Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "test wilgotności" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Accuracy of the cm carbide method when testing counter-floors used in the construction industry
Autorzy:
Trochonowicz, Maciej
Szostak, Bartosz
Lackorzyński, Marek
Powiązania:
https://bibliotekanauki.pl/articles/396061.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wooden floor
moisture
CM method
carbide method
counter-floor
jointless floor
podłoga drewniana
wilgotność
test wilgotności
metoda CM
Opis:
Special requirements are placed on finishing materials and foundations for these materials. The technical datasheets for wooden floors contain detailed moisture guidelines regarding counter-floors for these materials. To check the moisture level, the carbide method (CM method) is recommended by manufacturers and many specialists. The authors of the paper performed moisture tests for various counter-floors (anhydrite and cement jointless floors, cement-sand mixtures) using the direct gravimetric (laboratory) method and the carbide method. Test results were collected and analyzed.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 1; 64-73
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda wyznaczania strefy czułości sensorów TDR
Method for the determination of the sensitivity zone of TDR probe
Autorzy:
Janik, G.
Szpila, M.
Slowinska, J.
Brej, G.
Turkiewicz, M.
Skierucha, W.
Pastuszka, T.
Powiązania:
https://bibliotekanauki.pl/articles/36972.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
pomiary wilgotnosci
sensory TDR
metoda TDR
czulosc testow
gleby
moisture measurement
time domain reflectometry technique
test sensitivity
soil
Opis:
W niniejszej pracy przedstawiono metodę wyznaczania strefy czułości sensorów stosowanych do pomiaru wilgotności objętościowej w ośrodkach porowatych. Analizom poddano czujniki wykorzystujące reflektometrię domenowo czasową (TDR), wyprodukowane w Instytucie Agrofizyki Polskiej Akademii Nauk w Lublinie. Na podstawie przeprowadzonych badań laboratoryjnych stwierdzono, że zasięg strefy czułości sensorów typu laboratoryjnego i polowego jest zależny od zawartości wody w ośrodku, w którym prowadzone są pomiary. W przypadku czujnika laboratoryjnego (LP/ms), gdy oznaczenia prowadzone są w glebie całkowicie suchej, strefę czułości stanowi objętość prostopadłościanu o wymiarach 0,6 cm i 5,8 cm i grubości równej średnicy prętów sondy LP. Natomiast gdy gleba jest nasycona to strefę czułości stanowi walec eliptyczny o wysokości 5,5 cm i promieniach 0,5 cm i 0,8 cm. W przypadku czujnika polowego (FP/mts), gdy pomiary prowadzone są w glebie całkowicie suchej, strefę czułości stanowi walec eliptyczny o wysokości 10,2 cm i promieniach 0,3 cm i 0,4 cm. Natomiast gdy gleba jest nasycona wodą walec o wysokości 11,2 cm i podstawie koła o promieniu 1,7 cm.
The paper presents a method for the determination of the zone of sensitivity of probes used for the measurement of volumetric moisture in porous media. The probes under analysis were TDR (Time-Domain Reflectometry) probes manufactured at the Institute of Agrophysics, Polish Academy of Sciences, Lublin. Based on the laboratory studies performed it was found that the extent of the sensitivity zone of the field- and laboratory-type probes depends on the water content of the medium in which measurements are conducted. In the case of the laboratory probe (LP/ms), when the measurements are conducted in a completely dry soil, the zone of sensitivity of the probe is the volume of a cuboid with dimensions of 0.6 cm by 5.8 cm and a thickness equal to the diameter of the rods of the LP probe. Whereas, when the soil is saturated with water the zone of sensitivity of the probe is an elliptical cylinder with height of 5.5 cm and radii of 0.5 cm and 0.8 cm. In the case of the field probe (FP/mts), when the measurements are conducted in a completely dry soil, the probe sensitivity zone is an elliptical cylinder with height of 10.2 cm and radii of 0.3 cm and 0.4 cm. Whereas, when the soil is saturated with water that zone is a cylinder with height of 11.2 cm and a circular base with a radius of 1.7 cm.
Źródło:
Acta Agrophysica; 2011, 18, 2[193]
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmian stopnia wilgotności na charakterystyki ściśliwości w badaniach edometrycznych
Influence of change in degree of saturation on compressibility characteristics
Autorzy:
Wdowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/40465.pdf
Data publikacji:
2013
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
geotechnika
grunty
wilgotnosc gruntu
stopien wilgotnosci
scisliwosc
badania edometryczne
geotechnics
ground
ground moisture
saturation degree
compressibility
oedometer test
Opis:
Znaczący brak zgodności prognoz osiadań podłoża z wynikami pomiarów terenowych wskazuje, że charakterystyki ściśliwości spoistych gruntów prekonsolidowanych, określane za pomocą badania edometrycznego, w sposób niewystarczająco dokładny odzwierciedlają zachowanie się gruntu pod obciążeniem w terenie. Procedura badania edometrycznego jest uproszczona i nie uwzględnia wielu istotnych czynników, mających wpływ na parametry ściśliwości. Artykuł dotyczy określenia wpływu jednego z bardziej istotnych czynników (chociaż rzadko podnoszonego w literaturze geotechnicznej), tj. zmian stanu uwilgotnienia gruntu na jego charakterystyki ściśliwości. W artykule przedstawiono wyniki laboratoryjnych badań edometrycznych naturalnych prekonsolidowanych glin pochodzących z trasy obwodnicy Mińska Mazowieckiego. Wykazano, że standardowe podejście dotyczące normowych metod wyznaczania parametrów ściśliwości gruntu, które nie uwzględniają czynnika wysycenia porów wodą i jego zmienności podczas procesów obciążania i odciążania, nie jest wystarczające z punktu widzenia oceny współpracy konstrukcja – grunt. Na podstawie wyników przeprowadzonych badań podano zalecenia dotyczące sposobu uwzględnienia zmiany stopnia wilgotności w badaniach edometrycznych.
Considerable differences between predicted and actual – measured in the fi eld – deformation of subsoil create premises for hypothesis that compressibility characteristics of overconsolidated cohesive soils obtained from oedometer tests are incapable to reflect accurately soil behaviour under loading in the field. It results from the fact, that oedometer incremental loading test procedure is simplified to such extent that it does not account for many factors contributing to actual compressibility characteristics. The paper describes an approach to quantifi cation of degree of saturation infl uence on compressibility characteristics. Test results of overconsolidated medium plasticity clays sampled from route of Mińsk Mazowiecki ring road. It was shown that standard procedure for determination of compressibility parameters does not account for change in degree of saturation during loading, what results in errors in prediction of soil structure interaction. Some recommendation concerning how to account for change in degree of saturation during oedometer test were given.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2013, 12, 2
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie rozkładu oraz analiza jakości regulacji temperatury i wilgotności powietrza w przestrzeni roboczej komór klimatycznych
Research of the distribution and analysis of the quality of air temperature and humidity regulation in the working space of climatic chambers
Autorzy:
Makowska-Woźniak, I.
Powiązania:
https://bibliotekanauki.pl/articles/152360.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
komora klimatyczna
badanie rozkładu temperatury
badanie rozkładu wilgotności
badanie stabilizacji
climatic chamber
temperature distribution
humidity distribution
measurements
stability test
Opis:
W artykule przedstawiono wyniki badań niejednorodności rozkładu temperatury oraz wilgotności względnej powietrza wewnątrz przestrzeni roboczych dwóch komór klimatycznych. Dla oceny jakości regulacji układu sterującego doświadczalnie wyznaczono charakterystyki odpowiedzi układu na wymuszenie zmian temperatury oraz wilgotności w czasie oraz zbadano stabilizację parametrów w czasie.
The paper presents the results of inhomogeneity of the temperature distribution and relative humidity inside the working space of two climate chambers. From the perspective of the calibration, the knowledge of the distribution of these parameters is critical for the value of the calibration uncertainty. The deviations of the parameter values in the separate tested areas from the value of the central point of the working space of the chamber parameter were determined. The made measurements confirmed the presence of non-uniform distributions of temperature and humidity inside the working space of the chambers. For the assessment of the quality of the control system, the knowledge of the dynamics of the changes in parameters is crucial. For this reason, the response characteristics of the system to the forcing of changes in temperature and humidity in time were experimentally specified. The temperature and humidity stabilization values were set for 25 ºC and for 50 %RH. The performed tests provided information about the areas of occurrence of the factors influencing the inaccuracy of the final result of the measurement inside the working space of the climatic chambers. The set values will allow assessing the quality of the measurement results obtained in the process of calibration through estimating the uncertainty of the measurement.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 9, 9; 671-674
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania systemu ETICS z polistyrenem EPS i wełną mineralną
Testing of the ETICS system with EPS polystyrene and mineral wool
Autorzy:
Krause, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2055947.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
system ocieplania
ETICS
metoda lekka mokra
styropian
wełna mineralna
izolacja cieplna
badanie laboratoryjne
metoda badań
ściana ocieplona
rozkład temperatury
badanie wilgotności
thermal insulation system
light-weight method
EPS
expanded polystyrene foam
mineral wool
thermal insulation
laboratory test
test method
thermoinsulated wall
temperature distribution
humidity examination
Opis:
W celu określenia wpływu wzajemnego połączenia zróżnicowanych izolacji cieplnych w systmie ETICS na stan ochrony cieplno-wilgotnościowej zrealizowano badania w skali laboratoryjnej.
In order to determine the influence of the mutual connection of different thermal insulations in the ETICS system on the condition of thermal and humidity protection, laboratory scale tests were carried out.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 90--93
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ warunków magazynowania soli na jej mikrobiologiczne zanieczyszczenie
Vlijanie uslovijj khranenija povarennojj soli na ejo mikrobiologicheskoe zagrjanenie
The influence of storage-conditions of salt on its microblological contamination
Autorzy:
Korzeniowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/871661.pdf
Data publikacji:
1959
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
sol
magazynowanie
warunki przechowywania
jakosc opakowan
czas przechowywania
zmiany wilgotnosci
zanieczyszczenia mikrobiologiczne
badania mikrobiologiczne
ocena organoleptyczna
salt
storage
storage condition
packaging quality
storage time
moisture change
microbiological pollutant
microbiological test
organoleptic evaluation
Źródło:
Roczniki Państwowego Zakładu Higieny; 1959, 10, 2
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies