Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "temperature monitoring" wg kryterium: Temat


Tytuł:
Analysis of Temperatures in the Cold Storage of Finished Products
Autorzy:
Bogdanovská, Gabriela
Stehlíková, Beáta
Kačur, Ján
Powiązania:
https://bibliotekanauki.pl/articles/102539.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
cold storage warehouse
temperature monitoring
temperature fluctuations
statistical evaluation
Kruskal-Wallis test
Bartlett test
Nemenyi’s test
magazyn chłodniczy
monitorowanie temperatury
wahania temperatury
ocena statystyczna
test Kruskala-Wallisa
test Bartletta
test Nemenyi
Opis:
The analysis of temperatures in the cold store of finished products was performed due to the occurrence of temperature fluctuations. The analysis in the report was conducted using Kruskal-Wallis test, Bartlett test, Nemenyi’s test Statistical analysis of measured values in individual months. The relationship between the temperature in the cold store and the outside air temperature was investigated. Quality tools were also used in the thesis. The causes of temperature fluctuations were determined by Cause-Effect diagnostics. The relationship between the main causes was analyzed with Relation Diagram. Corrective measures were then determined to minimize the temperature fluctuations in the cold store.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 3; 54-66
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie numeryczne parametrów lokalnych komfortu cieplnego w pomieszczeniu mieszkalnym
Computational analysis of local thermal comfort factors in a habitatle room
Autorzy:
Bohojło, A.
Kołodziejczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/387459.pdf
Data publikacji:
2009
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
komfort cieplny
temperatura
wilgotność
system ANSYS
ANSYS
temperature
temperature monitoring
warmth
Opis:
W pracy wyznaczono parametry lokalne komfortu cieplnego (temperaturę wynikową, wilgotność względną, przewidywany odsetek osób niezadowolonych z przeciągu, z temperatury podłogi oraz z różnicy temperatury pomiędzy głową a kostkami nóg) na podstawie rozwiązania numerycznego nieustalonego zagadnienia wentylacji pomieszczenia mieszkalnego w programie ANSYS-CFX. Przedstawiono również ocenę zbieżności otrzymanego rozwiązania numerycznego oraz oszacowanie jego niepewności numerycznej.
This work investigates local thermal comfort factors (dry resultant temperature, relative humidity, draught rating, predicted percentage of dissatisfied caused by warm or cold floor, predicted percentage of dissatisfied from vertical air temperature difference between head and feet) via numerical analysis of a natural ventilation problem in a habitable room with ANSYSCFX. Emphasis is placed on determination of numerical uncertainty in the results.
Źródło:
Acta Mechanica et Automatica; 2009, 3, 1; 14-23
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie testowych czujników pomiaru temperatury w quasi-przestrzennych (3D) sieciach pomiarowych w hydrotechnicznych budowlach ziemnych – wyniki wstępne
Application of testing temperature sensors for quasi-dimensional (3D) measurement systems used in measuring hydrotechnical earthworks–prelilinary results
Autorzy:
Borecka, A.
Sekuła, K.
Kessler, D.
Majerski, P.
Powiązania:
https://bibliotekanauki.pl/articles/2075719.pdf
Data publikacji:
2017
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
testowy czujnik temperatury
wał przeciwpowodziowy
wyciek
monitoring termiczny
ISMOP
monitorowanie quasi-ciągłe (przestrzenne)
testing temperature sensor
levee (dike)
leakage
thermal monitoring
monitoring quasi-continuous (spatial)
Opis:
This paper presents the test point temperature sensors, designed for the ISMOP project. The point temperature sensors allow for full realization of spatial measurement by using a distributed measurement based on MESH type topology. The designed solutions described the selection and design of all elements of the sensors. It is also described how to install them at the existing levee. Applied construction and method of selection of the location of the point temperature sensors allow monitoring of levees in the quasi-spatial (3D) system, what is an alternative to termomonitoring performed by means of optical fibers.
Źródło:
Przegląd Geologiczny; 2017, 65, 10/2; 748--755
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of dynamic characteristics of a tall industrial chimney due to light wind and solar radiation
Badania dynamicznych charakterystyk wysokiego komina pod działaniem słabego wiatru i nasłonecznienia
Autorzy:
Breuer, P.
Chmielewski, T.
Górski, P.
Konopka, E.
Tarczyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/391157.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
chimney
monitoring
GPS
wind
temperature
dynamic
damping
komin
wiatr
nasłonecznienie
dynamika
tłumienie
Opis:
The present paper describes field tests conducted on the 300 m tall industrial chimney, located in the power station of Bełchatów (Poland), where the GPS rover receivers were installed at three various levels. The objectives of these GPS tests were to investigate the deformed vertical profile of this chimney, and its dynamic characteristics, i.e. the first natural frequency and the modal damping ratios. The results for the satellite signal receptions, the synopsis of recorded baselines and their ambiguity solutions, drifts of the chimney due to solar radiation and air temperature variations and dynamic wind response characteristics are presented.
W ostatnich piętnastu latach powstała nowa dziedzina monitoringu dużych budowli inżynierskich wykorzystująca technologię GPS. W niniejszej pracy opisano badania przeprowadzone na wysokim, 300-metrowym kominie przemysłowym elektrowni Bełchatów, gdzie odbiorniki GPS umieszczono w trzech różnych poziomach. Według rozeznania autorów jest to pierwszy przypadek takiego użycia techniki GPS do obserwacji wysokiej budowli pod równoczesnym działaniem słabego wiatru oraz zmian temperatury otoczenia i nasłonecznienia. Celem badań było wyznaczenie geometrii odkształconej osi pionowej trzonu komina i jego parametrów dynamicznych, tj. pierwszej częstości drgań własnych i modalnych liczb tłumienia. Opisano warunki odbioru sygnałów satelitarnych systemu GPS, przedstawiono wyniki pomiarów przemieszczeń trzonu wywołanych nasłonecznieniem i wyniki analizy odpowiedzi dynamicznej konstrukcji komina wywołanej działaniem wiatru.
Źródło:
Budownictwo i Architektura; 2013, 12, 2; 87-94
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature detection based on nonparametric statistics of ultrasound echoes
Autorzy:
Byra, M.
Gambin, B.
Powiązania:
https://bibliotekanauki.pl/articles/332315.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
noninvasive temperature monitoring
nonparametric statistics
ultrasound backscattering
Opis:
Different ultrasound echoes properties have been used for the noninvasive temperature monitoring. Temperature variations that occur during heating/cooling process induce changes in a random process of ultrasound backscattering. It was already proved that the probability distribution of the backscattered RF (radio frequency) signals is sensitive to the temperature variations. Contrary to previously used methods which explored models of scattering and involved techniques of fitting histograms to a special probability distribution two more direct measures of changes in statistics are proposed in this paper as temperature markers. They measure the ''distance'' between the probability distributions. The markers are the Kolmogorov Smirnov distance and Kulback-Leiber divergence. The feasibility of using such nonparametric statistics for non- invasive ultrasound temperature estimation is demonstrated on the ultrasounds data collected during series of heating experiments in which the temperature was independently registered by the classical thermometer or thermocouples.
Źródło:
Hydroacoustics; 2015, 18; 17-23
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature Monitoring during Focused Ultrasound Treatment by Means of the Homodyned K Distribution
Autorzy:
Byra, M.
Kruglenko, E.
Gambin, B.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1032313.pdf
Data publikacji:
2017-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
temperature monitoring
homodyned K distribution
focused ultrasound
Opis:
Temperature monitoring is essential for various medical treatments. In this work, we investigate the impact of temperature on backscattered ultrasound echo statistics during a high intensity focused ultrasound treatment. A tissue mimicking phantom was heated with a spherical ultrasonic transducer up to 56°C in order to imitate tissue necrosis. During the heating, an imaging scanner was used to acquire backscattered echoes from the heated region. These data was then modeled with the homodyned K distribution. We found that the best temperature indicator can be obtained by combining two parameters of the model, namely the backscattered echo mean intensity and the effective number of scatterers per resolution cell. Next, ultrasonic thermometer was designed and used to create a map of the temperature induced within the tissue phantom during the treatment.
Źródło:
Acta Physica Polonica A; 2017, 131, 6; 1525-1528
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of the procedure of diagnostic inference for TPMS
Modyfikacja procedury wnioskowania diagnostycznego dla układu TPMS
Autorzy:
Cieślikowski, B.
Cygnar, M.
Kochanek, A.
Powiązania:
https://bibliotekanauki.pl/articles/334808.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
TPMS
Tyre-Pressure Monitoring System
tyre
temperature control
procedure
układ TPMS
kontrola temperatury
opona
procedura
Opis:
The subject of the paper is to modify the procedure of inference for TPMS (Tyre-Pressure Monitoring System) with regard to an earlier identification of the excessive temperature rise in tyres before they exceed thermal limits. This shall allow to limit the risk of accidents caused by destruction of a tyre. An important issue indicating functional features of TPMS consists in a possibility of rapidly warning a driver immediately after a potentially dangerous rise of temperature. Traction tests have been carried out with use of a passenger car equipped with TPMS with P409 sensors and TH9P409S measuring module. Time characteristics of tyre temperature signals were included indicating the way of their use for the process of estimation of a warning signal. A change trend model of an analysed parameter in time function was developed.
Przedmiotem publikacji jest modyfikacja procesu wnioskowania w systemie TPMS (Tyre Pressure Monitoring System) w zakresie wcześniejszej identyfikacji nadmiernego przyrostu temperatury opony zanim zostaną przekroczone limity dopuszczalne. Pozwoli to na ograniczenie skutków destrukcji opony zmniejszając przy tym ryzyko wypadkowości. Istotnym zagadnieniem wyrażającym cechy funkcjonalne układu TPMS jest zdolność szybkiej estymacji sygnału ostrzegawczego o stanie awaryjnym opony. Przeprowadzono testy trakcyjne samochodu osobowego wyposażonego w układ TPMS z czujnikami P409 i modułem pomiarowym TH9P409S. Zamieszczono charakterystyki czasowe sygnałów temperatury opony wskazując na ich wykorzystanie dla estymacji sygnału ostrzegawczego. Opracowano model trendu zmiany analizowanego parametru w funkcji czasowej.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2016, 61, 3; 53-56
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cointegration method for temperature effect removal in damage detection based on Lamb waves
Wykrywanie uszkodzeń przy pomocy fal Lamba - kompensacja wpływu temperatury oparta o metodę kointegracji
Autorzy:
Dao, P. B.
Powiązania:
https://bibliotekanauki.pl/articles/328179.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
structural health monitoring
Lamb waves
cointegration
temperature effect removal
wykrywanie uszkodzeń
konstrukcja
fale Lamba
kointegracja
kompensacja wpływu temperatury
Opis:
The paper presents an application of the cointegration technique for temperature effect removal in Lamb wave data. The method is based on the analysis of cointegration residuals and stationary statistical characteristics. The experimental results on Lamb wave responses from undamaged and damaged aluminium plates show that the cointegration process can remove undesired temperature effects and accurately detect damage.
Fale Lamba stosowane są do wykrywania uszkodzeń w konstrukcjach płytowych. Wpływ temperatury na amplitudę oraz fazę fal Lamba jest jedną z głównych przeszkód w powszechnym zastosowaniu tej metody w praktyce inżynierskiej. W pracy zastosowano metodę kointegracji do kompensacji wpływu temperatury na propagację fal Lamba. Metoda oparta jest na badaniu stacjonarności sygnałów. Zastosowane podejście pokazane jest na przykładzie wykrywania szczelin zmęczeniowych w płytach aluminiowych. Wyniki pokazują, że metoda kointegracji skutecznie usuwa z fal Lamba wszystkie efekty związane z wpływem temperatury, przyczyniając się do wykrycia badanych uszkodzeń.
Źródło:
Diagnostyka; 2013, 14, 3; 61-67
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorithms for the remote sensing of the Baltic ecosystem (DESAMBEM). Part 2: Empirical validation
Autorzy:
Darecki, M.
Ficek, D.
Krezel, A.
Ostrowska, M.
Majchrowski, R.
Wozniak, S.B.
Bradtke, K.
Dera, J.
Wozniak, B.
Powiązania:
https://bibliotekanauki.pl/articles/47590.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
light-photosynthesis model
algorithm
chlorophyll
ocean colour
temperature
marine ecosystem
monitoring
empirical validation
primary production
Baltic ecosystem
remote sensing
Opis:
This paper is the second of two articles on the methodology of the remote sensing of the Baltic ecosystem. In Part 1 the authors presented the set of DESAMBEM algorithms for determining the major parameters of this ecosystem on the basis of satellite data (see Woźniak et al. 2008 – this issue). That article discussed in detail the mathematical apparatus of the algorithms. Part 2 presents the effects of the practical application of the algorithms and their validation, the latter based on satellite maps of selected Baltic ecosystem parameters: the distributions of the sea surface temperature (SST), the Photosynthetically Available Radiation (PAR) at the sea surface, the surface concentrations of chlorophyll a and the total primary production of organic matter. Particular emphasis was laid on analysing the precision of estimates of these and other parameters of the Baltic ecosystem, determined by remote sensing methods. The errors in these estimates turned out to be relatively small; hence, the set of DESAMBEM algorithms should in the future be utilised as the foundation for the effective satellite monitoring of the state and functioning of the Baltic ecosystem.
Źródło:
Oceanologia; 2008, 50, 4; 509-538
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unusual Baltic inflow activity in 2002-2003 and varying deep-water properties
Autorzy:
Feistel, R.
Nausch, G.
Hagen, E.
Powiązania:
https://bibliotekanauki.pl/articles/48654.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
Sopot
temperature
inflow
residence time
deep water renewal
conference
salinity
Baltic Sea
Baltic Monitoring Programme
Opis:
The unusual sequence of inflow events into the Baltic Sea that occurred in 2002 and 2003 includes the first ever important baroclinic inflow to be described (August 2002), the Major Baltic Inflow (January 2003), which gave rise to the highest oxygen levels in the Gotland Deep since the 1930s, and the baroclinic inflow (August 2003) that elevated the Gotland Basin deep water salinity to values last observed in 1977, and caused the surface salinity to rise again. From these trend changes, salt residence times were estimated at about 20 years in the deep waters and 30 years above the pycnocline. Ventilation of the remote Karlsö Deep took until 2005, two years after the inflow event responsible, at a time when the Bornholm and Eastern Gotland Basins were already returning to stagnation.
Źródło:
Oceanologia; 2006, 48, S
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary temperatury skóry jako etap projektowania specjalistycznej odzieży tekstronicznej
Skin temperature measurements as a design step of special textronics clothes
Autorzy:
Frydrysiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/261373.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
pomiar temperatury
obraz termowizyjny
homeostaza
tekstronika
monitoring
temperature measurement
thermography
homeostasis
textronics
Opis:
W pracy opisano zachowanie organizmu człowieka pod wpływem zmian temperatury otoczenia. Przedstawiono metody oraz wyniki pomiaru rozkładu temperatury skóry człowieka w różnych warunkach środowiskowych. Badania przeprowadzono za pomocą termowizji. Pomiary te są podstawą do projektowania odzieży tekstronicznej. Tego typu odzież służy do ciągłego, nieinwazyjnego monitoringu jednego z podstawowych parametrów fizjologicznych człowieka, jakim jest temperatura.
The physiological behavior of the human organism in changing ambient temperature is described. The measurements of the temperature distribution on the human skin under various environmental conditions are presented. As a measurement method, thermovision imaging was exploited as the step in the design process of special textronics clothing. This kind of clothing offer a non-invasive continuous monitoring of an important human physiological parameter, namely the temperature.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2015, 21, 2; 91-101
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interpretacja zmienności temperatury wody w źródle na wschodnim stoku Zameczków (Tatry Zachodnie) na podstawie ciągłych obserwacji monitoringowych i numerycznego modelu transportu ciepła
Interpretation of water temperature changes in the spring on the eastern side of the Zameczki mountain (West Tatra Mts.) based on continuous monitoring and a numerical heat transport model
Autorzy:
Gruszczyński, Tomasz
Szostakiewicz-Hołownia, Marzena
Powiązania:
https://bibliotekanauki.pl/articles/2061534.pdf
Data publikacji:
2019
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
badania monitoringowe
temperatura wód podziemnych
transport ciepła
Tatry Zachodnie
monitoring studies
groundwater temperature
heat transport
West Tatra Mts.
Opis:
Prowadzone w sposób ciągły długoterminowe obserwacje temperatury wody ze źródła na wschodnim stoku Zameczków dostarczyły danych do oceny zmienności tego parametru w czasie. W artykule podjęto próbę interpretacji uzyskanych wyników za pomocą niestacjonarnego, numerycznego modelu transportu ciepła i mieszania wód. Wymagało to opracowania modelu konceptualnego, którego poprawność weryfikowano na podstawie oceny dopasowania obliczonej i pomierzonej temperatury wody. W wyniku tarowania modelu określono średnie wartości współczynnika przewodności cieplnej skał na poziomie 1,4 Wm–1K–1 oraz ciepła właściwego układu woda–skała na poziomie 0,92 kJkg–1K–1, przy wartościach błędu średniego i błędu średniego bezwzględnego wynoszących odpowiednio 0,08 i 0,28°C. Zgodnie z przyjętym modelem zmienność temperatury wody na wypływie można wyjaśnić kondukcją ciepła w strefie sezonowych fluktuacji oraz dopływem wód podziemnych ze strefy neutralnej. Na podstawie obliczeń modelowych udało się określić ilościowy udział wód reprezentujących różne strefy głębokościowe. Rezultaty wskazują, że 67% wód zasilających badane źródło powiązanych jest z płytką strefą krążenia, w której główną determinantą temperatury wody jest kondukcyjny strumień ciepła skierowany prostopadle do powierzchni terenu. Pozostałe 33% dopływu reprezentuje głębszy system krążenia, który można identyfikować ze strefą neutralną. W strefie tej temperatura wody zbliżona jest do średniej rocznej temperatury powietrza, a gradienty temperatury przyjmują niewielkie wartości zarówno w odniesieniu do czasu, jak i przestrzeni.
Long-term observations of water temperature in the spring on the eastern side of the Zameczki mountain allow collecting a set of data showing variability of this parameter in time. The paper presents an interpretation of this data by a non-stationary numerical model of heat transport and water mixing. Quantitative interpretation of the results required constructing a conceptual model, whose correctness was verified on the basis of evaluation of calculated and measured water temperature. Due to the model calibration it was possible to establish the mean values of heat conductivity of the rocks at 1.4 Wm–1K–1 and the water-rock specific heat capacity at 0.92 kJkg–1K–1 with the mean error and mean absolute error at the level of 0.08 and 0.28ºC, respectively. According to this model, variability of water temperature in the spring can be explained by conductive heat transport in the zone of seasonal fluctuations and by the groundwater inflow from the neutral zone. Based on the model calculations it was possible to determine the quantitative share of waters representing different depth zones. The results indicate that 67% of water recharging the spring is linked with the shallow circulation zone, in which the main temperature determinant is the conductive heat stream directed perpendicular to the terrain surface. The remaining 33% of the inflow represents a deeper circulation system that can be identified with the neutral zone. In this zone, water temperature is close to the annual mean air temperature and the temperature gradients have small values both in space and time .
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2019, Hydrogeologia z. 16; 43--50
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Optical Fiber Macrobendings in Temperature Sensor Dedicated for Power Transformer Monitoring
Ocena wprowadzanych makrozgięć na światłowodzie na działanie czujnika temperatury dedykowanego do monitorowania transformatorów
Autorzy:
Guzowski, Bartłomiej
Łakomski, Mateusz
Shatarah, Iyad S. M.
Powiązania:
https://bibliotekanauki.pl/articles/27312472.pdf
Data publikacji:
2023
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
GaAs sensor
temperature
power transformer
optical fiber
monitoring
sensor GaAs
temperatura
transformator
światłowód
monitorowanie
Opis:
Optical fiber sensing techniques are recognized as very promising in diagnostic and condition monitoring of power transformers. According to the IEC standard 60076-2, the winding hot-spot temperature can be designated with the optical fiber sensor. In this paper, the investigation of the influence of macrobending of the optical fiber temperature sensor on the sensing performance is presented. The obtained results prove that the optical fiber sensor wrapped six times around the 14 mm cylinder still provides temperature sensing abilities.
Sensory światłowodowe doskonale sprawdzają się w diagnostyce i monitorowaniu stanu transformatorów. Norma IEC 60076-2:2011 wskazuje na możliwość użycia czujników światłowodowych do pomiaru temperatury uzwojenia transformatora. W niniejszym artykule badany jest wpływ makrozgięć na działanie światłowodowego czujnika temperatury. Uzyskane dane potwierdzają, że czujnik nadal działa prawidłowo, pomimo wprowadzonego makrozgięcia w postaci sześciokrotnego zawinięcia światłowodu wokół cylindra o średnicy 14 mm.
Źródło:
Pomiary Automatyka Robotyka; 2023, 27, 4; 39--44
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja monitoringu temperatury ciała cieląt
The concept of calf body temperature monitoring
Autorzy:
Jędruś, A.
Lipiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/288554.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
temperatura ciała
cielę
monitoring
calf
body temperature
Opis:
Przedstawiono wyniki badań pomiaru temperatury cieląt z zastosowaniem różnych narzędzi pomiarowych. Analizy wykazały, że zaproponowany dotykowy sposób pomiaru temperatury cieląt z użyciem termistora zainstalowanego w automatycznej stacji odpajania cieląt jest niepewny i nieefektywny. Może być on stosowany tylko jako źródło sygnałów alarmowych o podwyższonej temperaturze ciała cieląt. Z kolei najdokładniejszym sposobem pomiaru temperatury ciała cieląt jest stosowanie kamery termowizyjnej, ale jej wadą jest bardzo wysoka cena.
The work presents the research results for calf temperature measurement using various measuring tools. Completed analyses have shown that the proposed touch measurement method for calf temperature using a thermistor installed in automatic feeding stations is unreliable and ineffective. It may be used only as a source of alarm signals in case of high calf body temperature. As concerns the calf body temperature measurement, using a thermovision camera is the most precise method, however a very high price is its disadvantage.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 1, 1; 229-234
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tools for optimizing performance of VOYages at sea
Autorzy:
Johannessen, J. A.
Perrin, A.
Gaultier, L.
Herlédan, S.
Pouplin, C.
Collard, F.
Maze, J. P.
Dussauze, M.
Rapp, J.
Fanebust, R.
Andersen, S.
Franks, O.
Meyer, R.
Powiązania:
https://bibliotekanauki.pl/articles/1841544.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
voyage at sea
Copernicus Marine Environment Monitoring Service
optimization tool
synthetic aperture radar
finite-size lyapunov exponent
route optimization
sea surface temperature
route optimization algorithm
Opis:
The aim of the TOPVOYS project supported by the MarTERA ERA-Net Cofund program within the European Commission is to advance and implement analyses tools and decision support system for voyage optimisation. Based on marine weather analyses and forecasts combined with near real time satellite-based observations of wind, wave and surface current conditions as well as sea surface temperature fields the best shipping route are examined. The proposed approach aims to identify the optimum balance between minimisation of transit time and fuel consumption as well as reduction of emissions without placing the vessel at risk to damage and or crew injury. As such it is compliant with the International Maritime Organization guidelines [6] for ship routeing to keep the traffic smooth and avoid accidents, notably in the presence of unfavorable marine meteorological conditions. The tool performances will be demonstrated both in post-voyage analyses and real time operations for the North Atlantic Ocean crossings, voyages from Europe through the Mediterranean Sea and the Suez Channel to the Far East (e.g. China, South Korea) and voyages around Southern Africa.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2021, 15, 1; 233-239
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies