Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "szary stopień relacyjny" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Reliability study on non-contact traction power supplysystem based on fuzzy grey relational FTA
Autorzy:
Pei, Yanxia
Li, Xin
Powiązania:
https://bibliotekanauki.pl/articles/1841276.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FTA
grey relational degree
ICPT technology
reliability research
trapezoidal fuzzy number
triangular fuzzy number
szary stopień relacyjny
technologia ICPT
badania wiarygodności
trapezoidalna liczba rozmyta
trójkątna liczba rozmyta
Opis:
The traction power supply system based on Inductively Coupled Power Transfer (ICPT) technology is one of the new traction power supply technologies that will bedeveloped in the future. As the core part of rail transit energy transfer and conversion, thetraction power supply system is not only the critical system for the safe operation of railtransit, but also the main source of its failures, so it is of great significance to study itsreliability. In this paper, the reliability analysis of the non-contact traction power supplysystem based on mobile ICPT technology is carried out using the method of (Fault Tree Analysis) FTA combined with triangular fuzzy theory and grey relational theory. Firstly,the fault tree of the system is established, and the minimum cut sets and structure functionof the fault tree are obtained. Then the triangular fuzzy numbers are introduced to representthe probability of the bottom events, and the fuzzy probability of the top event and the fuzzyimportance of the bottom events are determined, after that, the maximum probability offailure of the top event is obtained. Finally, the grey relational degrees of each minimum cutset are obtained and ranked. Furthermore, in order to prove the correctness of this method,the trapezoidal fuzzy FTA is introduced and compared with it. Both research results showthat the loosely coupled transformer and Insulated Gate Bipolar Transistor (IGBT) moduleare the weak links of the system. The results obtained are consistent and realistic, whichproves the correctness of the method selected in this article.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 253-270
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies