Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal control" wg kryterium: Temat


Tytuł:
Optimization problems for structural acoustic models with thermoelasticity and smart materials
Autorzy:
Lasiecka, Irena
Powiązania:
https://bibliotekanauki.pl/articles/729240.pdf
Data publikacji:
2000
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
structural acoustic model with thermal effects
optimal control problem
smart controls
nonstandard Riccati equations
analyticity of semigroups
Opis:
Optimization problem for a structural acoustic model with controls governed by unbounded operators on the state space is considered. This type of controls arises naturally in the context of "smart material technology". The main result of the paper provides an optimal synthesis and solvability of associated nonstandard Riccati equations. It is shown that in spite of the unboundedness of control operators, the resulting gain operators (feedbacks) are bounded on the state space. This allows to provide full solvability of the associated Riccati equations. The proof of the main result is based on exploiting propagation of analyticity from the structural component of the model into an acoustic medium.
Źródło:
Discussiones Mathematicae, Differential Inclusions, Control and Optimization; 2000, 20, 1; 113-140
1509-9407
Pojawia się w:
Discussiones Mathematicae, Differential Inclusions, Control and Optimization
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Działanie podzespołów sterujących układów hydraulicznych w niskich temperaturach otoczenia w warunkach zasilania gorącym czynnikiem roboczym
Performance of hydraulic control systems fed with hot working fluid in low ambient temperatures
Autorzy:
Jasiński, R.
Powiązania:
https://bibliotekanauki.pl/articles/328794.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
napędy hydrostatyczne
elementy sterujące
procesy cieplne
hydrostatic drive
control
thermal processes
Opis:
Podczas eksploatacji układów hydraulicznych w niskich temperaturach otoczenia powstaje cały szereg trudności ich prawidłowego działania. Może wystąpić między innymi przypadek rozruchu wychłodzonych podzespołów sterujących i wykonawczych zasilanych olejem (nawet gorącym) o temperaturze przewyższającej temperaturę podzespołu. Nagły dopływ gorącego oleju do oziębionego podzespołu hydraulicznego (np. rozdzielacza czy silnika) powoduje tzw. "szok termiczny", któremu towarzyszy niejednakowe nagrzewanie się elementów tego podzespołu w czasie, wskutek różnych cech konstrukcyjnych i własności materiałowych. Przebieg temperatury poszczególnych elementów podzespołu hydraulicznego wywołany warunkami szoku termicznego jest różny. Powoduje to różną w czasie rozszerzalność cieplną elementu podzespołu wpływając na wielkość luzów w procesie przejściowym i może wywołać nieprawidłową pracę całego układu hydraulicznego.
Many problems may be encountered when hydraulic systems are operated in low ambient temperatures. Among them there may be a case of starting-up frozen controls and actuators supplied with oil of temperature higher (even hot) than the temperature of a hydraulic element. An abrupt flow of the hot oil into the frozen hydraulic element (eg directional valve or motor) causes so called "thermal shock", which is accompanied by a non-uniform heating of the element's parts caused by different material and structure properties. The thermal shock causes different temperature responses in particular parts of a hydraulic element. Different thermal expansion of those parts influences height of clearances during this transient process and may jeopardize the performance of the whole hydraulic system.
Źródło:
Diagnostyka; 2004, 30, T. 1; 211-216
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zdatności hydraulicznych zespołów sterujących uruchamianych w niskich temperaturach otoczenia
Evaluation of ability of hydraulic control components to start up in low ambient temperatures
Autorzy:
Jasiński, R.
Powiązania:
https://bibliotekanauki.pl/articles/327754.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
napęd hydrostatyczny
element sterujący
proces cieplny
hydrostatic drive
control
thermal process
Opis:
Producenci maszyn i urządzeń z napędem hydraulicznym chcą mieć pewność, że ich wyroby będą prawidłowo działały w różnych warunkach atmosferycznych. Metoda opracowana przez autora, dzięki której można określić zdatność zespołów hydraulicznych, w tym sterujących, uruchamianych w niskich temperaturach otoczenia, może być w tym pomocna. W laboratorium Katedry Hydrauliki i Pneumatyki Politechniki Gdańskiej przebadano w niskich temperaturach otoczenia (w warunkach szoku termicznego - zasilanie oziębionych zespołów hydraulicznych gorącym czynnikiem roboczym) wybrane zespoły sterujące układów hydraulicznych: zawór przelewowy UZPP16 firmy PONAR WADOWICE, rozdzielacze 4WEH16C33/6AW220-50 firmy REXROTH i RE2510/101 firmy HYDROTOR, rozdzielacz proporcjonalny PVG 32 firmy SAUER DANFOSS, serwozawór 4WS2EM10 - 45/20B2T315Z8EM firmy REXROTH. Wyznaczono współczynniki przejmowana ciepła od oleju do elementów hydraulicznych zespołów sterujących, które umożliwiają skorzystanie z metody symulacji komputerowej lub analitycznej wyznaczenia efektywnego luzu określającego prawidłową lub nieprawidłową pracę. Zostały wyznaczone obszary prawidłowej i nieprawidłowej pracy zaworów w zależności od natężenia przepływu oraz różnicy temperatur pomiędzy gorącym olejem i oziębionym rozdzielaczem.
The manufacturers of machines and devices of hydraulic drive want to have certainty that their articles will operate in different weather conditions. The worked out by R. Jasiński method has been helpful to qualify the evaluation of ability of hydraulic components, also controls to start up in low ambient temperatures. In laboratory of Department of Hydraulics and Pneumatics of Gdańsk University of Technology the chosen control hydraulic components systems have been tested in low ambient temperatures (thermal shock conditions). They were following components: electrically controlled directional spool valve RE2510 produced by HYDROTOR, electro-hydraulically controlled directional spool valve 4WEH16C33/6AW220-50 produced by REXROTH, proportional valve type PVG 32 produced by SAUER DANFOSS, pressure relief valve UZPP16 produced by PONAR WADOWICE, servo valve 4WS2EM10 - 45/20 B2T315Z8EM produced by REXROTH. The database, containing values of heat transfer coefficients, between oil and swilled element, dependent on oil velocity, for various hydraulic components, was created. On the basis of the data, it is possible to determine, by computer simulation or analytic method, the range of parameters (oil flow rate and temperature difference between oil and hydraulic component temperatures) for correct operation of hydraulic components (systems) in thermal shock conditions. The methods of analytic and computer simulation for determining the area of correct operation of the hydraulic component (system) in thermal shock conditions, might be very useful for designers to construct hydraulic components and systems for machines that work in low ambient temperatures.
Źródło:
Diagnostyka; 2008, 2(46); 189-194
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determinants of thermal insulating properties of walls using thermographic method
Uwarunkowania wyznaczania izolacyjności cieplnej przegród budowlanych metodą termograficzną
Autorzy:
Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/386102.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
izolacyjność cieplna
kamera termograficzna
warunki kontroli termograficznej
thermal insulation
thermographic camera
thermographic control conditions
Opis:
Heat transmission coefficient U is a measure of thermal insulating properties of walls. Its value should be determined in a stable state of heat exchange. During the in situ measurements the temperature of wall surface and heat flux density are measured with the use of a heat flow meter. These are single-point measurements and thus they do not provide a complete view of a thermal insulation of the surface. Thermographic measurement allows to achieve a surface temperature distribution. It lasts too short to conclude on its basis that the state of heat exchange was really stable. Therefore, for quantitative thermographic measurements, it is important to identify the exact conditions of heat exchange and to carefully select the time of conducting imaging procedure.
Współczynnik przenikania ciepła U jest miarą izolacyjności cieplnej przegród budowlanych. Jego wartość powinna być wyznaczana w ustalonym stanie wymiany ciepła. W warunkach in situ przeprowadza się pomiary temperatury powierzchni przegrody i gęstości strumienia ciepła z wykorzystaniem ciepłomierza. Są to pomiary punktowe, które nie dają powierzchniowego obrazu izolacyjności cieplnej. Pomiar termograficzny umożliwia uzyskanie powierzchniowego rozkładu temperatury. Trwa on zbyt krótko, by stwierdzić na jego podstawie, że stan wymiany ciepła naprawdę był ustalony. Dlatego dla ilościowych pomiarów termograficznych ważne jest dokładne rozpoznanie warunków wymiany ciepła i staranny wybór pory wykonania obrazowania.
Źródło:
Geomatics and Environmental Engineering; 2010, 4, 1/1; 163-172
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compensation of machine tool angular thermal errors using controlled internal heat sources
Autorzy:
Mares, M.
Horejs, O.
Hornych, J.
Kohut, P.
Powiązania:
https://bibliotekanauki.pl/articles/971270.pdf
Data publikacji:
2011
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
control
machine tool
angular thermal error
transfer function
Opis:
Thermal errors caused by the influence of internal and external heat sources in machine tool structure can cause up to 70% of total machine tool inaccuracy. Therefore, research on thermal behavior of machine tool structures is crucial for successful manufacturing. This paper provides an insight into the modeling of highly nonlinear (increasing with the complexity of the structure) machine tool thermal behavior using thermal transfer functions This approach to modeling is dynamic (uses thermal history) and, due to its relative simplicity, it enables real-time calculations. The method uses very few additional gauges and solves separately each influence participating in the thermal error. The main objective of the article is to describe the estimation of angular deformations occurring at the tool center point due to thermal influences. Transfer functions are used for the identification and control of additional internal heat sources. The second aim is to compare modeling effort with approximation quality. A partial objective is to cover other nonlinearities occurring generally in machine tool thermal behavior. The approach has been verified on a closed quill (a simple and symmetrical machine tool part) and applied on a model of a machine tool structure which has been chosen as the least favorable from the thermal point of view.
Źródło:
Journal of Machine Engineering; 2011, 11, 4; 78-90
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koordynacja układów regulacji generatorów i transformatorów elektrociepłowni przemysłowej
Autorzy:
Szczerba, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397382.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
układ regulacji
generator
transformator
elektrociepłownia przemysłowa
control system
transformer
thermal power station
Opis:
Generatory elektrociepłowni przemysłowych (zwykle w liczbie kilku) pracują równolegle, przyłączone do szyn zbiorczych 6 kV. Szyny zbiorcze 6 kV są połączone ze stacją 110 kV za pomocą co najmniej dwóch (zwykle kilku) transformatorów 110/6 kV. Układy regulacji generatorów są często nietrafnie nastawiane, a algorytmy działania regulatorów transformatorów 110/6 kV są nieprawidłowe, uniemożliwiając współpracę układów regulacji elektrociepłowni. W artykule podano propozycję koordynacji algorytmów działania układów regulacji.
Źródło:
Acta Energetica; 2011, 1; 51-57
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena cieplno-wilgotnościowa stropodachu szczelinowego nad basenem na przykładzie rozwiązania zrealizowanego w praktyce
Evaluation of the thermal and damp properties of a slotted flat roof over a swimming pool, based on a practical example
Autorzy:
Byrdy, A.
Kisilewicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/163551.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen
stropodach szczelinowy
właściwości cieplno-wilgotnościowe
przykład
swimming pool
slotted flat roof
thermal and moisture control properties
example
Opis:
Hale krytych basenów są obiektami, w których panuje wysoka temperatura i wilgotność względna powietrza wewnętrznego. Takie warunki stawiają wysokie wymagania przy projektowaniu przegród zewnętrznych tego rodzaju obiektów, ze szczególnym uwzględnieniem stropodachów. W artykule przeanalizowano błędy projektowe w przykładowym zrealizowanym stropodachu, który wykazał problemy eksploatacyjne już w pierwszych miesiącach funkcjonowania obiektu.
Indoor swimming pool buildings are subject to high temperatures and relative humidity of the air in their interior. These conditions entail stringent requirements for the design of the external partitions of such buildings, particularly their flat roofs. This article contains an analysis of design errors based on the example of a roof which suffered operational problems only months after the facility was opened.
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 2, 2; 47-53
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recurrent Neural Networks for Predictive Maintenance of Mill Fan Systems
Autorzy:
Koprinkova-Hristova, P. D.
Hadjiski, M. B.
Doukovska, L. A.
Beloreshki, S. V.
Powiązania:
https://bibliotekanauki.pl/articles/226304.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
technical diagnosis
Thermal Power Plant (TPP)
Recurrent Neural Networks (RNN)
distributed control system (DCS)
predictive maintenance
Opis:
In the present paper we focus on online monitoring system for predictive maintenance based on sensor automated inputs. Our subject was a device from Maritsa East 2 power plant - a mill fan. The main sensor information we have access to is based on the vibration of the nearest to the mill rotor bearing block. Our aim was to create a (nonlinear) model able to predict on time possible changes in vibrations tendencies that can be early signal for system work deterioration. For that purpose, we compared two types of recurrent neural networks: historical Elman architecture and a recently developed kind of RNN named Echo stet networks (ESN). The preliminary investigations showed better approximation and faster training abilities of ESN in comparison to the Elman network. Direction of future work will be increasing of predications time horizon and inclusion of our predictor at lower level of a complex predictive maintenance system.
Źródło:
International Journal of Electronics and Telecommunications; 2011, 57, 3; 401-406
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wieloparametryczna ocena warunków komfortu cieplnego
Multiparameter evaluation of thermal comfort conditions
Autorzy:
Plutecki, Z.
Powiązania:
https://bibliotekanauki.pl/articles/151455.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
komfort cieplny
pomiar wielkości fizycznych
optymalizacja układu regulacji systemów ogrzewczych i wentylacyjnych
thermal comfort
measurement of physical quantities
optimisation of control system for heating and ventilation systems
Opis:
W artykule przedstawiono główne zagadnienia związane z badaniem komfortu cieplnego w ogrzewanych pomieszczeniach metodą pomiarową oraz z wykorzystaniem symulacji komputerowych. Przedstawione przykłady badań wskazują na potrzebę uwzględnienia w układzie automatycznej regulacji obiektywnej wielkości. Zdaniem autora parametrem takim może być wyznaczana temperatura odczuwalna.
The paper describes influence of chosen quantities as well as construction and exploitation conditions of a heating system on heat-flow phenomena in a heated room. It is pointed out that the analysis of heat-flow phenomena can be a valuable source of information as regards methods for creating thermal comfort. The examples of investigations performed show the need of including an objective quantity in the automatic control system. The determined sensible temperature can be, according to the author, such a quantity. A mathematical model of the heat -flow phenomena in a heated room has been formulated taking into consideration complex heat exchange and air infiltration from the outdoors. Measurements of thermal comfort conditions have been taken and numerical simulations have been performed when taking into account the influence of variable external conditions, different heating techniques, ways of ventilation system arrangement on three-dimensional temperature profile, air motion velocity and radiation temperature. A test post has been designed and constructed, and a large number of experimental investigations have been conducted, including the one allowing verification of computation results.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 2, 2; 153-156
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of CCHP in deep mine thermal hazard control
Zastosowanie systemu trójgeneracji w systemie kontroli zagrożeń termicznych w kopalni głębinowej
Autorzy:
Yang, D. D.
Wang, B. S.
Zhou, S. G.
Qin, R. X.
Powiązania:
https://bibliotekanauki.pl/articles/348684.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
system trójgeneracji
kopalnia o wysokiej metanowości
kontrola zagrożeń cieplnych
chłodzenie absorpcyjne
CCHP
high gas mine
thermal hazard control
absorption refrigeration
Opis:
Due to the characteristics of high gas, high geothermal temperature and high strength development in Huainan mine area, thermal hazard problem has become more and more serious and also affects safety and productivity in coal mine. The CCHP (combined cooling heating and power), as a new mode to control thermal hazard, is put forward after advantages and disadvantages of all kinds of cooling methods are investigated. The CCHP method not only takes full advantage of gas but also reduces the greenhouse gas emission. At the same time, the application of CCHP remits the pressure of the power supply in summer, providing guarantee for safe and high efficiency exploitation.
W związku z wysoką gazonośnością, wysoką temperaturą pierwotną górotworu i wysokimi wartościami zawartości metanu w kopalni Huainan zaobserwowano zagrożenia natury cieplnej, wpływające również na bezpieczeństwo i wydajność produkcji w kopalni. Po zbadaniu wad i zalet różnych metod klimatyzacji podjęto decyzję o wprowadzeniu systemu trójgeneracji jako nowego sposobu kontroli zagrożeń natury cieplnej. Metoda trójgeneracji nie tylko wykorzystuje pełen potencjał ujętego gazu, ale również pozwala obniżyć emisję gazów cieplarnianych. Zastosowanie tego systemu zmniejsza ponadto pobór energii zasilającej w porze letniej, dając gwarancję bezpiecznej i wydajnej eksploatacji kopalni.
Źródło:
AGH Journal of Mining and Geoengineering; 2012, 36, 3; 443-451
1732-6702
Pojawia się w:
AGH Journal of Mining and Geoengineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of a Simulation Model for Controlling and Improving the Productivity of Batch Reactors
Autorzy:
Henini, G.
Souahi, F.
Laidani, Y.
Powiązania:
https://bibliotekanauki.pl/articles/779240.pdf
Data publikacji:
2013
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
batch chemical reactor
thermal control
dynamic simulator
mono-fluid
heating and cooling system
Opis:
This paper describes the development of a dynamic simulator model for a jacketed batch reactor equipped with a mono-fluid heating/cooling system. The Mono-fluid flows at constant flow-rate through the jacketed reactor. The heating and cooling are assured respectively by electrical resistance and two plate heat exchangers. A detailed description of the equations leading to the development of simulation model is presented. The model is based on writing the equations of the mass balance and the heat balance for the reactor and the thermal loop in unsteady state. To validate the simulation model, we first studied the thermal behavior of the reaction mixture during heating and cooling, using water as the reaction mixture. We then considered the consecutive chemical reaction of the synthesis of cyclopentanediol from cyclopentadiene by studying the yield of this reaction. The results show that heating the reaction mixture increases significantly the yield of this synthesis reaction.
Źródło:
Polish Journal of Chemical Technology; 2013, 15, 1; 78-87
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of engine control on the energetic inter change ability of diesel oil by gas in dual fuel GI engine
Autorzy:
Stelmasiak, Zdzisław
Powiązania:
https://bibliotekanauki.pl/articles/243872.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
dual fuel
engine control
natural gas
pilot dose
gas share
thermal efficiency
Opis:
A compression ignition engine fuelled simultaneously with two fuels: a fuel with low cetane number used as the main fuel, and Diesel oil used to initiation of ignition, is assumed to be called as a dual fuel engine. This system is perfectly suited to adaptation to supply of CNG gas in majority of compression ignition engines. Such adaptations can concern both an older engine equipped with classic injection system, and modern engine with common rail system. In traction engines, interchangeability of liquid fuel by the gas belongs to important issues, what is a condition of profitability of the adaptation and operation of dual fuel engines. In the paper are presented test results of the 1CA90 engine with piston pump to injection of liquid fuel, and a system with mixer to supply of the gas; and the SB3.1 engine equipped with common rail system and injection of the gas in area of the inlet valve. On the base of performed tests one has shown variability of energetic fraction of the CNG gas in total energy supplied to the engine. The tests were performed in complete field of variability of engine parameters, i.e. rotational speed and engine load. Obtained results have shown that in spite of decreasing fraction of the gas at partial loads of medium size traction engines, substantial reduction of operational consumption of the Diesel oil is possible. Due to significant differences in price of the CNG gas and the Diesel oil, it gives considerable savings in operational costs of the engines. It should encourage users of the engines to adaptation of the fuelling to the CNG gas. In the paper is presented a proposal of control system to dual fuel traction engine, from maintaining its performance parameters point of view.
Źródło:
Journal of KONES; 2013, 20, 4; 425-434
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robustness and portability of machine tool thermal error compensation model based on control of participating thermal sources
Autorzy:
Mares, M.
Horejs, O.
Hornych, J.
Smolik, J.
Powiązania:
https://bibliotekanauki.pl/articles/99925.pdf
Data publikacji:
2013
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
control
machine tool
thermal error
transfer function
Opis:
Thermal errors caused by the influence of internal and external heat sources in machine tool structure can cause more than 50% of total machine tool inaccuracy. Therefore, research on thermal behavior of machine tool structures is crucial for successful manufacturing. This paper provides an insight into the modeling of highly nonlinear machine tool thermal errors using thermal transfer functions (TTF). The method is dynamic (uses machine tool thermal history) and its modeling and calculation speed is suitable for real-time applications. The method does not require interventions into the machine tool structure, uses very few additional gauges and solves separately each influence participating on thermal error. The paper focuses on the development of a robust thermal model sensitive to various machine tool thermal behavior nonlinearities with the help of minimum input information. Model was applied on real machine tool (portal milling centre) and was verified within a complicated electro-spindle revolution spectrum. Moreover, the said compensation model was applied on another machine tool to prove its robustness and portability among machines of the same type set and the results of the TTF model were compared with a model obtained via multiple linear regression (MLR) as a case study.
Źródło:
Journal of Machine Engineering; 2013, 13, 1; 24-36
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Genetic algorithm tuned IP controller for Load Frequency Control of interconnected power systems with HVDC links
Autorzy:
Selvakumaran, S.
Rajasekaran, V.
Karthigaivel, R.
Powiązania:
https://bibliotekanauki.pl/articles/140655.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
genetic algorithm
Load Frequency Control
IP controller
AC-DC tie-lines
interconnected thermal non-reheat power systems
Opis:
A new design of decentralized Load Frequency Controller for interconnected thermal non-reheat power systems with AC-DC parallel tie-lines based on Genetic Algorithm (GA) tuned Integral and Proportional (IP) controller is proposed in this paper. A HVDC link is connected in parallel with an existing AC tie-line to stabilize the frequency oscillations of the AC tie-line system. Any optimum controller selected for load frequency control of interconnected power systems should not only stabilize the power system but also reduce the system frequency and tie line power oscillations and settling time of the output responses. In practice Load Frequency Control (LFC) systems use simple Proportional Integral (PI) or Integral (I) controller. The controller parameters are usually tuned based on classical or trial-and-error approaches. But they are incapable of obtaining good dynamic performance for various load change scenarios in multi-area power system. For this reason, in this paper GA tuned IP controller is used. A two area interconnected thermal non-reheat power system is considered to demonstrate the validity of the proposed controller. The simulation results show that the proposed controller provides better dynamic responses with minimal frequency and tie-line power deviations, quick settling time and guarantees closed-loop stability margin.
Źródło:
Archives of Electrical Engineering; 2014, 63, 2; 161-175
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical simulation of the heating process in the domain of tissue insulated by protective clothing
Autorzy:
Ciesielski, M.
Mochnacki, B.
Powiązania:
https://bibliotekanauki.pl/articles/122678.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
bioheat transfer
protective clothing
modeling of thermal processes
control volume method
Voronoi tessellation
przepływ ciepła
odzież ochronna
modelowanie procesów cieplnych
teselacja Voronoia
Opis:
In this paper the 2D heterogeneous tissue domain (forearm cross-section) insulated by a layer of protective clothing is considered. The aim of considerations is to develop an algorithm simulating the tissue heating process resulting from the sudden change of external boundary conditions. Here, the authors exploit a certain version of the control volume method (CVM) using the Voronoi tessellation. The mathematical model of heat exchange in the domain analyzed is formulated in the form of a boundary-initial problem based on the system of partial differential equations (energy equations) supplemented by the adequate boundary and initial conditions. In the final part of the paper, the examples of numerical simulations are shown.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2014, 13, 2; 13-20
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies