wherever possible. In this paper we shall discuss in brief about energy audit in a thermal power plant, techniques and ways data are obtained. India’s strive for complete energizing is yet on the verge of completion, need for saving unused energy and also recovering waste energy can be beneficial in developing an energy content environment. The energy audit carried out in thermal power plant gives a presentation of the data and corners of collecting data.
Źródło:
World Scientific News; 2015, 22; 70-90
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiz poroga ekonomiceskoj celesoobraznosti ekspluatacii TES i puti ich vozmoznoj modernizacii na primere vnedrenia castotnych preobrazovatelej dla pitatel’nych elektronasosov
Analysis of an economic feasibility threshold of TPP and ways of possible modernization of TPP on the example of the introduction of frequency converters for feeding pumps
Autorzy:
Pogosov, A.
Prijmak, A.
Malkin, E.
Kulinko, E.
Powiązania:
https://bibliotekanauki.pl/articles/2065364.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
pompy zasilające
turbiny parowe
regulacja częstotliwości
moc termiczna
thermal power plant
steam turbine
feeding pump
frequency regulation
Opis:
V stat’e privedeny rezul’taty analiza poroga ekonomiceskoj celesoobraznosti ekspluatacii teplovych elektrostancij, kotoryj pozvolaet opredelit’ ekonomiceski obosnovannye sroki podlenia raboty TES, a takze pokazyvaet rentabel’nyj uroven’ zatrat topliva na vyrabotku elektriceskoj energii. Vo vtoroj casti stat’i privedeny techniko-ekonomiceskie pokazateli vnedrenia castotnych preobrazovatelej dla pitatel’nych elektronasosov, kak odin iz celesoobraznych sposobov modernizacii TES.
This article presents the results of the economic feasibility analysis of the threshold operation of thermal power plants (TPP). The determination of an economic feasibility threshold makes it possible to estimate an economically reasonable extension of TPP lifetime and shows reasonable fuel cost level for electricity generation. The second part of the article shows the technical and economic performance of an introduction of frequency converters for feeding pump as one of the appropriate methods of modernization of TPP.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 2 (16); 63--69
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations into the influence of functional parameters of a heat pump on its thermal efficiency
Badanie wpływu parametrów funkcjonalnych pompy ciepła na wydajność cieplną
Autorzy:
Szreder, M.
Powiązania:
https://bibliotekanauki.pl/articles/792384.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heat pump
functional parameter
vertical collector
thermal efficiency
scroll type compressor
evaporator
condenser
heat source
coefficient performance
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie hybrydowych kolektorów fotowoltaicznych PVT w systemach przygotowania ciepłej wody użytkowej i centralnego ogrzewania w budynkach jednorodzinnych
Use of PVT hybrid solar collectors in hot water and central heating systems in single-family buildings
Autorzy:
Rozpondek, Maciej
Kapsrzyk, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/115398.pdf
Data publikacji:
2018
Wydawca:
Wyższa Szkoła Techniczna w Katowicach
Tematy:
hybrydowe kolektory fotowoltaiczne PVT
systemy grzewcze
systemy wentylacyjne
pompa ciepła
photovoltaic thermal hybrid solar collectors
heating systems
ventilation systems
heat pump
Opis:
Przeanalizowano sposoby zastosowania hybrydowych kolektorów fotowoltaicznych PVT do wytwarzania energii elektrycznej i ciepłej wody użytkowej. Zaprezentowano schematy procesowe instalacji ciepłowniczej dla domu jednorodzinnego wykorzystującej powietrzną pompę ciepła z wymiennikiem zasilanym z wodnych hybrydowych paneli fotowoltaicznych PVT. Opracowano schemat procesowy instalacji grzewczej z udziałem fotowoltaicznej I termicznej pompyciepła PVT-HP zwbudowanym parownikiem pompyciepła orazzespolonej z magazynem ciepła. Zaprezentowano uniwersalne rozwiązanie wykorzystujące możliwość kompleksowego wykorzystania dwuobiegowej fotowoltaicznej I termicznej pompy ciepła w układzie z gruntowym wymiennikiem ciepła w systemie wentylacyjnym.
Methods of using PVT hybrid solar collectors to generate electrical energy and hot tap water were analyzed. The process diagrams of heating installation for a single-family house using an air-to-water heat pump with an interchanger powered by water-based hybrid PVT solar panels were presented. A process diagram of heating installation with the use of a PVT-HP solar thermal / heat pump with a built-in heat pump evaporator, combined with heat storage was developed. A universal solution using the capability of a complex use of a two-speed photovoltaic / thermal heat pump in a system with a ground heat interchanger in a ventilation system was presented.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach; 2018, 10; 91-104
2082-7016
2450-5552
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of variable insulating power of a storing tank on energy effects in the conversion system of solar radiation
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/793373.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
solar collector
heat pump
storing tank
insulation
solar radiation
conversion
hybrid system
thermal balance
energy stream
water temperature
daily change
heat balance
analysis
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature changes in heat pump horizontal ground source
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/60337.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
heat pump
ground massif
horizontal heat exchanger
heat potential
soil
thermal potential
heating period
ground temperature
temperature distribution
heat transfer
energy conservation
Opis:
The paper deals with assessment of thermal fields and temperature changes in ground massif with horizontal heat exchanger used as a heat source for a heat pump. Temperatures in the zone of the horizontal ground exchanger are compared with temperatures in a reference land. Changes of heat potential of the soil during the heating period are also assessed. Possibilities of recovery of thermal potential of the ground massif when utilizing vertical and horizontal exchangers are analyzed in the opening part of the paper. The results of the first verification indicated that average temperatures in the horizontal planes of the ground massif did not differ considerably with distance from the exchanger tube. Differences in average temperatures in reference and experimental lands confirmed sufficient heat potential of the ground massif even at the peak of the heating period. The differences in average temperatures reached up to 6.51 K in the end of the heating period while at the beginning of the heating period, the differences in average temperatures dropped to 1.35 K. The differences between maximum and minimum temperatures in the zone of the ground exchanger reached up to 1.9 K at the peak of the heating period and rose to 3.9 K at the beginning and end of the heating period. The first results of our measurements indicate the necessity of accumulation of thermal energy in the soil massif in the summer period like in case of the vertical exchangers.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 07
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of conditions for loss of bearing capacity of underground ammonia pipelines based on the monitoring data and flexible search algorithms
Autorzy:
Mysiuk, R.V.
Yuzevych, V.M.
Yasinskyi, M.F.
Kniaz, S.V.
Duriagina, Z.A.
Kulyk, V.V.
Powiązania:
https://bibliotekanauki.pl/articles/24200550.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
underground ammonia pipeline
pump station
thermal background
corrosion current
data processing
cloud computing
podziemny rurociąg amoniaku
stacja pomp
tło termiczne
prąd korozyjny
przetwarzanie danych
chmura obliczeniowa
Opis:
Purpose: The study aims to diagnose the corrosion current density in the coating defect on the outer surface of the ammonia pipe depending on the distance to the pumping station, taking into account the interaction of media at the soil-steel interface and using modern graphical data visualization technologies and approaches to model such a system. Design/methodology/approach: The use of an automated system for monitoring defects in underground metallic components of structures, in particular in ammonia pipelines, is proposed. The use of the information processing approach opens additional opportunities in solving the problem of defect detection. Temperature and pressure indicators in the pipeline play an important role because these parameters must be taken into account in the ammonia pipeline for safe transportation. The analysis of diagnostic signs on the outer surface of the underground metallic ammonia pipeline is carried out taking into account temperature changes and corrosion currents. The parameters and relations of the mathematical model for the description of the influence of thermal processes and mechanical loading in the vicinity of pumping stations on the corresponding corrosion currents in the metal of the ammonia pipeline are offered. Findings: The paper evaluates the corrosion current density in the coating defect on the metal surface depending on the distance to the pumping station and the relationship between the corrosion current density and the characteristics of the temperature field at a distance L = 0…20 km from the pumping station. The relative density of corrosion current is also compared with the energy characteristics of the surface layers at a distance L = 0…20 km from the pumping station. An information system using cloud technologies for data processing and visualization has been developed, which simplifies the process of data analysis regarding corrosion currents on the metal surface of an ammonia pipeline. Research limitations/implications: The study was conducted for the section from the pumping station to the pipeline directly on a relatively small data set. Practical implications: The use of client-server architecture has become very popular, thanks to which monitoring can be carried out in any corner of the planet, using Internet data transmission protocols. At the same time, cloud technologies allow you to deploy such software on remote physical computers. The use of the Amazon Web Service cloud environment as a common tool for working with data and the ability to use ready-made extensions is proposed. Also, this cloud technology simplifies the procedure of public and secure access to the collected information for further analysis. Originality/value: Use of cloud environments and databases to monitor ammonia pipeline defects for correct resource assessment.
Źródło:
Archives of Materials Science and Engineering; 2022, 115, 1; 13--20
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości wykorzystania płytkich wód podziemnych kościerskiej wyspy morenowej do sezonowego magazynowania chłodu i ciepła
Assessment of the shallow groundwater potential of the Kościerzyna morainic island for cold and heat seasonal energy storage
Autorzy:
Lemoine, Gérard
Powiązania:
https://bibliotekanauki.pl/articles/2076126.pdf
Data publikacji:
2021
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
magazynowanie energii cieplnej
ATES
pompa ciepła na wodę gruntową
moc chłodnicza brutto
powiat kościerzyński
aquifer thermal energy storage
groundwater heat pump
gross cooling power
Kościerzyna district
Opis:
Low-temperature aquifer thermal energy storage (LT-ATES) is widely used on an industrial scale in the Netherlands. In Poland, where the Polish Lowlands were recently typed as a promising area in this respect, this method has not yet been tested. Because of the complex structure of subsurface geological formations of most parts of these lowlands, assessment of the technical and economic feasibility of this type of energy storage requires extensive investigations. In this study, the ATES potential of an area of a geodetic precinct size was assessed using the basic documentation, especially the “Hydrogeological Map of Poland” with explanations. As a study area, the Kościerzyna morainic island was selected which is the main pole of development of southern Kashubia. The results of the assessment show that, in addition to economic advantages, this area has favourable hydrogeological conditions for LT-ATES due to its location between the Kashubian Lake District morainic complex and the Tuchola Forest outwash plain. In this area, subject to appropriate engineering research, the investment of LT-ATES systems with a few megawatt cooling capacity is entirely possible. This paper presents the most important conclusions of the study which was submited to the archives of the Polish Geothermal Association in Kraków at the beginning of June 2020 (Lemoine, 2020).
Źródło:
Przegląd Geologiczny; 2021, 69, 10; 697--701
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies