Statistical analysis of supply voltage levels for rural customers
Autorzy:
Nęcka, K.
Trojanowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/410783.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
low voltage networks
supply voltage quality
Opis:
In the elaboration, levels of supply voltage at the ends of loaded low-voltage lines were statistically evaluated, describing them using basic statistical measures and examining the frequency distributions. Levels of voltages and time of their occurrence on the background of current regulations were also assessed. It was found out that in spite of the fulfilment of statutory requirements electricity consumers complained about the poor, in their opinion, quality of the voltage.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2016, 5, 3; 77-82
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Support Insulator with Voltage Measurement Function to MV Switches
Izolator wsporczy z funkcją pomiaru napięcia do rozdzielnic SN
Autorzy:
Bandel, Janusz
Krasuski, Krzysztof
Błażejczyk, Tomasz
Hejduk, Artur
Mykowiecki, Mariusz
Krogulec, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/159353.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
izolator wsporczy
sensor supply voltage
dzielnik rezystancyjny
support insulator
Opis:
W artykule przedstawiono konstrukcję izolatora wsporczego z funkcją pomiaru napięcia do zastosowania w rozdzielnicach wnętrzowych z izolacją powietrzną, o napięciu znamionowym do 24 kV. Podano wymagania norm stawiane izolatorom wsporczym, jak i sensorom pomiarowym. Przeanalizowano wpływ materiału izolacyjnego (żywicy epoksydowej) na przekładnię sensora pomiarowego dla różnych częstotliwości napięcia (wyższe harmoniczne sieciowe). Wykonano analizę pola elektrycznego wzdłuż członu niskonapięciowego sensora w celu zapewnienia równomiernego jego rozkładu. Porównano nowo opracowany sensor z obecnym już na rynku sensorem pomiarowym bez funkcji wsporczej.
The article presents construction of a new support insulator with a voltage measurement function for use in indoor switchgears with air insulation, for rated voltage up to 24 kV. Standard requirements for support insulators as well as measuring sensors have been given. The influence of insulating material (epoxy resin) on the measuring sensor accuracy for different voltage frequencies (higher network harmonics) was analyzed. The electric field was analyzed in order to ensure uniform distribution along the low voltage sensor. The newly developed sensor was compared to the sensor but without function of a support insulator.
Źródło:
Prace Instytutu Elektrotechniki; 2020, 281; 17-24
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zaburzenia napięcia w górniczych systemach zasilania powodowane prądami doziemnymi dużych częstotliwości
Voltage disturbances in mining power supply systems caused by high-frequency earth currents
Autorzy:
Szymański, J.
Powiązania:
https://bibliotekanauki.pl/articles/187521.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
filtr pojemnościowy EMC
napięcie zasilania
EMC capacity filter
supply voltage
Opis:
W artykule przeanalizowano wpływ napędów z niskonapięciowymi przemiennikami częstotliwości dużych mocy, zasilanymi sieciami nieuziemionymi, na napięcie zasilania. Prądy bowiem upływu, które płyną poprzez doziemne pojemności pasożytnicze powodują zaburzenia fazowych napięć zasilania. Negatywne skutki prądów upływu wzrastają w przemiennikach dużych mocy z długimi kablami silnikowymi. Wykazano, że stosując pojemnościowy filtr EMC (ang. ElectroMagnetic Capability) na zasilaniu przemiennika częstotliwości można radykalnie zmniejszyć zaburzenia napięć w sieci zasilania.
The article features an analysis of the impact of drives with low-voltage high-power frequency converters, powered by non-grounded networks, on voltage supply. The leakage currents which flow through earth parasitic capacities cause disturbances of phase voltage supply. Negative impact of leakage currents increases in high-power converters with long engine cables. It was demonstrated that using an EMC capacity filter on the frequency converter supply it is possible to significantly diminish voltage disturbances in a power supply network.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2010, R. 48, nr 7, 7; 11-16
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wskaźników charakteryzujących jakość napięcia w wiejskich sieciach elektroenergetycznych
Analysis of indicators characterising the quality of voltage in rural power networks
Autorzy:
Trojanowska, M.
Nęcka, K.
Powiązania:
https://bibliotekanauki.pl/articles/287000.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
energia elektryczna
jakość
napięcie zasilające
electric power
quality
supply voltage
Opis:
Na podstawie kryterium uniwersalności, zmienności oraz ważności zidentyfikowano wskaźniki, które dobrze charakteryzują jakość napięcia w wiejskich elektroenergetycznych sieciach rozdzielczych i są możliwe do wyznaczenia na podstawie danych aktualnie zbieranych w spółkach dystrybucyjnych. W oparciu o wybrane wskaźniki przeanalizowano, metodą porządkowania liniowego, zróżnicowanie jakości energii elektrycznej na obszarach wiejskich Polski południowej.
The criterion of universality, variability and importance became a basis for the identification of indicators that characterise well the quality of voltage in rural power distribution networks and can be determined on the basis of data being collected in distribution companies. On the basis of selected indicators, the differentiation of the quality of electric power in rural areas of southern Poland was analysed using the linear ordering method.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 4, 4; 269-274
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of higher harmonics generation by non-linear loads
Analiza wytwarzania wyzszych harmonicznych przez odbiorniki nieliniowe
Autorzy:
Necka, K.
Powiązania:
https://bibliotekanauki.pl/articles/793595.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
nonlinear load
distortion factor
higher harmonics
oscillogram
low-voltage grid
transformer station
supply voltage
supply current
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza jakości napięcia zasilającego gospodarstwa wiejskie
Analysis of power supply voltage quality in rural farms
Autorzy:
Trojanowska, M.
Nęcka, K.
Powiązania:
https://bibliotekanauki.pl/articles/291844.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
gospodarstwo wiejskie
energia elektryczna
napięcie zasilające
jakość
rural farm
electric power
supply voltage
quality
Opis:
W pracy przedstawiono wyniki badań jakości napięcia zasilającego odbiorców wiejskich na terenach Polski południowej, a w szczególności wyniki pomiarów wartości napięcia, niesymetrii napięć oraz odkształceń napięcia. Na badanych terenach wartości parametrów opisujących jakość napięcia przeważnie mieszczą się w granicach tolerancji przewidzianych w normie i przepisach. Jedynie w 2 procentach obwodów wartości napięcia zasilającego przekraczały wartości dopuszczalne. W najbliższej przyszłości może jednak nastąpić pogorszenie jakości dostarczanej energii, zwłaszcza w zakresie odkształcenia krzywej napięcia zasilającego, wskutek zmian w strukturze użytkowanych odbiorników elektrycznych.
Results of line supply voltage quality measurements in rural farms located in the southern Poland were presented. They included in particular voltage levels, unsymmetrical voltages and voltage deformation measurements. Values of those parameters that describe line supply quality were found within the range of tolerance determined in both standards and regulations. The line supply voltage values exceeded permissible levels only in 2% of cases. It is however expected that the line supply may deteriorate in the near future, in particular due to deformation of the voltage characteristic curve caused by changes in structure of the utilized electric receivers.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 7 (95), 7 (95); 221-227
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy zmiana napięcia trakcyjnego w Polsce ma uzasadnienie?
Is the change in traction power supply voltage in Poland justified?
Autorzy:
Szafrański, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/252763.pdf
Data publikacji:
2019
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
napięcie zasilające
kolejowa trakcja elektryczna
zmiana napięcia
sieć kolejowa
supply voltage
railway electric traction
voltage change
railway network
Opis:
W Polsce po raz kolejny odżyła dyskusja o ewentualnej zmianie napięcia zasilającego w kolejowej trakcji elektrycznej. System 3 kV prądu stałego (DC) przestawia się jako przestarzały i nieodpowiedni do występujących obecnie potrzeb przewozowych. Przesłanką wyzwalającą dyskusję były zapewne decyzje podjęte przez naszych południowych sąsiadów Czechów o sukcesywnym przechodzeniu za zasilanie prądem przemiennym 25 kV 50 Hz. Czy w warunkach funkcjonowania polskiej sieci kolejowej taka zmiana ma sens?
Źródło:
TTS Technika Transportu Szynowego; 2019, 10; 37-41
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Supply railway traffic control devices in case of failure of the power system
Autorzy:
Nowakowski, W.
Olczykowski, Z.
Wojciechowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/393677.pdf
Data publikacji:
2017
Wydawca:
Polskie Stowarzyszenie Telematyki Transportu
Tematy:
blackout
railway traffic control devices
power quality
disorders of the supply voltage
urządzenia sterowania ruchem kolejowym
jakość zasilania
zaburzenia napięcia zasilania
Opis:
The development of technology led to a situation where the developed economies are completely dependent on electricity. Access to energy sources modern power stations, the right structure and condition of the transmission lines as well as providing continuity of supply are the basis for national energy security. Failures in the energy system always result in financial losses incurred by both suppliers and consumers of electricity. The costs depend mainly on the scope of the accident, the degree of damage to the power system, the duration and the number of customers without power. The modern energy is facing a very long list of problems. Overcoming these problems is the basis of energy security of the country. The globalization of the world economy, next to its threats is also a cornerstone of the joint actions to ensure the continuity of supply of energy to customers. A very of importance then becomes ensure the functioning of transportation during system failures.
Źródło:
Archives of Transport System Telematics; 2017, 10, 4; 16-20
1899-8208
Pojawia się w:
Archives of Transport System Telematics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A 400 fJ per-cycle frequency reference for internet of things
Autorzy:
Coustans, M.
Krummenacher, F.
Terrier, C.
Kayal, M.
Powiązania:
https://bibliotekanauki.pl/articles/397716.pdf
Data publikacji:
2016
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
time reference
supply voltage insensitivity
temperature insensitivity
ultra-low power
always on domain optimization
odniesienie czasowe
napięcie zasilające
ultra low power
Opis:
This work presents an ultra-low power oscillator designed to target different contexts, such as crystal-assisted timekeeping, reference oscillator to optimize the always on domain of a microcontroller or wake-up timer. This oscillator enables ultralow power operation in 0.18 μm CMOS technology; the core oscillator consumes 2.5 nW at room temperature, with a temperature stability of 14 ppm/°C [-40°C - 60°C] and 0.07 %/V supply sensitivity.
Źródło:
International Journal of Microelectronics and Computer Science; 2016, 7, 2; 41-46
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Balancing reactive compensation at three-phase four-wire systems with a sinusoidal and asymmetrical voltage source
Autorzy:
Sołjan, Z.
Hołdyński, G.
Zajkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/200474.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
currents' physical components
power theory
asymmetrical voltage supply
balancing reactive compensation
Opis:
The article presents the essentials of reactance compensation of unbalanced loads in three-phase four-wire systems powered by a sinusoidal and asymmetrical voltage source. The whole of compensation and symmetrization is based on the Currents’ Physical Components (CPC) theory. Reactance compensation, i.e. compensation based solely on inductors and capacitors, in four-wire systems requires the device to be included in a star (Y) structure in order to compensate for the reactive current (reactive power) and the current at the neutral conductor caused by zero sequence asymmetry, and for the device in a delta (∆) structure to allow compensation of the reactive current (reactive power) and current, causing asymmetry of the negative sequence.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 1; 71-79
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza efektywności filtrów wygładzających w podstacjach trakcji kolejowej 3 kV dc przy zaburzeniach napięcia zasilającego
Analysis of effectivenesses of filters smoothing in substations of railway 3 with the DC kV at disorders of the powering tension
Autorzy:
Szeląg, A.
Maciołek, T.
Powiązania:
https://bibliotekanauki.pl/articles/253459.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
trakcja kolejowa
zaburzenie napiecia zasilającego
podstacja trakcyjna
Zakład Elektroenergetyki Kolejowej
railway traction
supply voltage disturbance
traction substation
Department of Electrical Power Rail
Opis:
Kryteria jakości energii elektrycznej w odniesieniu do systemu zasilania prądu stałego dotyczą obwodów, od prostowników zainstalowanych w podstacjach trakcyjnych aż do odbieraka prądu pojazdu. Prawo energetyczne i przepisy wykonawcze jednoznacznie stwierdzają, że zelektryfikowany system transportu jako odbiorca energii ma spełniać warunki poboru energii określone w umowie, co narzuca określone wymagania wobec Zakładów Elektroenergetyki Kolejowej.
Źródło:
TTS Technika Transportu Szynowego; 2013, 5; 34-39
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uwarunkowania podwyższenia napięcia znamionowego sieci rozdzielczych i zasilających w zakładach górniczych
Requirements for increase in rated voltage of supply distribution networks in mines
Autorzy:
Gawor, P.
Boron, S.
Cholewa, A.
Powiązania:
https://bibliotekanauki.pl/articles/185975.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
górnictwo
napięcie znamionowe sieci rozdzielczych
napięcie znamionowe sieci zasilających
mining
rated voltage of distribution networks
rated voltage of power supply networks
Opis:
W artykule przedstawiono wyniki analizy zakresu i możliwości wprowadzenia napięć wyższych od 6 kV w sieciach rozdzielczych i zasilających podziemnych zakładów górniczych. W analizie uwzględniono uwarunkowania wynikające z dopuszczalnej obciążalności i wytrzymałości zwarciowej kabli i aparatury, a także bezpieczeństwa eksploatacji urządzeń elektrycznych.
The results of analysis of a range and chances of using the voltages higher than 6 kV in distribution and power supply networks at underground mines have been presented in the paper. In the analysis there have been taken into consideration the requirements resulted from limiting load-carrying capacity and short-circuit strength of cables and apparatus as well as a safety of operation of electric equipment.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2009, R. 47, nr 7, 7; 24-28
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the topology of „Shore to Ship” systems - power electronic connection of ships with land
Autorzy:
Tarnapowicz, Dariusz
German-Galkin, Sergiei
Powiązania:
https://bibliotekanauki.pl/articles/27315926.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
system Shore to Ship
przetwornica częstotliwości
zasilacz wysokiego napięcia
Shore to Ship system
frequency inverter
high voltage power supply
Opis:
The possibility of building efficient and universal systems for the use of electricity land network by ships berthed in the port appeared along with the development of power electronic technologies. The need to connect ships to the land network is primarily related to ecological reasons. The choice of the appropriate topology by the investor (usually port authorities) is mainly connected with ensuring high quality of electricity provided to the ship and local conditions. The article reviews topologies of power electronic system (possible to use) for connection of ships with the land network - their disadvantages and advantages.
Źródło:
New Trends in Production Engineering; 2018, 1, 1; 325-333
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The study of electronic voltage transducers operation in conditions of dips and interruptions of measured voltage
Autorzy:
Kaczmarek, M.
Szczesny, A.
Nowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/201639.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
voltage transducer
voltage interruptions and dips
power quality
reliability of power supply
Opis:
The aim of the paper is to present a response on dips and on interruptions of the measured voltage by means of electronic voltage transducers and inductive voltage transformers. Results of laboratory studies show high overvoltages generated in both a primary and secondary side of inductive VTs during the above mentioned conditions. Overvoltages in secondary circuits may damage measuring or protection apparatus connected to the secondary side of the VT. Using electronic voltage transducers enables users to avoid these problems.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 3; 645-649
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Guaranteed Power Supply System on the Base of Alternative and Renewable Energy Sources
Autorzy:
Abramovich, B. N.
Sychev, Y. A.
Fedorov, A. V.
Powiązania:
https://bibliotekanauki.pl/articles/262687.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
alternative
renewable
power supply
voltage sag
power supply interruption
distributed generation
guaranteed
uninterrupted
Opis:
The necessity of developing and implementation of the guaranteed power supply system using distributed generation on the base of alternative and renewable energy sources is proved in conditions of responsible technological processes. The theoretical and experimental researches were made in raw mineral enterprises, which have a great amount of responsible technological consumers. The permitted duration of power supply interruption for responsible consumers of continuous technological processes of raw mineral industry is determined. The effectiveness of distributed generation using for guaranteed power supply mode is shown. The reasonability of solar, wind and followed oil gas energy applying in role of power sources for distributed generation is also proved in the paper. The basic variants of guaranteed power supply system structure are described and offered in the paper for all kind of industry and technique, especially for responsible digital control systems and telecommunications.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2015, 18, 1; 1-6
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies