Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal control" wg kryterium: Temat


Tytuł:
Development of a Simulation Model for Controlling and Improving the Productivity of Batch Reactors
Autorzy:
Henini, G.
Souahi, F.
Laidani, Y.
Powiązania:
https://bibliotekanauki.pl/articles/779240.pdf
Data publikacji:
2013
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
batch chemical reactor
thermal control
dynamic simulator
mono-fluid
heating and cooling system
Opis:
This paper describes the development of a dynamic simulator model for a jacketed batch reactor equipped with a mono-fluid heating/cooling system. The Mono-fluid flows at constant flow-rate through the jacketed reactor. The heating and cooling are assured respectively by electrical resistance and two plate heat exchangers. A detailed description of the equations leading to the development of simulation model is presented. The model is based on writing the equations of the mass balance and the heat balance for the reactor and the thermal loop in unsteady state. To validate the simulation model, we first studied the thermal behavior of the reaction mixture during heating and cooling, using water as the reaction mixture. We then considered the consecutive chemical reaction of the synthesis of cyclopentanediol from cyclopentadiene by studying the yield of this reaction. The results show that heating the reaction mixture increases significantly the yield of this synthesis reaction.
Źródło:
Polish Journal of Chemical Technology; 2013, 15, 1; 78-87
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected problems of electronic equipment design in rocketry
Wybrane problemy projektowania urządzeń elektronicznych w technice rakietowej
Autorzy:
Szpakowska-Peas, E.
Krawczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/952917.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
electronic equipment in rocketry
rockets
vibration
shocks
thermal control
cosmic radiation
sprzęt elektroniczny rakiet
rakiety
wibracje
wstrząsy
kontrola termiczna
Opis:
The paper introduces selected problems of electronic equipment design in rocketry. It mainly focuses on most common issues of electronic equipment design in rocketry. Some history of electronic equipment designed in the Institute of Aviation is outlined. Subsequently, basic avionics requirements are presented. In the next part of the article inevitable negative phenomena that occur during a short flight of a rocket such as vibrations, shocks, thermal stability or cosmic radiation are presented and discussed. Moreover, a few solutions and precautions for designing electronic equipment are proposed. Additionally, a concept of the on-board computer for the rocket ILR-33 Bursztyn, being which is designed and built in the Institute of Aviation, is presented. The idea of the structure and some components which will create data logger and requirements are outlined.
Artykuł omawia wybrane problemy projektowania urządzeń elektronicznych w technice rakietowej. Przede wszystkim skupi się na najczęstszych problemach podczas projektowania takiego rodzaju sprzętu. Na wstępie przedstawiono trochę historii sprzętu elektronicznego zaprojektowanego w Instytucie Lotnictwa. Następnie są zaprezentowane podstawowe wymagania awioniki. W następnej części artykułu są przedstawione i omówione negatywne zjawiska, które występują podczas krótkiego lotu rakiety, takie jak wstrząsy, uderzenia, stabilność termiczna lub promieniowanie kosmiczne. Ponadto, zaproponowano kilka rozwiązań i przedstawiono środki ostrożności podczas projektowania urządzeń elektronicznych. Dodatkowo w artykule została poruszona kwestia koncepcji komputera pokładowego dla rakiety ILR-33 „Bursztyn", który został zaprojektowany i zbudowany w Instytucie Lotnictwa. Krótko omówiono pomysł struktury i niektórych elementów, które będą tworzyć rejestrator danych według wymagań dotyczących sprzętu.
Źródło:
Prace Instytutu Lotnictwa; 2016, 4 (245); 209-217
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of CCHP in deep mine thermal hazard control
Zastosowanie systemu trójgeneracji w systemie kontroli zagrożeń termicznych w kopalni głębinowej
Autorzy:
Yang, D. D.
Wang, B. S.
Zhou, S. G.
Qin, R. X.
Powiązania:
https://bibliotekanauki.pl/articles/348684.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
system trójgeneracji
kopalnia o wysokiej metanowości
kontrola zagrożeń cieplnych
chłodzenie absorpcyjne
CCHP
high gas mine
thermal hazard control
absorption refrigeration
Opis:
Due to the characteristics of high gas, high geothermal temperature and high strength development in Huainan mine area, thermal hazard problem has become more and more serious and also affects safety and productivity in coal mine. The CCHP (combined cooling heating and power), as a new mode to control thermal hazard, is put forward after advantages and disadvantages of all kinds of cooling methods are investigated. The CCHP method not only takes full advantage of gas but also reduces the greenhouse gas emission. At the same time, the application of CCHP remits the pressure of the power supply in summer, providing guarantee for safe and high efficiency exploitation.
W związku z wysoką gazonośnością, wysoką temperaturą pierwotną górotworu i wysokimi wartościami zawartości metanu w kopalni Huainan zaobserwowano zagrożenia natury cieplnej, wpływające również na bezpieczeństwo i wydajność produkcji w kopalni. Po zbadaniu wad i zalet różnych metod klimatyzacji podjęto decyzję o wprowadzeniu systemu trójgeneracji jako nowego sposobu kontroli zagrożeń natury cieplnej. Metoda trójgeneracji nie tylko wykorzystuje pełen potencjał ujętego gazu, ale również pozwala obniżyć emisję gazów cieplarnianych. Zastosowanie tego systemu zmniejsza ponadto pobór energii zasilającej w porze letniej, dając gwarancję bezpiecznej i wydajnej eksploatacji kopalni.
Źródło:
AGH Journal of Mining and Geoengineering; 2012, 36, 3; 443-451
1732-6702
Pojawia się w:
AGH Journal of Mining and Geoengineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena cieplno-wilgotnościowa stropodachu szczelinowego nad basenem na przykładzie rozwiązania zrealizowanego w praktyce
Evaluation of the thermal and damp properties of a slotted flat roof over a swimming pool, based on a practical example
Autorzy:
Byrdy, A.
Kisilewicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/163551.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen
stropodach szczelinowy
właściwości cieplno-wilgotnościowe
przykład
swimming pool
slotted flat roof
thermal and moisture control properties
example
Opis:
Hale krytych basenów są obiektami, w których panuje wysoka temperatura i wilgotność względna powietrza wewnętrznego. Takie warunki stawiają wysokie wymagania przy projektowaniu przegród zewnętrznych tego rodzaju obiektów, ze szczególnym uwzględnieniem stropodachów. W artykule przeanalizowano błędy projektowe w przykładowym zrealizowanym stropodachu, który wykazał problemy eksploatacyjne już w pierwszych miesiącach funkcjonowania obiektu.
Indoor swimming pool buildings are subject to high temperatures and relative humidity of the air in their interior. These conditions entail stringent requirements for the design of the external partitions of such buildings, particularly their flat roofs. This article contains an analysis of design errors based on the example of a roof which suffered operational problems only months after the facility was opened.
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 2, 2; 47-53
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robustness and portability of machine tool thermal error compensation model based on control of participating thermal sources
Autorzy:
Mares, M.
Horejs, O.
Hornych, J.
Smolik, J.
Powiązania:
https://bibliotekanauki.pl/articles/99925.pdf
Data publikacji:
2013
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
control
machine tool
thermal error
transfer function
Opis:
Thermal errors caused by the influence of internal and external heat sources in machine tool structure can cause more than 50% of total machine tool inaccuracy. Therefore, research on thermal behavior of machine tool structures is crucial for successful manufacturing. This paper provides an insight into the modeling of highly nonlinear machine tool thermal errors using thermal transfer functions (TTF). The method is dynamic (uses machine tool thermal history) and its modeling and calculation speed is suitable for real-time applications. The method does not require interventions into the machine tool structure, uses very few additional gauges and solves separately each influence participating on thermal error. The paper focuses on the development of a robust thermal model sensitive to various machine tool thermal behavior nonlinearities with the help of minimum input information. Model was applied on real machine tool (portal milling centre) and was verified within a complicated electro-spindle revolution spectrum. Moreover, the said compensation model was applied on another machine tool to prove its robustness and portability among machines of the same type set and the results of the TTF model were compared with a model obtained via multiple linear regression (MLR) as a case study.
Źródło:
Journal of Machine Engineering; 2013, 13, 1; 24-36
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compensation of machine tool angular thermal errors using controlled internal heat sources
Autorzy:
Mares, M.
Horejs, O.
Hornych, J.
Kohut, P.
Powiązania:
https://bibliotekanauki.pl/articles/971270.pdf
Data publikacji:
2011
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
control
machine tool
angular thermal error
transfer function
Opis:
Thermal errors caused by the influence of internal and external heat sources in machine tool structure can cause up to 70% of total machine tool inaccuracy. Therefore, research on thermal behavior of machine tool structures is crucial for successful manufacturing. This paper provides an insight into the modeling of highly nonlinear (increasing with the complexity of the structure) machine tool thermal behavior using thermal transfer functions This approach to modeling is dynamic (uses thermal history) and, due to its relative simplicity, it enables real-time calculations. The method uses very few additional gauges and solves separately each influence participating in the thermal error. The main objective of the article is to describe the estimation of angular deformations occurring at the tool center point due to thermal influences. Transfer functions are used for the identification and control of additional internal heat sources. The second aim is to compare modeling effort with approximation quality. A partial objective is to cover other nonlinearities occurring generally in machine tool thermal behavior. The approach has been verified on a closed quill (a simple and symmetrical machine tool part) and applied on a model of a machine tool structure which has been chosen as the least favorable from the thermal point of view.
Źródło:
Journal of Machine Engineering; 2011, 11, 4; 78-90
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer Aided Thermal Processes In Technical Spaces
Autorzy:
Janczarek, M.
Bulyandra, O.
Powiązania:
https://bibliotekanauki.pl/articles/117689.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
heat transfer
thermal technical chambers
physical modeling
control process
Opis:
This paper describes research work on methods concerning heat transfers through walls of thermal technical chambers. The paper presents the mathematical and physical analysis of problems in the field of energy savings and material selection in thermal chambers in controlled gaseous environment. The purpose for the research is to point out areas subjected to the highest energy losses caused by building’s construction and geo-graphical orientation of walls in the aspect of daily atmospheric temperature changes emerging on chamber exterior. Thermal problems were solved using computer aided support. The paper presents exemplary measurement results taken in Lublin region during various periods throughout a year.
Źródło:
Applied Computer Science; 2017, 13, 2; 82-93
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Supervisory optimal control using machine learning for building thermal comfort
Autorzy:
Abdufattokhov, Shokhjakhon
Mahamatov, Nurilla
Ibragimova, Kamila
Gulyamova, Dilfuza
Yuldashev, Dilyorjon
Powiązania:
https://bibliotekanauki.pl/articles/2204083.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
building thermal comfort
Gaussian processes
machine learning
model predictive control
Opis:
For the past few decades, control and building engineering communities have been focusing on thermal comfort as a key factor in designing sustainable building evaluation methods and tools. However, estimating the indoor air temperature of buildings is a complicated task due to the nonlinear and complex building dynamics characterised by the time-varying environment with disturbances. The primary focus of this paper is designing a predictive and probabilistic room temperature model of buildings using Gaussian processes (GPs) and incorporating it into model predictive control (MPC) to minimise energy consumption and provide thermal comfort satisfaction. The full probabilistic capabilities of GPs are exploited from two perspectives: the mean prediction is used for the room temperature model, while the uncertainty is involved in the MPC objective not to lose the desired performance and design a robust controller. We illustrated the potential of the proposed method in a numerical example with simulation results.
Źródło:
Operations Research and Decisions; 2022, 32, 4; 1--15
2081-8858
2391-6060
Pojawia się w:
Operations Research and Decisions
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature variation effect on the active vibration control of smart composite beam
Autorzy:
Salah, Mostefa
Boukhoulda, Farouk B.
Nouari, Mohamed
Bendine, Kouider
Powiązania:
https://bibliotekanauki.pl/articles/1837931.pdf
Data publikacji:
2020
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
piezoelectric
thermal loads
beams
active vibration control
Hamilton’s principle
Opis:
Due to their impressive capacity of sensing and actuating, piezoelectric materials have been widely merged in different industrial fields, especially aeronautic and aerospace area. However, in the aeronautic industry, the structures are operating under critical environ-mental loads such as high and very low temperature, which made the investigation of the effect of thermal forces on the piezoelectric struc-tures indispensable to reach the high functionality and performance. The present paper focuses on the effect of thermal loads on the active vibration control (AVC) of structures like beams. For this purpose, a finite element model of composite beam with fully covered piezoelec-tric sensor and actuator based on the well-known high order shear deformation theory is proposed by taking into account the electrical po-tential field and a linear temperature field. Hamilton’s principle is used to formulate the electro-thermo-mechanical governing equations. The negative velocity feedback controller is implemented to provide the necessary gain for the actuator. Different analyses are effectuated to present the effect of the temperature ranging from -70°C to 70°C on the active vibration control of the composite beam.
Źródło:
Acta Mechanica et Automatica; 2020, 14, 3; 166-174
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved calibration uncertainty assessment technique in coordinate metrology considering thermal influences
Autorzy:
Mussatayev, Meirbek
Huang, Meifa
Nurtas, Marat
Arynov, Azamat
Powiązania:
https://bibliotekanauki.pl/articles/2052177.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
coordinate measuring machine
coordinate metrology
uncertainty
quality control
thermal influence
Opis:
Reliable measurement uncertainty is a crucial part of the conformance/nonconformance decision-making process in the field of Quality Control in Manufacturing. The conventional GUM-method cannot be applied to CMM measurements primarily because of lack of an analytical relationship between the input quantities and the measurement. This paper presents calibration uncertainty analysis in commercial CMM-based Coordinate Metrology. For the case study, the hole-plate calibrated by the PTB is used as a workpiece. The paper focuses on thermo-mechanical errors which immediately affect the dimensional accuracy of manufactured parts of high-precision manufacturers. Our findings have highlighted some practical issues related to the importance of maintaining thermal equilibrium before the measurement. The authors have concluded that the thermal influence as an uncertainty contributor of CMM measurement result dominates the overall budgets for this example. The improved calibration uncertainty assessment technique considering thermal influence is described in detail for the use of a wide range of CMM users.
Źródło:
Metrology and Measurement Systems; 2021, 28, 4; 609--626
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Działanie podzespołów sterujących układów hydraulicznych w niskich temperaturach otoczenia w warunkach zasilania gorącym czynnikiem roboczym
Performance of hydraulic control systems fed with hot working fluid in low ambient temperatures
Autorzy:
Jasiński, R.
Powiązania:
https://bibliotekanauki.pl/articles/328794.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
napędy hydrostatyczne
elementy sterujące
procesy cieplne
hydrostatic drive
control
thermal processes
Opis:
Podczas eksploatacji układów hydraulicznych w niskich temperaturach otoczenia powstaje cały szereg trudności ich prawidłowego działania. Może wystąpić między innymi przypadek rozruchu wychłodzonych podzespołów sterujących i wykonawczych zasilanych olejem (nawet gorącym) o temperaturze przewyższającej temperaturę podzespołu. Nagły dopływ gorącego oleju do oziębionego podzespołu hydraulicznego (np. rozdzielacza czy silnika) powoduje tzw. "szok termiczny", któremu towarzyszy niejednakowe nagrzewanie się elementów tego podzespołu w czasie, wskutek różnych cech konstrukcyjnych i własności materiałowych. Przebieg temperatury poszczególnych elementów podzespołu hydraulicznego wywołany warunkami szoku termicznego jest różny. Powoduje to różną w czasie rozszerzalność cieplną elementu podzespołu wpływając na wielkość luzów w procesie przejściowym i może wywołać nieprawidłową pracę całego układu hydraulicznego.
Many problems may be encountered when hydraulic systems are operated in low ambient temperatures. Among them there may be a case of starting-up frozen controls and actuators supplied with oil of temperature higher (even hot) than the temperature of a hydraulic element. An abrupt flow of the hot oil into the frozen hydraulic element (eg directional valve or motor) causes so called "thermal shock", which is accompanied by a non-uniform heating of the element's parts caused by different material and structure properties. The thermal shock causes different temperature responses in particular parts of a hydraulic element. Different thermal expansion of those parts influences height of clearances during this transient process and may jeopardize the performance of the whole hydraulic system.
Źródło:
Diagnostyka; 2004, 30, T. 1; 211-216
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zdatności hydraulicznych zespołów sterujących uruchamianych w niskich temperaturach otoczenia
Evaluation of ability of hydraulic control components to start up in low ambient temperatures
Autorzy:
Jasiński, R.
Powiązania:
https://bibliotekanauki.pl/articles/327754.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
napęd hydrostatyczny
element sterujący
proces cieplny
hydrostatic drive
control
thermal process
Opis:
Producenci maszyn i urządzeń z napędem hydraulicznym chcą mieć pewność, że ich wyroby będą prawidłowo działały w różnych warunkach atmosferycznych. Metoda opracowana przez autora, dzięki której można określić zdatność zespołów hydraulicznych, w tym sterujących, uruchamianych w niskich temperaturach otoczenia, może być w tym pomocna. W laboratorium Katedry Hydrauliki i Pneumatyki Politechniki Gdańskiej przebadano w niskich temperaturach otoczenia (w warunkach szoku termicznego - zasilanie oziębionych zespołów hydraulicznych gorącym czynnikiem roboczym) wybrane zespoły sterujące układów hydraulicznych: zawór przelewowy UZPP16 firmy PONAR WADOWICE, rozdzielacze 4WEH16C33/6AW220-50 firmy REXROTH i RE2510/101 firmy HYDROTOR, rozdzielacz proporcjonalny PVG 32 firmy SAUER DANFOSS, serwozawór 4WS2EM10 - 45/20B2T315Z8EM firmy REXROTH. Wyznaczono współczynniki przejmowana ciepła od oleju do elementów hydraulicznych zespołów sterujących, które umożliwiają skorzystanie z metody symulacji komputerowej lub analitycznej wyznaczenia efektywnego luzu określającego prawidłową lub nieprawidłową pracę. Zostały wyznaczone obszary prawidłowej i nieprawidłowej pracy zaworów w zależności od natężenia przepływu oraz różnicy temperatur pomiędzy gorącym olejem i oziębionym rozdzielaczem.
The manufacturers of machines and devices of hydraulic drive want to have certainty that their articles will operate in different weather conditions. The worked out by R. Jasiński method has been helpful to qualify the evaluation of ability of hydraulic components, also controls to start up in low ambient temperatures. In laboratory of Department of Hydraulics and Pneumatics of Gdańsk University of Technology the chosen control hydraulic components systems have been tested in low ambient temperatures (thermal shock conditions). They were following components: electrically controlled directional spool valve RE2510 produced by HYDROTOR, electro-hydraulically controlled directional spool valve 4WEH16C33/6AW220-50 produced by REXROTH, proportional valve type PVG 32 produced by SAUER DANFOSS, pressure relief valve UZPP16 produced by PONAR WADOWICE, servo valve 4WS2EM10 - 45/20 B2T315Z8EM produced by REXROTH. The database, containing values of heat transfer coefficients, between oil and swilled element, dependent on oil velocity, for various hydraulic components, was created. On the basis of the data, it is possible to determine, by computer simulation or analytic method, the range of parameters (oil flow rate and temperature difference between oil and hydraulic component temperatures) for correct operation of hydraulic components (systems) in thermal shock conditions. The methods of analytic and computer simulation for determining the area of correct operation of the hydraulic component (system) in thermal shock conditions, might be very useful for designers to construct hydraulic components and systems for machines that work in low ambient temperatures.
Źródło:
Diagnostyka; 2008, 2(46); 189-194
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koordynacja układów regulacji generatorów i transformatorów elektrociepłowni przemysłowej
Autorzy:
Szczerba, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397382.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
układ regulacji
generator
transformator
elektrociepłownia przemysłowa
control system
transformer
thermal power station
Opis:
Generatory elektrociepłowni przemysłowych (zwykle w liczbie kilku) pracują równolegle, przyłączone do szyn zbiorczych 6 kV. Szyny zbiorcze 6 kV są połączone ze stacją 110 kV za pomocą co najmniej dwóch (zwykle kilku) transformatorów 110/6 kV. Układy regulacji generatorów są często nietrafnie nastawiane, a algorytmy działania regulatorów transformatorów 110/6 kV są nieprawidłowe, uniemożliwiając współpracę układów regulacji elektrociepłowni. W artykule podano propozycję koordynacji algorytmów działania układów regulacji.
Źródło:
Acta Energetica; 2011, 1; 51-57
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of engine control on the energetic inter change ability of diesel oil by gas in dual fuel GI engine
Autorzy:
Stelmasiak, Zdzisław
Powiązania:
https://bibliotekanauki.pl/articles/243872.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
dual fuel
engine control
natural gas
pilot dose
gas share
thermal efficiency
Opis:
A compression ignition engine fuelled simultaneously with two fuels: a fuel with low cetane number used as the main fuel, and Diesel oil used to initiation of ignition, is assumed to be called as a dual fuel engine. This system is perfectly suited to adaptation to supply of CNG gas in majority of compression ignition engines. Such adaptations can concern both an older engine equipped with classic injection system, and modern engine with common rail system. In traction engines, interchangeability of liquid fuel by the gas belongs to important issues, what is a condition of profitability of the adaptation and operation of dual fuel engines. In the paper are presented test results of the 1CA90 engine with piston pump to injection of liquid fuel, and a system with mixer to supply of the gas; and the SB3.1 engine equipped with common rail system and injection of the gas in area of the inlet valve. On the base of performed tests one has shown variability of energetic fraction of the CNG gas in total energy supplied to the engine. The tests were performed in complete field of variability of engine parameters, i.e. rotational speed and engine load. Obtained results have shown that in spite of decreasing fraction of the gas at partial loads of medium size traction engines, substantial reduction of operational consumption of the Diesel oil is possible. Due to significant differences in price of the CNG gas and the Diesel oil, it gives considerable savings in operational costs of the engines. It should encourage users of the engines to adaptation of the fuelling to the CNG gas. In the paper is presented a proposal of control system to dual fuel traction engine, from maintaining its performance parameters point of view.
Źródło:
Journal of KONES; 2013, 20, 4; 425-434
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determinants of thermal insulating properties of walls using thermographic method
Uwarunkowania wyznaczania izolacyjności cieplnej przegród budowlanych metodą termograficzną
Autorzy:
Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/386102.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
izolacyjność cieplna
kamera termograficzna
warunki kontroli termograficznej
thermal insulation
thermographic camera
thermographic control conditions
Opis:
Heat transmission coefficient U is a measure of thermal insulating properties of walls. Its value should be determined in a stable state of heat exchange. During the in situ measurements the temperature of wall surface and heat flux density are measured with the use of a heat flow meter. These are single-point measurements and thus they do not provide a complete view of a thermal insulation of the surface. Thermographic measurement allows to achieve a surface temperature distribution. It lasts too short to conclude on its basis that the state of heat exchange was really stable. Therefore, for quantitative thermographic measurements, it is important to identify the exact conditions of heat exchange and to carefully select the time of conducting imaging procedure.
Współczynnik przenikania ciepła U jest miarą izolacyjności cieplnej przegród budowlanych. Jego wartość powinna być wyznaczana w ustalonym stanie wymiany ciepła. W warunkach in situ przeprowadza się pomiary temperatury powierzchni przegrody i gęstości strumienia ciepła z wykorzystaniem ciepłomierza. Są to pomiary punktowe, które nie dają powierzchniowego obrazu izolacyjności cieplnej. Pomiar termograficzny umożliwia uzyskanie powierzchniowego rozkładu temperatury. Trwa on zbyt krótko, by stwierdzić na jego podstawie, że stan wymiany ciepła naprawdę był ustalony. Dlatego dla ilościowych pomiarów termograficznych ważne jest dokładne rozpoznanie warunków wymiany ciepła i staranny wybór pory wykonania obrazowania.
Źródło:
Geomatics and Environmental Engineering; 2010, 4, 1/1; 163-172
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies