Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "synchronous generators" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Robust microgrids for distribution systems with high solar photovoltaic penetration
Autorzy:
Sampath, Ediriweera W.E.P.
Lidula, N.W.A.
Herath, H. Dayan B.P.
Powiązania:
https://bibliotekanauki.pl/articles/27309941.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
converter
dynamic system
robustness
stability
synchronous generators
Opis:
A microgrid is an appropriate concept for urban areas with high penetration of renewable power generation, which improves the reliability and efficiency of the distribution network at the consumer premises to meet various loads such as domestic, industrial, and agricultural types. Microgrids comprising inverter-based and synchronous generator-based distribution generators can lead to the instability of the system during the islanded mode of operation. This paper presents a study on designing stable microgrids to facilitate higher penetration of solar power generation into a distribution network. A generalized small signal model is derived for a microgrid with static loads, dynamic loads, energy storages, solar photovoltaic (PV) systems, and diesel generators, incorporating the features of dynamic systems. The model is validated by comparing the transient curves given by the model and a transient simulator subjected to step changes. The result shows that full dynamic models of complex systems of microgrids can be built accurately, and the proposed microgrid is stable for all the considered loading situations and solar PV penetration levels according to the small signal stability analysis.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 785--809
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of synchronous generators for the analysis of frequency transients above 1 Hz/s
Autorzy:
Assenkamp, Alf
Powiązania:
https://bibliotekanauki.pl/articles/2135729.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
control system
distributed energy systems
frequency support
generator model
RoCoF
synchronous generators
synchronous machines
Opis:
Large synchronous generators are of high importance for the stability of power systems. They generate the frequency of the system and stabilize it in case of severe grid faults like trips of large in-feeders or loads. In distributed energy systems, in-feed via inverters will replace this generation in large parts. Modern inverters are capable of supporting grid frequency during severe faults by different means on the one hand. On the other hand, higher Rates of Change of Frequency (RoCoF) after incidents need to be accustomed by future systems. To be able to analyse the RoCoF withstand capability of synchronous or induction generators, suitable models need to be developed. Especially the control and excitation system model need enhancements compared to models proposed in standards like IEEE Std 421.5. This paper elaborates on the necessary modelling depth and validates the approach with example results.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 687--700
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generatory synchroniczne jako kompensatory mocy biernej i filtry wyższych harmonicznych
Synchronous Generators Used as Reactive Power Compensators and Higher Harmonics Filters
Autorzy:
Glinka, T.
Powiązania:
https://bibliotekanauki.pl/articles/1368641.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
generatory synchroniczne
kompensacja mocy biernej
filtry wyższych harmonicznych
synchronous generators
reactive power compensation
higher harmonics filters
Opis:
Compensation of inductive reactive power and limiting higher harmonics in power grid voltage is necessary from the viewpoint of costs and existing regulations on electromagnetic compatibility (EMC). Compensation may be carried out by two methods: with synchronous machines or capacitor banks. Higher harmonice in the current are limited using resonance filters of consecutive harmonics (v = 6n } 1, where n = 1, 2, 3 etc.). Higher harmonics filters compensate also inductive reactive power of the fundamental harmonic (ν = 1). Compensation of reactive power, whether done by synchronous machines or capacitor banks, affects higher harmonic content in current fed back into the power grid. The properties of synchronous machines and capacitors used for reactive power compensation and higher harmonics filtration are compared in the paper.
Kompensacja mocy biernej indukcyjnej i ograniczanie wyższych harmonicznych w napięciu sieci jest konieczne ze względu na koszty i obowiązujące rozporządzenia dotyczące kompatybilności elektromagnetycznej. Kompensację mocy biernej można realizować dwoma metodami : maszynami synchronicznymi, bądź baterią kondensatorów. Wyższe harmoniczne prądu ogranicza się stosując filtry rezonansowe kolejnych harmonicznych (v = 6n ± 1, gdzie n = 1, 2, 3 itd.). Filtry wyższych harmonicznych kompensują także moc bierną indukcyjną pierwszej harmonicznej (ν = 1). Kompensacja mocy biernej, zarówno maszynami synchronicznymi, jak i baterią kondensatorów, wpływa na zawartość wyższych harmonicznych prądu generowanego do sieci elektroenergetycznej. W artykule porównano właściwości maszyn synchronicznych i baterii kondensatorów do kompensacji mocy biernej i filtracji wyższych harmonicznych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 51-62
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Paradygmatyczne zasady diagnostyki wirników turbogeneratorów
The principles of technical diagnostics of turbogenerator rotors
Autorzy:
Przyborowski, W.
Drosik, J.
Powiązania:
https://bibliotekanauki.pl/articles/1367642.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
turbogenerator
monitoring
diagnostyka wirnika
czujniki
sygnały diagnostyczne
monitoring, sensors
symptom diagnostic
examinations of rotors of synchronous generators
Opis:
The paper presents the elements of the principles of technical diagnostics of turbogenerator rotors. The problem examined in terms of methodology in terms of the structure of the distribution and types of sensors and principles of symptoms of the technical condition of turbogenerator rotors. Discussed the basic patterns of symptoms depending on the condition and overall assessment of the types of diagnostic signals. Indicated postulated to increase diagnostic instrumentation of rotor and determine the essential attributes and measures of diagnostic signals.
W pracy przedstawiono elementy zasad diagnozowania stanu technicznego wirników turbogeneratorów. Problem rozpatrzono pod względem metodycznym w zakresie struktury rozmieszczenia i rodzajów sensorów oraz zasad analizy symptomów stanu technicznego wirników turbogeneratorów. Omówiono podstawowe wzorce symptomów stanu i ogólne zależności oceny rodzajów sygnałów diagnostycznych. Wskazano postulatywnie na zwiększenie oprzyrządowania diagnostycznego wirnika i określania podstawowych atrybutów i miar sygnałów diagnostycznych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 3, 107; 107-114
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza wybranych parametrów prądnic synchronicznych w wykonaniu lądowym i morskim
Comparative Analysis of Selected Parameters of Synchronous Generators Applied in Land and Marine Electrical Power Systems
Autorzy:
Kostyszyn, R.
Mindykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1368671.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
parametry prądnic synchronicznych
lądowe i morskie systemy elektroenergetyczne
analiza porównawcza
parameters of synchronous generators
land and marine electrical power systems
comparative analysis
Opis:
In this paper the fundamental differences in the operation process of synchronous generators in the land and marine electrical power systems are presented. A basic information concerning the ways of defining of synchronous generator reactances are described and comparison of longitudinal reactance values of selected generators used under land and marine conditions are carried out. Formulated final conclusions are referred to the current literature data in the discussed matter.
W artykule przedstawiono podstawowe różnice w eksploatacji prądnic synchronicznych w lądowych i morskich systemach elektroenergetycznych. Podano podstawowe informacje wyznaczanie reaktancji generatorów synchronicznych oraz dodatkowo porównania wartości reaktancji podłużnych wybranych prądnic w wykonaniu lądowym i morskim. Sformułowane wnioski końcowe odniesiono do aktualnych danych literaturowych w rozważanej kwestii.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 185-190
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A survey of the synchronization process of synchronous generators and power electronic converters
Autorzy:
Jarzyna, W.
Powiązania:
https://bibliotekanauki.pl/articles/200510.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
synchronization
micro-generators
SRF PLL
synchronous micro-generator
PV micro-generator
Opis:
The process of synchronization of synchronous generators and power electronic converters with the power grid may take on quite different forms. This is due to their specific principles of operation and essential differences in energy conversion process. However, since synchronous generators and power converter often operate in the same utility network, coherent rules should be defined for them. There-fore, this paper aims at a formulation of the uniform and consistent interpretation of synchronization with the power grid for both types of aforementioned units. The author starts from the classic interpretation of synchronization for synchronous generators and power electronic converters, considered as micro-generators, specifies their mathematical and numerical models and then performs simulation tests. Selected synchronization algorithms are described in detail. Simulation tests are used for analysis of the elaboration of outcomes. The results of simulation tests are handled to formulate a uniform interpretation of synchronization for the micro-generation systems considered. Based on the results obtained, appropriate parallels are built between the two systems being compared. It is shown that the synchronization processes are identical regardless of the micro-generation unit considered. Nonetheless, they differ significantly due to their properties in transient states. Inverter systems have higher dynamics but their disadvantage lies in the relatively high sensitivity to disturbances and the complex selection process of the synchronization algorithm.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 6; 1069-1083
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies