Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "synchronous generator" wg kryterium: Temat


Tytuł:
Wyznaczanie parametrów modelu generatora synchronicznego zmodyfikowaną metodą SSFR w oparciu o symulacje MES z uwzględnieniem nasycenia
Synchronous Generator Model Parameters Estimation Using SSFR Tests Combined With FEM Simulations Taking Into Account Saturation
Autorzy:
Kutt, F.
Michna, M.
Kostro, G.
Racewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/1367525.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
SSFR
MES
generator synchroniczny
model obwodowy
nasycenie
SSFT
FEM
synchronous generator
circuit model
saturation
Opis:
In this paper the StandStill Frequency Response characteristics (SSFR) of saturated synchronous generator (SG) have been calculated using Finite Element Method (FEM) analysis. It was assumed that the saturation level of the generator core can be taken into account by changing the value of the relative magnetic permeability &mur. In the first step, the simulation is performed in the Magneto Static 2D module and the values of &mur &enspwas determined. In the second step the proper value of the &mur&enspis set in the Steady State AC Magnetic module and the frequency characteristics were determine. In order to validate proposed approach FEM simulation from Flux2D software has been compared with the measurements performed on the 10 kVA, 4-poles synchronous machine ELMOR GCe64a of salient rotor construction, equipped with a damper winding.
W artykule przedstawiono zmodyfikowaną metodę SSFR wyznaczania parametrów modelu generatora synchronicznego z uwzględnieniem nasycenia obwodu magnetycznego. Charakterystyki częstotliwościowe uzyskano na drodze symulacji z wykorzystaniem metody elementów skończonych. Założono, że stan nasycenia rdzenia generatora może zostać uwzględniony poprzez zmianę wartości względnej przenikalności magnetycznej. W pierwszym etapie symulację wykonano w module magneto statycznym, wyznaczono wartość przenikalności względnej. W drugim etapie do obliczeń wykorzystano moduł AC zadając odpowiednią wartość przenikalności magnetycznej rdzenia. W celu weryfikacji zaproponowanej metody wykonano pomiary SSFR i symulacje MES dla generatora synchronicznego o wydatnych biegunach.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 4, 108; 101-106
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane, innowacyjne projekty maszyn elektrycznych z magnesami trwałymi i ich praktyczne zastosowania
Selected innovative designs of electrical machines with permanent magnets and their practical applications
Autorzy:
Gawron, S.
Powiązania:
https://bibliotekanauki.pl/articles/1200827.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
napęd elektryczny
silnik z magnesami trwałymi
prądnica z magnesami trwałymi
electric drive
permanent magnet synchronous motor
permanent magnet synchronous generator
Opis:
Electrical machines with permanent magnets are characterized by simple design, highest power efficiency and highest power density among all known and used types of electrical machines. PM machines are perfectly suited to drives requiring wide range of rotational speed control and drives with high starting torque. They are also used in drives, where weight of the machine is the decisive factor. In the current paper the most interesting designs of electrical machines and their applications have been discussed. All of the described machines have been designed and built in the Institute of Electrical Drives and Machines Komel.
Maszyny elektryczne z magnesami trwałymi są prostej budowy, mają najwyższą sprawność energetyczną oraz dysponują największą gęstością mocy ze wszystkich znanych i stosowanych rodzajów maszyn elektrycznych. Maszyny tego typu doskonale nadają się do układów napędowych, w których wymagana jest szeroka regulacja prędkości obrotowych oraz w napędach o dużym momencie rozruchowym. Maszyny tego typu stosowane są również w napędach, w których determinującym parametrem jest ich masa. W niniejszym artykule przedstawiono i omówiono najciekawsze projekty maszyn z magnesami trwałymi i ich praktyczne zastosowania, które w kilku ostatnich latach zrealizowano w Instytucie Napędów i Maszyn Elektrycznych KOMEL.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 1, 109; 1-10
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wymagań określonych w kodeksie sieci dla przyłączania jednostek wytwórczych, a w szczególności wymagania pozostania w pracy podczas zwarcia, na przepięcia generowane w obwodzie wirnika generatora synchronicznego
The impact of the “ENTSO-E NETWORK CODE” requirements, especially fault-ride-through capability, for the overvoltages in the excitation circuit of synchronous generator
Autorzy:
Mazur, M.
Powiązania:
https://bibliotekanauki.pl/articles/268464.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
Network Code RfG
układ wzbudzenia
przepięcia w wirniku generatora synchronicznego
Excitation system
overvoltage in the synchronous generator rotor
Opis:
W referacie przedstawiono wymagania dla bloków wytwórczych wynikające z kodeku sieci, dotyczącego wymogów w zakresie przyłączenia jednostek wytwórczych, uchwalonego rozporządzeniem Komisji Europejskiej w kwietniu b.r.. Omówiono zawartość tego kodeksu, klasyfikacje jednostek wytwórczych z niego wynikających oraz wymogi stawiane poszczególnym ich typom, a także wynikające z niego implikację dla systemów wzbudzenia generatorów synchronicznych dużych mocy. Szczegółowej analizie poddano, wymaganie pozostania w pracy podczas zwarcie konwencjonalnego bloku wytwórczego dużej mocy. Wymaganie to jest najtrudniejszym wymaganiem, a analiza dotyczyła wpływu tego wymagania na rozwiązania techniczne systemów wzbudzenia. Przedstawiono także propozycję rozwiązań technicznych tychże systemów, umożliwiające spełnienie wymagań kodeksu.
This article presents issues related with the European Commission Regulation establishing a Network Code for Requirements for Grid Connection Applicable to all Generators. Paper presents the content of this Network Code, especially classifications of Power Generation Modules and the requirements for their individual types. Especially analyzed the impact of this requirements for the excitation systems of high power synchronous generators. Simulation analysis concerned on the impact of fault-ride-through capability requirement, on rotor crowbar circuit of the excitation systems of synchronous generators. This kind of fault could cause overvoltage in the rotor and excitation system crowbar operation. Most of existing excitation systems, immediately trip the unit in this case. The article presents suggestions for technical solutions, enabling the fulfillment of this requirement. Fault-ride-through capability requirement is the most difficult requirement to fulfill by Power Generation Modules, and will require modification on design rules for Power Generators, their auxiliary systems, including the hardware and software scope of the excitation systems.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 50; 63-66
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wieloobszarowa regulacja systemu turbogeneratora elektrowni jądrowej
Multiregional control of nuclear power plant turbogenerator system
Autorzy:
Sokólski, P.
Kulkowski, K.
Kobylarz, A.
Duzinkiewicz, K.
Rutkowski, T. A.
Grochowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/952780.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
turbogenerator
turbina parowa
generator synchroniczny
regulacja rozmyta
steam turbine
synchronous generator
nuclear power plant
fuzzy control
Opis:
W artykule przedstawiono propozycję zaawansowanej struktury sterowania układem turbogeneratora w szerokim zakresie zmian zapotrzebowania na moc czynną. Dla potrzeb syntezy tej struktury wykorzystano nieliniowe, dynamiczne modele turbiny parowej i generatora synchronicznego współpracującego z systemem elektroenergetycznym. Zaproponowane algorytmy sterowania oparte są odpowiednio o wieloobszarowe regulatory rozmyte, z lokalnymi regulatorami PI. Miękkie przełączanie pomiędzy nimi jest realizowane za pomocą rozmytego wnioskowania Takagi-Sugeno-Kanga. Zaprezentowane wyniki badań symulacyjnych pokazują poprawę jakości realizacji zadania nadążania za zmienną trajektorią zadanej mocy czynnej, przy wykorzystaniu zaproponowanych rozwiązań, w porównaniu do klasycznych, pojedynczych regulatorów PI w pętlach sterowania turbiny i generatora synchronicznego.
In the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multiregional fuzzy control systems with local linear controllers, including PID controllers, in particular control loops of turbine and generator. Soft switching between the local controllers is performed by Takagi-Sugeno-Kang fuzzy logic mechanism. Parameters of the local controllers were optimally tuned for a priori chosen operating points within the range 50-100% of nominal active power generated by the synchronous generator. Simulation results show that proposed advanced control structure is superior to widely used classic control structure (local controllers tuned for nominal operating points). During simulations the data of the real devices were used, respectively for the 4 CK 465 steam turbine and synchronous generator GTHW-600, which were planned to be used in the first Polish nuclear power plant in Żarnowiec.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 129-132
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielobiegunowa prądnica synchroniczna ze wzbudzeniem hybrydowym
A multipolar synchronous generator with hybrid excitation
Autorzy:
Gawron, Stanisław
Glinka, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/1857446.pdf
Data publikacji:
2021
Wydawca:
Wydawnictwo Druk-Art
Tematy:
prądnica synchroniczna
magnesy trwałe
wzbudzenie elektromagnetyczne
synchronous generator
permanent magnets
electromagnetic excitation
Opis:
Wielobiegunowa prądnica synchroniczna ma liczbę par biegunów p = pPM + pEM. Bieguny (2pPM) są wzbudzane magnesami trwałymi, a na biegunach (2pEl) jest umieszczone uzwojenie wzbudzenia. W artykule przedstawiono prądnicę synchroniczną o liczbie par biegunów p = 6, przy czym cztery pary biegunów są wzbudzane magnesami trwałymi przyklejonymi na powierzchni nabiegunników, a dwie pary biegunów są wzbudzane elektromagnetycznie. W ten sposób straty mocy wzbudzenia zmniejszają się o 66%. Sześciofazowe uzwojenie twornika (2 x 3 fazy) umożliwia zwiększenie mocy znamionowej prądnicy o 3,4% i o taką samą wartość zmniejszają się straty mocy w uzwojeniu twornika. Prądnica przy pracy samotnej i zmianach mocy obciążenia ma możliwość stabilizacji napięcia, a przy pracy na sieć elektroenergetyczną umożliwia regulację, w sposób ciągły, mocy biernej. Uzwojenie wzbudzenia ma małą masę miedzi, tym samym straty mocy w uzwojeniu wzbudzenia są małe.
A multi-pole synchronous generator has a number of pole pairs p = pPM + pEM. The poles (2pPM) are excited with permanent magnets, and the field winding is located at the poles (2pEl). The article presents a synchronous generator with the number of pole pairs p = 6, where four pole pairs are excited with permanent magnets glued on the surface of the pole pieces, and two pole pairs are electromagnetically excited. In this way, the excitation power loss is reduced by 66%. The six-phase armature winding (2 x 3 phase) allows the generator’s rated power to increase by 3,4% and the power loss in the armature winding is reduced by the same amount. The generator in the case of off-gird work and changes of load power has the ability to stabilize the voltage, and when working on-grid it allows continuous regulation of reactive power. The excitation winding has a small copper mass, thus the power losses in the field winding are low.
Źródło:
Napędy i Sterowanie; 2021, 23, 4; 28-31
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielobiegunowa prądnica synchroniczna ze wzbudzeniem hybrydowym
A multipolar synchronous generator with hybrid excitation
Autorzy:
Gawron, Stanisław
Glinka, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/2056363.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
prądnica synchroniczna
magnesy trwałe
wzbudzenie elektromagnetyczne
synchronous generator
permanent magnets
electromagnetic excitation
Opis:
Wielobiegunowa prądnica synchroniczna ma liczbę par biegunów [wzór] . Bieguny [wzór] są wzbudzane magnesami trwałymi, a na biegunach [wzór] jest umieszczone uzwojenie wzbudzenia. W artykule przedstawiono prądnicę synchroniczną o liczbie par biegunów p=6, przy czym cztery pary biegunów są wzbudzane magnesami trwałymi przyklejonymi na powierzchni nabiegunników, a dwie pary biegunów są wzbudzane elektromagnetycznie. W ten sposób straty mocy wzbudzenia zmniejszają się o 66%. Sześciofazowe uzwojenie twornika (2x3 fazy) umożliwia zwiększenie mocy znamionowej prądnicy o 3,4% i o taką samą wartość zmniejszają się straty mocy w uzwojeniu twornika. Prądnica przy pracy samotnej i zmianach mocy obciążenia ma możliwość stabilizacji napięcia, a przy pracy na sieć elektroenergetyczną umożliwia regulację, w sposób ciągły, mocy biernej. Uzwojenie wzbudzenia ma małą masę miedzi, tym samym straty mocy w uzwojeniu wzbudzenia są małe.
A multi-pole synchronous generator has a number of pole pairs [wzór] . The poles [wzór] are excited with permanent magnets, and the field winding is located at the poles [wzór] . The article presents a synchronous generator with the number of pole pairs p = 6, where four pole pairs are excited with permanent magnets glued on the surface of the pole pieces, and two pole pairs are electromagnetically excited. In this way, the excitation power loss is reduced by 66%. The six-phase armature winding (2x3 phase) allows the generator's rated power to increase by 3.4% and the power loss in the armature winding is reduced by the same amount. The generator in the case of off-gird work and changes of load power has the ability to stabilize the voltage, and when working on-grid it allows continuous regulation of reactive power. The excitation winding has a small copper mass, thus the power losses in the field winding are low.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2019, 3-4, 123-124; 61--65
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of the finite element method for parameter estimation of the circuit model of a high power synchronous generator
Autorzy:
Berhausen, S.
Paszek, S.
Powiązania:
https://bibliotekanauki.pl/articles/200790.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
synchronous generator model
finite element method
field-circuit model measurement verification
circuit model parameter estimation
model synchronicznego generatora
metoda elementów skończonych
weryfikacja modelu pomiaru pola obwodu
estymacja parametrów modelu obwodu
Opis:
The paper presents the two-dimensional, field-circuit model of a high power synchronous generator verified by measurements. The model enables determining the waveforms of electromagnetic quantities in steady and transient states. Verification of the model was based on comparison of the measured and calculated waveforms after a disturbance in the voltage regulation system of a TWW-200-2 generator operating in Połaniec Power Plant. There are also presented the field methods for determining electromagnetic parameters (synchronous reactances and time constants) when using the distributions of static and quasi-static, magnetic and electromagnetic fields calculated by the finite element method (FEM). The set of these parameters was used as the starting parameters of the optimization algorithm for estimation of electromagnetic parameters of the synchronous generator circuit model. The dynamic waveforms under the generator load conditions calculated by the finite element method are the basis of parameter estimation. The parameter estimation of the generator model was performed with the use of the least squares method.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 3; 575-582
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Train based on virtual synchronous generator technology uninterrupted phase-separation passing study
Autorzy:
Wang, Ying
Yang, Huan
Chen, Xiaoqiang
Guo, Ya
Powiązania:
https://bibliotekanauki.pl/articles/27309940.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
energy storage railway power conditioner
single-phase inverter
uninterrupted
phase-separation passing
virtual synchronous generator
Opis:
The problem of large speed loss exists in the traditional passing through the electric phase-separation method of trains, which is more prominent when trains pass through an electric phase-separation zone in the uphill section of long ramps and may lead to the trains not passing through the phase-separation zone safely. In order to solve this problem, based on the energy storage type railroad power conditioner, a train uninterrupted phase-separation passing system based on the energy storage type railroad power conditioner is proposed. The energy storage railroad power conditioner can realize the recovery and utilization of regenerative braking energy of the electrified railroad. In the structure of the energy storage railroad power conditioner, the single-phase inverter is led from the middle DC side of the energy storage railroad power conditioner and connected to the neutral line through the LCL filter and the step-up transformer, which constitutes an uninterrupted phase separation passing system. The single-phase inverter is controlled using virtual synchronous generator technology, which allows the single-phase inverter to have external characteristics similar to those of a synchronous generator, providing support for the voltage and frequency in the neutral zone. The power required by the train to pass the electric phase-separation is provided by the power supply arm or the energy storage system, which not only improves the utilization rate of regenerative braking energy but also realizes the uninterrupted phase separation passing of the train through the control of the voltage in the neutral region.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 755--768
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-level Vienna Rectifier with a Brushless and Permanent Magnetless Generator for Wind Energy Conversion Systems
Autorzy:
Bhattacherjee, Haimanti
Mukherjee, Debranjan
Chakraborty, Chandan
Powiązania:
https://bibliotekanauki.pl/articles/2175926.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
brushless synchronous generator
magnetless synchronous generator
maximum power point
unity power factor
Vienna rectifier
wind energy conversion system
Opis:
This paper proposes a system design and control technique for a newly developed brushless and permanent magnetless synchronous generator-based variable-speed wind energy generation system, transferring power to a constant voltage dc grid via a three-level Vienna rectifier (VR). The recently established generator named Brushless Induction excited Synchronous Generator (BINSYG) is a wound field synchronous generator (WFSG), whose excitation is developed by controlling an Induction Machine fitted to the same machine structure and sharing the same magnetic core. A new controller is proposed that ensures the stable operation of BINSYG for a wide variation of shaft speeds. VR achieves sinusoidal input current and can control the power factor at its input, which is particularly suitable for wind energy applications. The top and bottom capacitor voltages of the VR are balanced using redundant switching combinations. The system with its proposed control algorithm is modelled in MATLAB/Simulink for a 5 kW rated BINSYG feeding power to a 750 V dc grid. The steady-state and dynamic state simulation results are presented and the controller performance is verified for a wide range of wind speeds. Further, real-time results using the OPAL-RT testbed are presented for the same system to verify the effectiveness of the overall control strategy.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 84--102
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System zdalnego monitoringu parametrów pracy siłowni wiatrowej o pionowej osi obrotu
Remote monitoring system for the working parameters of a wind turbine with vertical axis
Autorzy:
Kostro, Grzegorz
Kutt, Filip
Michna, Michał
Ryndzionek, Roland
Sienkiewicz, Łukasz
Ronkowski, Mieczysław
Powiązania:
https://bibliotekanauki.pl/articles/267329.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
elektrownie wiatrowe o pionowej osi obrotu
generator synchroniczny z magnesami trwałymi
pomiary parametrów pracy
zdalny monitoring
vertical axis wind turbine
permanent magnet synchronous generator
measurement working parameters
remote monitoring
Opis:
W artykule przedstawiono układ do zdalnego monitorowania parametrów pracy elektrowni wiatrowej o pionowej osi obrotu. Do budowy systemu wykorzystano mikrokomputer klasy Raspberry PI 3 z zainstalowanym systemem operacyjnym Raspbian oraz kartę pomiarową MicroDAQ E2000. Opracowany system umożliwia monitorowanie mocy na wyjściu generatora, momentu na wale turbiny, prędkości obrotowej turbiny oraz prędkości wiatru. Wartości monitorowanych parametrów zapisywane są w pamięci karty pomiarowej. Dzięki zastosowaniu mikrokomputera możliwe było podłączenie komputera zewnętrznego do systemu i przesyłanie zapisanych danych oraz monitorowanie ich wartości online.
The article presents a system for remote monitoring of working parameters of a wind turbine with vertical axis. The system was built using a Raspberry PI 3 microcomputer with the Raspbian operating system and a MicroDAQ E2000 measuring card. The developed system enables monitoring the power output of the generator, torque on the turbine shaft, turbine speed and wind speed. The values of the monitored parameters are saved in the memory of the measuring card. Due to the use of a microcomputer, it is possible to connect an external computer to the system and send saved data and monitor their value online.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 64; 25-28
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis of the adaptive excitation control system of high power synchronous generators
Synteza adaptacyjnych systemów sterowania wzbudzenia do generatorów synchronicznych dużej mocy
Autorzy:
Dambrauskas, A.
Karaliunas, B.
Shulskis, D.
Powiązania:
https://bibliotekanauki.pl/articles/159112.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
generator synchroniczny
generator dużej mocy
sterowanie adaptacyjne
optymalizacja
powerful synchronous generator
excitation system
adaptive control
optimisation
variable structure
simplex search
software package
Opis:
New promising excitation systems of high power synchronous generators, which are operating in the interconnected power system, are considered. Based on general assumptions, a system of differential equations, transfer functions and a block diagram of the excitation system, as the automatic control object, were obtained. Mathematical description of electromechanical transient processes for emergency situations in the power system is very complicated and limited. In these cases, the efficiency of the excitation current regulator can be increased by using combined algorithms of the simplex search, when, in the optimization process, the local efficiency function is approximated by a separable equation. Based on the expressions obtained, the synthesis of generator adaptive excitation control system and optimization blocks has been developed. The proposed scheme of adaptive system synthesis allows us to eliminate search errors. The results of synthesis show that the transitional process of generator voltage is similar to the optimal.
W artykule omówiono nowe obiecujące systemy wzbudzenia generatorów synchronicznych dużej mocy, pracujących we wspólnym systemie mocy. W oparciu o ogólne założenia otrzymano układ równań różniczkowych, funkcji przejścia oraz wykres blokowy układu wzbudzenia jako obiektu sterowania automatycznego. Matematyczne opisy elektromechanicznych procesów przejściowych są bardzo złożone i ograniczone. W takich przypadkach sprawność działania regulatora prądu wzbudzenia można zwiększyć stosując złożone algorytmy poszukiwań simpleksowych, gdy w procesie optymalizacji, lokalna funkcja sprawności jest aproksymowana równaniem separowalnym. W oparciu o uzyskane wyrażenia opracowano syntezę, adaptacyjny układ sterowania wzbudzenia generatora oraz bloki optymalizacji. Proponowany schemat syntezy układu adaptacyjnego pozwala eliminować błędy poszukiwania. Wyniki syntezy wskazują na to, że proces przejściowy napięcia generatora jest zbliżony do optymalnego.
Źródło:
Prace Instytutu Elektrotechniki; 2006, 226; 5-18
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchronous Generator Model with Nonlinear Magnetic Circuit
Model generatora synchronicznego uwzględniający nieliniowość obwodu magnetycznego
Autorzy:
Spałek, D.
Powiązania:
https://bibliotekanauki.pl/articles/396954.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
synchronous generator
nonlinear magnetic circuit
numerical model
generator synchroniczny
nieliniowy obwód magnetyczny
model symulacyjny
Opis:
A synchronous generator with voltage controller is a system whose work describes the ordinary differential equation set for the equivalent circuits. For the nonlinear magnetic circuit of a synchronous generator (stator and rotor saturation) the differential set is nonlinear. The solution of such a problem needs to develop the appropriate model for numerical simulations of the generator. First of all, the generator model type e.g. (1,1), (2,2), (3,3) or other should be chosen. Furthermore, the equivalent parameters for the model of synchronous generator should be chosen. The nonlinearity of magnetic circuit leads to changes of some equivalent parameters and additional numerical computations. There is a numerical program developed in C++ for simulations of transients in order to investigate their sensitivity to generator nonlinearity (saturation effect) and equivalent parameters values. The described program (available at www.elektr.polsl.pl/dspalek/) enables to decide whether the nonlinearity for d/q axis should be taken into account and which equivalent parameter are of high importance. Subsequently, the presented model leads to conclusions on which parameters should influence significantly synchronous generator work in a power system.
Generator synchroniczny wraz z układem wzbudzenia jest obiektem, którego pracę opisuje układ równań różniczkowych zwyczajnych. Przy uwzględnieniu nasycania się obwodu magnetycznego maszyny synchronicznej układ równań różniczkowych jest nieliniowy. Rozwiązanie takiego układu równań różniczkowych wymaga zaproponowania schematu zastępczego dla potrzeb symulacji pracy generatora. Po pierwsze powinien zostać wybrany model generatora synchronicznego np. (1, 1), (2, 2), (3,3) lub inny. Następnie należy dobrać parametry dla obwodów zastępczych generatora. Uwzględnienie nieliniowości obwodu magnetycznego prowadzi do zmian parametrów zastępczych w funkcji prądów i prowadzi do dodatkowych obliczeń przy rozwiązywaniu układu równań różniczkowych. Opracowany został autorski program napisany w języku C++, który pozwala na symulację pracy stanów nieustalonych oraz ocenę wrażliwości otrzymywanych przebiegów na: nieliniowość obwodu i parametry schematu zastępczego. Omawiany symulator numeryczny (dostępny na stronie: www.elektr.polsl.pl/dspalek/) pozwala na szybką ocenę wrażliwości na dany parametr obwodu i nieliniowości w osi d/q, a w konsekwencji pozwala podejmować decyzje, czy należy dokonywać dokładniejszej identyfikacji parametrów modelu dla opisu pracy generatora w systemie energetycznym.
Źródło:
Acta Energetica; 2013, 4; 144-157
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchronous Generator Model with Fractional Order Voltage Regulator PIbDa
Model generatora synchronicznego z ułamkowym regulatorem napięcia PIbDa
Autorzy:
Spałek, D.
Powiązania:
https://bibliotekanauki.pl/articles/397275.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
synchronous generator
voltage regulator PIbDa
fractional derivative
generator synchroniczny
regulator napięcia PIbDa
pochodna ułamkowa
Opis:
Synchronous generator together with excitation circuit, voltage controller and system stabilizer constitute nonlinear ordinary differential equations set. The nonlinearity of differential equations set results from magnetic circuits saturation. One of the most important, from the electric energy distribution point of view, is the influence of voltage control applied on the generator voltage. There could be applied regulator either classical PID or fractional of type PIbDa which bases on the so-called fractional derivative idea. Numerical solutions of nonlinear differential equations set, that takes into account both magnetic circuits saturation and fractional regulator PIbDa, lead to decisions either to accept or to reject the chosen parameters. The sensibility of generator work on chosen fractional regulator parameters is the main aim of this paper. With the help of C++ program provided the most important states of work (short–circuit, setting voltage change, reactive power rejection) can be analyzed basing on the accepted model of synchronous generator such as (1,1), (2,2) or (3,3).
Generator synchroniczny wraz z układem wzbudzenia, regulatorem napięcia i stabilizatorem jest obiektem, którego zachowanie można opisać układem równań różniczkowych zwyczajnych nieliniowych. Nieliniowość równań różniczkowych jest wynikiem nasycania się obwodu magnetycznego generatora synchronicznego. Na pracę generatora z punktu widzenia energetyki ma istotny wpływ zastosowany regulator napięcia, czy to klasyczny PID, czy też ułamkowy typu PIbDa wykorzystujący pochodne rzędu niecałkowitego. Rozwiązanie numeryczne układu równań różniczkowych nieliniowych, uwzględniających nasycenie obwodu magnetycznego oraz zastosowanie regulatora ułamkowego PIbDa, pozwala na ocenę i dobór parametrów regulatora. Wrażliwość na wybrane parametry regulatora jest przedmiotem analiz numerycznych. Program autorski C++ pozwala na ocenę pracy generatora w wybranych stanach nieustalonych (zwarcie, zaburzenie napięcia zadanego, zrzut mocy czynnej), z wykorzystaniem wybranego modelu generatora synchronicznego (1,1), (2,2) lub (3,3).
Źródło:
Acta Energetica; 2015, 2; 78-90
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchrogenverter - parallel connection of synchronous generator and power converter with energy storage
Autorzy:
Szulawski, P.
Koczara, W.
Powiązania:
https://bibliotekanauki.pl/articles/1193215.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
synchronous generator
power electronic converter
synchrogenverter
energy storage current control
Opis:
The paper describes novel power generation topology wherein synchronous generator have a parallel connected power electronic converter. In this arrangement synchronous generator is only source of active power and power electronic converter is source of reactive power. Such power distribution allows to increase the synchronous generator generated active power by 25%, and operate with unity power factor. The power converter with energy storage system embedded can deliver additional active power in transient state to improve generator stability.
Źródło:
Power Electronics and Drives; 2016, 1, 36/1; 69-78
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of prototype multi-pole non-salient field winding for high speed brushless synchronous generator
Autorzy:
Kutt, F.
Kostro, G.
Michna, M.
Ronkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1813550.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
synchronous generator
non-salient field winding
high speed
brushless excitation
autonomous electrical power system
Opis:
In this paper a non-salient field winding for a brushless synchronous generator working with high speed in an autonomous energy generation system (e.g. airplane power grid) has been presented. A conception of a six-pole cylindrical-rotor with distributed field winding has been proposed. Comparison study of salient and prototype non-salient field winding has been carried out. Chosen simulation and measurement results of the generator stator voltage and current waves have been presented.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 273-278
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies