Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal cameras" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Assessment of Possibilities to Use Thermal Imaging Cameras for Air Traffic Control
Autorzy:
Zalewski, J.
Milewski, S.
Zabłotny, M.
Powiązania:
https://bibliotekanauki.pl/articles/320749.pdf
Data publikacji:
2017
Wydawca:
Polskie Forum Nawigacyjne
Tematy:
thermal imaging cameras
landing systems
unmanned aerial vehicles
Opis:
The character of missions and conditions in which they are carried out by military unmanned aerial vehicles are usually special and difficult. This causes a necessity to provide support for their missions, especially with regard to checking their condition on the controlled or autonomic flight path, especially during landing and take-off operations. This paper offers an account of an experiment and an attempt of assessing usefulness of thermal imaging cameras for controlling flights of aerial vehicles, mainly in areas of airdromes and approach paths.
Charakter i warunki misji statków powietrznych w operacjach wojskowych są specyficzne i trudne. Powoduje to konieczność zabezpieczenia ich działań w aspekcie kontroli sterowanego lub autonomicznego lotu, zwłaszcza podczas startów i lądowań. Artykuł stanowi opis doświadczenia oraz próbę oceny przydatności kamer termowizyjnych do kontroli lotu statków powietrznych, szczególnie w obszarach lotnisk i torów podejściowych.
Źródło:
Annual of Navigation; 2017, 24; 193-206
1640-8632
Pojawia się w:
Annual of Navigation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie parametrów zasięgowych urządzeń obserwacyjnych na podstawie pomiarów laboratoryjnych
Determination of Range Parameters of Observation Devices on the Basis of Laboratory Measurements
Autorzy:
Bareła, J.
Kastek, M.
Firmanty, K.
Powiązania:
https://bibliotekanauki.pl/articles/403380.pdf
Data publikacji:
2014
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
metrologia optoelektroniczna
kryterium Johnsona
model TTP
thermal cameras
TTP model
Johnson criterion
measure parameters of observation systems
Opis:
W artykule przedstawiono dwie najbardziej wiarygodne metody wyznaczania parametrów zasięgowych urządzeń obserwacyjnych – kryterium Johnsona i model TTP. Kryterium Johnsona jest metodą wykorzystywaną w normach NATO do wyznaczania prawdopodobieństwa detekcji, rozpoznania i identyfikacji standardowych celi NATO. Model TTP jest najnowszym sposobem wyznaczania parametrów zasięgowych urządzeń obserwacyjnych wykorzystywanym i rozwijanym głównie przez wojskowe badawcze laboratoria amerykańskie. W artykule przedstawiono uproszczony opis metody wyznaczenia parametrów zasięgowych na podstawie pomiarów laboratoryjnych. Opisano metodykę pomiaru niezbędnych paramentów potrzebnych do wyznaczenia zasięgu detekcji, rozpoznania i identyfikacji zgodnie z kryterium Johnsona oraz modelem TTP. Przedstawiono przykładowe wyniki pomiaru zasięgów kamer termowizyjnych oraz krótką analizę modeli.
The paper presents two most reliable methods used to determine the range performance of observation devices – Johnson criteria and the TTP model. Johnson criteria is used in NATO standards to determine the probability of detection, recognition and identification of standard NATO targets. TTP model is the latest concept to estimate the range parameters of observation devices, developed and used mainly by US military laboratories. The paper presents simplified description of a method applied to determine the range parameters on the basis of laboratory measurements. It provides the list of parameters and measurement methods required to estimate the detection, recognition and identification ranges according to both Johnson criteria and TTP model. Sample results obtained for thermal cameras and short model analysis are also presented.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2014, 5, 2 (16); 47-61
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie parametrów zasięgowych kamer obserwacyjnych używanych w systemach ochrony osób i mienia
Determination of range parameters of observation devices used in security systems
Autorzy:
Bareła, J.
Kastek, M.
Firmanty, K.
Powiązania:
https://bibliotekanauki.pl/articles/208722.pdf
Data publikacji:
2013
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
systemy termowizyjne
parametry zasięgowe
kryterium Johnsona
model TTP
thermal cameras
measure parameters of IR systems
Johnson criterion
TTP model
Opis:
Parametry systemów obserwacyjnych można określać na podstawie: symulacji komputerowych, badań terenowych lub pomiarów laboratoryjnych. W artykule przedstawiono sposób wyznaczania parametrów zasięgowych kamer termowizyjnych oraz VIS na podstawie pomiarów laboratoryjnych z wykorzystaniem kryterium Johnsona, a także modelu TTP. Artykuł zawiera opis metod wyznaczania parametrów zasięgowych oraz stanowiska pomiarowego. W artykule zaprezentowano przykładowe wyniki pomiarów parametrów, dwóch kamer termowizyjnych oraz dwóch kamer VIS, niezbędne do wyznaczenia parametrów zasięgowych.
Range parameters of observation devices can be determined on the basis of numerical simulations or on the basis of measured characteristics. Those measurements can be conducted in both, laboratory and field conditions. It is, however, difficult to carry on reliable field measurements of range parameters because they are strongly depended on atmospheric conditions. Thus, the laboratory measurements are more favourable option. The paper describes the measurement stand, measurement methodology and the procedure for determination of range parameters. The results for thermal and VIS cameras are also presented, and they are analyzed and compared with the results obtained from current methods, including the measurement uncertainty figures. Some suggestions on the methodology of measurements are also given.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2013, 62, 4; 129-143
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of potential fire hot spots by using a model based on a computerized real-time view with IR cameras on ships
Autorzy:
Bistrović, M.
Ristov, P.
Komorčec, D.
Powiązania:
https://bibliotekanauki.pl/articles/135424.pdf
Data publikacji:
2017
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
video technology
computer vision
infrared cameras
thermal imaging
emissivity
CCTV system
Opis:
One of the key benefits of using thermal imaging is the ability to predict possible fire hazards due to increases in temperature in controlled areas in a particular marine facility or system. This study proposes the possibility of applying new electronic and computer technology as part of a ship’s fire detection system, such as the use of computer vision, using existing marine CCTV systems and installing thermal imaging IR cameras on the same system. It also proposes communication between the CCTV system and the fire detection and central alarm system of a ship. In addition to visual analysis of certain areas on board the ship and the related facilities inside it, with the addition of certain software applications into the existing CCTV system, the system itself becomes a fire alarm system, with the potential to forecast and send early warnings to the ship’s central fire alarm system in real time, thereby contributing to improved safety with regards to various areas, equipment, the ship as a whole, cargo and human lives.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2017, 50 (122); 23-29
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Procedury rekonstrukcji scen trójwymiarowych ze stereoskopii
Reconstruction methods for 3D scenes from stereoscopy
Autorzy:
Rzeszotarski, D.
Powiązania:
https://bibliotekanauki.pl/articles/156519.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rekonstrukcja scen trójwymiarowych
stereowizja
kalibracja kamer
obrazy termowizyjne
3D scene reconstruction
stereovision
cameras calibration
thermal images
Opis:
W niniejszym artykule przedstawiono nową procedurę rekonstrukcji scen trójwymiarowych na podstawie pary współrzędnych obrazowych obserwowanych punktów. Zaproponowaną procedurę odniesiono do istniejących rozwiązań. Przeprowadzono również analizę wpływu parametrów orientacji wzajemnej między kolejnymi położeniami kamery na dokładność rekonstrukcji. Zaprezentowano wyniki rekonstrukcji syntetycznych punktów uzyskanych przy pomocy opracowanej aplikacji modelującej ruch kamery.
In this paper a new procedure for reconstruction of 3D scenes is presented. It is an extension of the method presented in [6], in which 3D reconstruction is performed by means of a 4×4 re-projection matrix on a pair of rectified stereo images. Here the 4×4 re-projection matrix is extended to general motion between two cameras or one moving camera constituting a stereoscopic set. First, the proposed reconstruction algorithm from the stereoscopic set of images is explained in detail. Two different approaches are compared: two cameras approach against a single moving camera case (Fig. 1). Next 4×4 re-projection matrix is derived for the general motion case. In Section 3 there is presented a method for evaluating the influence of camera motion parameters on the value of a 3D coordinate depth component of the reconstructed points by means of an extended reprojection matrix. Section 4 contains the results obtained by means of a special application designed for modeling motion of the camera and projection of test points used for evaluating the presented method (Fig. 2). In Fig. 3 there are defined the motion parameters used for evaluating the relation between the camera motion and the depth component estimation. Plots in Figs. 4, 5 show a dependence of the depth component value and its derivative, respectively, on the angle between x and z components of the translation vector for different camera frame rotation angles. Plots in Figs. 6, 7 present a dependence of the depth component value and its derivative, respectively, on the horizontal disparity for different camera frame rotation angle. The obtained results show that introducing rotation between cameras in a stereoscopic set can enhance the depth evaluation. The extended reprojection matrix includes, in a closed form, all necessary parameters for 3D scenes reconstruction.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 9, 9; 977-980
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies