Tytuł:
Climatic Chamber for the Credibility Evaluation of Profilometric Measurements Construction and Control
Autorzy:
Grochalski, Karol
Wieczorowski, Michał
Pawlus, Paweł
Jakubek, Bartosz
Powiązania:
https://bibliotekanauki.pl/articles/102991.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
climatic chamber
thermal distortion
temperature measurement
PID controller
surface topography
komora klimatyczna
zniekształcenie termiczne
pomiar temperatury
regulator PID
topografia powierzchni
Opis:
The paper shows the construction and control of a climatic chamber used for the credibility evaluation of the profilometic measurements. The paper presents a control model using a PID controller and a solution for air circulation. The data regarding the influence of environmental temperature changes on the three-dimensional representation of the surface realized by means of a tactile profilometer were presented. This work shows the temperature characteristics of a climatic chamber.
Źródło:
Advances in Science and Technology. Research Journal; 2020, 14, 3; 135-140
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ maksymalnej i minimalnej temperatury otoczenia na pracę urządzeń zabezpieczających w reduktorach średniego ciśnienia o przepustowości do $60 m^3//h$
The impact of maximum and minimum ambient temperature on the operation of the safety devices in medium pressure regulators with a capacity of up to $60 m^3//h$
Autorzy:
Osika, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/1834062.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
reduktor średniego ciśnienia
temperatura
zabezpieczenie
medium pressure regulator
temperature
protection
Opis:
This article presents the experimental results of the impact of the minimum and maximum ambient temperature declared by the manufacturer on the operation of safety devices in medium pressure regulators with a capacity of up to $60 m^3//h$. The article describes the principle of operation of medium pressure regulators that are used to reduce the pressure in the device from 10 kPa to 0.5 MPa at the inlet to the outlet pressure of 1.3 kPa or 2.0 kPa depending on the value of gas pressure in installation. Selected testing methods aimed at checking the operation of safety devices at the minimum and maximum ambient temperatures have been characterized. The requirements for safety devices, as well as factory settings and the working temperature of medium pressure regulators selected for testing are described. Durability tests at minimum and maximum ambient temperature were carried out on selected samples. After each period of durability testing, safety devices have been checked, i.e.: the bleed valve which should operate in the pressure range: – 2.2±0.4 kPa for a pressure regulator with an outlet pressure of 1.3 kPa, – 3.3±0.5 kPa for a pressure regulator with an outlet pressure of 2.0 kPa; protection against pressure increase, which should work in the pressure range: – 3.2±0.4 kPa for a pressure regulator with an outlet pressure of 1.3 kPa, – 4.5±0.5 kPa for a pressure regulator with an outlet pressure of 2.0 kPa; protection against pressure drop that should work in the pressure range – 0.8±0.3 kPa for a pressure regulator with an outlet pressure of 1.3 kPa, – 1.3±0.3 kPa for a pressure regulator with an outlet pressure of 2.0 kPa; and internal tightness and closing pressure (the value of which should be ≤ 2.5 kPa for a regulator with an outlet pressure of 2.0 kPa) were checked. The laboratory tests were carried out on a test stand for medium pressure regulators in the Laboratory of Research Fittings and Operational Techniques for Pipelines at INiG – PIB. The results obtained in the tests were presented and discussed.
Źródło:
Nafta-Gaz; 2020, 76, 10; 728-734
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie regulatora rozmytego do regulacji temperatury w fizycznym modelu pomieszczeń z ogrzewaniem nadmuchowym
The application of a fuzzy controller to the temperature control in a physical model of rooms with blown heating
Autorzy:
Zawalich, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/267377.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
regulator rozmyty
regulacja temperatury
ogrzewanie nadmuchowe
model pomieszczenia
fuzzy controller
temperature control
forced air heating system
model of the room
Opis:
Jednym z przykładów zastosowania regulatorów rozmytych jest ich wykorzystanie do sterowania instalacją ogrzewania nadmuchowego. W artykule przedstawiono badania modelu obiektu złożonego z jednej nagrzewnicy zastosowanej do utrzymania różnicy temperatur w dwóch pomieszczeniach. Ideą była chęć odpowiedzi na pytanie, czy do sterowania takim obiektem można zastosować regulator rozmyty o właściwościach przybliżonych do regulatora trójpołożeniowego. Wyniki badań potwierdziły zasadność stosowania tego rodzaju regulatora, gdyż jest on w stanie generować impulsy sterujące modelowaną przepustnicą na wlocie do obu modelowych pomieszczeń. Ponadto efektem badań był wniosek, iż można pominąć zadaną wartość temperatury w jednym z modelowych pomieszczeń na rzecz określania tylko różnicy tych temperatur w obu pomieszczeniach.
Fuzzy Logic Controllers (FLC) are used in a variety of industrial solutions to control complex objects. Blowing heating is finding a growing number of supporters because it is ecological, guarantees the maintenance of an appropriate microclimate and does not cause problems with maintaining cleanliness of the rooms. Designing fuzzy controllers involves determining the membership function for the input and output quantities of the object for the adopted fuzzy sets, and then determining the inference rules, which are most often formulated on the basis of expert knowledge or based on the model of the controlled object. The proposed paper is the result of simulation tests of a physical model of two rooms heated by one heater. The system consists of two separate air containers connected to one channel, through which warm air is heated by a heater. The crosssection of the air inlet to each container can be changed by setting the throttle angle. The essence of the control consists in the appropriate selection of the amount of air flowing into each of the containers by changing the position of the throttle. The paper is an attempt to compare the control effects obtained in the system with classic controllers (PID or threeposition) and with an approximate fuzzy controller, whose inference rules should be adapted to the complex properties of the object and the applied executive elements.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 68; 69-72
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie zadania bezpiecznej pracy obiektu na przykładzie stanowiska badawczego zbudowanego w oparciu o elementy automatyki firmy JUMO
Investigation of safe operation of the object on the example of a test stand built on the basis of JUMO automation elements
Autorzy:
Chrzan, M.
Pietruszczak, D.
Wojdaszka, T.
Powiązania:
https://bibliotekanauki.pl/articles/316923.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
regulator JUMO DICON touch
ogranicznik temperatury bezpieczeństwa JUMO STB
monitor temperatury bezpieczeństwa JUMO STW
tyrystorowy sterownik mocy TYA201
controller JUMO DICON touch
safety temperature limiter JUMO STB
safety temperature monitor JUMO STW
thyristor power controller TYA201
Opis:
W artykule przedstawiono stanowisko laboratoryjne do badań właściwości dynamicznych układów regulacji na bazie elementów firmy JUMO. Opisano szczegółowo dwukanałowy, programowy uniwersalny regulator procesowy JUMO DICON touch, ogranicznik temperatury bezpieczeństwa STB wraz z monitorem temperatury bezpieczeństwa STW oraz jednofazowy tyrystorowy sterownik mocy JUMO TYA 201. W artykule zaprezentowano przykład badania laboratoryjnego zadania bezpiecznej temperatury pracy obiektu. Układ laboratoryjny pozwala między innymi zadawać bezpieczne temperatury pracy obiektu, symulować awarie grzałek i obserwować zachowanie się regulatora w czasie pracy.
The paper presents a laboratory station for testing dynamic properties of control systems based on JUMO components. Properties of the two-channel process and Program controller, STB/STW safety temperature limiter/monitor and JUMO TYA 201 single-phase thyristor power controller are described. The paper depicts an example of laboratory testing of the task of safe working temperature of an object. The laboratory system allows to set safe working temperatures, simulate heater failures, and observe the behavior of the regulator during actual operation.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 778-785, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of the Scilab software with a RTAI extension for prototyping a temperature controller of the thermal biomass processing installation
Wykorzystanie oprogramowania Scilab z nakładką czasu rzeczywistego RTAI do prototypowania regulatora temperatury instalacji do termicznego przetwarzania biomasy
Autorzy:
Wiśniewski, D.
Hałacz, J.
Wójcik, M.
Powiązania:
https://bibliotekanauki.pl/articles/93894.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
reactor
thermal processing
identification
temperature control
PID
robust controller
Scilab
reaktor
przetwarzanie termiczne
identyfikacja
regulacja temperatury
regulator odporny
Opis:
The objective of the paper was to design and test various variants of the thermal biomass processing controllers. The process took place in a batch reactor consisting of a metal chamber into which thermal energy was supplied through a diaphgram with the use of a 2 kW power ceramic band heater. The chamber of the reactor along with the heater was thermally insulated. A classic solution of a PID controller and its variety - a robust PID controller, resistant to the object parameters fluctuations was selected for tests. The Linux Debian system and the SciCosLab environment, consisting of graphic SciCos environment were used for the operation of the stand. The system kernel was modified for operation in real time through a RTAI module (Real Time Application Interface). Analysis of the results shows that, a robust controller ensures better quality, which besides a shorter time of response, behaves better in case of the object parameters fluctuations.
Celem pracy było zaprojektowanie i przetestowanie różnych wariantów sterowników procesu termicznego przetwarzania biomasy. Proces odbywał się w reaktorze wsadowym składającym się z metalowej komory do której poprzez przeponę dostarczana była energia cieplna za pomocą grzałki ceramicznej opaskowej o mocy 2kW. Komora reaktora wraz z opasującą ją grzałką była zaizolowana termicznie. Do testów wybrano klasyczne rozwiązanie regulatora PID oraz jego uodpornioną na zmiany parametrów obiektu odmianę – regulator odporny PID. Do obsługi stanowiska, wykorzystano system Linux Debian oraz środowisko SciCosLab, w którego skład wchodzi środowisko graficzne SciCos. Jądro systemu zostało zmodyfikowane do pracy w czasie rzeczywistym poprzez moduł RTAI (Real Time Application Interface). Analiza wyników wskazuje, iż lepszą jakość regulacji zapewnia regulator odporny, który poza szybszym czasem odpowiedzi, lepiej się zachowuje w przypadku zmian parametrów obiektu.
Źródło:
Agricultural Engineering; 2014, 18, 4; 241-251
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation and control of nanoparticle size distribution in a high temperature reactor
Autorzy:
Agboola, O.S.
Kolesnikov, A.
Sadiku, E.R.
Powiązania:
https://bibliotekanauki.pl/articles/778301.pdf
Data publikacji:
2012
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
regulator temperatury
nanocząstki
wielkość cząstek
średnia średnica cząstek i ścian
controller
nanoparticles
particle size
average particle diameter and wall temperature
Opis:
This work focuses on the modeling, simulation and control of particle size distribution (PSD) during nanoparticle growth with the simultaneous chemical reaction, nucleation, condensation, coagulation and convective transport in a high temperature reactor. Firstly, a model known as population balance model was derived. This model describes the formation of particles via nucleation and growth. Mass and energy balances in the reactor were presented in order to study the effect of particle size distribution for each reaction mechanisms on the reactor dynamics, as well as the evolution of the concentrations of species and temperature of the continuous phase. The models were simulated to see whether the reduced population balance can be used to control the particle size distribution in the high temperature reactor. The simulation results from the above model demonstrated that the reduced population balance can be effectively used to control the PSD. The proposed method "which is the application of reduced population balance model" shows that there is some dependence of the average particle diameter on the wall temperature and the model can thus be used as a basis to synthesize a feedback controller where the manipulated variable is the wall temperature of the reactor and the control variable is the average particle diameter at the outlet of the reactor. The influence of disturbances on the average particle diameter was investigated and controlled to its new desired set point which is 1400nm using the proportional-integral-derivative controllers (PID controllers). The proposed model was used to control nanoparticle size distribution at the outlet of the reactor.
Źródło:
Polish Journal of Chemical Technology; 2012, 14, 1; 5-13
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie piecem rezystancyjnym do wyżarzania rdzeni ze stopów amorficznych
Control of Resistive Furnace for Annealing of Amorphous Alloys
Autorzy:
Kurek, J.
Szewczyk, R.
Salach, J.
Kłoda, R.
Powiązania:
https://bibliotekanauki.pl/articles/276860.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
regulator PI
piec rezystancyjny
układ regulacji temperatury
PI controller
resistive furnace
temperature control
Opis:
W referacie przedstawiono teoretyczne i praktyczne aspekty sterowania piecem rezystancyjnym przeznaczonym do wyżarzania rdzeni magnetycznych ze stopów amorficznych w warunkach laboratoryjnych. Proces wyżarzania rdzeni wymaga zapewnienia specyficznych warunków zarówno z punktu widzenia wartości temperatury, jak i z punktu widzenia szybkości jej zmian. Przedstawione w referacie rozwiązania w zakresie regulacji umożliwiają uzyskanie niewielkiej odchyłki regulacji wartości temperatury w trakcie wyżarzania oraz szybkie dochodzenie do wartości zadanej.
Paper presents theoretical and practical aspects of automated control of resistive furnace for thermal annealing of magnetic cores made of amorphous alloys. Process of annealing requires specific conditions both from the point of view of temperature and its changes. Solutions presented in the paper creates possibility of both low value of error as well as fast achievement of set value.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 2; 128-131
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzorce promieniowania podczerwonego używane do kalibracji urządzeń termowizyjnych
Black body used to calibration thermovision systems
Autorzy:
Bareła, J.
Firmanty, K.
Kastek, M.
Polakowski, H.
Powiązania:
https://bibliotekanauki.pl/articles/208619.pdf
Data publikacji:
2012
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
ciała czarne
systemy termowizyjne
regulatory temperatury
black body
thermovision system
temperature regulator
Opis:
Wzorce promieniowania cieplnego są nieodłączną częścią wszystkich systemów pomiarowych i kalibracyjnych urządzeń termowizyjnych. Szczególne znaczenie mają one w systemach kalibracyjnych nowoczesnych pomiarowych kamer termowizyjnych oraz radiometrów obrazujących podczerwieni, ponieważ urządzenia te charakteryzują się bardzo dobrą rozdzielczością termiczną. W artykule przedstawiono zasadę działania oraz podstawowe parametry wzorców promieniowania stosowanych do kalibracji kamer termowizyjnych wytwarzanych w Instytucie Optoelektroniki Wojskowej Akademii Technicznej.
The black bodies are widely used as standard IR sources. They are applied in all measurement and calibration systems for IR devices. Nowadays, the calibration black bodies must meet very strict requirements because the spatial and spectral resolution of modern thermals cameras and spectroradiometers have been significantly improved. In this paper, the requirements for a black body are described as well as mathematical models, algorithms for temperature control and measurement results of a black body designed and manufactured at the Institute of Optoelectronics, Military Academy of Technology.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2012, 61, 2; 67-79
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Działania zmierzające do zmniejszenia zużycia energii i wody bez uszczerbku na komforcie mieszkania
Autorzy:
Kopietz-Unger, J.
Powiązania:
https://bibliotekanauki.pl/articles/162870.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
oszczędność energii
komfort użytkowania
regulator temperatury
wietrzenie pomieszczeń
oszczędzanie wody
energy conservation
use comfort
temperature controller
room airing
water conservation
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 9, 9; 37-40
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie sterowników rozmytych do optymalizacji pracy linii do ekstrudowania produktów roślinnych
Use of fuzzy controllers in optimization of operation of a line for extrusion of plant products
Autorzy:
Ekielski, A.
Powiązania:
https://bibliotekanauki.pl/articles/290694.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
ekstrudat
wilgotność
temperatura
regulator rozmyty
algorytm
extrudate
moistness
temperature
fuzzy control
algorithm
Opis:
W pracy przedstawiono projekt układu regulacji wykorzystującego prosty sterownik rozmyty wykorzystujący w procesie wnioskowania i wyostrzania algorytm Tagaki-Sugeno-Kang. Sterownik wykorzystano w procesie ekstruzji kaszki kukurydzianej. Do budowy sterownika wykorzystano pakiet oprogramowania LabView7 wraz z bibliotekami schematów. Algorytm i funkcje przynależności napisano w języku C++. Badania polegały na sprawdzeniu skuteczności w przypadku wystąpienia zakłócenia w przebiegu procesu regulacji za pomocą regulatora rozmytego. Uzyskane wyniki potwierdziły skuteczność tego systemu regulacji i jego pełną przydatność. Szczególnie dobre działanie miało miejsce w przypadku znacznego rozchwiania wartości wyjściowych, tak jak ma to miejsce w przypadku zakłócenia w dopływie materiału do ekstrudera.
The study presents a project of a control system with a simple fuzzy controller which makes use of the reasoning and sharpening process. The controller was used in the process of maize gruel extrusion. LabView7 package with chart libraries was used for construction of the controller. The algorithm and membership functions were written in the language C++. The research involved checking the effectiveness in the event of a disturbance in the course of the control process using the fuzzy controller. The obtained results confirmed effectiveness of this system of control and its full usefulness. It worked especially well in the case of a considerable difference between input values as is in the case of disturbances in inflow of material to the extruder.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 7(82), 7(82); 145-153
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of pulsing with growth regulators on senescence of the detached cold-stored leaves of Zantedeschia aethiopica Spr. and Hosta 'Undulata Erromena'
Wpływ kondycjonowania regulatorem wzrostu na starzenie się ciętych liści cantedeskii (Zantedeschia aethiopica Spr.) i funkii (Hosta 'Undulata Erromena') przechowywanych w niskiej temperaturze
Autorzy:
Skutnik, E.
Rabiza-Świder, J.
Powiązania:
https://bibliotekanauki.pl/articles/11364527.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
senescence
chlorophyll content
leaf senescence
cut leaf
leaf
low temperature
pulsing
growth regulator
Hosta
cold storage
Zantedeschia aethiopica
Opis:
Cut leaves of Zantedeschia aethiopica Spr. and Hosta ‘Undulata Erromena’ are widely used as the florists’ green. Effect of pulsing leaves with growth regulators and a storage method (dry or wet, in light or darkness, at 5°C) on postharvest longevity and chlorophyll content was investigated. Leaf vase life after 3 days storage was evaluated at 20°C and 12 h light/12 h night. Results confirmed that a dry and dark storage of Zantedeschia leaves negatively affected their decorative values while for Hosta foliage a dry storage was improper both in darkness and in light. Negative effects of storage conditions could – at least partly – be alleviated by a 24 h puls conditioning with gibberellic acid or benzyladenine for Zantedeschia and Hosta, respectively. In Zantedeschia the pulsed leaves cold stored in darkness had their vase life seven-fold that of non pulsed leaves. In Hosta pulsing leaves with BA prior to storage increased their vase life six times relative to untreated leaves, however, the cytokinin did not completely overcome a negative effect of dry storage. Positive action of both growth regulators was reflected in the leaf higher chlorophyll contents at all sampling dates.
Cięte liście cantedeskii etiopskiej (Zantedeschia aethiopica Spr.) i funkii (Hosta ‘Undulata Erromena’) stanowią bardzo wartościowy materiał uprawiany na zieleń ciętą. W pracy sprawdzono wpływ traktowania regulatorami wzrostu zastosowanego przed przechowywaniem w obniżonej temperaturze i sposobu przechowywania liści przez 3 dni w obniżonej temperaturze (5 ± 1°C) (na świetle /na mokro; na świetle /na sucho; w ciemności /na mokro; w ciemności /na sucho), na ich pozbiorcz trwałość oraz na zmiany zawartości chlorofilu w trakcie starzenia. Po przechowywaniu liście umieszczano w fitotronie (20 ±1°C w rytmie dobowym 12 h światła, 12 h ciemności). Wyniki przeprowadzonych doświadczeń potwierdziły wykazany wcześniej negatywny wpływ przechowywania ciętych liści cantedeskii etiopskiej w ciemności na sucho, a liści funkii na sucho (zarówno w ciemności, jak i na świetle) na ich dekoracyjność. Stwierdzono jednak, że negatywne skutki przechowywania ciętych liści obu gatunków w ciemności bądź na sucho można przynajmniej częściowo zniwelować, stosujc przed przechowywaniem 24-godzinne kondycjonowanie regulatorami wzrostu: w przypadku liści cantedeskii – kwasem giberelinowym, a w przypadku liści funkii – benzyloadeniną. U cantedeskii zabieg ten całkowicie niweluje negatywne skutki przechowywania w ciemności w perforowanej folii polietylenowej, utrzymujc ich trwałość na poziomie 7-krotnie wyższym od liści nietraktowanych. U liści funkii kondycjonowanie benzyloadenin zwiększa ich trwałość 6-krotnie w stosunku do liści nietraktowanych. Mimo tak dużego wzrostu trwałości, w liściach funkii traktowanych benzyloadenin utrzymuje się negatywny efekt przechowywania na sucho. Korzystny wpływ regulatorów wzrostu odzwierciedlił się w wyższym poziomie chlorofilu w liściach.
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2005, 04, 2; 101-110
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of grass cover and tillage on temperature of soil in sloping vineyard
Autorzy:
Ferrero, A.
Sudiro, L.
Nosalewicz, A.
Lipiec, J.
Powiązania:
https://bibliotekanauki.pl/articles/24929.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
traditional tillage
tillage
chemical process
environmental regulator
physical process
temperature
plant root
soil
vineyard
nutrient availability
sloping vineyard
soil temperature
grass cover
temperature variation
Źródło:
International Agrophysics; 2004, 18, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies