Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal power plant" wg kryterium: Temat


Tytuł:
Optimal coefficient of the share of cogeneration in the district heating system cooperating with thermal storage
Autorzy:
Ziębik, A.
Gładysz, P.
Powiązania:
https://bibliotekanauki.pl/articles/240214.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrociepłownia
kogeneracja
sieć ciepłownicza
współczynnik udziału kogeneracji
zasobnik ciepła
coefficient of the share of cogeneration
cogeneration
combined heat and power plant
district heating system
thermal storage
Opis:
The paper presents the results of optimizing the coefficient of the share of cogeneration expressed by an empirical formula dedicated to designers, which will allow to determine the optimal value of the share of cogeneration in contemporary cogeneration systems with the thermal storages feeding the district heating systems. This formula bases on the algorithm of the choice of the optimal coefficient of the share of cogeneration in district heating systems with the thermal storage, taking into account additional benefits concerning the promotion of high-efficiency cogeneration and the decrease of the cost of CO2 emission thanks to cogeneration. The approach presented in this paper may be applicable both in combined heat and power (CHP) plants with back-pressure turbines and extraction-condensing turbines.
Źródło:
Archives of Thermodynamics; 2011, 32, 3; 71-87
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical method for determining the allowable medium temperature during transient operation of a thick-walled boiler element in power plant
Autorzy:
Rząsa, D.
Duda, P.
Powiązania:
https://bibliotekanauki.pl/articles/240222.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia
naprężenie cieplne
optymalizacja
wymiana ciepła
heat transfer
optimization
power plant
thermal stresses
Opis:
Secure and cost-effective power generation has become very important nowdays. Care must be taken while designing and operating modern steam power plants. There are regulations such as German boiler regulations (Technische Regeln fur Dampfkessel 301) or European Standards that guide the user how to operate the steam power plants. However, those regulations are based on the quasi-steady state assumption and one dimensional temperature distribution in the entire element. This simplifications may not guarantee that the heating and cooling operations are conducted in the most efficient way. Thus, it was important to find an improved method that can allow to establish optimum parameters for heating and cooling operations. The optimum parameters should guarantee that the maximum total stresses in the construction element are in the allowable limits and the entire process is conducted in the shortest time. This paper summarizes mathematical descriptions how to optimize shut down process of power block devices. The optimization formulation is based on the assumption that the maximum total stresses in the whole construction element should be kept within allowable limits during cooling operation. Additionally, the operation should be processed in the shortest time possible.
Źródło:
Archives of Thermodynamics; 2011, 32, 4; 91-99
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiz poroga ekonomiceskoj celesoobraznosti ekspluatacii TES i puti ich vozmoznoj modernizacii na primere vnedrenia castotnych preobrazovatelej dla pitatel’nych elektronasosov
Analysis of an economic feasibility threshold of TPP and ways of possible modernization of TPP on the example of the introduction of frequency converters for feeding pumps
Autorzy:
Pogosov, A.
Prijmak, A.
Malkin, E.
Kulinko, E.
Powiązania:
https://bibliotekanauki.pl/articles/2065364.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
pompy zasilające
turbiny parowe
regulacja częstotliwości
moc termiczna
thermal power plant
steam turbine
feeding pump
frequency regulation
Opis:
V stat’e privedeny rezul’taty analiza poroga ekonomiceskoj celesoobraznosti ekspluatacii teplovych elektrostancij, kotoryj pozvolaet opredelit’ ekonomiceski obosnovannye sroki podlenia raboty TES, a takze pokazyvaet rentabel’nyj uroven’ zatrat topliva na vyrabotku elektriceskoj energii. Vo vtoroj casti stat’i privedeny techniko-ekonomiceskie pokazateli vnedrenia castotnych preobrazovatelej dla pitatel’nych elektronasosov, kak odin iz celesoobraznych sposobov modernizacii TES.
This article presents the results of the economic feasibility analysis of the threshold operation of thermal power plants (TPP). The determination of an economic feasibility threshold makes it possible to estimate an economically reasonable extension of TPP lifetime and shows reasonable fuel cost level for electricity generation. The second part of the article shows the technical and economic performance of an introduction of frequency converters for feeding pump as one of the appropriate methods of modernization of TPP.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 2 (16); 63--69
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The demand analysis of the biogas plant with chp system on substrate, the aim to obtain required electrical and thermal power
Autorzy:
Piętak, A.
Meus, M.
Nitkiewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/246798.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
biogas
biogas plant
cogeneration
electrical power
renewable energy
thermal power
transportation
Opis:
Due to the ending resources of fossil fuels, as well as instability of the political situation on the world, especially in countries that are their main supplier, governments of poor countries in resources are forced to seek alternative sources of energy. Currently the most commonly used raw material to produce an electrical and thermal power in Poland are coal and lignite, However, in a result of an increase of their prices and an exacerbated by the EU of regulations about an emission of the greenhouse gas, emerged trends, that aim to transform the energy sector through the implementation of technologies based on alternative energy sources. The main focus is to put on renewable energy sources. The methodology, which is contained in this paper, presents a way to designation the demand of the biogas plant with CHP system on substrate of agricultural origin, the aim to obtain required electrical and thermal power. Moreover, the paper presents a simplified diagram of anaerobic fermentation, which is the basis of biogas production, as well as an illustrative diagram of a biogas plant with CHP system. In this paper also was mentioned the possibility of application biogas for transportation purposes.
Źródło:
Journal of KONES; 2012, 19, 3; 334-344
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Siłownia parowa z wieloźródłowym zasilaniem
Vapour power plant utilizing multiple energy sources
Autorzy:
Nowak, W.
Wiśniewski, S.
Borsukiewicz-Gozdur, A.
Powiązania:
https://bibliotekanauki.pl/articles/173152.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
siłownia parowa
siłownia ORC jednobiegowa
siłownia binarna
obliczenia cieplno-przepływowe
vapour power plant
single cycle ORC power plant
binary power plant
thermal and flow calculations
Opis:
W pracy przedstawiono wyniki obliczeń umożliwiające ocenę efektywności pracy siłowni parowej obejmującej jednoobiegową siłownię ORC (organic Rankine cycle) z parowaczem o cyrkulacji wewnętrznej, sprzężonej cieplnie z dolnym obiegiem siłowni binarnej. Rozpatrywane zagadnienie dotyczy wykorzystania dwóch różnotemperaturowych źródeł ciepła do zasilania obiegów organicznych analizowanego układu. Nośnikami energii pomiędzy źródłami ciepła a obiegiem jednoobiegowej siłowni ORC oraz dolnym obiegiem siłowni binarnej są odpowiednie strumienie wody. Omówione rozwiązanie polegające na zastosowaniu w jednoobiegowej siłowni ORC parowacza z cyrkulacją wewnętrzną nośnika energii, który umożliwia dostosowanie temperatury strumienia wody opuszczającej parowacz do wartości odpowiadającej temperaturze strumienia wody zasilającej podgrzewacz dolnego obiegu siłowni binarnej. W związku z tym możliwe jest skierowanie części strumienia wody zasilającej siłownię jednoobiegową do podgrzewacza dolnego obiegu siłowni binarnej. Podano przykłady obliczeniowe potwierdzające korzyści płynące z takiego rozwiązania.
In the paper, calculation results are presented to enable an assessment of the effectiveness of the vapour power plant that consists of the single cycle ORC power plant incorporating the evaporator with internal circulation and of the bottoming binary power plant, whereby the latter two power plants are thermally coupled, but are driven by two heat sources with different temperatures. Water is used as heat carrier from both the heat sources. The ORC power plant solution with the evaporator, that works with the internal circulation is presented in detail. Evaporator of this type enables to adjusted its outlet water temperature to the value of the temperature of the heat carrier delivered to the bottoming binary power plant, whereby part of the evaporator outlet water can be supplied to the preheater of that plant. Advantages of the above solution are confirmed by the results of the calculated exemplary cases.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 103-112
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and economic study of the energy transition from natural gas to green hydrogen in thermal power plants
Autorzy:
Moulebe, Laince Pierre
Touati, Abdelwahed
Obar, Akpoviroro Eric
Belbsir, Oumayma
Rabbah, Nabila
Powiązania:
https://bibliotekanauki.pl/articles/27323589.pdf
Data publikacji:
2023
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
green hydrogen
thermal power plant
combustion
zielony wodór
elektrociepłownia
spalanie
Opis:
This research article contributes to the challenge of global warming by presenting the approach of the use of green hydrogen to reduce greenhouse gases. It shows that CO2 emissions can be significantly reduced in thermal power plants by replacing natural gas with green hydrogen as a fuel. This work presents the techno-economic study of the energy transition of a 12 MW thermal power plant based on green hydrogen. The presented study is based on the energy consumption of Nigeria, 73% of which is covered by natural gas thermal power plants. The obtained results show that the cost of this transition is ca. 17 million dollars (USD) for a reduction of 114 tCO2 per plant with a return on investment between 4-5 years. In addition, through modeling and numerical simulation, this article shows that estimated return on investment can be shortened by using the thermal power resulting from the turbine, through industrial use.
Źródło:
Acta Innovations; 2023, 49; 49--59
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ceramics Materials with Addition of Ashes from Combustion of Coal in Thermal Power Plants
Materiały ceramiczne z dodatkiem popiołów ze spalania węgla w elektrowniach termicznych
Autorzy:
Michalikova, F.
Brezani, I.
Sisol, M.
Skvarla, J.
Kozakova, L.
Powiązania:
https://bibliotekanauki.pl/articles/318233.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
ceramics
fly ash
solid wastes
thermal power plant
ceramika
popioły lotne
odpady stałe
elektrownia termiczna
Opis:
This article reviews results of an experimental study aimed to evaluate the possibility of using ashes - solid wastes from combustion of brown coal in fluid and granulation boilers as one of the ingredients in ceramics production. Results of testing of the ashes from different combustion processes – combustion of slovak brown coal in granulation and fluid boilers and their usage as a components in dark ceramics showed partial usability in this field. These test consisted of firing the ashes in electric laboratory oven and in industrial fast firing oven. Sample (83) of brown coal fluid bed ash has low Fe content, material has light brown color at temperatures 1100 – 1190 °C after partial melting. Sample (84) with fluid fly ash has higher Fe content, resulting in dark brown color. Both of the samples from fluid combustion of coal require higher temperature for partial melting than 1190 °C. Sample (85) of stabilizate – product of desulphurization – was at the same temperature of 1100 °C completely molten. Sample (86) of granulation ash at the same temperature conditions expanded during firing. Results of this testing practice have proven, that tested ashes have high content of coloring oxides, mainly iron oxide, which results in red up to brown color of the ceramic material. Because of high CaO content in fluid ashes they can only be used as an additive of porous ceramic materials. Use of the tested ashes in compounds prepared using similar procedures as the industrial compounds resulted in higher suction capacity. Our tests have proven the possibility of using fluid bed ash as an opening material, fly ash as a partial replacement of opening material and melting ingredient, desulphurization product as a partial replacement of melting ingredient. Laboratory tests confirmed usability of granulation ashes as an ingredient in dark colored tile manufacture.
W artykule dokonano przeglądu wyników badania eksperymentalnego, mającego na celu ocenę możliwości wykorzystania popiołów - odpadów stałych ze spalania węgla brunatnego, w kotłach fluidalnych i granulacyjnych jako jednego ze składników w produkcji wyrobów ceramicznych. Wyniki badań popiołów z różnych procesów spalania - spalanie słowackiego węgla brunatnego w kotłach granulacyjnych i fluidalnych, oraz ich użycie jako składników w ciemnych wyrobach ceramicznych, wykazały częściową użyteczność w tej dziedzinie. Test składał się z wypalania popiołów w elektrycznym piecu laboratoryjnym oraz w przemysłowym piecu do szybkiego wypalania. Próbki (83) popiołów z węgla brunatnego ze złoża fluidalnego mają niską zawartość Fe, materiał ma jasnobrązowy kolor w temperaturze 1100 - 1190°C po częściowym stopieniu. Próbki (84) popiołu lotnego ze złoża fluidalnego mają wyższą zawartość Fe, co w rezultacie daje ciemnobrązowy kolor. Obie grupy próbek z fluidalnego spalania węgla wymagają do ich częściowego stopienia temperatury wyższej niż 1190°C. Próbki (85) ze stabilizatu - produktu odsiarczania - były w temperaturze 1100°C całkowicie stopione. Próbki (86) popiołu z granulacji w tych samych warunkach temperaturowych, rozszerzyły się w czasie wypalania. Wyniki tego badania wykazały że, w praktyce, badane popioły maja wysoką zawartość tlenków barwiących, głównie tlenku żelaza, co prowadzi do uzyskania czerwono-brązowego koloru materiału ceramicznego. Ze względu na wysoką zawartość CaO w popiele ze złoża fluidalnego, mogą być one używane tylko jako dodatku do porowatych materiałów ceramicznych. Wykorzystanie badanych popiołów w związkach przygotowanych przy użyciu podobnych procedur jak w przypadku związków przemysłowych spowodowało wzrost zdolności zasysania. Testy wykazały możliwość wykorzystania popiołu ze złoża fluidalnym jako materiału otwierającego, popiołu lotnego jako częściowo zastępującego materiał otwierający i topliwy, produkt odsiarczania jako częściowe zastąpienie substancji topliwej. Badania laboratoryjne potwierdziły przydatność popiołów granulacyjnych jako składnika w produkcji płytek o ciemnym kolorze.
Źródło:
Inżynieria Mineralna; 2014, R. 15, nr 2, 2; 15-22
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of the Triad Approach to Ecological Assessment of the State of a Reservoir Receiving Wastewater From a Thermal Power Plant
Autorzy:
Mahanova, Elena
Powiązania:
https://bibliotekanauki.pl/articles/1839092.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
thermal power plant
chemical analysis of water
bioassay
bioindication
pollution
trophicity
Opis:
Thermal power plants (TPP) belong to the enterprises that accompany the development of any city. These industrial facilities consume and discharge large amounts of water. Therefore, thermal power plants are often located near water bodies that need to assess their ecological state and predict the consequences of the anthropogenic impact. The purpose of the work was to assess the ecological state of the floodplain Lake Ivanovskoye (Russia, Kirov region), which receives the wastewater from a thermal power plant, using a triadic approach and comparing the results of chemical analysis, bioassay and bioindication. It was shown that the main pollutant in the lake and the canal connecting Lake Ivanovskoye with the nearest river Vyatka is ammonium ion (up to 3.2 mg/dm3). In addition, the Russian standards for biological oxygen consumption are exceeded (analysis period is 20 days). The tests for the toxicity of wastewater showed inhibition of Paramecium caudatum and Escherichia coli reactions. In contrast, natural surface water from Lake Ivanovskoye stimulated the test functions of Scenedesmus quadricauda, P. caudatum, and E. coli. The death of Daphnia magna in the samples were not recorded. The totality of the facts pointed to the organic nature of pollution, leading to the anthropogenic eutrophication of the lake. The hypothesis was tested by using the bioindication method and by analyzing the totality of species of coastal aquatic plants. It was shown that the reservoir belongs to the mesotrophic type with a moderate degree of pollution, which decreases with distance from the wastewater discharge points. The increase in the trophicity of the reservoir is facilitated by thermal pollution (up to +15℃) and an alkaline pH of wastewater (up to 9.2). Thus, the joint analysis of the results of chemical analysis, bioassay and bioindication made it possible to carry out an objective assessment of the ecological state of the reservoir and identify the reasons for the revealed facts.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 155-160
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining steam condensation pressure in a power plant condenser in off-design conditions
Autorzy:
Laskowski, Rafał
Smyk, Adam
Ruciński, Adam
Szymczyk, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1954999.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal power plant
steam condenser
condenser model
steam condensation
pressure
reference parameters
steam condenser effectiveness
Opis:
The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrownia siersza wodna (1913-1962)
Siersza Wodna Power Plant (1913-1962)
Autorzy:
Kwiatkowski, Marian
Powiązania:
https://bibliotekanauki.pl/articles/1199204.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
Siersza
Historia elektrowni
Elektrownia cieplna
Elektrownia okręgowa
History of power plant
Thermal power plant
District power plant
Opis:
Thermal power plant Siersza Wodna, put into operation in 1913, was the first district power plant in Galicia. Its main task was generation of electrical energy and its distribution to end clients. That feature differentiated Siersza Wodna from other company power plants the main task of which was to generate electricity for the company; distribution to external users was a secondary task. The plant was financed from Polish and Austrian resources and soon became the drive for the growth of western Lesser Poland. Its location, close to Galicia Mining company in Siersza, enabled combustion of coal dust and sludge which were difficult to sell. The plant’s initial capacity amounted to 2 x 2.5 MW. Later the capacity increased to 22.5 MW as the plant obtained more government permits and the electrification of the area advanced. At the beginning of 1920s, the plant was purchased by Siła i Światło (Power and Light Company). As part of the company, Siersza Wodna, among other power plants, was to constitute Krakow Electrification District. The outbreak of WWII thwarted these plans. After the war the company took active part in electrification of Krakow voivodship, nonetheless the wear and tear as well as the war damage prevented longer operation of the plant. It was shut down in 1962. An energy utility operates on the premises of former Siersza Wodna. Employess commenced work in the newly-constructed Siersza Power Plant. Siersza Wodna Power Plant significantly contributed to the electrification of western Little Poland as well as education of a large number of power engineers in the region.
Elektrownia cieplna Siersza Wodna uruchomiona w 1913 roku była pierwszą elektrownią okręgową Galicji. Jej głównym zadaniem była produkcja energii elektrycznej i zasilanie nią chętnych odbiorców. To właśnie różniło ją od elektrowni przyzakładowych, dla których głównym celem było zasilanie macierzystego zakładu, a dopiero później, w miarę posiadanych mocy, zasilanie innych odbiorców. Zbudowana przy udziale kapitału polskiego i austriackiego, została motorem rozwoju zachodniej Małopolski. Jej usytuowanie w bezpośrednim sąsiedztwie kopalni węgla „Galicyjskich Akcyjnych Zakładów Górniczych w Sierszy” pozwalało na spalanie miałów i mułów, na które kopalnia nie miała zbytu. Jej początkowa moc wynosiła 2 x 2,5 MW i przez lata w miarę uzyskiwania uprawnień rządowych, zwiększania terenu elektryfikowanego, wzrosła do 22,5 MW. Z początkiem lat 20. ubiegłego wieku została zakupiona przez koncern „Siła i Światło”. W ramach tej spółki miała być jedną z elektrowni tworzących Krakowski Okręg Elektryfikacyjny. Wybuch II wojny światowej pokrzyżował te plany. Po odzyskaniu niepodległości aktywnie uczestniczyła w elektryfikacji województwa krakowskiego. Zużycie wojenne i stan techniczny nie pozwolił jej na dłuższą pracę. Wyłączona została w 1962 roku. Na jej terenie funkcjonuje obecnie zakład energetyczny. Kadra elektrowni przeszła do budowanej wówczas Elektrowni Siersza. Elektrownia Siersza Wodna wniosła olbrzymi wkład w elektryfikację Małopolski Zachodniej i w utworzenie kadry energetyków tego regionu.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 4, 116; 151-157
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrownia Jaworzno I (1898-1998)
Jaworzno I power plant (1898-1998)
Autorzy:
Kwiatkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1197546.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
Elektrownia Jaworzno I
Historia elektrowni
Elektrownia cieplna
Elektrownia kopalniana
Jaworznickie Komunalne Kopalnie Węgla
Jaworzno I Power Plant
History of Power Plant
Thermal Power Plant
Coal mine-owned Power
Plant Jaworzno Municipal Coal Mines
Opis:
Power plant, commissioned in 1898 for the needs of Jaworzno hard-coal mines, was one of the first power plants operating in the former Galicia. Due to the characteristics of Jaworzno coal beds, the power plant was mainly used for the water removal in the mines. Poland’s restored independence encouraged local authorities to buy the coal mine from the Austrians and set up a company called Jaworzno Municipal Coal Mines Ltd. in Krakow. The power plant gradually enlarged its area of electrical energy supply. The breakthrough moment was the order of 6 MW from the Municipality of Krakow. 60 kV distribution line was constructed for this purpose to connect Jaworzno and Krakow power plants. During the WWII, the Nazi occupants commenced further development of the power plant. The end of WWII marked the initiated construction of reinforced concrete boiler support structure. The entire modernization was completed in 1959 with the total installed capacity amounting to 158 MW. Further works were carried out so as to improve the electrical energy generation efficiency. Development of the city of Jaworzno impacted on the power plant’s restructuration into combined heat and power plant. The CHP-plant was permanently shut down after 100 years of operation.
Elektrownia uruchomiona w 1898 roku na potrzeby jaworznickich kopalń węgla kamiennego, była jedną z pierwszych elektrowni Galicji. Z racji właściwości złóż węgla jaworznickiego, służyła głównie do odwadniania kopalń. Już w 1910 roku uruchomiono tam pierwszy turbozespół. Mechanizacja robót górniczych zwiększała ilość posiadanych turbozespołów. Odzyskanie przez Polskę niepodległości zachęciło lokalne władze do wykupienia z rąk austriackich kopalni i utworzenia spółki: „Jaworznickie Komunalne Kopalnie Węgla SA w Krakowie”, właścicielami jej były miasta Kraków i Lwów oraz konsorcjum polskich banków. Elektrownia kopalniana stopniowo rozszerzała obszar swego zasilania. Momentem znacząco wpływającym na rozwój elektrowni było zamówienie przez Kraków 6 MW mocy. Do jej przesyłu wybudowano linię 60 kV łączącą elektrownię jaworznicką z elektrownią krakowską i rozbudowano elektrownię. W czasie II wojny światowej okupanci rozpoczęli kolejną rozbudowę elektrowni. Wyzwolenie zastało rozpoczętą żelbetową konstrukcję nośną kotła. Kontynuowano rozbudowę elektrowni. Oparto ją na dostawach zagranicznych urządzeń. Dopiero w 1952 roku uruchomiono pierwszą turbinę. Rozbudowę zakończono w 1959 roku uzyskując prawie 158 MW mocy. Dalsze modernizacje były prowadzone w celu poprawy sprawności wytwarzania energii. Rozwój Jaworzna wymusił przekształcenie elektrowni w elektrociepłownię. Po 100 latach istnienia została wyłączona.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 4, 120; 217-224
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of optimisation methods applied to thermal cycle of a coal fired power plant
Autorzy:
Kowalczyk, Ł.
Elsner, W.
Powiązania:
https://bibliotekanauki.pl/articles/240829.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermodynamic optimisation
Nelder-Mead method
thermal cycle
coal fired power plant
IPSEpro
optymalizacja termodynamiczna
metoda Neldera-Meada
cykl termiczny
elektrownia węglowa
Opis:
The paper presents a thermodynamic optimization of 900 MW power unit for ultra-supercritical parameters, modified according to AD700 concept. The aim of the study was to verify two optimisation methods, i.e., the finding the minimum of a constrained nonlinear multivariable function (fmincon) and the Nelder-Mead method with their own constrain functions. The analysis was carried out using IPSEpro software combined with MAT-LAB, where gross power generation efficiency was chosen as the objective function. In comparison with the Nelder-Mead method it was shown that using fmincon function gives reasonable results and a significant reduction of computational time. Unfortunately, with the increased number of decision parameters, the benefit measured by the increase in efficiency is becoming smaller. An important drawback of fmincon method is also a lack of repeatability by using different starting points. The obtained results led to the conclusion, that the Nelder-Mead method is a better tool for optimisation of thermal cycles with a high degree of complexity like the coal-fired power unit.
Źródło:
Archives of Thermodynamics; 2013, 34, 4; 175-186
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studying the Efficiency of Treatment Model Mixtures of Petroleum Products with the Modified Sorbent Made of Ash-and-Slag During Dynamic Sorption
Autorzy:
Korotkova, Tatyana Germanovna
Bushumov, Svyatoslav Andreevich
Ksandopulo, Svetlana Yurevna
Solonnikova, Nataliya Vladimirovna
Powiązania:
https://bibliotekanauki.pl/articles/123373.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ash and slag
thermal power plant
sorbent
sorption dynamics
efficiency
petroleum products
extraction
Opis:
Experimental studies on the dynamic sorption of model mixtures containing petroleum products were performed. The subject of the study was the modified sorbent from the ash-and-slag wastes accumulated in the ash dump of the Novocherkassk State District Power Plant (SDPP) (Russia, Novocherkassk, Rostov Region), obtained using the method of ash removal. The quantity of the sorbent for each model solution was fixed at 5.0 g. The model solutions in the amount of 1 dm3 were passed through a column filled with the modified sorbent at constant filtration rate w = const with filtrate takeout of 0.1 dm3/min. The pH value of the solution, which is advisable for extracting petroleum products, was determined experimentally. For this purpose, the model solutions, containing 100 mg/dm3 of petroleum products with pH = 1.65, 4.01, 6.86, 8.12, 9.18, and 11.34, were prepared. The optimum pH value of the solution was considered pH = 7.5. The content of petroleum products in the filtrate in all experiments was determined using IR spectrometry. The working range of water pollution with petroleum products was determined on a series of model solutions containing petroleum products in the range between 0.5 and 10 mg/dm3 with the increment of 0.5, between 10 and 100 mg/dm3 with the increment of 10, and between 100 and 1,000 mg/dm3 with the increment of 100. The maximum extraction of petroleum products from the solution was 88.23%. The applicability of the Henry’s law to the range of petroleum products concentrations in the filtrate of 50 mg/dm3 was confirmed. The adsorption equilibrium constant (Henry’s law constant) was determined experimentally. The effect of the natural freshwater matrix on the degree of petroleum products extraction was studied; no significant effect on petroleum products sorption was found. A conclusion was made that the sorbent can ensure the efficiency of water purifying from petroleum products of no less than 85% in the range of pollution between 5 and 300 mg/dm3.
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 202-209
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recurrent Neural Networks for Predictive Maintenance of Mill Fan Systems
Autorzy:
Koprinkova-Hristova, P. D.
Hadjiski, M. B.
Doukovska, L. A.
Beloreshki, S. V.
Powiązania:
https://bibliotekanauki.pl/articles/226304.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
technical diagnosis
Thermal Power Plant (TPP)
Recurrent Neural Networks (RNN)
distributed control system (DCS)
predictive maintenance
Opis:
In the present paper we focus on online monitoring system for predictive maintenance based on sensor automated inputs. Our subject was a device from Maritsa East 2 power plant - a mill fan. The main sensor information we have access to is based on the vibration of the nearest to the mill rotor bearing block. Our aim was to create a (nonlinear) model able to predict on time possible changes in vibrations tendencies that can be early signal for system work deterioration. For that purpose, we compared two types of recurrent neural networks: historical Elman architecture and a recently developed kind of RNN named Echo stet networks (ESN). The preliminary investigations showed better approximation and faster training abilities of ESN in comparison to the Elman network. Direction of future work will be increasing of predications time horizon and inclusion of our predictor at lower level of a complex predictive maintenance system.
Źródło:
International Journal of Electronics and Telecommunications; 2011, 57, 3; 401-406
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ispolzovanie teplovyh metodov v diagnostike ènergetičeskogo oborudovania rybolovnyh sudov
The using of thermal method in diagnostic of marine plant operation of fishing fleet vessel
Autorzy:
Klyus, O.
Behrendt, C.
Rajewski, P.
Szczepanek, M.
Bezyukov, O.
Kordakov, A.
Powiązania:
https://bibliotekanauki.pl/articles/359249.pdf
Data publikacji:
2013
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
diagnostic
thermal method
maritime power plant operation
Opis:
The article presented non destruction method and results of using thermal method in diagnostic of marine plant operation of fishing fleet vessel.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2013, 35 (107); 76-85
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies