Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "temperature diagnostics" wg kryterium: Temat


Tytuł:
Analytical method of determining dynamic properties of thermocouples used in measurements of quick – changing temperatures of exhaust gases in marine diesel engines
Analityczna metoda wyznaczania własności dynamicznych termopar stosowanych w pomiarach szybko zmiennej temperatury spalin wylotowych silnika okrętowego
Autorzy:
Korczewski, Z.
Puzdrowska, P.
Powiązania:
https://bibliotekanauki.pl/articles/132979.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
technical diagnostics
marine diesel engine
dynamic exhaust gas temperature measurements
diagnostyka techniczna
okrętowy silnik tłokowy
dynamiczne pomiary temperatury spalin wylotowych
Opis:
The article presents selected issues of mathematical modeling of heat exchange between the thermocouple and the exhaust gas flowing them, in unsteady conditions. On the way of energy balancing consideration of thermodynamic processes developed differential equations describing the dynamic properties for three versions of the design sheathed thermocouples: with weld isolated from the sheath, with weld welded the sheath and with the open weld. On this basis were determined the equations describing the time constants. After substituting the appropriate the input data : materials and heat-flow, provided by the manufacturer (the company "Termo-Precyzja") it was possible to compare the numerical values of the time constants of thermocouples and make a rational choice for the diagnostic tests conducted marine diesel engines.
W artykule przedstawiono wybrane zagadnienia modelowania matematycznego wymiany ciepła pomiędzy termoparą i omywających ją spalinami w warunkach nieustalonych. Na drodze bilansowania energii rozpatrywanych procesów termodynamicznych opracowano równania różniczkowe opisujące cechy dynamiczne trzech wersji konstrukcyjnych termopar płaszczowych: ze spoiną izolowaną od płaszcza, ze spoiną zgrzewaną do płaszcza i ze spoiną odkrytą. Na tej podstawie wyznaczono równania opisujące ich stałe czasowe. Po podstawieniu odpowiednich danych wejściowych: materiałowych i cieplno-przepływowych, udostępnionych przez producenta (firma „Termo-Precyzja”) możliwe było porównanie wartości liczbowych stałych czasowych tych termopar i dokonanie racjonalnego doboru dla potrzeb prowadzonych badań diagnostycznych silników okrętowych.
Źródło:
Combustion Engines; 2015, 54, 3; 300-306
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania temperaturowe modułów elektronicznych
Temperature testing of electronic modules
Autorzy:
Ćwirko, J.
Ćwirko, R.
Powiązania:
https://bibliotekanauki.pl/articles/209036.pdf
Data publikacji:
2008
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
diagnostyka temperaturowa
bezkontaktowy pomiar temperatury
temperaturowy system skaningowy
test burn-in
temperature diagnostics
non-contact temperature measurement
temperature mapping system
burn test
Opis:
W artykule przedstawiono system pomiarowy do wyznaczania rozkładu temperatury modułów elektronicznych. Czujnik pirometryczny umożliwia wykonanie bezkontaktowych pomiarów temperatury. Przedstawiony system umożliwia badania dwu- lub trójwymiarowych rozkładów wartości temperatury płyt głównych komputerów PC lub central alarmowych. W drugiej części artykułu przedstawiono zrealizowane stanowisko pomiarowe do wykonywania badań środowiskowych typu burn-in.
In this paper, the temperature mapping system for electronic devices is presented. The pyroelectronic temperature sensor enables non-contact measurements. The measured system provides two or three dimensions temperature scan of electronic modules as PC motherboards or security system motherboards. In the second part of this paper, the measurement system for thermal environment test on security system modules is presented.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2008, 57, 2; 133-142
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer system for temperature diagnostics of cows
Komputerowy system diagnostyki temperaturowej krów
Autorzy:
Jędruś, A.
Powiązania:
https://bibliotekanauki.pl/articles/93754.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
machine milking
cow
diagnostics
milk
temperature
intelligent system
dój maszynowy
diagnostyka
krowa
temperatura
mleko
system inteligentny
Opis:
The objective of the paper was to draw out a functional profile of a new computer system for temperature diagnostics of cows. This device enables oestrus detection including the silent one, early pregnancy (from the 5th day of insemination), acute inflammatory conditions and subclinical mastitis in a non-invasive manner during machine milking of cows. For diagnostic purposes one type of the measurement sensor was used, which is a unique feature in comparison to diagnostic devices mass produced and available on the market. A microprocessor module of the new milking system has intelligent devices features. It is construed of modern analogue and digital subassemblies and specialised measurement interfaces. The program structure of the system enables processing of automatically registered milk temperature values during cow milking on account of requirements of cow temperature diagnostics.
Celem pracy była charakterystyka funkcjonalna nowego komputerowego sytemu diagnostyki temperaturowej krów. Urządzenie umożliwia wykrywania rui, w tym cichej, wczesnej ciąży (od 5 dnia po inseminacji), ostrych stanów zapalnych i stanów podklinicznych płatów wymion krów w sposób bezinwazyjny, w czasie doju maszynowego krów. Do celów diagnostycznych zastosowano jeden typu czujnika pomiarowego, co jest cechą unikalną w porównaniu z dostępnymi na rynku produkowanymi seryjnie urządzeniami diagnostycznymi. Moduł mikroprocesorowy nowego systemu udojowego posiada cechy urządzeń inteligentnych. Zbudowany jest z nowoczesnych podzespołów analogowych i cyfrowych oraz specjalizowanych interfejsów pomiarowych. Struktura programowa systemu umożliwia przetwarzanie rejestrowanych automatycznie w czasie dojów krów wartości temperatur mleka pod kątem wymagań diagnostyki temperaturowej krów.
Źródło:
Agricultural Engineering; 2016, 20, 2; 91-99
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conception of the Arduino platform as a base for the construction of distributed diagnostic systems
Autorzy:
Haniszewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/198441.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
measurement
Arduino
diagnostics
distributed system
temperature
acceleration
data transmission
pomiary
diagnostyka
system rozproszony
temperatura
przyspieszenie
transmisja danych
Opis:
Systems for distributed parameter measurements are very expensive solutions; however, they offer many possibilities in terms of real-time verification of machine status. Of course, ready, complex and easy-to-use measuring systems can be used, where the cost of such a solution may be prohibitive. In the case of research carried out under the experimental sphere of an object, e.g., using a research measurement system, it is possible to create a project for a system based mainly on the Arduino platform. As an example, the concept of a distributed measurement system will be presented, with the possibility for use on cranes and conveyors, i.e., on the most common machines on industrial plants.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2016, 93; 31-40
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conditions for the use of infrared camera diagnostics in energy auditing of the objects exposed to open air space at isothermal sky
Autorzy:
Kruczek, T.
Powiązania:
https://bibliotekanauki.pl/articles/240912.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermovision diagnostics
infrared camera
radiative ambient temperature
open air space
diagnostyka termowizyjna
kamera termowizyjna
radiacyjna temperatura otoczenia
otwarta przestrzeń
Opis:
Convective and radiation heat transfer take place between various objects placed in open air space and their surroundings. These phenomena bring about heat losses from pipelines, building walls, roofs and other objects. One of the main tasks in energy auditing is the reduction of excessive heat losses. In the case of a low sky temperature, the radiation heat exchange is very intensive and the temperature of the top part of the horizontal pipelines or walls is lower than the temperature of their bottom parts. Quite often this temperature is also lower than the temperature of the surrounding atmospheric air. In the case of overhead heat pipelines placed in open air space, it is the ground and sky that constitute the surroundings. The aforementioned elements of surroundings usually have different values of temperature. Thus, these circumstances bring about difficulties during infrared inspections because only one ambient temperature which represents radiation of all surrounding elements must be known during the thermovision measurements. This work is aimed at the development of a method for determination of an equivalent ambient temperature representing the thermal radiation of the surrounding elements of the object under consideration placed in open air space, which could be applied at a fairly uniform temperature of the sky during the thermovision measurements as well as for the calculation of radiative heat losses.
Źródło:
Archives of Thermodynamics; 2015, 36, 1; 67-82
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CVD diamond detectors for fast alpha particles escaping from the tokamak D-T plasma
Autorzy:
Wodniak, I.
Drozdowicz, K.
Dankowski, J.
Gabańska, B.
Igielski, A.
Kurowski, A.
Marczewska, B.
Nowak, T.
Woźnicka, U.
Powiązania:
https://bibliotekanauki.pl/articles/146634.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
CVD diamond detector
lost alpha particles
high temperature plasma diagnostics
Opis:
Measurements of the so-called lost alpha particles escaping from thermonuclear plasma in future tokamaks (such as ITER) for energy production would be essential for monitoring the energy balance in these devices. The detection would have to be carried out in a harsh environment (with high nuclear radiation fluxes, high temperature, etc.), which limits the use of common semiconductors for charged particle detection. Diamond seems to be an attractive material for alpha particle detectors in these conditions. In this paper an analysis of properties of a diamond detector for spectrometric alpha measurements is reported. A high purity CVD (chemical vapour deposition) single crystal diamond detector was used, fabricated for this dedicated application by the Diamond Detector Ltd. The energy calibration was carried out using a triple alpha particle isotope source, AMR33 (239Pu, 241Am, 244Cm). A very good energy resolution, ca. 20 keV at ca. 5.5 MeV had been obtained, which is comparable to that of the silicon detector. The linearity of the diamond detector amplitude response to the alpha particle energy was analyzed with the use of mono-energetic (0.4–2 MeV) ion beam from a Van de Graaff accelerator. Results of the measurements using the AMR33 source deviate at most 30 keV from the calibration line obtained in this way.
Źródło:
Nukleonika; 2011, 56, 2; 143-147
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining the time constant using two methods and defining the thermocouple response to sine excitation of gas turbine
Autorzy:
Puzdrowska, P.
Powiązania:
https://bibliotekanauki.pl/articles/2073631.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
piston compressor
gas temperature measurements
diagnostics
time constant of the thermocouple
sprężarki tłokowe
pomiar temperatury spalin
diagnostyka
stała czasowa termopary
Opis:
This paper describes the two methods of determining the time constant of type K thermocouple, for two construction solutions: the exposed weld and the mantle fillet weld. This is an important parameter indicating the response time of the thermocouple on the recorded signal. The first method consists of determining the value of τ in the way of numerical simulation of heat exchange between the thermocouple and the current of gas [2] for the parameters adopted for the gas and for the known construction of the temperature sensor. The second method is a graphical determination of these parameters on the basis of the sequence of high frequency temperature of gas. The study was conducted to determine the position of the dynamic properties of thermocouples [3]. Based on these results was made the choice of the thermocouple with the best dynamic properties, which helped during the tests on the reciprocating compressor [4]. On the basis of the sequence of high frequency temperature and gas pressure was determined the response of the thermocouple on the sine excitation of gas temperature (the phase and amplitude displacement of the sequence) [5]. The used method of signal correction was rated and its suitability for diagnostic testing of piston machines was determined.
Źródło:
Journal of Polish CIMEEAC; 2016, 11, 1; 157--167
1231-3998
Pojawia się w:
Journal of Polish CIMEEAC
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosing the thermostat using vehicle on-board diagnostic (OBD) data
Autorzy:
Witaszek, Kazimierz
Witaszek, Mirosław
Powiązania:
https://bibliotekanauki.pl/articles/27313825.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
thermostat
diagnostics
malfunction
coolant temperature
fuel consumption
termostat
zużycie paliwa
diagnostyka
temperatura płynu chłodzącego
Opis:
The thermostat is a crucial component of a car's internal combustion engine's cooling system. Failure of the thermostat can result in undercooling or overheating of the engine. Undercooling may increase wear of engine components due to poor lubrication and lead to higher fuel consumption. Conversely, overheating can damage the engine. The engine coolant temperature is one of the fundamental parameters for the proper functioning of the engine. The vehicle's onboard diagnostics system was unable to detect the malfunction of the thermostat. As a consequence, fuel consumption increased, which was especially noticeable in winter. This paper evaluates the possibility of carrying out thermostat diagnostics using data obtained from the OBD system through a diagnostic interface ELM327, which is connected to the OBD-II connector and interfaced with Torque Pro software on a smartphone. Analysis of the data confirmed that the proposed diagnostic method was appropriate. Furthermore, the impact of the thermostat malfunction on different factors such as coolant temperature, cold engine warm-up time, parameters characterising thermostat cycling, and fuel consumption of the car were studied. It was found that, apart from the already mentioned decrease in coolant temperature, the thermostat hysteresis also decreased and the thermostat cycle time increased.
Źródło:
Diagnostyka; 2023, 24, 4; art. no. 2023402
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka stanu czujnika termoelektrycznego w procesie zgazowania biomasy
Diagnosis of the thermocouple in the proces of gasification of biomass
Autorzy:
Zyska, T.
Wójcik, W.
Imanbek, B.
Zhirnova, O.
Powiązania:
https://bibliotekanauki.pl/articles/1818102.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zgazowarka
pomiar temperatury
diagnostyka
gasifier
temperature measurement
diagnostics
Opis:
One of the methods of obtaining energy from renewable sources is the biomass gasification. For economic reasons, and taking into account the security aspects, it is important to ensure that the process is optimal. The gasification process can be optimized regarding the product energy, especially concentration of hydrocarbons and their derivatives or tar substrates, such optimization requires precise knowledge of temperatures in the gasification reactor. The temperatures inside the reactor determine the speed and quality of gasification process and are one of the most important parameters for control and monitoring systems of gasifier operation. Thermocouples are most widely used for temperature monitoring. That is the reason why it is important to acquire precise temperature readout regardless of aging processes. The significance of accurate temperature determining has been demonstrated with the use of a simplified mathematical model of a reactor assuming ideal reagents mixing. The presented mass and energy balance equations have led to determine the temperature changes during the analyzed process. The final equation is a base for the optimization of the gasification process and contains quantity of measured temperature. The main problem is the accuracy of temperature measurement. The authors have developed the in-situ method of diagnostics of thermocouples, that allows determination of the relative deviation of the sensor thermoelectric force during its operation. Besides characteristic parameters such as material properties the model includes the internal heat transfer, as well. The presented diagnostic method consists in determining the electromotive force of a newly installed sensor, and then determination of characteristic parameters using two selected values of testing current. During operation of the monitored sensor, periodic determination of the relative deviation of the Seebeck coefficient is required. This relative deviation should be compared to its permissible level, that is specified for the process being monitored. The proposed method belongs to the class of comparative ones, where the comparison is related to the indications of the same sensor (the new one and in-service). Experimental verification of the presented method was carried out using gasifier with nominal thermal load of 50kW, fed with wood pellets. The temperature of synthesis gas was measured by the two sensors, the reference sensor and the second one, that was driven by pulses of a testing current. For both current directions the thermoelectric force has been determined. The difference of the obtained electromotive forces is diagnostic information, that is needed to calculate the relative change of the Seebeck coefficient. The proposed solution allows diagnosing thermocouples located in confined areas. Moreover, additional benefit is the possibility of sensors diagnosis without stopping the process being monitored. It is important for both economic and technological reasons.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 652-666
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part I. Steady-state processes
Autorzy:
Korczewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/258576.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
technical diagnostics
naval turbine engines
exhaust gas temperature
steady-state processes
Opis:
The article presents a possible method of detecting failures in the flow section and supply system of a naval gas turbine engine based on the exhaust gas temperature measured behind the gas generator. This temperature is a basic diagnostic parameter use for evaluating the technical state of the turbine engine in operation, and is monitored during engine start-ups, accelerations and decelerations of rotor units, and steady-load states. ABSTRACT The first part of the article is limited to the presentation of the results of diagnostic examination of a threeshaft engine with a separate power turbine, operating in steady-load states. The here presented diagnostic analyses and syntheses based on a simplified mathematical model of thermal and flow processes taking place in the combustion chamber, which was used for deriving the equation describing the average steadystate temperature of the exhaust gas flow at the outlet cross-section of the chamber.
Źródło:
Polish Maritime Research; 2011, 2; 37-43
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part II. Unsteady processes
Autorzy:
Korczewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/260604.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
technical diagnostics
naval turbine engines
exhaust gas temperature
unsteady processes
unstable
Opis:
The second part of the article presents the results of operating diagnostic tests of a two- and three-shaft engine with a separate power turbine during the start-up and acceleration of the rotor units. Attention was paid to key importance of the correctness of operation of the automatic engine load control system, the input for which, among other signals, is the rate of increase of the exhaust gas flow temperature. The article presents sample damages of the engine flow section which resulted from disturbed functioning of this system. The unsteady operation of the compressor during engine acceleration was the source of excessive increase of the exhaust gas temperature behind the combustion chamber and partial burning of the turbine blade tips.
Źródło:
Polish Maritime Research; 2011, 3; 37-42
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part III. Diagnostic and operating tolerances
Autorzy:
Korczewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/260052.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
technical diagnostics
naval turbine engines
exhaust gas temperature
operating and diagnostic tolerances
Opis:
The third part of the article presents a method for detecting failures of the automatic engine control system with the aid of an exhaust gas temperature setter, specially designed and machined for this purpose. It also presents a procedure of identifying the operating tolerances and determining the diagnostic tolerances for the exhaust gas temperature recorded in the naval turbine engine during the start-up and acceleration processes. The diagnostic tolerances were determined using the statistic inference, based on the hypothesis about the normal distribution of the starting exhaust gas temperature dispersion at the initial time of engine operation. The above hypothesis was verified using the non-parametric statistic test ÷2 for examining the consistency of the empirical distribution with the assumed normal distribution. As a result of the examination, satisfactory convergence of the compared distributions was obtained which made the basis for assuming the three-sigma limits of the diagnostic tolerance for the analysed engine control parameter.
Źródło:
Polish Maritime Research; 2011, 4; 49-53
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hybrydowe pomiary geometrii i temperatury pieca obrotowego na potrzeby diagnostyki
Rotary kiln geometry and temperature hybrid measurements for diagnostic purposes
Autorzy:
Zator, S.
Michalski, P.
Lasar, M.
Powiązania:
https://bibliotekanauki.pl/articles/392332.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
piec obrotowy
diagnostyka
geometria
temperatura
skaning laserowy
termowizja
rotary kiln
diagnostics
temperature
laser scanning
thermography
Opis:
W artykule zaprezentowano implementację dwóch technik: skaningu laserowego do odtworzenia geometrii obiektu i termografii do uzyskania rozkładu temperatury na powierzchni pieca obrotowego w cementowni. Geometrię pieca odtworzono korzystając ze skanera laserowego Trimble FX, wykonując pięć sesji pomiarowych z różnych pozycji, aby uzyskać możliwie pełny obraz powierzchni obiektu. Wynikiem pomiarów jest chmura punktów odwzorowująca powierzchnię płaszcza pieca. Pomiary wykonano podczas postoju pieca, tj. planowego remontu. Odtworzony na podstawie chmury punktów model pieca pozwala zaobserwować odcinki cylindryczne, których osie nie pokrywają się z główną osią pieca. Pomiar rozkładu temperatury pieca wykonano w trakcie jego rozruchu kamerą termowizyjną VarioCAM Head. Ponieważ ograniczenia wynikające z kąta widzenia teleobiektywu kamery termowizyjnej nie pozwoliły na ujęcie pieca w całości na pojedynczym termogramie, dlatego – aby otrzymać termogram pojedynczego segmentu pieca – kamerę umieszczono na obrotnicy i wykonano sekwencje pomiarów. Powtarzając pomiary całej szerokości pieca, otrzymano serię termogramów, które następnie połączono ze sobą, uzyskując termogramy o wysokiej rozdzielczości. Przygotowane obrazy zrzutowano na model 3D uzyskany na podstawie skaningu laserowego, co pozwoliło na stworzenie rozkładu temperatury w środowisku wirtualnym, w którym można zdiagnozować stan wymurówki badanego pieca obrotowego z rozdzielczością kilkukrotnie wyższą niż standardowo wykonywane termogramy, z jednoczesnym dostępem do rzeczywistych współrzędnych obserwowanych detali.
This paper presents an implementation of two techniques, laser scanning for the object geometry reconstruction and thermography to obtain the temperature distribution on the surface of the rotary kiln located in the cement plant. Rotary kiln geometry was reconstructed using the FX laser scanner Trimble by taking 5 measurement sessions from various locations to get the full picture of the object surface. The measurement result is a cloud of points mapping the surfaces of the kiln. Measurements were made during a planned renovation, of the kiln. Model reconstructed on the basis of the point cloud allows to observe cylindrical segments, whose axes do not coincide with the major axis of the rotary kiln. Measurement of the temperature distribution on the kiln surface was performed using a thermal imaging camera VarioCam Head. Infrared camera telephoto angle limitations did not allow to capture the whole kiln on a single thermogram, the problem was solved by mounting the camera on the turntable and performed the sequence of measurements to obtain thermograms of the kiln single segment. Repeating the measurements for the entire width of the kiln achieved a series of thermograms, which were then combined together to yield high-resolution thermograms. Such prepared images were cast to the 3D model, which allows to watch the temperature distribution in a virtual environment. It allows to diagnose the state of the rotary kiln lining with a resolution several times higher than the standard thermograms performed with simultaneous access to the actual coordinates of the observed details.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2012, R. 5, nr 9, 9; 171-177
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiparameter approximation model of temperature conditions of marine diiesel generator sets, based on Markov chain Monte Carlo
Autorzy:
Myrhorod, V.
Hvozdeva, I.
Budashko, V.
Powiązania:
https://bibliotekanauki.pl/articles/24201416.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
marine diesel engine
Markov chain Monte Carlo
temperature condition
multi-parameter approximation model
marine diesel generator
markov model
diagnostics
technical diagnostics
Opis:
In the article we propose a multi-parameter approximation model, based on Markov chain Monte Carlo, which describes the relationship between the temperature regime, operating conditions and electromechanical parameters of marine diesel generator sets. The approximation model is constructed on the basis of the analysis of experimental data of the exhaust gases temperature of marine diesel generator sets in their long-term operation. As a statistical model of random processes of temperature deviations from the approximation model, a Markov process model is proposed that takes into account the possible correlation of the initial data. Since the measuring channels of modern diagnostic systems are digital, due to discretization in time and level, the studied processes form a Markov chain, which makes it possible to establish the important features of such processes. The use of approximation models ensures the stationarity conditions and the correctness of the proposed Markov model in the conditions of multi-mode operation of marine diesel generator sets. The proposed multi-parameter approximation model, based on Markov chain Monte Carlo, allows you to take into account random perturbations that lead to a random change in the output coordinates of the diagnostic object. The proposed improvement of the model makes it possible to ensure its adequacy to real processes of changing the parameters of the temperature regimes of marine diesel generator sets. The proposed multi-parameter approximation model, based on Markov chain Monte Carlo, can be used in the systems of technical diagnostics of marine diesel generator sets in order to increase the reliability of diagnostic conclusions.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2022, 16, 4; 779--784
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On possibility of application of InSb-based high-temperature Hall sensors for ITER magnetic diagnostics
O możliwości zastosowania wysokotemperaturowych czujników Halla opartych o InSb w diagnostyce magnetycznej tokamaka ITER
Autorzy:
Jankowski, J.
El-Ahmar, S.
Oszwaldowski, M.
Prokopowicz, R.
Pytel, K.
Powiązania:
https://bibliotekanauki.pl/articles/159884.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
high-temperature
neutron irradiation
Hall sensor
ITER
magnetic diagnostics
Opis:
We report on irradiation experiments of InSb-based Hall samples at two types of neutron spectrums. One with thermal neutrons (natural neutron spectrum of fission reactor) and second with fast neutrons (filtered spectrum). Fluences in both cases reached almost 1018 cm-2 and that led to significant decreasing of electron mobility of samples. In case of thermal neutrons, transmutation process led to increasing of electron concentration of about 2.3×1018 cm-3. For samples irradiated with fast neutrons, twofold effect was observed: increase in electron concentration for samples with low carrier density and decrease in electron concentration for samples with high carrier density. All results raise important issue, that in case of ITER ex-vessel steady state sensors, research at different spectrum of neutrons are necessary.
W artykule przedstawione zostały wyniki badań nad napromieniowaniem neutronami struktur halotronowych bazujących na antymonku indu (InSb). Część próbek została napromieniowana w strumieniu neutronów termicznych (widmo naturalne neutronów reaktora MARIA w Świerku), a pozostałe próbki w strumieniu neutronów prędkich (widmo filtrowane neutronów reaktora). W obu przypadkach dozy neutronów były zbliżone do poziomu 1018 cm-2, doprowadzając do znacznego spadku ruchliwości elektronów w cienkich warstwach InSb. W przypadku napromieniowania neutronami termicznymi zaobserwowano wzrost koncentracji elektronów o wartość ok. 2,3×1018 cm-3, głównie za sprawą transmutacji In -> Sn. Dla próbek napromieniowanych neutronami prędkimi wystąpiły dwa przeciwne efekty: wzrost koncentracji elektronów dla próbek o niskiej początkowej koncentracji elektronów, oraz spadek koncentracji dla próbek o wysokiej początkowej koncentracji elektronów. Wyniki badań wskazują, że w przypadku zastosowania czujników Halla w tokamaku ITER niezbędne jest przeprowadzenie badań w strumieniach neutronów o różnym widmie energetycznym.
Źródło:
Prace Instytutu Elektrotechniki; 2012, 258; 149-156
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies