Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tank system" wg kryterium: Temat


Wyświetlanie 1-31 z 31
Tytuł:
Takagi Sugeno fuzzy expert model based soft fault diagnosis for two tank interacting system
Autorzy:
Manikandan, P.
Geetha, M.
Powiązania:
https://bibliotekanauki.pl/articles/229272.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
extended Kalman filter
fault diagnosis
fuzzy logic
two-tank system
Opis:
The inherent characteristics of fuzzy logic theory make it suitable for fault detection and diagnosis (FDI). Fault detection can benefit from nonlinear fuzzy modeling and fault diagnosis can profit from a transparent reasoning system, which can embed operator experience, but also learn from experimental and/or simulation data. Thus, fuzzy logic-based diagnostic is advantageous since it allows the incorporation of a-priori knowledge and lets the user understand the inference of the system. In this paper, the successful use of a fuzzy FDI based system, based on dynamic fuzzy models for fault detection and diagnosis of an industrial two tank system is presented. The plant data is used for the design and validation of the fuzzy FDI system. The validation results show the effectiveness of this approach.
Źródło:
Archives of Control Sciences; 2014, 24, 3; 271-287
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A comparison between integer order and non-integer order controllers applied to a water levelling system
Porównanie regulatorów całkowitego i niecałkowitego rzędu do sterowania poziomem wody w systemie zbiorników
Autorzy:
Kania, B.
Dziwiński, T.
Bauer, W.
Zagórowska, M.
Baranowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/282136.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
non-integer order systems
PID
optimization
tank system
rachunek różniczkowy niecałkowitego rzędu
układ zbiorników
Opis:
The purpose of this paper is to compare responses of two systems with two types of controllers: integer order PI controller and non-integer order PI controller (FOPI). Comparison is made on the grounds of time domain responses of waters level in tank. In order to design both of the controllers, numerical model is established and described. Synthesis method with use of simulated annealing optimisation method is developed for each controller. In order to do a correct comparison, the two control systems have the same designing parameters. Matlab/Simulink environment and numerical model are used to do the computing. Numerically designed controllers are verified experimentally with tank system. The obtained results show that using non-integer order PIl controller instead of a ”traditional” PI controller in simple integrating systems is useless.
W artykule porównano odpowiedzi układów z dwoma regulatorami: typu PI oraz typu PI niecałkowitego rzędu. W celu syntezy regulatorów, stworzono i opisano model numeryczny, a następnie wykorzystano metodę symulowanego wyzarzania do znalezienia optymalnych parametrów. Tak zaprojektowane regulatory zostały przetestowane na rzeczywistym zbiorniku. W rezultacie okazało się, że zastosowanie regulatora niecałkowitoliczbowego rzędu do układu całkującego nie jest konieczne. Obliczenia były prowadzone w środowisko Matlab/Simulink.
Źródło:
Automatyka / Automatics; 2014, 18, 2; 71-82
1429-3447
2353-0952
Pojawia się w:
Automatyka / Automatics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nieczystości płynne ze zbiorników bezodpływowych jako źródło zanieczyszczeń mikrobiologicznych wód podziemnych
Liquid waste from septic tanks as a source of microbiological pollution of groundwater
Autorzy:
Nowak, R.
Imperowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/400687.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
kanalizacja bezodpływowa
zanieczyszczenia mikrobiologiczne
jakość wód podziemnych
sewage holding tank system
microbiological pollutions
groundwater quality
Opis:
W Polsce ogromnym problemem jest zanieczyszczenie środowiska gruntowo-wodnego przez nieczystości płynne, pochodzące ze zbiorników bezodpływowych. Dotyczy to szczególnie terenów wiejskich. Negatywne zmiany stwierdzane są zarówno w sąsiedztwie nieszczelnych zbiorników, z których zagęszczone i zagniłe ścieki infiltrują do gruntu, jak i w wodach powierzchniowych i gruntach ornych, do których trafiają nieczystości z opróżnianych zbiorników. W pracy, na przykładzie wybranej gminy, przedstawiono skalę występowania procederu niekontrolowanego odprowadzania ścieków bytowych do środowiska. Zaprezentowane dane porównano z wynikami oceny jakościowej wód podziemnych, ujmowanych w tej samej gminie do celów wodociągowych. W znaczącej części studni woda nie była bezpieczna pod względem sanitarnym, bowiem stwierdzono w niej obecność m.in. zanieczyszczeń mikrobiologicznych. Wśród oznaczonych mikroorganizmów dominowały organizmy wskaźnikowe zanieczyszczenia wód ściekami bytowymi. Problemy z jakością wody zostały odnotowane na ujęciach, zlokalizowanych w pobliżu posesji, wyposażonych w zbiorniki bezodpływowe lub w miejscach, do których w niekontrolowany sposób trafiały ścieki z opróżnianych zbiorników. W ten sposób wykazano, że istnieje związek między niewłaściwie prowadzoną gospodarką ściekową a jakością wód podziemnych, ujmowanych do celów wodociągowych.
Pollution of soil and water environment by liquid waste originating from septic tanks is a huge problem in Poland. This applies especially to rural areas. Negative changes are observed both in the vicinity of the leaking tanks, from which concentrated and rotten sewage infiltrates into the ground, and in surface water as well as arable land, to which impurities from the emptied tanks are discharged. The paper presents the scale of the practice of uncontrolled domestic sewage discharge into the environment on the example of selected municipality. Presented data were compared with the results of the qualitative assessment of groundwater, which is collected in the same municipality for waterworks. In a significant number of wells, water was not safe in sanitary terms, as the presence of microbiological contamination was recorded. Among determined microorganisms, the indicator organisms of domestic waste pollution prevailed. Water quality problems have been reported at intake points located near the properties equipped with septic tanks or in places, to which sewage from emptying septic tanks were transferred in an uncontrolled manner. In this way it has been shown that there is a relationship between improperly maintained wastewater management and groundwater quality collected for the purpose of water supply.
Źródło:
Inżynieria Ekologiczna; 2016, 47; 60-67
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of Dynamic Neural Networks With Application to Observer-Based Fault Detection and Izolation
Autorzy:
Marcu, T.
Mirea, L.
Frank, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/908286.pdf
Data publikacji:
1999
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wykrywanie błędu
sieć neuronowa dynamiczna
identyfikacja systemu
fault diagnosis
dynamic neural networks
system identification
static neural classifiers
three-tank system
Opis:
The paper suggests a neural-network approach to the design of robust fault diagnosis systems. The main emphasis is placed upon the development of neural observer schemes. They are built based on dynamic neural networks, i.e. dynamic multi-layer perceptrons with mixed structure. The goal is to achieve an adequate approximation of process outputs for known classes of the process behaviour. The obtained symptoms are then classified by means of static artificial nets. Appropriate decision mechanisms are designed for each type of observer schemes. An application to a laboratory process is included. It refers to component and instrument fault detection and isolation in a three-tank system.
Źródło:
International Journal of Applied Mathematics and Computer Science; 1999, 9, 3; 547-570
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obserwatory o nieznanym wejściu w diagnostyce układu dwóch zbiorników
Unknown input observers in fault diagnosis of a two-tank system
Autorzy:
Pawłowska, M.
Witczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/327376.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
obserwatory o nieznanym wejściu
układ dwóch zbiorników
diagnostyka uszkodzeń
unknown input observers
two-tank system
fault diagnosis
Opis:
Przedmiotem pracy jest zaproponowanie systemu detekcji i lokalizacji uszkodzeń układu dwóch zbiorników z zastosowaniem rozszerzonych obserwatorów o nieznanym wejściu. W szczególności, pokazuje się jak rozwiązać problem lokalizacji uszkodzeń z zastosowaniem banku rozszerzonych obserwatorów o nieznanym wejściu, gdzie każdy obserwator wrażliwy jest na wszystkie uszkodzenia oprócz jednego. W końcowej części pracy przedstawia się rezultaty symulacji komputerowych potwierdzające skuteczność proponowanego rozwiązania.
The main objective of the paper is to propose a fault detection and isolation system for a two-tank system using extended unknown input observers. In particular, it is shown how to solve the fault isolation problem with a bank of extended unknown input observers where each of the observers is sensitive to all but one faults. The final part of the paper presents the computer simulation results that confirm the effectiveness of the proposed approach.
Źródło:
Diagnostyka; 2006, 3(39); 109-116
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Sensitivity Theory to Fuzzy Logic Based Fdi
Autorzy:
Dalton, T.
Klotzek, P.
Frank, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/908289.pdf
Data publikacji:
1999
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
system rozmyty
wyodrębnienie i wykrycie błędu
teoria wrażliwości
analiza reszt
fuzzy systems
fault detection and isolation
fuzzy inference
sensitivity theory
residual analysis
two-tank system
Opis:
This paper describes an application of sensitivity theory to the analysis of a certain class of fuzzy systems which can be used for fault detection and isolation (FDI). The work is divided into three main tasks. The first is the mathematical representation of some class of fuzzy systems. This is followed by an application of sensitivity theory to fuzzy systems based on the approach detailed in the first part. Finally, this method is applied to a fuzzy fault diagnosis scheme for the two-tank system, and the results compared with those achieved by the application of sensitivity theory to a non-fuzzy diagnosis scheme for the same system. Simulation results for the fuzzy and non-fuzzy fault diagnosis schemes are presented, which verify the results obtained via the application of sensitivity theory.
Źródło:
International Journal of Applied Mathematics and Computer Science; 1999, 9, 3; 619-636
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic Neural Networks for Process Modelling in Fault Detection and Isolation Systems
Autorzy:
Korbicz, J.
Patan, K.
Obuchowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/908291.pdf
Data publikacji:
1999
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wykrywanie błędu
sieć neuronowa dynamiczna
modelowanie nieliniowe
algorytm inteligentny
fault detection
dynamic neural networks
non-linear modelling
learning algorithms
FL-classifier
two-tank system
Opis:
A fault diagnosis scheme for unknown nonlinear dynamic systems with modules of residual generation and residual evaluation is considered. Main emphasis is placed upon designing a bank of neural networks with dynamic neurons that model a system diagnosed at normal and faulty operating points.To improve the quality of neural modelling, two optimization problems are included in the construction of such dynamic networks: searching for an optimal network architecture and the network training algorithm. To find a good solution, the effective well-known cascade-correlation algorithm is adapted here. The residuals generated by a bank of neural models are then evaluated by means of pattern classification. To illustrate the effectiveness of our approach, two applications are presented: a neural model of Narendra's system and a fault detection and identification system for the two-tank process.
Źródło:
International Journal of Applied Mathematics and Computer Science; 1999, 9, 3; 519-546
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie liniowych nierówności macierzowych do syntezy sterowania poziomem wody w układzie kaskadowym dwóch zbiorników
Design of water tank level cascade control system via LMI approach
Autorzy:
Rybczak, M.
Tomera, M.
Powiązania:
https://bibliotekanauki.pl/articles/266317.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
regulator stanu
liniowe nierówności macierzowe
metoda lokowania biegunów
układ kaskadowy zbiorników
state feedback controller
linear matrix inequalities
pole placement method
tank cascade system
Opis:
Referat zawiera metodykę doboru parametrów regulatora stanu z wykorzystaniem liniowych nierówności macierzowych (ang. LMI - Linear Matrix Inequalities) metodą lokowania biegunów. W pracy zdefiniowano warunki rozmieszczenia biegunów w lewej półpłaszczyźnie zmiennej zespolonej s i wyznaczono obszary dopuszczalnych położeń biegunów. Na potrzeby rozważanej, liniowej metody projektowania dokonano linearyzacji modelu matematycznego obiektu w wybranym punkcie pracy. Zaprojektowany regulator stanu zastosowany został do sterowania obiektem rzeczywistym, którym był układ kaskadowy dwóch zbiorników. W referacie przedstawione zostały zarówno wyniki badań symulacyjnych jak i badań eksperymentalnych przeprowadzonych na obiekcie rzeczywistym.
The paper describes a state feedback controller design by pole placement method using Linear Matrix Inequalities (LMI) approach. Conditions of pole placement constraints in a left half plane of the complex plane s are defined and allowable region for poles of the closed-loop control system are determined. For the purpose of using the linear design method, the mathematical model of controlled plant was linearized at a selected operating point. The designed state feedback controller was used for controlling the water level in a two-tank cascade system. The paper presents results of both computer simulations and real-time experiments.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 57; 109-116
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model of stabilising and tracking control system in main battle TANK5
Autorzy:
Papliński, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/243617.pdf
Data publikacji:
2008
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
main battle tank
stabilising and tracking control system
tank gun stabiliser
Opis:
The tank gun stabiliser is an electro-hydraulic control system which makes possible aiming at a target, tracking of a target and stabilise of a given gun angular position. The two-axial stabiliser consists of two separate control systems to stabilise the gun in elevation and the turret (with gun) in azimuth. The aim of researches was to identify all functional blocks of tank gun elevation stabiliser 2E28M (installed in tanks T-72 and PT-91 Twardy) in order to build mathematical model of the system. After detailed analysis of construction and work principles, schematic of 2E28M hydro-mechanical powered mounting, showing number of energy conversion were worked out. Stabiliser has been divided into appropriate functional parts and functional scheme of investigated system were build. Afterwards, static and dynamic characteristics of functional parts of the system were determined. On the basis of obtained characteristics and based on the knowledge about the system feedbacks, structural scheme and mathematical model of foregoing stabiliser were derived. On the basis of the mathematical model, the algorithm and the computer program were worked - out. Making use of the Matlab-Simulink program, one worked-up the scheme for numerical computation. The mathematical model and its numerical implementation have been experimentally verified.
Źródło:
Journal of KONES; 2008, 15, 3; 425-431
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model of stabilising and tracking control system in main battle tank
Autorzy:
Borkowski, W.
Hryciów, Z.
Papliński, K. M.
Rybak, P.
Wysocki, J.
Powiązania:
https://bibliotekanauki.pl/articles/244961.pdf
Data publikacji:
2015
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
main battle tank
stabilising and tracking control system
tank gun stabiliser
Opis:
The aim of this researches was to identify all functional blocks of tank gun stabiliser 2E28M (installed in tanks T-72 and PT-91 Twardy) in order to build mathematical model of the system. The tank gun stabiliser is an electro-hydraulic control system, which makes possible aiming at a target, tracking of a target and stabilise of a given gun and turret angular position. The two-axial stabiliser consists of two separate control systems to stabilise the gun in elevation and the turret (with gun) in azimuth. After detailed analysis of construction and work principles, functional schemes of investigated systems were build. Afterwards, static and dynamic characteristics of functional parts of the system were determined. Because of obtained characteristics and based on the knowledge about the system feedbacks, structural schemes and mathematical models of foregoing stabiliser were derived. The results of numerical computations were compared with the existing results of experimental tests carried-out on a real plant. The results of experimental and model simulation investigations showed that the mathematical model and its numerical implementation were correctly developed.
Źródło:
Journal of KONES; 2015, 22, 4; 43-52
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie regulatorów neuronowego i rozmytego do sterowania poziomem wody w układzie kaskadowym dwóch zbiorników
Use of neural and fuzzy controllers to control water level in two-tank cascade system
Autorzy:
Tomera, M.
Kasprowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/223272.pdf
Data publikacji:
2012
Wydawca:
Akademia Marynarki Wojennej. Wydział Dowodzenia i Operacji Morskich
Tematy:
sterowanie rozmyte
sterowanie neuronowe
radialne funkcje bazowe
układ kaskadowy dwóch zbiorników
mikrokontroler sygnałowy
fuzzy control
neural control
radial base functions
two-tank cascade system
digital signal processor
Opis:
W artykule przedstawione zostały regulatory zbudowane w oparciu o metody sztucznej inteligencji. Klasyczny regulator PID zastosowany do sterowania poziomem wody w układzie kaskadowym dwóch zbiorników zastąpiony został regulatorami rozmytym i neuronowym. Struktura regulatora rozmytego działającego w oparciu o logikę rozmytą wzorowana była na klasycznym liniowym regulatorze PID. Regulator neuronowy jest równoważnikiem regulatora rozmytego zbudowanym w oparciu o sztuczną sieć neuronową o radialnych funkcjach bazowych (RBF). Wstępne badania układów sterowania z rozważanymi regulatorami wykonane zostały w środowisku obliczeniowym MATLAB/Simulink z użyciem modeli symulacyjnych. Badania docelowe przeprowadzone były w układzie fizycznym, w którym algorytmy sterowania zaprogramowane zostały w mikrokontrolerze sygnałowym TMS320F28335, wykorzystanym do automatycznego sterowania poziomem wody w dolnym zbiorniku. Przy porównaniu uzyskanych wyników pod uwagę wzięty został również klasyczny regulator liniowy PID.
This paper presents controllers built according to the methods of artificial intelligence. The classic PID controller used to control the level of water in a cascade of two tanks was replaced with regulators: fuzzy and neural. The structure of fuzzy controller acting on the fuzzy logic was base on a classical linear PID controller. A neural controller is equivalent to a fuzzy controller based on artificial neural network having radial base functions (RBF). Preliminary testing of control systems with the controllers considered were made in computing simulation MATLAB/Simulink. The final investigations were conducted in the target physical system in which the control algorithms were programmed in the signal processor TMS320F28335, used for automatic control of the water level in the lower tank. In comparing the results obtained the classic linear PID controller was considered.
Źródło:
Zeszyty Naukowe Akademii Marynarki Wojennej; 2012, R. 53 nr 3 (190), 3 (190); 123-138
0860-889X
Pojawia się w:
Zeszyty Naukowe Akademii Marynarki Wojennej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model testing of stabilising and tracking control system in main battle tank
Autorzy:
Papliński, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/242585.pdf
Data publikacji:
2015
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
main battle tank
stabilising and tracking control system
tank gun stabiliser
model testing
Opis:
The subject of discussion is a tank gun stabiliser (in azimuth and elevation). For the investigation of the considered control system one applied a method of computer simulations. The mathematical model and its numerical implementation were experimentally verified. The results of experimental and model simulation investigations showed that the mathematical model and its numerical implementation were worked-out correctly. Using the verified mathematical model of the system, the simulation investigations of the influence of regulation potentiometers settlings on stabilisation exactness and transient processes quality were carried-out. The possibilities of improving performance characteristics of the stabiliser via altering of feedback’s gain coefficients as well as the influence of disturbing inputs amplitude and frequency (propagated from the hull on the gun and turret) on stabilisation exactness of a given position were also analysed. The presented technique is quite general and may be applied to any type of vehicle to study dynamic effects of several rigid bodies, which move relative to each other (when displacements are small) and are connected by constraint equations.
Źródło:
Journal of KONES; 2015, 22, 4; 221-226
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Condition of Sanitary Infrastructure in the Parczew District and the Need for its Development
Autorzy:
Micek, A.
Marzec, M.
Jóźwiakowska, K.
Pochwatka, P.
Powiązania:
https://bibliotekanauki.pl/articles/123430.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sanitary infrastructure
commune
water supply system
sewerage system
wastewater treatment plant
septic tank
Opis:
The aim of this paper is to present the current state and the need for development of sanitary infrastructure in the communes of Parczew District, in Lublin Voivodeship. Parczew District encompasses seven communes: Parczew, Dębowa Kłoda, Jabłoń, Milanów, Podedwórze, Siemień, and Sosnowica. The present paper uses the data from the surveys conducted in these communes in 2016. On average, 88% of the population used the water supply system in the communes surveyed, while 48% of the inhabitants were connected to a sewerage system. Parczew District had 12 collective mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3/d. The households which were not connected to the sewerage network discharged the wastewater mainly to non-return tanks. In the communes surveyed, 1,115 households had domestic wastewater treatment plants. All of them were systems with infiltration drainage, which do not ensure high efficiency of removing pollutions and may even contribute to the degradation of the groundwater quality. In order to solve the existing problems of sewage and water management in the communes of Parczew District, it is necessary to further develop the collective sewerage systems and equip the areas which have a dispersed development layout with highly efficient domestic treatment plants, such as constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 107-115
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The State of Water and Wastewater Management in the Municipalities of the Roztocze National Park
Autorzy:
Jóźwiakowski, K.
Podbrożna, D.
Kopczacka, K.
Jaguś, M.
Marzec, M.
Listosz, A.
Pochwatka, P.
Kowalczyk-Juśko, A.
Malik, A.
Powiązania:
https://bibliotekanauki.pl/articles/123660.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
municipality
water supply
sewage system
sewage treatment plant
septic tank
national park
Opis:
The aim of this paper is to present the current state of water and sewage management in the communes where the Roztocze National Park (RNP) is located. The park is located in Lubelskie voivodship, in the territory of four communes: Zamość, Zwierzyniec, Adamów and Józefów, while its buffer zone is located in the communes of Krasnobród, Tereszpol and Szczebrzeszyn. The paper uses data from surveys conducted in these municipalities in 2016. On average, 68.9% of the population used the water supply system in the municipalities surveyed, while 33.4% of the inhabitants had the possibility of discharging sewage to the sewerage system. In the area of the communes, there are 10 collective, mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3·d-1. The households which are not connected to the sewage network discharge wastewater mainly to non-return tanks. Four out of the seven surveyed communities had 64 domestic sewage treatment plants, including 60 systems with infiltration drainage, which do not ensure high efficiency of removing pollution and may even contribute to the degradation of groundwater quality. In order to solve the existing problems in the area of sewage and water management occurring in the communes where the Roztocze National Park is located, it is necessary to further develop collective sewage systems and equip the areas with dispersed buildings with highly efficient, residential sewage treatment plants, e.g. constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 255-262
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zbiorniki o ścianie prefabrykowanej z klejonymi pionowymi stykami sprężone zewnętrznymi cięgnami bez przyczepności
Precast concrete tank wall with mortar cementing vertical joints prestressed with external unbonded tendons
Autorzy:
Seruga, A.
Faustmann, D.
Szydłowski, R.
Zych, M.
Powiązania:
https://bibliotekanauki.pl/articles/160745.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
zbiornik prefabrykowany
zbiornik żelbetowy
system MULEBY
spoina klejona
cięgno bez przyczepności
awaria
analiza przyczyn
prefabricated tank
reinforced concrete tank
MULEBY system
bonded joint
unbonded tendon
failure
causes analysis
Opis:
W pracy przedstawiono rozwiązanie konstrukcyjne zbiorników o ścianie z elementów prefabrykowanych łączonych pionowymi stykami pionowymi. Ściana zbiornika jest sprężona zewnętrznymi obwodowymi cięgnami bez przyczepności przeciąganymi przez otwory w żeberku pionowym. Przedstawiono przyczyny zawalenia się zbiornika wykonanego z 61 elementów prefabrykowanych. W pracy podano warunki realizacji takich zbiorników w przyszłości.
In the paper the precast concrete tank wall solution with mortar cementing vertical joints are presented. The tank wall is post-tensioned by exterior unbonded circumferential tendons, threaded through holes in the ribbs along the vertical wall joints. The reasons of 61 precast concrete elements tank wall collapse after 5 days from final prestressing were discussed. In the paper conditions of further construction this solution are presented.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 4, 4; 58-63
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of three control algorithms for an averaging tank with variable filling
Autorzy:
Kolankowski, Michał
Piotrowski, Robert
Powiązania:
https://bibliotekanauki.pl/articles/2105996.pdf
Data publikacji:
2022
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
control system
fuzzy control system
integral control system
LQR
mathematical model
PID control system
state feedback controller
tank with variable filling
Opis:
An averaging tank with variable filling is a nonlinear multidimensional system and can thus be considered a complex control system. General control objectives of such object include ensuring stability, zero steady-state error, and achieving simultaneously shortest possible settling time and minimal overshoot. The main purpose of this research work was the modeling and synthesis of three control systems for an averaging tank. In order to achieve the intended purpose, in the first step, a mathematical model of the control system was derived. The model was adapted to the form required to design two out of three planned control systems by linearization and reduction of its dimensions, resulting in two system variants. A multivariable proportional-integral-derivative (PID) control system for the averaging tank was developed using optimization for tuning PID controllers. State feedback and output feedback with an integral action control system for the considered control system was designed using a linear-quadratic regulator (LQR) and optimization of weights. A fuzzy control system was designed using the Mamdani inference system. The developed control systems were tested using theMATLAB environment. Finally, the simulation results for each control algorithm (and their variants) were compared and their performance was assessed, as well as the effects of optimization in the case of PID and integral control (IC) systems.
Źródło:
Acta Mechanica et Automatica; 2022, 16, 2; 136--150
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and experiment of low-pressure gas supply system for dual fuel engine
Autorzy:
Gu, Xiaoyong
Jiang, Guohe
Guo, Zhenghua
Ding, Shangzhi
Powiązania:
https://bibliotekanauki.pl/articles/260121.pdf
Data publikacji:
2020
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
gas supply system
dual fuel engine
spiral-wound heat exchanger
buffer tank
Opis:
A low-pressure gas supply system for dual fuel engines was designed to transport liquid natural gas from a storage tank to a dual fuel engine and gasify it during transportation. The heat exchange area and pressure drop in the spiral- wound heat exchanger, the volume of the buffer tank and the pressure drop in the pipeline of the gas supply system were calculated by programming using Python. Experiments were carried out during the proces of starting and running the dual fuel engine using this gas supply system. Experimental data show that the gas supply system can supply gas stably during the process and ensure the stable operation of the dual fuel engine. The effects of the parameters of natural gas and ethylene glycol solution on the heat exchange area of the spiralwound heat exchanger and the volume of the buffer tank in the gas supply system were studied. The results show that the heat exchange area calculated according to pure methane can adapt to the case of non-pure methane. The temperature difference between natural gas and ethylene glycol solution should be increased in order to reduce the heat exchange area. The heat exchange area selected according to the high pressure of natural gas can adapt to the low pressure of natural gas. The volume of the buffer tank should be selected according to the situation of the minimum methane content to adapt to the situation of high methane content. The main influencing factor in selecting the volume of the buffer tank is the natural gas flow. The results can provide guidance for the design of the gas supply system for dual fuel engines.
Źródło:
Polish Maritime Research; 2020, 2; 76-84
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Udoskonalone sposoby akumulacji i rozdziału ciepła w instalacjach grzewczych
Improved methods of accumulation and distribution of heat in the heating systems
Autorzy:
Naskręt, L.
Powiązania:
https://bibliotekanauki.pl/articles/1819775.pdf
Data publikacji:
2009
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
instalacja grzewcza
rozdział ciepła
akumulacja
akumulator warstwowy
heating system
distribution of heat
accumulation
layerd buffer tank
Opis:
Oszczędność energii cieplnej jest istotnym elementem strategii współczesnego budownictwa. Poszukiwanie coraz sprawniejszych i bardziej wydajnych układów cieplnych do zastosowania w budynkach o różnym przeznaczeniu, stymuluje ciągły rozwój branży ciepłowniczej. Jednym z najbardziej skutecznych kierunków opracowań naukowo-technicznych jest doskonalenie sposobów akumulacji i rozdziału ciepła [1, 5, 6]. Zagadnienie to szczególnie komplikuje się w przypadku kojarzenia zróżnicowanych, pod względem temperatury i mocy, obiegów dostarczających energię i obiegów odbiorczych w ramach jednego, zespolonego układu cieplnego[4]. Niezgodności i różnice w pracy tych obiegów kreują zjawiska, które można sklasyfikować w następujący sposób: . brak równowagi hydraulicznej i ostre sprzeczności współpracujących ze sobą obiegów; ujawnione podczas eksploatacji przewymiarowanie lub niedowymiarowanie źródła ciepła; zwiększoną częstotliwość tzw. "taktowania" (włączenia-wyłączenia, zmiany stopni mocy), kotła lub węzła cieplnego, a także poszczególnych siłowników urządzeń automatyki, skutkiem czego staje się obniżona sprawność układu, a w przypadku kotła również zwiększenie emisji substancji szkodliwych; ograniczoną zdolność wykorzystania i regulacji nadmiaru ciepła (np. kocioł na paliwo stałe; kominek); brak możliwości kojarzenia energii z różnych źródeł, o różnym potencjale energetycznym i przeznaczeniu jej do realizacji procesów grzewczych lub technologicznych założonych w obiekcie; niewykorzystanie energii strumienia powrotnego instalacji odbiorczej przy niedostatecznym rozbiorze ciepła; zwiększony czas rozruchu źródła ciepła i instalacji; wydłużoną reakcję źródła ciepła na zmieniające się parametry czynnika,zapotrzebowanie na moc w instalacji i warunki termiczne otoczenia; zmniejszenie efektywności energetycznej i ekonomicznej systemu Skutecznym rozwiązaniem w takich sytuacjach jest dynamiczne oddzielenie obiegów zasilających i instalacyjnych za pomocą rozdzielacza hydraulicznego oraz termodynamicznie uzasadnione zwiększenie pojemności zładu grzewczego w postaci akumulatora ciepła, o dokładnie określonej objętości, działającego według zasady uwarstwienia [2, 7]. Cały ten kierunek ma jeszcze sporo niewykorzystanych możliwości.
Saving the heat energy is an important element of the strategy of modern construction. The search for more efficient and more productive thermal systems for use in buildings for different purposes stimulates the continuous development of heating industry (Fig. 2, 3, 4). One of the most effective lines of such operations is improvement of the accumulation and distribution of heat (Fig.1). The issue is especially complicated in the case of associating different (in terms of temperature and power) energy supply and receiving flow section in a whole integrated heating system (Fig. 3). Effective solution in such situations is a dynamic separation of power supply and installation circuits using a hydraulic splitter and reasonable thermodynamic increase of heat transfer medium volume in heating system in the form of heat accumulator, a well-defined volume, acting according to layering rules (Fig. 4). Universal tool to solve this problem according to the authors is presented in the paper the extensive application of the principles of layered heat buffer tanks (Fig. 5). Advantages of application of improved version of stratified heat accumulators are following: decrease of size of computational power of installed main heat source; significant decrease of consumption of thermal energy in the exploited object; significant increase of thermal efficiency of the whole heating installation; possibility of association of heat sources with different energetic potential, including return streams of heating medium with inflated temperature of recycle; appeasement of hydraulic and thermodynamical incompatibilities during work of the individual circulations of heating installations; constant and long term comparable decreasing of costs of purchase of energy, at comparatively small investment outlays, which are the cost of accumulator, additional return mains, units of steering and measurement and necessary labour; achievement of ecological effect, by decrease power of heat source or sources, limitation the number of their power-ups and changes of the power stages and the possibility of association with the renewable sources of heat.
Źródło:
Rocznik Ochrona Środowiska; 2009, Tom 11; 555-570
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Condition of the Sanitary Infrastructure in the Ryki District in Poland and the Need for its Development
Autorzy:
Jóźwiakowska, Karolina
Micek, Agnieszka
Kanios, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1839635.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
district
septic tank
household wastewater treatment plants
collective wastewater treatment plants
water supply network
sewage system
Opis:
The aim of this paper was to present the current state and the need for development of the sanitary infrastructure in the communes of the Ryki District located in the Lublin Voivodeship. The Ryki District encompasses 1 urban Commune – Dęblin, 1 urban-rural Commune – Ryki and 4 rural communes: Kłoczew, Nowodwór, Stężyca and Ułęż. The paper is based on the data from the surveys conducted in all the afore-mentioned communes in 2016. In the whole district on average 71.3% of the population used the water supply network, while 42% of the inhabitants were able to discharge wastewater to the sewage system. Within the area of the Ryki District, 5 collective wastewater treatment plants with a capacity exceeding 5 m3/d functioned in 2016. The households which were not connected to the sewage network discharged wastewater mainly to non-return tanks. About 440 household sewage treatment plants were found in the surveyed communes. The overwhelming majority of such small objects in the discussed district were activated sludge systems (92%). The research carried out in 2016 proved a strong need to develop the current state of the sanitary infrastructure in the Ryki District. A particular emphasis should be placed on the wastewater management by connecting the inhabitants of urban areas to a joint sewage disposal system. Ecological awareness must be raised so as to encourage people to invest in household wastewater treatment plants, which should be used in the areas with scattered development.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 256-264
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Condition of the Sanitary Infrastructure in the Bialski District in Poland and the Need for its Development
Autorzy:
Jóźwiakowska, Karolina
Marzec, Michał
Powiązania:
https://bibliotekanauki.pl/articles/124925.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
district
septic tank
household wastewater treatment plants
collective wastewater treatment plants
water supply network
sewerage system
Opis:
The aim of this paper was to present the current state and the need for development of the sanitary infrastructure in the communes of the Bialski District located in the Lublin Voivodeship. The Bialski District encompasses 2 urban communes: Miedzyrzec Podlaski and Terespol and 17 rural communes: Biała Podlaska, Drelów, Janów Podlaski, Kodeń, Konstantynów, Leśna Podlaska, Łomazy, Międzyrzec Podlaski, Piszcząc, Rokitno, Rossosz, Sławatycze, Sosnówka, Terespol, Tuczna, Wisznice and Zalesie. The present paper uses the data from the surveys conducted in these communes in 2016. On average, 79.2% of the population used the water supply system in the surveyed communes, while 39.4% of the inhabitants had the possibility of discharging wastewater to the sewerage system. In the area of the communes, there were 20 collective, mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3/d. The households which were not connected to the wastewater network, discharged wastewater mainly to non-return tanks. In the surveyed communes, there were 4437 household wastewater treatment plants. Most of them (above 80%) were the systems with infiltration drainage, which do not ensure high efficiency of pollutants removal and may even contribute to the degradation of the groundwater quality. In order to solve the existing problems of wastewater and water management occurring in the communes where the Bialski District is located, it is necessary to further develop collective wastewater systems and equip the areas characterized by dispersed housing with highly efficient household treatment plants, e.g. constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2020, 21, 5; 155-163
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System monitorowania konstrukcji cylindrycznego zbiornika na węgiel
A structural health monitoring system for a cylindrical coal tank
Autorzy:
Hulimka, J.
Sieńko, R.
Powiązania:
https://bibliotekanauki.pl/articles/160680.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
zbiornik na węgiel
konstrukcja monolityczna
awaria
ocena stanu technicznego
system monitorowania
coal tank
monolithic structure
failure
technical condition evaluation
monitoring system
Opis:
Referat opisuje zastosowanie systemu monitorowania konstrukcji (SHM) do oceny stanu wytężenia zbiornika na węgiel znajdującego się w niskim stanie technicznym. Podano sposób prowadzenia monitoringu, typ czujników oraz opisano podstawowe wyniki. Zastosowanie współczesnego narzędzia wspomagającego diagnozę konstrukcji umożliwiło wydłużenie okresu użytkowania zbiornika o kilka lat.
This paper describes the use of a structural health monitoring (SHM) system to evaluate stress in a coal tank being in poor technical condition. The method of monitoring and the type of sensors are presented, and basic results are described. The use of a modern tool assisting structural diagnosis has made it possible to extend the lifetime of the tank by several years.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 4, 4; 146-150
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The implementation of a coefficient diagram method based polynomial controller for a non-linear process with a distributed control system in a chlorine scrubber system
Implementacja wielomianowego regulatora opartego na metodzie diagramu współczynników dla procesu nieliniowego z rozproszonym systemem sterowania w systemie płuczki chloru
Autorzy:
Murugan, T. Maris
Shankar, T.R. Kiruba
Powiązania:
https://bibliotekanauki.pl/articles/2173816.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
chlorination scrubber system
PID controller
distributed control system
DCS
coefficient diagram method
CDM
interacting conical tank
system oczyszczania chloru
regulator PID
rozproszony system sterowania
metoda diagramu współczynników
współpracujący zbiornik stożkowy
Opis:
The seawater desalination process is emerging as a substantial source of fresh water by removing salt and minerals from an infinite supply of seawater effectively. The first stage in a desalination plant is the use of chlorine gas to sterilize the microorganisms in the water. During excess chlorine leakage, an alert is activated, employees are relocated away from the site for a specific period, and dampers will be manually opened. This will cause unsafe working conditions and a waste of time. To overcome this problem, this paper proposes a coefficient diagram method based proportional integral derivative (CDM-PID) control strategy for the tune the control parameter with the distributed control system (DCS) interfaced conical tank. During operation, a 10% NaOH solution is injected into the top of the scrubber column using an ethylene-ter-polymer (ETA) designed distributor to ensure that the solution is evenly distributed across the packing surface. The three control strategies are compared to tune the control parameter with the DCS interfaced conical tank. Instead of the sodium hydroxide tank in the chlorine scrubber system, this work presents the pilot plant of DCS interfaced with two conical tank interacting systems with different liquid level heights. Here, the proposed CDM-PID controller is compared with the standard Ziegler-Nichols (ZN)-ultimate cycling method, and the internal model control (IMC) method. The results demonstrated that the proposed CDM-PID approach is superior to existing approaches in terms of low oscillation, settling period, and high robustness.
Proces odsalania wody morskiej staje się znaczącym źródłem świeżej wody dzięki skutecznemu usuwaniu soli i minerałów z nieskończonych zasobów wody morskiej. Pierwszym etapem w zakładzie odsalania jest użycie chloru gazowego do sterylizacji mikroorganizmów w wodzie. Podczas nadmiernego wycieku chloru zostanie aktywowany alarm, pracownicy zostaną na pewien czas przeniesieni z terenu zakładu, a klapy zostaną ręcznie otwarte. Spowoduje to niebezpieczne warunki pracy i stratę czasu. Aby rozwiązać ten problem, w niniejszym artykule zaproponowano strategię sterowania opartą na metodzie wykresu współczynników proporcjonalno-całkująco-różniczkujących (Coefficient Diagram Method-Proportional Integral Derivative – CDM-PID) w celu dostrojenia parametru sterowania za pomocą zbiornika stożkowego połączonego z rozproszonym systemem sterowania (Distributed Control System – DCS). Podczas pracy do góry płuczki wstrzykuje się 10% roztwór NaOH za pomocą dystrybutora zaprojektowanego z etylenu-ter-polimeru (Ethylene-Ter-Polymer – ETA), aby zapewnić równomierne rozprowadzenie roztworu na powierzchni wypełnienia. Trzy strategie sterowania są porównywane w celu dostrojenia parametru kontrolnego za pomocą zbiornika stożkowego połączonego z DCS. Zamiast zbiornika wodorotlenku sodu w systemie płuczki chloru, w niniejszej pracy przedstawiono Instalację Pilotażową DCS połączoną z dwoma współpracującymi ze sobą stożkowymi układami zbiorników o różnych wysokościach poziomu cieczy. Tutaj, proponowany regulator CDM-PID jest porównywany ze standardową metodą Zieglera-Nicholsa (ZN)-Ultimate Cycling oraz metodą kontroli modelu wewnętrznego (Internal Model Control – IMC). Wyniki pokazały, że proponowane podejście CDM-PID przewyższa istniejące podejścia pod względem niskich oscylacji, okresu osiadania i wysokiej odporności.
Źródło:
Gospodarka Surowcami Mineralnymi; 2022, 38, 4; 231--255
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perspektivnye tekhnologicheskie skhemy ochistnykh sooruzhenijj avtomoek
Perspective flowsheets of cleansing buildings of autowashings
Autorzy:
Nikolenko, I.
Demkov, A.
Manujjlov, M.
Powiązania:
https://bibliotekanauki.pl/articles/76833.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
circulation system
filter
pressure flotation
sewage water
contamination
cleaning
horizontal tank
polypropylene
waste water treatment
motor car washing
Opis:
In the article the problems of cleaning of sewages are considered on cleansing buildings of the motor-car washings. The constructions of the known flowsheets of cleaning of sewages of autowashings are analysed. The on principle new flowsheet of cleaning of sewages of autowashings is offered, which leans against financial viability with the maximal diminishing of capital costs and maximal carrying capacity.
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2013, 15, 5
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Security of Water Supply for Benissa Municipality, Spain Employing the Shannon-Weaver Model
Ocena bezpieczeństwa dostawy wody dla gminy Benissa z wykorzystaniem wskaźnika Shannona-Weavera
Autorzy:
Miazga, Maciej
Królikowska, Jadwiga
Powiązania:
https://bibliotekanauki.pl/articles/1811725.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
diversification
allocation
resources
water supply
tank
distribution
flow
capacity
dywersyfikacja
alokacja
zasoby
system wodny
zbiornik
dystrybucja
przepływ
pojemność
Opis:
This publication is a presentation of the methodology to determine the degree of diversification and allocation of water resources in water supply systems; with a differentiated level of need based on the example of the municipality of Benissa Spain. The article shows a frequency of the changes and factors that affect the functioning of the water supply system. Moreover, its presents the calculation of the diversification indices for the selected water supply system while the methodology offers the possibility of evaluating the diversification of water resources in two parameters according to an adapted form of the Shannon-Weaver index.
Publikacja przedstawia metody wyznaczenia współczynnika dywersyfikacji i alokacji zasobów wodnych dla systemu zbiorowego zapotrzebowania wody cechującego się zróżnicowanym jej zapotrzebowaniem na przykładzie miasta Benissa w Hiszpanii. W pracy przedstawiono obliczenia stopnia dywersyfikacji zasobów wodnych, metodą dwu-parametryczną, wg zaadaptowanego wskaźnika Shannona-Weavera.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 593-604
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja kaskadowego układu regulacji wywoływacza fal basenu modelowego
The modernizing of cascade control system of the wave generator for towing tank
Autorzy:
Drzewiecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/268647.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
regulacja kaskadowa
regulator PID
wywoływacz fal
basen modelowy
cascade closed-loop control system
PID controller
wave generator
towing tank
Opis:
Artykuł opisuje modernizację stanowiska badawczego w Centrum Techniki Okrętowej (CTO) S.A. – głębokowodnego basenu modelowego z płytowym wywoływaczem fal z płytą mocowaną powyżej dna basenu na pojedynczym przegubie. Modernizacja obejmowała zastąpienie oryginalnego analogowego układu regulacji nowoczesnym cyfrowym układem sterowania, opartym na 8-bitowym mikrokontrolerze AVR. Na podstawie dokonanej identyfikacji poprzedniego układu regulacji zrealizowany został nowy, bardziej przyjazny użytkownikowi układ, który – umożliwiając wdrażanie nowych rozwiązań wykorzystujących nowoczesną technikę cyfrową – zapewnia równocześnie oczekiwaną powtarzalność realizacji fal basenowych.
The paper describes the problem of modernizing a test bench – a deepwater towing tank with a wave maker with a rigid flap articulated above channel bed in the Ship Design and Research Centre (Centrum Techniki Okrętowej S.A.). The modernization was based on the replacement of an analog control system from the 1974 by a modern digital control system based on a 8-bit microcontroller AVR. The scope of this paper includes: identification of the analog control system with a measuring system and an actuating system, design of the digital control system based on the identified analog control system, implementation of the digital controller, start-up and checking of the new control system. The new digital control system meets user expectations, offering extended functionality together with required repeatability. The modernizing of the cascade control system was contribution to start of work on the implementations of new solutions using a modern digital technology.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 39-42
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zgoda wodnoprawna – systemy gospodarowania wodą deszczową na terenach mieszkaniowych
Water law agreement (Aquatic consent) – rainwater management systems in residential areas
Autorzy:
Huebner, J.
Powiązania:
https://bibliotekanauki.pl/articles/345444.pdf
Data publikacji:
2018
Wydawca:
Politechnika Krakowska im. Tadeusza Kościuszki. Wydział Architektury. Katedra Kształtowania Środowiska Mieszkaniowego
Tematy:
regulacje prawne
dom mieszkalny
zgoda wodnoprawna
kanalizacja
zbiornik szczelny
law regulations
house
water law agreement
sewage system
tight water tank
Opis:
Systemy gospodarowania wodą deszczową są zależne przede wszystkim od warunków geologicznych, kształtu zlewni i regulacji prawnych. Podstawowym dokumentem koniecznym do uzyskania jest zgoda wodno prawna, które można porównać do budowlanego pozwolenia na eksploatację obiektu. Zakres obowiązków i kompetencji wynikających z tego dokumentu jest bardzo duży. W Ustawie Prawo wodne, podstawowym dokumentem jest zgoda wodno prawna. Jedynie odprowadzanie wód opadowych do zbiorników szczelnych odparowujących nie wymaga postępowania administracyjnego. To znaczy, że rozwiązania polegające na wykorzystaniu wolnych terenów zielonych do retencjonowania wody powinny być poprzedzone uzyskaniem odpowiednich decyzji administracyjnych. Niebezpieczeństwo polega na tym, że nie zawsze takie sprawy są pozytywnie rozpatrywane.
Rainwater management systems are mainly dependant on geological conditions, shape of the catchment and the legal regulations. Basic document at necessary to get before start of construction is water law agreement (aquatic consent). It can be compared to building permit for the operation of the building. The scope of duties and competences resulting from this document is very extensive. In the Water Law Act the basic document is water law agreement (aquatic consent). The only exception is drainage of rainwater in the tight evaporation water tank, which does not require administrative proceedings. It should be proceeded by obtaining the appropriate administrative decisions. The problem is that such cases are not always examined positively.
Źródło:
Środowisko Mieszkaniowe; 2018, 24; 34-41
1731-2442
2543-8700
Pojawia się w:
Środowisko Mieszkaniowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of variable insulating power of a storing tank on energy effects in the conversion system of solar radiation
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/793373.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
solar collector
heat pump
storing tank
insulation
solar radiation
conversion
hybrid system
thermal balance
energy stream
water temperature
daily change
heat balance
analysis
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study of mixing structure in stirred tanks equipped with multiple four-blade rushton impellers
Badanie struktury mieszania w zbiorniku z mieszadłem w systemie wielowirnikowym z czteropłatkowymi wirnikami Rushtona
Autorzy:
Driss, Z.
Karray, S.
Chtourou, W.
Kchaou, H.
Salah Abid, M.
Powiązania:
https://bibliotekanauki.pl/articles/140006.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
system wielowirnikowy z wirnikami Rushtona
cztery łopatki
sześć łopatek
zbiornik z mieszadłem
metoda numeryczna
modelowanie
multiple Rushton impellers
four blades
six blades
stirred tank
numerical method
modelling
Opis:
The effect of multiple Rushton impellers configurations on hydrodynamics and mixing performance in a stirred tank has been investigated. Three configurations defined by one, two and three Rushton impellers are compared. Results issued from our computational fluid dynamics (CFD) code are presented here concerning fields of velocity components and viscous dissipation rate. These results confirm that the multi-impellers systems are necessary to decrease the weaken zones in each stirred tanks. The experimental results developed in this work are compared with our numerical results. The good agreement validates the numerical method.
W pracy badano efekt konfiguracji wielołopatkowych wirników Rushtona na hydrodynamikę i skuteczność mieszania w zbiorniku z mieszadłem. Porównano trzy konfiguracje mieszadła, zdefiniowane przez jeden, dwa lub trzy wirniki Rushtona. W artykule zaprezentowano wyniki, uzyskane przy użyciu własnego oprogramowania do obliczeń dynamiki płynów (CFD), dotyczące składników pól prędkości i szybkości dyssypacji lepkościowej. Wyniki te potwierdzają, że systemy wielowirnikowe są niezbędne dla zmniejszenia stref zubożonych w każdym zbiorniku z mieszadłem. Wyniki eksperymentalne, uzyskane w tej pracy, są porównane z wynikami obliczeń numerycznych. Dobra zgodność wyników potwierdza przydatność metody numerycznej.
Źródło:
Archive of Mechanical Engineering; 2012, LIX, 1; 53-72
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Higieniczna ocena wodociągów okrętowych
Gigienicheskaja ocenka vodoprovodov na sudnakh
Evaluation of water supply on ships from the point of view of sanitation
Autorzy:
Buczkowska, Z.
Dabrowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/875174.pdf
Data publikacji:
1957
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
wodociagi
hydrofory
zbiorniki cisnieniowe
okrety
woda
ocena higieniczna
jakosc sanitarna
badania bakteriologiczne
przepisy sanitarne
water supply system
ship
pressure tank
water
hygienic assessment
sanitary quality
bacteriological research
sanitary regulation
Źródło:
Roczniki Państwowego Zakładu Higieny; 1957, 08, 2
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór obudowy wykopu tymczasowego dla posadowienia zbiornika retencyjnego wód opadowych osiedla Chabrowe Wzgórza w Kowalach
The process of selecting the support of temporary excavations for the purposes of construction of the impounding reservoir in Kowale near Gdańsk
Autorzy:
Kopras, M.
Powiązania:
https://bibliotekanauki.pl/articles/162538.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
Kowale
zbiornik retencyjny
posadowienie
wykop
obudowa wykopu
zarządzanie wodą opadową
kanalizacja deszczowa
zbiornik wód opadowych
Kowale city
retention reservoir
settlement
trench lining
stormwater management
stormwater sewage system
stormwater retention tank
Opis:
W referacie przedstawiono analizę procesu doboru obudowy wykopów tymczasowych w celu budowy zbiornika retencyjnego. Projekt zakładał wybudowanie prefabrykowanego zbiornika żelbetowego pod powierzchnią terenu na głębokości około 5 metrów. W związku z zaistniałą sytuacją, która to wynikała z faktu wybudowania w pierwszej kolejności budynków mieszkalnych, posadowienie tegoż zbiornika nie mogło odbywać się bez zabezpieczenia ścian wykopów. Planowano posadowienie zbiornika poniżej posadowienia fundamentów budynków i w odległości od nich 8 m po każdej ze stron. Ponieważ użycie wibromłotów byłoby ryzykowne dla fundamentów dopiero co wybudowanych budynków, zwrócono się do firmy Kopras z propozycją rozwiązania tegoż zabezpieczenia.
The paper presents the analysis of the process of selecting the support for temporary excavations for the purposes of construction of the impounding reservoir. The design assumed the construction of the prefabricated reinforced concrete tank under ground level at the depth of about 5 metres. Due to the existing situation which resulted from the fact of the need to construct the residential buildings first, the foundations of the impounding reservoir could not be constructed without securing the excavation walls. The planned location of the reservoir near the location of building foundations and in the distance of 8 m at each side was planned. As it was hazardous to use the vibro-hammers for the foundations of the already constructed buildings, Kopras company was requested to present the solution of such protection.
Źródło:
Przegląd Budowlany; 2017, 88, 9; 51-55
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozwiązanie zamknięte fizycznych właściwości statyki prostokątnego wycinka powłoki o kształcie walca kołowego
Closed solution of static physical properties of a rectangular section of shell shape of a circular cylinder
Autorzy:
Misiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/40878.pdf
Data publikacji:
2013
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
powloki kolowe
wycinki prostokatne
wlasciwosci fizyczne
statyka
uklad warunkow brzegowych
teoria powlok
obliczenia
sklepienia dachowe
stropodachy
wielokomorowy zbiornik kolowy
cylinder uzebrowany
circular shell
physical property
statics
boundary condition system
shell theory
calculation
roof vault
flat roof
circular tank
ribbed cylinder
Źródło:
Acta Scientiarum Polonorum. Architectura; 2013, 12, 4
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-31 z 31

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies