Tytuł:
Tests of HTS 2G superconducting tapes using the LabVIEW environment
Autorzy:
Kwoka, R.
Kozak, J.
Majka, M.
Powiązania:
https://bibliotekanauki.pl/articles/118249.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
superconducting winding
HTS tape
LabVIEW
superconducting fault current limiter
uzwojenie nadprzewodzące
Taśma HTS
nadprzewodnikowy ogranicznik prądu zwarciowego
Opis:
HTS 2G superconducting tapes without stabilizer are used for the construction of superconducting fault current limiters. The characteristics R =f(T) of the su-perconducting tape is essential for design of superconducting current limiters and analysis of their numerical models. The article presents the experimentally determined characteristics R=f(T) of the second ge-neration superconducting tapes SF4050 and SF12050 using the LabVIEW integrated environment. The article describes the method of sample preparation and methodology of testing of HTS 2G superconducting tapes. The LabVIEW integrated environment was used for the testing, thanks to which it was possible to download, process and save measurement data.
Źródło:
Applied Computer Science; 2018, 14, 1; 64-72
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of heating of inductive superconducting fault current limiter windings on current limiting performance
Wpływ nagrzewania się uzwojeń nadprzewodnikowego ogranicznika prądu na wydajność ograniczania prądu
Autorzy:
Kafarski, M.
Adamczyk, Ł.
Kozak, S.
Kozak, J.
Majka, M.
Powiązania:
https://bibliotekanauki.pl/articles/408798.pdf
Data publikacji:
2012
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
nadprzewodnikowy ogranicznik prądu
taśma HTS
nagrzewanie taśmy HTS
inductive superconducting fault current limiter
HTS tape
heating of HTS tape
Opis:
One of the types of superconducting fault current limiters are inductive. Windings in these limiters are made of second generation superconducting tapes (HTS 2G). Large resistance in resistive state and large currents flowing by the limiter windings during the fault cause the dissipate significant amounts of power and strong heating of the windings, which causes increase in impedance of the limiter. We discuss the influence of the windings heating on the value of limiting short circuit current.
Jednym z typów nadprzewodnikowych ograniczników prądu są ograniczniki typu indukcyjnego. Ich uzwojenia wykonane są z taśmy nadprzewodnikowej drugiej generacji (2G). Duża rezystancja w stanie rezystywnym i duże wartości prądów zwarciowych powodują wydzielanie dużych ilości energii i silne nagrzewanie uzwojeń, które powoduje wzrost impedancji ogranicznika. W artykule omówiono wpływ agrzewania sie uzwojeń na wydajność ograniczania prądów zwarciowych.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2012, 1; 24-27
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bezrdzeniowe nadprzewodnikowe ograniczniki prądu zwarciowego typu indukcyjnego
Corless Inductive Superconducting Fault Current Limiters
Autorzy:
Majka, M.
Powiązania:
https://bibliotekanauki.pl/articles/159712.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
bezrdzeniowy nadprzewodnikowy ogranicznik prądu zwarciowego
taśmy nadprzewodnikowe
test zwarciowy
ciekły azot
coreless superconducting fault current limiter
superconducting tapes
short-circuit test
liquid nitrogen
Opis:
Siły elektrodynamiczne występujące w trakcie przepływu prądu zwarciowego mogą uszkodzić urządzenia systemu elektroenergetycznego w ciągu kilkudziesięciu milisekund. Każde uszkodzenie sieci elektrycznej tego typu pociąga za sobą kosztowne i czasochłonne naprawy, dlatego ważne jest, aby działanie sieci było zabezpieczone niezawodnym systemem ochrony. Nadprzewodnikowy ogranicznik prądu zwarciowego (SFCL – ang. Superconducting Fault Current Limiter) to urządzenie elektryczne o znikomej impedancji w normalnych warunkach pracy, które przechodzi w stan wysokiej impedancji podczas zwarcia, ograniczając prąd zwarciowy. Ograniczniki nadprzewodnikowe działają bardzo szybko, ograniczając pierwszą, najniebezpieczniejszą szczytową wartość prądu zwarciowego, chroniąc w ten sposób urządzenia sieci elektrycznej przed dynamicznymi skutkami przepływu prądu zwarciowego. W pracy omówiono główne zagadnienia dotyczące nowych konstrukcji bezrdzeniowych ograniczników prądu zwarciowego typu indukcyjnego o parametrach znamionowych 6,9 kV / 600 A i 15 kV / 140 A. Kompaktowa konstrukcja bezrdzeniowego ogranicznika prądu zwarciowego składa się z trzech sprzężonych magnetycznie uzwojeń chłodzonych ciekłym azotem. Przedstawione bezrdzeniowe konstrukcje ograniczników mają małą masę, a napięcie na ograniczniku podczas normalnej pracy jest znikome. W pracy przedstawiono projekty i modele numeryczne ograniczników oraz wyniki testów zwarciowych. Praca zawiera również wyniki badań eksperymentalnych prowadzonych nad taśmami nadprzewodnikowymi drugiej generacji z których obecnie budowane są ograniczniki. Wyniki tych badań są niezbędne przy konstruowaniu modeli numerycznych nadprzewodnikowych ograniczników prądu.
The electrodynamic forces occurring during the course of a fault current may damage the devices of the electric power system within tens of milliseconds. Every such failure of an electric power network entails expensive and time-consuming repairs. Therefore, it is vital that the network’s operation be secured with a reliable protection system. A superconducting fault current limiter (SFCL) is an electrical device with a negligible impedance in normal operating conditions that switches to a high impedance state during fault, limiting short circuit current. SFCLs react very rapidly by limiting the first, the most dangerous, surge current during a current fault condition, thus protecting the devices of the electric power network from the dynamic effects of current faults. This paper discusses the main issues concerning the new coreless constructions of inductive type fault current limiters with rated parameters 6.9 kV / 600 A and 15 kV / 140 A. Compact design of the coreless superconducting fault current limiter consists of three magnetically coupled windings cooled in liquid nitrogen. The presented coreless constructions of current limiters have low weight and the voltage on the limiter during the normal operation is negligible. The paper presents the designs and numerical models of the limiters and presents the results of tests performed at a high-power test facility. The paper also contains the results of experimental research on second generation superconducting tapes, they are necessary to make numerical models of superconducting current limiters.
Źródło:
Prace Instytutu Elektrotechniki; 2018, 279; 1-182
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury na pracę nadprzewodnikowego ogranicznika prądu dla sieci średnich napięć
Influence of Temperature on the Operation of the Superconducting Fault Current Limiter for Medium Voltage Networks
Autorzy:
Kozak, Sławomir
Majka, Michał
Kozak, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/159774.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
nadprzewodnikowy ogranicznik prądu
SFCL
wysokotemperaturowa taśma nadprzewodnikowa II generacji
HTS
superconducting fault current limiter
2nd generation high temperature superconductor tape
Opis:
Nadprzewodnikowy ogranicznik prądu dla sieci średniego napięcia chłodzony z wykorzystaniem kriochłodziarki, sfinansowany przez NFOŚiGW oraz NCBiR, w ramach projektu: GEKON2/O2/267193/13/2015, testowany był Instytucie Elektrotechniki. Do budowy tego ogranicznika wykorzystana została wysokotemperaturowa taśma nadprzewodnikowa II generacji – SF12100. W tym ograniczniku istnieje możliwość zmiany roboczej temperatury pracy. Przeanalizowana została praca ogranicznika w trzech temperaturach: 72 K, 80 K i 86 K, w których dokonane zostały eksperymentalne próby zwarciowe oraz niższych temperaturach: 38 K, 51 K, 66 K i w temperaturze ciekłego azotu: 77,4 K. Można zwiększyć wielokrotnie prąd roboczy poprzez obniżenie temperatury pracy ogranicznika. Dla temperatur początkowych powyżej 51 K maksymalna temperatura taśmy nadprzewodnikowej w chwili wyłączenia prądu zwarciowego przez zewnętrzny wyłącznik (t = 0,08 s) nie przekracza 290 K. Dla temperatur powyżej 51 K w przypadku badanego ogranicznika można rozważać zwiększenie czasu ograniczania prądu. Wydłużenie czasu pracy ogranicznika zwiększy maksymalną temperaturę taśmy nadprzewodnikowej i wydłuży czas schładzania ogranicznika po ograniczeniu zwarcia.
The superconducting fault current limiter (SFCL) for medium voltage networks cooled using a cryocooler was financed by NFOŚiGW and NCBiR, under the project: GEKON2 / O2 / 267193/13/2015, and was tested in the Electrotechnical Institute. The 2nd generation high temperature superconductor (HTS) tape – SF12100 was used to build this SFCL. In this limiter it is possible to change the operating temperature. The limiter operation was analyzed at three temperatures: 72 K, 80 K and 86 K, in which the experimental short-circuit tests were made and at lower temperatures: 38 K, 51 K, 66 K, and at liquid nitrogen temperature: 77,4 K. The operating current can be increased many times by lowering the limiter's operating temperature. For initial temperatures above 51 K, the maximum temperature of the superconducting tapes when the short-circuit current is switched off by an external switch (t = 0,08 s) does not exceed 290 K. For temperatures above 51 K, the current limitation time can be increased. Extending the limiter's operating time will increase the maximum HTS tape temperature and extend the limiter's cooling time after limiting the short-circuit.
Źródło:
Prace Instytutu Elektrotechniki; 2020, 281; 39-47
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie charakterystyk R = f(T) taśm nadprzewodnikowych pierwszej i drugiej generacj
Determination of R = f(T) characteristics of the first and second generation superconducting tapes
Autorzy:
Kwoka, R.
Kozak, J.
Majka, M.
Powiązania:
https://bibliotekanauki.pl/articles/408390.pdf
Data publikacji:
2018
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
nadprzewodnictwo
taśma nadprzewodnikowa HTS pierwszej i drugiej generacji
nadprzewodnikowy ogranicznik prądu zwarciowego
superconductivity
1st and 2nd generation HTS tape
superconducting fault current limiter
Opis:
W artykule przedstawiono eksperymentalnie wyznaczone charakterystyki R = f(T) taśm nadprzewodnikowych pierwszej (1G) i drugiej generacji (2G). W pracy opisano sposób przygotowania próbek taśm nadprzewodnikowych 1G i 2G do badań, opisano metodę pomiarową oraz przedstawiono wyniki badań eksperymentalnych.
The experimental characteristics R = f(T) of the first (1G) and the second (2G) generation HTS tapes are presented in this paper. The paper describes samples preparation of 1G and 2G superconducting tapes, describes the measurement method and the results of experimental studies.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2018, 8, 1; 71-74
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies